Submitted by:
1. Ahmed Bin Mustafa 15-28526-1
Group Members:
2. Bayzid Ahmed 18-39068-3
3. Atiya,Mst.Nurey Chomon 17-33371-1
4. Md. Ruhul Amin 18-39081-3
5.Hridoy, MD.Mohibul Islam 18-39076-3
Faculty Comments :
Total Marks :
Marks Obtained :
Date of performance:08.03.20
Abstract: The Split Phase Motor is also known as a Resistance Start Motor. It has a single cage
rotor, and its stator has two windings known as main winding and starting winding. At the
starting of the motor both the windings are connected in parallel. A single phase induction motor
cannot produce a rotating torque. So in order to start the motor by increasing the starting torque
capacitor is used. Answer. A capacitor is used to develop starting torque by creating a phase shift
between the currents.
Introduction: The single-phase induction motor is called the split-phase induction motor, which
is fitted with an auxiliary winding from and connected in parallel with a main running winding.
The Split Phase Motor is also known as a Resistance Start Motor. It has a single cage rotor, and
its stator has two windings known as main winding and starting winding. Both the windings are
displaced 90 degrees in space. The main winding has very low resistance and a high inductive
reactance whereas the starting winding has high resistance and low inductive reactance.
Ideally in a two-winding machine, there will be two windings with equal mmf magnitudes, a 90°
electrical phase angle between the winding currents and a 90° (electrical) physical angle between
windings. Usingknowledge of three-phase induction machines, the impedance of a winding is a
function of slip. This adds additional complexity if two balanced winding currents are to be
obtained from a single phase supply.If the current in the auxiliary winding must lead the main
winding current, capacitance must be added to theauxiliary winding. However, if the resistance
and inductance of the windings changes with slip, thecapacitance required to maintain equal
mmfs and 90° phase shift must also change[1].In a Capacitor-Start Motors, in these motors, the
necessary phase difference between Is and Im is producedby connecting acapacitor in series with
the starting winding as shown in Fig.1. The capacitor is generally of the electrolytic type and is
usually mounted on the outside of the motor as a separate unit as shown in Fig.2.The capacitor is
designed for extremely short-duty service and is guaranteed for not more than 20 periods of
operation per hour, each period not to exceed 3 seconds. When the motor reaches about 75
percent of full-load speed, the centrifugal switch S opens and cuts out both the starting winding
and the capacitor from the supply, thus leaving only the running winding across the lines.As
shown in Fig.3, current Im drawn by the main winding lags the supply voltage V by a large angle
whereas Is leads V by a certain angle. The two current are out of phase with each other by about
180o(for a 200 W, 50 Hz motor) as compared to nearly 30ofor a split-phase motor[2].
Figure 1: windings diagram[2] Figure 2: Capacitor Start motor[2] Figure 3: Vector diagram[2]
In split phase motor two windings named as main winding and starting winding are provided. At
the time of starting, both the main and starting windings should be connected across the supply
to produce the rotating magnetic field.The rotor is of a squirrel cage type and the revolving
magnetic field sweeps part the stationary rotor, inducing emf in the rotor. As the rotor bars are
short-circuited, a current flows through them producing a magnetic field.This magnetic field
opposes the revolving magnetic field and will combine with the main filed to produce a
revolving filed. By this action, the rotor starts revolving in the same direction of the rotating
magnetic field as in the case of a squirrel cage induction motor.Hence, once the rotor starts
rotating, the starting winding can be disconnected from the supply by some mechanical means as
the rotor and stator fields from a revolving magnetic field. There are several types of split phase
motors[3].A centrifugal switch (C.S) is connected in series with the starting winding as shown in
the diagram and its function is to disconnect automatically when motor achieved 70% to 80% of
its full load speed.Centrifugal switch is used often motor rating is about 100W or above and for a
small motor, the relay is used.A typical torque-speed characteristic of the split phase induction
motor is shown below. From the characteristics,it is observed that the starting torque of the
motor is 150% to 200% of full load torque and therefore starting current is 6 to 8 times of full
load current[4].
Figure 4: torque-speed characteristic of the split phase induction motor [4]
Apparatus:
DESCRIPTION MODEL
AC Ammeter 8425
AC Voltmeter 8426
Electrodynamometer 8911
Experimental Procedure:
Part A:
1. Power Supply was adjusted for an output of 150V AC to perform the Procedures in this
Laboratory Experiment.
b) Turned on the Power Supply and adjusted for an output of 150V AC as indicated by the
voltmeter. Did not touch the voltmeter output control for the remainder of this Laboratory
Experiment unless told to do so.
2. a) Connected terminals 1 and 2 of the main winding of the Capacitor-Start Motor, to terminals
A and N of the pre-adjusted 150V AC output of the Power Supply.
3. a) Loosened the top screws of the motor module’s front panel and lowered the panel.
