WELDING INSPECTION
FERRISTCOPE FMP30
Ferritscope measures the ferrite content in austenitic and duplex steel according to the magnetic
induction method. All magnetic components of the otherwise non-magnetic structure are recognized, that
is, in addition to delta ferrite and other ferritic components transformation martensite is also recognized.
Features :
• Measurement of the ferrite content in a range of 0.1 to 110 FN or 0.1 to 80% Fe in austenitic and duplex steel.
• Measurement accuracy according to ANSI/AWS A4.2M/A4.2:1997 standard.
• Calibration with standards traceable to TWI secondary standards or with customer-specifi c standards.
• Measurement units selectable between WRC-FN and % Fe.
• Memory for up to 20,000 readings.
• Up to 100 applications for measuring application specific calibrations.
• Display of statistical common characteristic values
• Graphical measurement display as a histogram with a gaussian plot.
• Data transfer to a PC into an excel spreadsheet with the optional PC program PC-Datex.
Technical Data
Ferrite content in weld seams and claddings made austenitic or duplex
Measureable coating
Portion of deformation martensitic in austenitic materials.
Measuring modes Magnetic induction measurement method.
Operation/storage/humidity 10°C - 40°C / 10°C – 60°C / 10% - 90%.
Power supply 4 x 1,5volt batteries (AA) or AC adaptor 9V 150 mA, 100V - 230V.
Connectors Probe, AC adapter, mini USB port.
2
COATING THICKNESS MEASUREMENT
QNIX 4500
QNix® 4500: The global bestseller for standard applications.
Technical Data
Features : Fe-Probe Measurement on iron and steel substrate
1. For measurement coating thickness with Nfe Probe Measurements on non magnetic metal substrates, such
based material ferrous and non ferrous. as aluminium, zinc, cooper, etc
2. Automatic indentification of gauge, Resolution 0,1 µm (0 to 99,9µm), 1 µm (100 bis 999µm),0,01µm (>1,00mm)
including transfer of data and settings. Minimum Area Fe probe 20 x 20 mm2
3. Easy configuration of all major fuction of Nfe Probe 20 x 20 mm2
Qnix® 8500 on the PC. Minimum Curvate Convex 5 mm
4. Simultaneous operation and administration Concave 30 mm
of multile Qnix® 8500 gauges. Minimum Substrate Fe Probe 0,2 mm
5. All languages installable via editor Thickness Nfe Probe 0,05 mm
(including gauge software).
Temperature Range Storage (- 100C to 600C), operating (00C to 500C)
6. Downloadable software updates via internet
7. Online measurements.
8. Averaging and continuous measurement
Order No Type Description
mode.
Qnix8500 Premium set w/o probe coat-
QN0000003 360001 ing thickness gauge
QN0000004 378045 Digital dual-probe FE/NFE 2000 micron
3
COATING THICKNESS MEASUREMENT
MINI TEST 7400 High-precision coating thickness gauge
• Non-destructive measurements on all metal substrates.
• Convenient graphics display with numerous display options.
• Intuitive menu control, enhanced data management with
configuration assistant.
• PC software for simplified configuration evaluation and
set-up of data reports.
• Wear-resistant sensors for numerous measuring tasks up to
35 mm thickness.
• SIDSP® technology for accurate and reproducible readings.
Probe selection:
Ferrous: F0.5, F1.5, F1.5-90, F2, F5, F15, F35
Non-Ferrous: N0.2, N0.7, N0.7-90, N2.5, N7
Dual probe (Fe&NFe): FN1.5, FN1.5-90, FN5
Max range:
Ferrous: 500um, 1.5mm, 2mm, 5mm, 15mm, 35mm
Non-Ferrous: 200um, 700um, 2.5mm, 7mm
Dual probe (Fe&NFe): F1.5mm/NF0.7mm, F5mm/NF2.5mm
Measurement of:
• Non-magnetic coatings (e. g. paint, zinc) on steel.
• Insulating coatings (e. g. paint, anodising coatings) on non-ferrous metals.
• Non-ferrous metal coatings on insulating substrates.
• Wear-resistant probes for multi-purpose use.
