Features
Freely Programmable
• IEC 61131-3 Programming Language
I/O Extension
• Physical inputs and outputs with stackable L-IOB
I/O Modules
Manual Control Level
• 128x64 display with backlight
• Access to information about device status and data
points
• One hand operation using the turn-and-push dial
Automation Functions LINX-120 and LINX-121 manage scheduling locally
• Alarming, Scheduling, and Trending (AST ™) including exception day schedules.
• Event-driven E-mail notification
Alarm monitoring, trend and event logging is
Visualization included.
• Managing of customized graphical pages
• Representation via LWEB-800 Visualization Customized graphical pages with dynamic con-
tent can be stored on the L-INX Automation Server
OPC and be accessed with the LWEB-800 Visualization
• Built-in OPC XML-DA Server environment using Web technologies. LWEB-800 is
• Access to data points via Web services a freely available .NET application at no cost.
• Access to network statistics
With LWEB-800 users can perform operation and
CEA-709, ISO/IEC 14908 management of embedded data points regardless
• Complient with CEA-709, CEA-852, ISO/IEC 14908 of the communication technology. Time schedul-
standard (LONMARK® systems) ing, alarm overview, trend, and data points can be
• Supports TP/FT-10 or IP-852 (Ethernet/IP) channels accessed via LWEB-800 or alternatively through
• Support of dynamically created network variables individual L-INX integrated web servers.
or static network variables Time- or event-dependent operating conditions or
• Support of user defined NVs (UNVTs) and configu- trends can be sent via e-mail.
ration properties (SCPTs, UCPTs) Optionally, L-IOB I/O modules can be added to
• Remote Network Interface (RNI) with 2 MNI devices LINX-120 series servers to manage and control
(LINX-120 only) building equipment.
• Integrated IP-852 to TP/FT-10 Router (LINX-121 only) The Automation Servers can be connected to a
M-Bus CEA-709 TP/FT-10 or IP-852 (Ethernet/IP) chan-
• M-Bus Master according to EN 13757-3 nel.
• Connection of M-Bus devices via optional M-Bus The varied IP communication access choices allow
Converter (e.g. LMBUS-20) for use in distributed property management buil-
Modbus ding an IP-based automation solution.
• Modbus TCP and Modbus RTU (Master or Slave)
Configuration
• Integrated Web server for the device configuration
and for monitoring of data points LWEB-830 Dream Report
LWEB-800 Visualization
status
L-INX
LINK
L-INX
www.loytec.com LINK www.loytec.com www.loytec.com
ACT ACT
PLC OPC
Automation Server Wired/Wireless PLC OPC
Automation Server L-IOB
1 2 3 4 1 2 3 4 I/O Module
>= S1 SR Q1
<=
x
-1
LOYTEC LINX-120
Ethernet
1 2
USB MICROSD FT MS/TP MODBUS EXT
ACT
100
89
PLC OPC
Automation Server
Ethernet 1 Ethernet 2
1
FT
2
MS/TP
3
MODBUS
4
EXT
device instantly without interrupting the currently
running program.
159
Visualization
164
60
Manual PLC OPC
Automation Server
3rd Floor
50 Scene 1 1
FT
2
MS/TP
3
MODBUS
4
EXT
40 2nd Floor Ethernet 1 Ethernet 2
30 Scene 2
No Rain 53542 lux 37.2°/256.4° 20 1st Floor
10
Off
30°C 12 1/s 35°C 5 1/s 0 Basement
26/07/2007 15:23:20 5 bar
L-INX
www.loytec.com LINK www.loytec.com
PLC OPC
Automation Server L-IOB
I/O Module
LWEB-830 reporting software. Reports can be Ethernet 1 Ethernet 2
1
FT
2
MS/TP
3
MODBUS
4
EXT
UI1 UI2 UI3 UI4 UI5
UNIVERSAL IN
UI6 UI7 UI8
DIGITAL IN
DI1 DI2 AO1
0-10V OUT
AO2
Specifications
Dimensions (mm) 159 x 89 x 75 (L x W x H) Remote Network Interface 2 MNI devices (LINX-120 only)
Weight 350 g CEA-709 Router 1 (LINX-121 only)
Installation DIN rail mounting (EN 50 022) Number of graphic Depending on memory space
Operating temperature 0 °C to 50 °C (ambient) projects
Storage temperature -10 C to 85 °C Web server Configuration / DP Monitoring
Relative humidity 10-90 % RH @ 50 °C (non con- Number of LWEB-800 15 (simultaneous)
densing) clients
Degree of protection IP 40 (enclosure) Programming L-logiCAD software
IEC 60529 IP 20 (terminals) (IEC 61131-3)
Power supply 12-35 VDC / 12-24 VAC ±10 % Cycle time Down to 10 ms
Power consumption Typ. 3 W IEC 61131-3 variables 1 000
Inrush current Up to 950 mA @ 24 VAC Network variables (NV) 1 000
Processor ARM9 CPU, 400 MHz Alias NVs 1 000
Memory 64 MB RAM, 256 MB Flash External NVs (Polling) 1 000
Memory extension microSD card, max. 2 GB Address table entries 512 (legacy mode: 15)
Interfaces 2 x Ethernet (100Base-T) LonMark Calendar 1 (25 calendar templates)
- OPC XML-DA LonMark Scheduler 100
- IP-852 (LonMark® system) LonMark Alarm Server 1
- Modbus TCP (Master/Slave) Trend-Logs 100 (max. 256 data points,
- HTTP, FTP max. 6 MB)
1 x TP/FT-10 (LonMark® system)
E-mail templates 100
1 x Modbus RTU (Master/Slave)
1 x M-Bus (Master EN 13757-3) Mathematical objects 100
2 x USB-A, 1x USB-B Alarm logs 10
Manual control level 128x64 display, white backlight. OPC data points 2 000 (XML-DA)
Access to device information and M-Bus data points 1 000
data points (additionally for the M-Bus address range 0...250 (primary address)
optional L-IOB I/O Modules) Modbus data points 2 000
Status/Activity LEDs Networks, IEC 61131-3, OPC DP connections 1 000
Time base Real-Time-Clock (RTC) L-IOB I/O Modules Max. 8 modules
Time synchronization Network Time Protocol (NTP)
LC3020, L-Chip, L-Core, L-DALI, L-GATE, L-INX, L-IOB, L-IP, L-MBUS, LPA, L-Proxy, L-Switch, L-Term, L-VIS, L-WEB, and ORION stack are trademarks of
LOYTEC electronics GmbH. Other trademarks and trade names used in this document refer either to the entities claiming the markets and names,
or to their products. LOYTEC disclaims proprietary interest in the markets and names of others.
LOYTEC reserves the right to make changes to these specifications without further notice for performance, reliability, production technique, and
other considerations.