PRESSURE REDUCING
VALVES EUROPRESS
ITAP SpA, founded in Lumezzane
(Brescia) in 1972, is currently one of
the leading production companies in
Italy of valves, fittings and distribution
manifolds for plumbing and heating
systems. Thanks to fully automated
production processes, with 72 tooling
machines and 51 assembly lines, we are
able to produce 200,000 pieces per day.
Our innate pursuit for innovation and
observance of technical regulations is
supported by the company certification
ISO 9001: 2008. The company has always
considered its focus on quality as the
main tool to obtain significant business
results: today ITAP SpA is proud to
offer products bearing the approval
of numerous international certifying
bodies.
THE COMPANY
TEC
E
uropress pressure reducing
valve is a device which reduces
and stabilizes the upstream
pressure to an adjusted downstream
pressure.
When the entering pressure from the
public mains is too high and variable,
pressure reducing valve stabilizes
the downstream pressure to the
adjusted one. Possible variations of the
upstream pressure do not influence
the adjusted downstream pressure.
This range of pressure reducing valves
allows the operator to adjust the
EUROPRESS
downstream pressure to a set figure.
OVERALL
DIMENSIONS
PRESSURE REDUCING VALVES EUROPRESS
B
C
F F
DN 15 20 25 32 40 50 65 80 100
F 12 12 13 18 18 20 20 22 23,5
Kg/cm2 bar 25 25 25 25 25 25 25 25 25
LBS - psi 362,5 362,5 362,5 362,5 362,5 362,5 362,5 362,5 362,5
MATERIALS
TEC
FROM 1/2” TO 1”
14
13
12 11
10
9
7 15
2 1
6
3
4 5
4 O-Ring 1 EPDM
EUROPRESS
Shutter 1 Brass CW614N
8 O-Ring 1 EPDM
9 O-Ring 1 EPDM
12 Spring 1 EN 10270-1 DH
13 Nut 1 Nylon
15 Cap 2 POM
MATERIALS
FROM 1”1/4 TO 4”
17
16
15
14
13
12
11
10
9 18
8
7
6
4
1
3
5
2
3 O-Ring 1 NBR
5 O-Ring 1 NBR
10 O-Ring 1 NBR
12 O-Ring 1 NBR
16 Nut 1 Nylon
18 Cap 2 POM
CERTIFICATIONS
1/2” - 3/4”
TEC
143MM
EUROPRESS SIZE PRESSURE CODE PACKING
OVERALL
DIMENSIONS
EUROPRESS
B
C
F F
DN 15 20 25 32 40 50
C 40 40 59 69,5 126 87
F 12 12 14 16 16 17
Kg/cm2 bar 25 25 25 25 25 25
11
10
9
7 17
8 18
16
2
1
6
4 5
15
PRESSURE REDUCING VALVES EUROPRESS
4 O-Ring 1 EPDM
8 O-Ring 1 EPDM
9 O-Ring 1 EPDM
12 Spring 1 EN 10270-1 DH
13 Nut 1 Nylon
15 Cap 2 Nylon
15
14
13 9
12
1
19
11
10
8
21
7
20 6
4
3
18
EUROPRESS
1 Body 1 Nickel-plated brass CB753S
3 O-Ring 1 NBR
5 O-Ring 1 NBR
10 O-Ring 1 NBR
12 O-Ring 1 NBR
16 Nut 1 Nylon
18 Cap 2 Nylon
CERTIFICATIONS
1/2” - 3/4”
PRESSURE DROP WITH WATER
CHART
Here mentioned figures refer to: upstream pressure 8 bar, downstream pressure 3 bar.
N.B. Figure about 4” are approximate.
PRESSURE REDUCING VALVES EUROPRESS
2 1/2”
1/2”
3/4”
1 1/4”
1 1/2”
1”
2”
3”
4”
1.5
1
0.9
0.8
Pressure drop [Bar]
0.7
0.6
0.5
0.4
200
300
400
500
700
1000
2000
1 2 3 4 5 6 7 8 9 10 20 30 40 50 70 100
Flow rate [l/min]
Instruction on installation
1. Before installing the pressure reducing valve, open all the outlets to flush
the system and expel any air left in piping
2. Install shut-off valves upstream and downstream to facilitate
maintenance operations
3. For a right flow direction, use the arrow stamped on the body
4. ITAP pressure reducing valve can be installed in either vertical or
horizontal piping. It can be installed also upside down
5. Art. 143 is equipped with a threaded connection suitable for a pressure
gauge. It is possible to unscrew the plug made in order to install a pressure
gauge in the size of 1/4”. In such a position, the pressure gauge shows the
EUROPRESS
downstream pressure of the reducing valve.
6. The whole range of ITAP pressure reducing valves are tested and
adjusted with a downstream pressure of 3 bar. It is possible to change the
downstream pressure by means of the adjusting device.
Troubleshooting
Increase in pressure downstream on the pressure reducing valve with a water
heater in-line. This problem is due to heating of the water, caused by the water
heater. The pressure downstream increases, due to water expansion, as the
pressure reducing valve is correctly closed. It is necessary to install an expansion
vessel between the pressure reducing valve and the water heater to absorb the
pressure increase (Fig. 5.1).
PRESSURE REDUCING VALVES EUROPRESS
FIG. 5.1
The pressure reducing valve does not maintain the adjusted figure
In most cases, this problem is due to the presence of impurities on the valve seat,
causing blow-by and consequent increase in the downstream pressure.
Install an Y-strainer upstream of the pressure reducing valve.
Carry-out the maintenance of the Y-strainer.
Flush the water system before installing the pressure reducing valve.
Flow direction
FIG. 5.2
NOTES
EUROPRESS
We reserve the right to make improvements and changes to the products described herein and
to the relative technical data, at any time and without forewarning.
ITAP S.p.A.
Via Ruca 19
25065 Lumezzane
Brescia (ITALIA)
09/2016