Sei sulla pagina 1di 4

Order Information Submitted

Order ID Submitted By Original Submit Date JDE Job Number Revision Number
470773 Erin O'Toole Jun 13 2019 546893 0
Orders are subject to applicable Crown Castle engineering, regulatory, zoning/planning, and priority property-owner approval. Approval conditions may result in alternative
requirements for type and/or placement of equipment. Approval conditions may also lead to additional or revised engineering analysis at Crown Castle discretion and upon
consent of the customer.

Site Information
Site ID Crown Castle Structure Structure Height (ft) Crown Castle Site Name
824218 A 75.0 Gendells Auto Repair
Crown Castle District County
CHI Wayne
Latitude Longitude Structure Type Site Address
42° 25' 52.10" -83° 9' 41.40" MONOPOLE 10031 W 7 Mile Road
Detroit, MI 48221

Order Parameters
Who is the customer? What do you want to do? License Number What is the Scope of your Order?
T-Mobile Amend a License 526541 Tower Equipment
Are you changing a mount?
--
What is the scope of work?
T-MOBILE L600

retain (4) antennas; add (5) antennas


removing diplexers to ground
removing (4) radios, add (3) AHLOA radios, (1) ovp box
add (6) coax cables; remove existing hybrid cable; add (2) hybrid cables

FINAL CONFIG: (6) ANTENNAS, (11) RADIOS, (2) OVP BOXES, (2) HIGH CAP
HYBRID CABLE

Customer
Billing Company Billing ID Number Billing Address
T-Mobile 115039 12920 SE 38TH STREET
BELLEVUE, WA 98006
Operating Legal Entity Operating Legal Entity ID
T-Mobile Central LLC 470052
T-Mobile Site Name T-Mobile Site ID T-Mobile Market T-Mobile Region
-- DE01304B DETROIT CENTRAL
Project Management Vendor
Crown Castle - PMV

Contacts
NAME EMAIL PHONE ADDRESS

MacKenzie Keys cr.crown@t-mobile.com x x


xx

RF Contacts
NAME EMAIL PHONE

Page 1
Configuration Review
Antennas
MCL ACL TOTAL INSTALLED PROPOSED NOT MANUFACTURER / MODEL HEIGHT WIDTH DEPTH WEIGHT
(ft) (ft) INSTALLED (in) (in) (in) (lbs)

76 77 4 4 0 0 ANDREW / TMBXX-6517-R2M 74.90 12.00 6.50 44.40


77 2 0 2 0 ANDREW / TMBXX-6517-R2M 74.90 12.00 6.50 44.40
77 3 0 3 0 COMMSCOPE / FFHH-65C-R3 95.90 25.20 9.30 127.60

Tower Mounted Equipment


MCL ACL TOTAL INSTALLED PROPOSED NOT MANUFACTURER / MODEL TYPE HEIGHT WIDTH DEPTH WEIGHT
(ft) (ft) INSTALLED (in) (in) (in) (lbs)

76 76 3 3 0 0 COMMSCOPE / AMPLIFIER 9.10 8.70 4.10 17.60


TMAT1921XB68-21A
76 78 2 2 0 0 NOKIA / FHFB BASE 34.30 12.60 7.80 52.90
STATION
76 76 2 2 0 0 NOKIA / FHFB BASE 34.30 12.60 7.80 52.90
STATION
76 77 3 3 0 0 NOKIA / FRIG BASE 18.90 15.20 6.00 57.32
STATION
76 76 1 1 0 0 NOKIA / FRIJ BASE 23.10 12.60 4.84 44.10
STATION
76 76 1 1 0 0 RAYCAP / RNSNDC-7771- JUNCTION 20.38 18.86 5.83 19.00
PF-48 BOX
77 3 0 3 0 NOKIA / AHLOA BASE 22.05 12.13 7.44 83.80
STATION
77 1 0 1 0 RAYCAP / ASU9338TYP01 JUNCTION 20.38 18.86 5.83 19.00
BOX

Feedlines
MCL ACL TOTAL INSTALLED PROPOSED NOT MANUFACTURER / MODEL NOMINAL SIZE NOMINAL O.D.
(ft) (ft) INSTALLED (in) (in)

76 78 6 6 0 0 ANDREW / LDF5-50A 7/8 1.03


78 2 0 2 0 NOKIA / ASU9325TYP01 1-3/5 1.58

Frequencies
SVC TECHNOLOGY EIRP (WATTS) STANDARD FREQUENCY TRANSMIT FREQUENCY

LTE 1000.00 668.000 - 678.000MHZ


678.000 - 688.000MHZ
LTE 1000.00 693.000 - 698.000MHZ
728.500 - 746.500MHZ
LTE 1000.00 1930.000 -1990.000MHZ
2110.000 -2130.000MHZ
All Receive frequencies are approved.