• High accuracy and reproducibility.
• Storage and documentation of readings.
4
COATING THICKNESS MEASUREMENT
WET FILM THICKNESS GAUGE
Coating thickness SurfaTest
Measurement
Durable Stainless Steel
Wet Film Gauge
• small “foot print”
• mils and microns
• 16 measuring points
Scale Graduations
microns mils
25 50 75 100 1 2 3 4
125 150 175 200 5 6 7 8
250 300 350 400 10 12 14 16
500 600 700 800 20 24 28 32
5
MATERIAL ANALYSIS AND COATING THICKNESS X-RAY
FISCHERSCOPE® X-RAY XAN® 220 and 250
The XAN 220 is optimized for fast, non-destructive analysis of jewelry, precious metals, dental alloys,
yellow and white gold, platinum, silver, rhodium and all jewelry alloys and coatings.
Typical fields of application are the analysis of:
● Jewelry,
● Precious metals
● Dental alloys
● Yellow and white gold
● Platinum and silver;
● Rhodium
● Alloys and coatings
● Multi layer coatings
The XAN 250 is an universal high performance analysis instrument can accurately determine elements in the range of
Aluminum to Uranium. The XAN 250 is especially well suited for measuring and analyzing thin coatings.
Typical fields of application:
● Measurement of functional coatings, starting from a few nanometers, in the electronics and semiconductor industries
● Trace analysis for consumer protection, e.g. lead content in toys
● Analysis of alloys with highest requirements of accuracy in the jewelry, watch, and metal.
● Research in universities and in the industries
Order No Description
EV0000067 Colortest
Technical Data
Measuring Geometry 45°/0° according to DIN 5033, optional d/8° with MA35-UK adapter
Illuminants D65, D55, D50, A, C, F11
Standart Observer 2° and 10°
Colour Scales XYZ, Yxy, ∆E CIE L*a*b*, L* u* v*, L* C* h, Hunter Lab, pass/fail
Spectral Range 400 nm to 700 nm, scanning in 3.5 nm steps
Light Source white and blue LED`s, extremely long life span
Power Supply Rechargeable battery NiMH 6 Volt/1.100 mAh - 15 hours use
PC-Interface USB 2.0, Bluetooth (optional), RS232 (optional)
Norms and Standards ASTM D 2244
Accessories for the measurement of inhomogeneous samples, transparant, translucent and opaque liquids, powders in cuvettes or tablet
form and more
Climatic Conditions ambient temperature: 15°C to 45°C, relative humidity: max. 85% non-condensing
6
COATING ANALYSIS MEASUREMENT
PICOGLOSS
The Picogloss is intended for the measurement of gloss
on level surfaces and uses the principle of a reflectometer.
• Picogloss 562 MC Gloss meter with two measuring angles 20° and 60°.
• Picogloss 503 Glass meter with three measuring measuring angles 20°/60°/85°.
• Picogloss 560 MC Gloss meter with single measuring angles 60°.
Features :
• Micro processor electronics.
• Gloss measurement in the range 0.0–150.0 gloss units.
• Mirror gloss measurements from 150–1999 gloss units with autoranging facility.
Technical Data
Measuring Value Display 3 1/2 digit LCD
Measuring Geometry choice of either 20° and/or 60°
– Light type A (DIN 67 530) or
Figure 1: measuring principle Light Type, Choice Of Either
– Light type C (ISO 2813)
L = Light source B = Diaphragm
Power Supply rechargeable battery
O = Specimen surface P = Photocell
Dimensions (W x D x H) 136 x 42 x 78 mm
Net weight: 0.5 kg
Technical Data
High voltage
P7 P30 P35
probe
Operating range 0.5 ... 7kW 3 ... 30kW 6 ... 35kW
Voltage DC
Test voltage
LC-Display, 3-digit
indication
Accuracy of
± (0.1kW + 3% of reading)
voltage setting
Dimensions.