4. a) Disconnected the main winding, terminals 1 and 2, from the Power Supply.
b) Connected the auxiliary winding, terminals 3 and 4, to the pre-adjusted 150V ac output of the
Power Supply terminals 4 and N.
5. a) Connected the main winding, terminals 1 and 2, in parallel with the auxiliary winding,
terminals 3 and 4.
b) Connected the parallel windings to the pre-adjusted 150V ac output of the Power Supply.
8. a) Turned on the Power Supply switch. The output voltage control was kept at its 150V
setting.
f) Reduced the input voltage to 100V ac as indicated by the voltmeter and measured the running
speed. g) Returned the voltage to 100V ac and turned off the Power Supply.
9. Connected the circuit shown in Figure 1-2. Noted that both windings are connected in parallel
and that the centrifugal switch was in series with the parallel connected motor windings and the
150V ac Power Supply terminals 4 and N.
Figure 6: both windings connected in parallel [2]
11. a) Closed the Power Supply switch and noted what happened.
d) Returned the voltage to zero and turned off the Power Supply.
Part B:
1. Using your Capacitor-Start Motor, Power Supply, AC Ammeter and AC Voltmeter connect
the circuit shown in figure 10-1. Note that the fixed 240 V ac output of the Power Supply
terminals 1 and N is being used.
Figure 7: Main winding connected [2]
2. Turn on the Power Supply switch and measure the current through the main windings as
quickly as possible -within 10 seconds. I (main winding) =
3. a) Disconnect your leads from the main winding and connect them to the auxiliary winding
terminals 3 and 4 as shown in figure.
c) Connect the Electrodynamometer to the fixed 240V ac output of the Power Supply terminals 1
and N. d) Set the Electrodynamometer control knob at its full cw position ( to provide a
maximum starting load for the Capacitor-Start Motor). e) Turn on the Power Supply switch and
measure the starting current as quickly as possible- within 10 seconds. I (starting) =
No-load Operation
5. Using your Single-Phase Wattmeter AC Ammeter and AC Voltmeter connect the circuit
shown in Figure 10-4. 4 N AC 1 3
Figure 8: Single-Phase Wattmeter connected [2]
6. a) Turn on the Power Supply and adjust for 240V ac as indicated by the voltmeter across the
motor.
b) Measure and record in Table 10-1 the line current, the power and motor speed. Note and
record the relative motor vibration
E I P SPEED VIBRATION
V A W r/min
220 1.9 50 1491 yes
180 1.4 30 1495 yes
120 1 15 1489 yes
60 0.6 5 1414 no
c) Repeat (b) for each of the input voltages listed in the table.
d) Return the voltage to zero and turn off the Power Supply
Full-load Operation
7. a) Couple the Electrodynamometer to the Capacitor-Start Motor with the Timing Belt.
b) Connect the input terminals of the Electrodynamometer to the fixed 240V ac output of the
Power Supply terminals 1 to N.
c) Set the Electrodynamometer control knob at its full cw position (to provide a maximum
starting load for the Capacitor-Start Motor). d) Turn on the Power Supply and adjust for 240V
ac.
e) Measure and record in Table 10-1 the line current, the power and motor speed.
f) Repeat (e) for each of the torques listed in the table maintaining the input voltage at 240V ac.
g) Return the voltage to zero and turn off the Power Supply.
8. a) Calculate and record in the table the apparent power (in VA) delivered to the motor for each
of the listed torques.
b) Calculate and record in the table the output power Pout for each of the listed torques. Use the
formula Pout = 2πNT/60
9. You will now determine the maximum starting torque developed by the Capacitor Start Motor.
a) Disconnect the Single-Phase Wattmeter, AC Ammeter and AC Voltmeter form your circuit.
b) Connect the input of your Capacitor-Start Motor to terminals 2 and N of the Power Supply
(fixed 240V ac).
c) Set the Electrodynamometer control knob at its full cw position (for maximum loading).
d) Turn on the Power Supply switch and quickly measure the developed torque on the
Electrodynamometer scale. Turn off the Power Supply switch.
Discussion: The starting winding current (Is) lag behind applied voltage V by small angle while
main winding current (Im) lag behind applied voltage V by a very large angle. The phase angle
between starting winding current (Is) and main winding current (Im) is made as large as possible
because of starting torque of split phase induction motor is directly proportional to the sin angle
between Is and Im.
Conclusion: While the generator is synchronized, the frequency of the system will change
depending on load and the average characteristics of all the generating units connected to the
grid [1]. Large changes in system frequency can cause the generator to fall out of synchronism
with the system. Protective devices on the generator will operate to disconnect it automatically.
Reference:
[1].https://people.ucalgary.ca/~aknigh/electrical_machines/other/split_phase.html
[2].AIUB lab manual
[3].http://www.brainkart.com/article/Principle-and-Working-of-Split-Phase-Induction-
Motor_12261/
[4].https://nakshelectrical.blogspot.com/2019/04/split-phase-induction-motor.html?m=1