Cabinets
Number of Proposed Additional Cabinets
0

Lease Areas
There are currently no Lease Areas for this order

Power
Do you need Crown to supply Power?
No
Battery Backup Required?
No

Page 2
Equipment Order autopopulated from LMP(Installed Config)
Antennas
MANUFACTURER / MODEL ANTENNA AZIMUTH CUSTOMER MOUNT STATUS
CENTERLINE MOUNT CLASS ORIENTATION
(ft)

ANDREW / TMBXX-6517-R2M 77 120 PLATFORM Mid-Mount Installed


MOUNT
ANDREW / TMBXX-6517-R2M 77 120 PLATFORM Mid-Mount Installed
MOUNT
ANDREW / TMBXX-6517-R2M 77 300 PLATFORM Mid-Mount Installed
MOUNT
ANDREW / TMBXX-6517-R2M 77 300 PLATFORM Mid-Mount Installed
MOUNT
ANDREW / TMBXX-6517-R2M 77 30 PLATFORM Mid-Mount Proposed
MOUNT
ANDREW / TMBXX-6517-R2M 77 30 PLATFORM Mid-Mount Proposed
MOUNT
COMMSCOPE / FFHH-65C-R3 77 30 PLATFORM Mid-Mount Proposed
MOUNT
COMMSCOPE / FFHH-65C-R3 77 120 PLATFORM Mid-Mount Proposed
MOUNT
COMMSCOPE / FFHH-65C-R3 77 300 PLATFORM Mid-Mount Proposed
MOUNT

Tower Mounted Equipment


TYPE MANUFACTURER / MODEL TME CENTERLINE LOCATED ON MOUNT CLASS STATUS
(ft) ANTENNA MOUNT?

JUNCTION RAYCAP / RNSNDC-7771-PF-48 76 Yes Installed


BOX
AMPLIFIER COMMSCOPE / TMAT1921XB68-21A 76 Yes Installed
AMPLIFIER COMMSCOPE / TMAT1921XB68-21A 76 Yes Installed
AMPLIFIER COMMSCOPE / TMAT1921XB68-21A 76 Yes Installed
BASE NOKIA / FHFB 76 Yes Installed
STATION
BASE NOKIA / FHFB 76 Yes Installed
STATION
BASE NOKIA / FHFB 78 Yes Installed
STATION
BASE NOKIA / FHFB 78 Yes Installed
STATION
BASE NOKIA / FRIJ 76 Yes Installed
STATION
BASE NOKIA / FRIG 77 Yes Installed
STATION
BASE NOKIA / FRIG 77 Yes Installed
STATION
BASE NOKIA / FRIG 77 Yes Installed
STATION
BASE NOKIA / AHLOA 77 Yes Proposed
STATION
BASE NOKIA / AHLOA 77 Yes Proposed
STATION
BASE NOKIA / AHLOA 77 Yes Proposed
STATION
JUNCTION RAYCAP / ASU9338TYP01 77 Yes Proposed
BOX
Page 3
Feedlines
TYPE MANUFACTURER / MODEL NOMINAL SIZE ATTACHED LENGTH IN CONDUIT? STATUS
(in) CENTERLINE (ft)
(ft)

COAX ANDREW / LDF5-50A 7/8 78 128 No Installed


COAX ANDREW / LDF5-50A 7/8 78 128 No Installed
COAX ANDREW / LDF5-50A 7/8 78 128 No Installed
COAX ANDREW / LDF5-50A 7/8 78 128 No Installed
COAX ANDREW / LDF5-50A 7/8 78 128 No Installed
COAX ANDREW / LDF5-50A 7/8 78 128 No Installed
HYBRID NOKIA / ASU9325TYP01 1-3/5 78 128 No Proposed
HYBRID NOKIA / ASU9325TYP01 1-3/5 78 128 No Proposed

NOTICE: Structural Analysis shall be performed in accordance with the current revision of the TIA/EIA 222 standard and applicable local building permit codes and standards.
EME analysis shall be consistent with current revision of FCC/OSHA standard OETB 65. AM detuning, when required, will be performed to 47 CFR22.371. The customer
is responsible for all analysis expenses. All construction drawings are subject to Crown Castle engineering approval prior to commencement of tower attachments and
compound installations. Installation of equipment not conforming to approved drawings may violate the terms of the occupancy agreement and will be corrected at the
customer's expense. Crown Castle requires drawings for pre-construction approval and as built drawings for physical configuration validation to be submitted as unlocked
AutoCAD files (Version 2000i preferred). Because manufacturers may change equipment specifications (e.g., length, width, height, depth or weight) for a Model Number
without changing the Model Number itself, the equipment specifications for such Model Number as identified herein shall be used to determine exactly which version of
equipment with such Model Number is approved by Crown Castle herein. Crown Castle may include the suffix “CCIv” together with a number (indicating a version number)
after a Model Number, which suffix is not part of the actual Model Number, but indicative of a known change to the equipment specifications applicable to such Model Number.

Page 4