Sei sulla pagina 1di 2

BULLETIN 20-10-1

June 2001

CONVERSION
N O Z Z L E K I T

Sporlan’s Conversion Nozzle The


Kit saves you time and expense conversion
when changing from refriger- nozzles come in a handy kit,
ants 12 or 502 in supermarket complete with hard plastic
systems to R-22 or the new carrying case that fits easily
refrigerants. The conversion kit in your truck. Each kit con-
ends the hassle of replacing ex- tains 168 conversion nozzles
isting refrigerant distributors to handle all your display case
in a multi-circuited refrigerat- requirements.
ed display fixture. Gone is the
irritation of cutting distributor Additional nozzles are sold in
tubes and soldering them back packs of six or twelve. The
together. With the Sporlan Con- Sporlan Conversion Nozzle
version Nozzle Kit, Kit is convenient — there’s no
you simply discon- need to stock unnecessary
nect the distributor distributors. The nozzles fit
from the expansion both replaceable and non-
valve, insert the replaceable nozzle type dis-
properly sized con- tributors.
version nozzle, and
reconnect the dis- A nozzle selection chart at-
tributor. That’s all tached to the lid of the carry-
there is to it. The ing case helps you select the
conversion is finished faster best orifice for the job. Sporlan
and you have more time to also provides a handy mail-
work on other jobs. back response card to keep you
up-to-date on all new refriger-
Sporlan has engineered the ants and the orifice sizes best
conversion nozzles with specific suited for them.
orifice sizes for maximum
refrigerant distribution and See your Authorized Sporlan
proper pressure drop. Dual “O” Wholesaler to order your Con-
rings on each nozzle ensure a version Nozzle Kit — a labor
tight fit with no leakage. saving device from Sporlan.

Sporlan's innovative Conversion Nozzle is a gold medal winner in


HVAC Magazine's 1992 Design Awards contest. The "unique" nozzle won
the gold for its ability to easily convert multi-circuited cases from R-12
or R-502 to R-22.
Bulletin 20-10-1, June 2001 supersedes Bulletin 20-10-1, September 1992 and all prior publications.
Page 2 / BULLETIN 20-10-1

NOZZLE SELECTION
REFRIGERANT HCFC-22
Evaporator Temperature (°F)
Evaporator
–20°F 0°F 10°F 20°F 30°F
Capacity
Liquid Temperature (°F)
(BTU/HR)
80 60 40 20 80 60 40 20 80 60 40 80 60 40 80 60 40
2000 1/4 1/6 1/9 1/9 1/4 1/6 1/9 1/9 1/6 1/9 1/9 1/6 1/9 1/9 1/6 1/9 1/9
4000 1/2 1/3 1/6 1/6 1/3 1/4 1/6 1/6 1/3 1/4 1/6 1/3 1/6 1/6 1/4 1/6 1/6
6000 3/4 1/2 1/4 1/4 3/4 1/3 1/4 1/4 1/2 1/3 1/4 1/2 1/4 1/4 1/3 1/4 1/4
8000 1 3/4 1/3 1/4 3/4 1/2 1/4 1/4 3/4 1/2 1/4 3/4 1/3 1/4 1/2 1/4 1/4
10000 1-1/2 3/4 1/2 1/3 1 3/4 1/3 1/3 1 3/4 1/3 3/4 1/2 1/3 3/4 1/3 1/3
12000 1-1/2 1 3/4 1/2 1-1/2 3/4 1/2 1/2 1-1/2 3/4 1/2 1 1/2 1/2 1 1/2 1/2
14000 2 1-1/2 3/4 1/2 1-1/2 1 1/2 1/2 1-1/2 1 1/2 1-1/2 3/4 1/2 1 1/2 1/2
16000 2 1-1/2 3/4 1/2 2 1-1/2 3/4 1/2 1-1/2 1 3/4 1-1/2 3/4 3/4 1-1/2 3/4 3/4
18000 2-1/2 2 1 3/4 2 1-1/2 3/4 3/4 2 1 3/4 1-1/2 3/4 3/4 1-1/2 3/4 3/4

REFRIGERANT HFC-134a
Evaporator Temperature (°F)
Evaporator
–20°F 0°F 10°F 20°F 30°F
Capacity
Liquid Temperature (°F)
(BTU/HR)
80 60 40 20 80 60 40 20 80 60 40 80 60 40 80 60 40
2000 1/2 1/3 1/6 1/9 1/2 1/4 1/9 1/9 1/3 1/4 1/9 1/3 1/6 1/9 1/4 1/9 1/9
4000 1 3/4 1/3 1/6 3/4 1/2 1/4 1/6 3/4 1/2 1/4 3/4 1/3 1/6 1/2 1/4 1/6
6000 1-1/2 1 1/2 1/4 1-1/2 3/4 1/4 1/4 1 3/4 1/4 1 1/2 1/4 3/4 1/3 1/4
8000 2 1-1/2 3/4 1/3 1-1/2 1 1/3 1/3 1-1/2 1 1/3 1-1/2 3/4 1/3 1 1/2 1/3
10000 2-1/2 2 1 1/2 2 1-1/2 1/2 1/2 2 1 1/2 1-1/2 3/4 1/2 1-1/2 1/2 1/2
12000 3 2 1 3/4 2-1/2 1-1/2 3/4 1/2 2 1-1/2 3/4 2 1 3/4 1-1/2 3/4 3/4
14000 3 2-1/2 1 3/4 2-1/2 2 3/4 3/4 2-1/2 1-1/2 3/4 2 1-1/2 3/4 2 3/4 3/4
16000 4* 2-1/2 1-1/2 3/4 3 2 3/4 3/4 2-1/2 2 3/4 2-1/2 1-1/2 3/4 2 3/4 3/4
18000 4* 2-1/2 1-1/2 1 4* 2 1 3/4 3 2 1 2-1/2 1-1/2 1 2-1/2 1 1
*#4 nozzle not available in kit.
Nozzle selections assume a pulldown load equivalent to twice the evaporator rating. For nozzle selections with other
refrigerants, please contact your local Sporlan Sales Office, or Sporlan Valve Company, Washington, Missouri.

SELECTION
Distributor Conversion Nozzle Type Nozzle Size Bolt
To correctly select a conversion
Type (Specify Orifice Size) Available (Not Supplied)
nozzle the following requirements
must be known: 1603
1. Refrigerant in the system 1606
T
2. Evaporator Capacity (BTU/HR) 1650 1/9 1/4
1650R Through 20 Thread
3. Evaporator Temperature (°F)
D115 3
4. Liquid Temperature (°F) V
D116
5. Distributor Type
1652
1652R
EXAMPLE 1654
W
1/6 3/8
Refrigerant in the system is R-22 1654R Through 16 Thread
Evaporator Capacity = 1656 3
1656R
10000 BTU/HR
Evaporator Temperature = 10°F
Liquid Temperature = 80°F
Non-Replaceable Nozzle
Distributor Type is 1650
Conversion Nozzle
Bolt
From the selection chart based on (Not Supplied)
above information choose a T-1
conversion nozzle. Note: If
capacities fall between values on
the selection chart, select the lower
"O" Ring (2 places)
conversion nozzle.

© 2001 BY SPORLAN VALVE COMPANY, 206 LANGE DRIVE, WASHINGTON, MO


5-601 636-239-1111 • FAX 636-239-9130 Printed in U.S. of A.