274mm x 63mm (l x dia)/550g
weight of high
10.8" x 2.48"/1.2 lbs/19.4 oz.
voltage probe
Dimensions/
225mm x 150mm x 85mm (L x W x H)/1400g
weight of control
8.87" x 5.9" x 3.35" (L x W x H)/3 lbs/49 oz
unit
7
PORTABLE HARDNESS TESTER
EQUOSTAT 3
Equostat 3 Probe
Measuring Range 19-70 HRC; 19-70 HMMRC; 67-638 HB; 35-950 HV; 60-86 HRA; 29-107 HRB; 225-2250 MPa; 69-94 HR15N; 88-96 HR15T
Resolution 0.1 μm; 0.1 HRA; 0.1 HRB; 0.1 HRC; 0.1 HRE; 0.1 HRH; 0.1 HR15N; 0.1 HR15T; 1 HB; 1 HV; 0.1 HS; 1 MPa
Measuring Accuracy ~ ± 1.5 HRC Over Entire Range
Max. Imum Test Hardness 70 HRC
Test Direction Any Direction (No Correction Required)
Test Loads 10 N / 50 N (probe 50 N)
Diamond Indenter angle 100.0° ± 0.5°
8
PORTABLE HARDNESS TESTER
PAROTESTER 2
Features :
Parotester 2 is an equipment to measure HARDNESS VALUE “L”. This term, introduced to hardness measuring technology in 1978,
hardness value of reel hardness, hardness is the quotient of the impact and rebound velocity of the impact body multiplied by 1000.
profile in a paper Hardner wound locations produce a higher rebound velocity than those of lesser hardness.
OBJECTIVE. This result is a digital hardness value
Technical Data
Testing method | Available probe | Contact force Leeb rebound | Type U | 120 N.
Spherical test callote Stainless steel 50 mm (2”) tip diameter (60 HRC).
Max material penetration | Resolution | Accuracy 4.0mm | 1LU | 6LU (±1% at 600 LU).
Data storage | Operating temp 5000 value | 0o-50oC.
Communication | PC software RS 232C | Parolink 3 software (not included).
Features :
• Measurement only takes a few second. • 4000 point of data memory.
• Leaves only tiny indentation on test speciment. • Portability makes it ideal for use in the
• Hardness value can be read directly (HV, HRC, Hs, Hb). field.
• Convertion to breaking strength (N/mm2). • Easy data management using PC with data
• Measuring stands (wooden, iron, resin, etc) do not influence transfer software (Option).
measurement. • Ultrasonic technology.
Technical Data
Measuring Indenter Diamond identer for Micro-Vickers (facing surface angel of 136°)
Approx. 2 kgf SH-21-E2
Approx. 1 kgf SH-21-E1
Test load and control
Approx. 4 kgf
SH-21-E4
(special probe type manual only)
Measuring range 10-70HRC / 50-999HV / 0-99,9SHORE / 85-550HB
HRC : ±1.0HRC, HV : ±(3%rdg)HV,
Reproducibility
HS : ±1.0HS, HB ; ±(3%rdg)HB.
With steel as the principle material, other metallic materials may also be measured
Applicable test material
by calibrating against a standard hardness test block
Display value Digital display (LCD, 4 digit) with backlight
Data memory 2000 pieces
Standard JIS B 7731, ASTM E 140, DIN 50150
1 display unit, 1 probe (including standard attachment / UA5410), 1 hardness
standard test block (around 55HRC), 1 probe cable 1.5m, 1AC adapter 100-240V
Standard component
(A05C1-09MI), 1 recharger (MK-8220), 1 lithium ion battery (MK-8410), 1 carrying
case (MK-9701)
9
WALL THICKNESS GAUGE
ULTRASONIC TI-45N
Features:
* Resolution of 0,01 mm
* Extremly compact and leight weight
* Switch selectable units mm or inches
* Built in calibration test plate
* Quick display update with last reading retained on the
display
* Display symbols alert user to poor coupling and low
battery conditions
Technical Data
Measuring range
Pulse Echo Mode: 0.63 to 500 mm / 0.025 to 19.999 inches in steel. depending on material and surface
Echo Echo Mode: 2.54 to 25.4 mm / 0.1 to 1 inch
Resolution : 0.01 mm / 0.001 inch
Velocity range : 1250 to 10.000 m/sec/0.0492 to 0.3937 inches/µs
Operating temperature: - 30° to 50°C/ -20° to 120°F
Data Output: RS232 output sends data to a serial printer, a computer or other external storage device.
