Fraunhofer Institut für Bauphysik

Table 1 GF Hakan Plastik. Measurements of April 5, 2018. Sound pressure levels measured in the
installation test facility. Test object was the wastewater system "GF HAKAN SiLENTA
PREMIUM LOW NOISE PIPE 110x5.3, PP, 13/01/18" (manufacturer: GF Hakan Plastik). The
wastewater system consisted of straight plastic pipes and fittings and pipe clamps with
elastic inlay "GF hakan 4’’ 110-119,116-125, with spacer 7 mm" (manufacturer: GF Hakan
Plastik). In every storey (EG and UG) two clamps were installed (details see figure 2). The
basement bend consisted of 2 x 45° bends.

Wastewater system "GF HAKAN SiLENTA PREMIUM LOW NOISE Flow rate [l/s]
PIPE 110x5.3, PP, 13/01/18" (manufacturer: GF Hakan Plastik).
The wastewater system consisted of straight plastic pipes and
fittings and pipe clamps with elastic inlay "GF hakan 4’’ 110-
119,116-125, with spacer 7 mm" (manufacturer: GF Hakan 0.5 1.0 2.0 4.0
Plastik). In every storey (EG and UG) two clamps were installed
(details see figure 2). The basement bend consisted of 2 x 45°
bends.

Airborne sound pressure level La,A [dB(A)]


UG front 40 44 47 50
according to EN 14366 in the basement test-room

Structure-borne sound characteristic level Lsc,A [dB(A)] <10 <10 <10


UG rear 13
according to EN 14366 in the basement test-room (-2) (3) (8)

UG front 40 44 47 50
Installation sound level LAFeq,n [dB(A)] following
DIN 4109 measured in the basement test-room <10 <10
UG rear 12 16
(2) (7)

UG front 37 42 45 48
Installation sound level ̅̅̅̅̅̅̅̅̅
LAFeq,nT [dB(A)] following
VDI 4100 measured in the basement test-room <10 <10 <10
UG rear 13
(-2) (4) (8)

This information does not represent a proof for the sound-related suitability of the examined products.
Only a test report with detailed description of the proofed items and the measuring procedure can
provide this certification. Please notice that the results should be used only internally. It is not allowed to
use the results in your advertising without our permission.
Fraunhofer Institut für Bauphysik

Figure 1 GF Hakan Plastik. Measurements of April 5, 2018. Test set-up for the wastewater system "GF
HAKAN SiLENTA PREMIUM LOW NOISE PIPE 110x5.3, PP, 13/01/18" (manufacturer: GF Hakan
Plastik). The wastewater system consisted of straight plastic pipes and fittings and pipe clamps
with elastic inlay "GF hakan 4’’ 110-119,116-125, with spacer 7 mm" (manufacturer: GF
This information does
Hakan notPlastik).
represent a proof
In each for (EG
storey the and
sound-related suitability
UG) respectively oneof the examined
double clamp was products.
installed at the
Only a test report lower
with detailed
wall area description of the clamp
and one single proofedat items and the
the upper wallmeasuring procedure
area. To reduce can to the pipe,
contact
provide this certification.
the singlePlease notice
clamp andthat
the the
lowerresults
part should
of the be used clamp
double only internally. It is notwith
were mounted allowed
7 mm to space
use the results in your advertising
between without
the locking tabs our permission.
of the clamp (one 7 mm spacer on each side). The clamps were fixed
to the installation wall with dowels and thread rods (figure 2).
Fraunhofer Institut für Bauphysik

Figure 2 GF Hakan Plastik. Measurements of April 5, 2018. Test object was the wastewater system
"GF HAKAN SiLENTA PREMIUM LOW NOISE PIPE 110x5.3, PP, 13/01/18" (manufacturer: GF
Hakan Plastik). The wastewater system consisted of straight plastic pipes and fittings and
pipe clamps with elastic inlay "GF hakan 4’’ 110-119,116-125, with spacer 7 mm"
(manufacturer: GF Hakan Plastik). In each storey (EG and UG) respectively one double clamp
was installed at the lower wall area (lower picture) and one single clamp at the upper wall
This information does
areanot represent
(upper a proof
picture). for the
To reduce sound-related
contact suitability
to the pipe, of clamp
the single the examined
and the products.
lower part of the
Only a test report with detailed description of the proofed items and the measuring
double clamp were mounted with 7 mm space between the locking tabs of theprocedure can clamp (one
provide this certification. Please notice that the results should be used only internally. It is not
7 mm spacer on each side). The clamps were fixed to the installation wall with dowelsallowed to and
use the results in your advertising without our permission.
thread rods. The basement bend consisted of 2 x 45° bends.