Sei sulla pagina 1di 2

Datos:

T 1=300° C+273,15 K =573,15 K

T 2=300° C+273,15 K =573,15 K

T 3=137° C+ 273,15 K =410 , 15 K

T 4=95° C+273,15 K=368 , 15 K

L A =20 x 10−3 m
K A =50,2W /mK

A1=π (75 x 10−3 m)2=17,67 x 10−3 m2

LB =7 x 10−3 m
K B=1 , 2W / mK
2
A2=2 π ( 4 5 x 10−3 m) ( 130 x 10−3 m) + π ( 45 x 10−3 m ) =43 , 1 x 10−3 m2
2
A=2 π ( 4 0 x 10−3 m ) ( 130 x 10−3 m ) +2 π ( 4 0 x 10−3 m ) =42 ,7 x 10−3 m2
Sin tener en cuenta la solución:

LA L 20 x 10−3 m 7 x 10−3 m K
RT ,0= + B = + =0,158
k A A 1 k B A 2 50,2 W −3 2 1,2W −3 2 W
( )(17,67 x 10 m ) ( )(43,1 x 10 m )
mK mK

T 1−T 3 573,15 K −410,15 K


q= = =1031,64 W
R T ,0 K
0,158
W
Con la solución:

LA LB 1 K 23,42
RT ,1= + + =0,158 +
k A A 1 k B A2 hA W h m2
Planteamos la ecuación:

T 1−T 4
q=
RT , 1
Reemplazamos:
573,15 K −368,15 K
1031,64 W =
K 23,42
0,158 +
W h m2

Despejando h:

24161W W
h= 2
=573,9 2
42,1 m K m K