Internal data logger: Automatic numeric Data Logging system 1 to 1000 readings
10
WALL THICKNESS GAUGE
MINITEST FH-7200
Features:
High-precision Thickness Measurement
• On non-ferrous Materials
• Measures up to 4mm or 10 mm thick
• Ideal for Bottles, Aluminum Cans, Glass and Plastic Components with Complex Shapes
• Menu-controlled User Interface
• Context-sensitive on-line Help
• SPC Capabilities
Specification
0 - 1,5 with 1,5 reference ball
Measuring Range FH4 (mm) 0 - 2,5 with 2,5 reference ball
0 - 4,0 with 4,0 reference ball
0 - 2.5 with 2.5 reference ball
Measuring Range FH10 (mm) 0 - 4.0 with 4.0 reference ball
0 - 10.0 with 6.0 reference ball
Low Range Resolution (μm) 0,01 µm (FH4) / 0.2 µm (FH10)
Measuring principle Magnetostatic
Data Memory 240.000 values
Statistic charting Numeric, trend, and histogram (with Minitest 7400 FH only)
Interfaces RS232 TTL + IrDA 1.0
Operating temperature -10°C +60°C (Storage temperature" -20°C to +80°C)
Power supply 4 x AA (LR06) batteries, or optional power unit (90 -240V~/48-62 Hz)
CUTTING MACHINE
Precision Abrasive Cutting Machine CK200
11
CUTTING MACHINE
Precision DIAMOND SAW CL50
Features :
● Automatic return at the end of cut
● Cutting thickness either in inch or metric
● Opening cover during cutting shuts the machine down
● Low consumption 120W
PRECISION-CL SERIES
Model No CL50
Loading Pressure 0~700g
Cut-Off Wheel Ø3"~7"
Min. Display 0.01mm
Weight 43kg
Horsepower 120W
Machine Size (WxDxH) 570 x 620 x 440mm
Rotational Speed 150~2000rpm
Power Supply AC110V/220V-1Ø
Horizontal Movement 0~40mm
Features :
∙ Heating time is quick, power consumption 1,200W.
∙ Heating and cooling time can be freely adjusted,
suitable any material changing.
∙ Table type design is practical, not occupying space.
∙ Mounting, heating and cooling are all automatically
controlled, convenient for mass production test.
12
MOUNTING PRESS MACHINE
VACUUM IMPREGNATION
Feature:
● The vacuum pulls air from the mold,
displacing it with epoxy, providing complete
encampsulation.
● High vacuum density
● Easy operation
GRINDING/POLISHING
AIR AUTO GRINDING/POLISHING MACHINE
Features :
∙ Accurate turning balance that is not shifting even by force.
∙ Double water proof covers design for safe and simple grinding and
polishing. The work piece does not fall off easily.
∙ Replaceable grinding and polishing plates that can be replaced quickly.
∙ Noise level : below 55 decibels within 1.5m from the machine.
∙ Over current protection : the current output automatically cuts down in
case of over current to protect the motor.
P20F-1-HA
P25F-1-HA
P20FR-HA, P25FR-HA
13
GRINDING/POLISHING
AIR AUTO GRINDING/POLISHING MACHINE
P20FS-1-A3-HA
P20FS-1-A5-HA
P25FS-1-A3-HA
P25FS-1-A5-HA
HIGH QUALITY AND ULTRA MUTE
Low rotation speed, high torque,
digitalized rotation speed display
• Automatic
• Economical
• Fast
P20FRS-1-A3-H, P20FRS-1-A5-H
P25FRS-1-A3-H, P25FRS-1-A5-H
METALLURGICAL MICROSCOPE
RMZ STEREO ZOOM MICROSCOPE
Specifications :
∙ Multicoated high contrast optical system.
∙ All lenses are fully anti-fungus coated.
∙ Zoom objective magnification 0.7x ~ 4.5x (model : RMZ745 series) ratio : 1 : 6.4.
∙ Zoom objective magnification 1.0x ~ 6.5x (model : RMZ1065 series) ratio : 1 : 6.5.
∙ Parfocal system to minimize the focusing adjustment from low magnification to
high magnification.
∙ Working distance : 118mm.
∙ With high eyepoint and wide field eyepiece SWH10X (F.N.22).
∙ Incline 45o and main body can be rotated 360o.
∙ Both eye-tube with diopter adjustment ±6mm.
∙ Interpupillary distance adjustment range from 55mm to 75mm.
∙ Ergonomic design for handling and transportation.
∙ Dust cover : glossy thick dust cover.
∙ Wide base integrated stand with white/black stage plate (standard ST503).
∙ Wide range accessories for selection.
∙ Upgrade able magnification range : 2X - 225X (RMZ745 series) or 3X - 325X
(RMZ1065 series) with optional accessories.
14
METALLURGICAL MICROSCOPE
RMS6000 INVERTED METALLURGICAL MICROSCOPE
Specifications :
∙ Multi coated high contrast optical system.
∙ All lenses are fully anti fungus coated.
∙ inverted main body with binocular veiwing of 45o including analyzer.
∙ Mechanical stage : moving range 75 x 50mm and stage size 180 x 155mm.
∙ Focusing : Coaxial coarse and fine adjustament. Vertical objective movement.
∙ Plan wide filed eyepiece 10 X(F.N.20mm).
∙ Quntuple nosepiece : inner locating on ball bearing.
∙ Plan achromatic objective lens : 5X / 0.10, 10X / 0.25, 20X / 0.35, 50X / 0.65
and 0.80.
∙ Large stage accessories : stage plate 1, stage plate 2, stage plate 3, stage
plate holder and speciment clamps.
∙ Vertical illumination : halogen lamp 6V30W adjustable brightness with polarizer.
∙ 0.5X camera adapter with reticle scale.
It is widely used in unstitute and laboratory to observe ∙ Stage plate 4.
and identify the structure of various metal an alloy as well ∙ Digital camera/ CCD video camera accessories.
as for for routine quality inspection. ∙ Photo micrography couplings S5X or S6.3X.
METALLURGICAL MICROSCOPE
MM10A METALLURGICAL MICROSCOPE
Specifications :
∙ Multicoated high contrast optical system. ∙ Size : 274mm x 274mm, can be
∙ All lenses are fully anti-fungus coated. moved quickly, moving range :
∙ Compensation free trinocular head (inclined 30 )
o 203mm x 203mm.
including analyzer lens. ∙ 0.4X ccd camera adapter.
∙ Quintuple objective lens nosepiece. ∙ Vertical illumination .
∙ Plan achromatic objective lens magnification / 6V/20W halogen lamp, adjustable
numerical aperture / working distance. brightness with polarizer.
∙ PL5X/0.12/18.3mm. ∙ Optional : Size : 250mm x 230mm,
∙ PL10X-0.25/8.9mm. can be moved quickly, moving range :
∙ PL20X/0.70 (spring)/2.02mm. 153mm x 153mm.
∙ PL80X/0.80 (spring)/0.96mm. ∙ Optional : Digital camera / CCD
∙ High eyepoint eyepiece WF 10x (F.N.18). video camera accessories.
∙ Optional : PL100x dry objective lens.
15
LAYANAN PURNA JUAL MEASURING
SERVICE CENTER
Telp. (021) 582-9022
servicekls@kawanlama.com
√ Service resmi dengan suku cadang asli
√ Instalasi dan perbaikan oleh teknisi yang terlatih dan berpengalaman
√
Konsultasi gratis melalui hotline dan e-mail
Dapatkan unit dan suku cadang hanya melalui distributor resmi (PT Kawan Lama Sejahtera) untuk menjamin kualitas dan daya
tahan produk. Hindari kerusakan dini dan kesalahan pada saat pemakaian dengan hanya menggunakan suku cadang asli.
KLS/P&A.088/5K/11.10/can.uni/09.13
kls/p&a.159/5k/measuring.20/hen.gra/4.14
16