Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
This standard has been approved for use by agencies ojrhe Department of Dejense. Consult the DOD Index of Speq$carions and
Standards/or lhe spec$c year of issue which has been adopred by the Department of DeJense.
ft!#D 3029
TABLE 1 Tup and Support Ring Dimensions ring as Test Method G, Geometry GA. (See 16. I and Table
Test Method F 1.)
Dimensions, mm (in.) 5.3 Test Method F, Geometry FB, causes a greater stress
Geometry Inside Diameter
concentration and results in failure of tough or thick
Tup Diameter
Support Ring specimens that do not fail with Geometry FA (3). This
FA 15.86 f 0.10 76.20 f 1.6
approach causes a punch shear type of failure on thick sheet
(0.625 + 0.004) (3.00 f 0.06) similar to that discussed in 4.5. If this is undesirable,
FB 12.7 f 0.1 36.1 rt 0.8 Geometery FC may be used. Because of the smaller test area,
(0.500 f 0.003) (1.5 It 0.03)
127.0 i 2.5
it is more suitable for research and development.
FC 38.1 f 0.4
(1.5 + 0.010) (5.00 + 0.10) 5.3. I The conical configuration of the 12.7-mm diameter
tup used in Geometry FB minimizes problems with tup
Test Method G penetration and sticking in failed specimens of some ductile
GA 15.86 f 0.10 76.20 + 0.25
materials.
(0.625 -c 0.004) (3.00 f 0.01) 5.4 The test conditions of Test Method F, Geometry FC,
GB 15.86 + 0.10 31.75 + 0.025 are the same as those of Method A of Test Methods D 1709.
(0.625 + 0.004) (1.25 zt 0.001)
16.26 f 0.025
They have been used in specifications for extruded sheeting.
GC 15.86 k 0.10
(0.625 + 0.004) (0.640 k 0.001) A limitation of this geometry is that considerable material is
required.
5.5 The test conditions of Test Method G, Geometry GB
dropped from a fixed height. (See Fig. 1.) are equivalent to the geometry used for the Gardner Variable
4.3 In Test Method G (Sections 16 to 24), a weight falls Height Impact Test (4). It requires about the same amount of
through a guide tube and strikes an impactor resting on top material as Test Method F, Geometry FB.
of a supported specimen. The fixed weight is dropped from 5.6 The test conditions of Test Method G, Geometry GC
various heights. (See Fig. 4.) cause a punch-shear type of failure because the support-plate
4.4 Either procedure determines the energy (mass X hole is close to the diameter of the impactor.
height) that will cause 50 % of the specimens tested to fail 5.7 Because of the nature of impact testing, the selection
(mean failure energy). of a test method and tup must be somewhat arbitrary. While
4.5 The technique used to determine mean failure energy any one of the tup geometries may be selected, knowledge of
is commonly called the Bruceton Staircase Method, or the the final or intended end-use application should be consid-
Up-and-Down Method (I). I0 Testing is concentrated near ered.
the mean, reducing the number of specimens required to 5.8 Clamping of the test specimen will improve the
obtain a reasonably precise estimate of the impact resistance. precision of the data. Therefore, clamping is recommended.
4.6 Each test method permits the use of different tup and However, with rigid specimens valid determinations can be
test specimen geometries to obtain different modes of failure, made without clamping. Unclamped specimens tend to
permit easier sampling, or test limited amounts of material. exhibit somewhat greater impact resistance.
There is no known means for correlating the results of tests 5.9 For many materials, there may be a specification that
made by different methods or procedures. requires the use of this test method, but with some proce-
dural modifications that take precedence when adhering to
5. Significance and Use the specification. Therefore, it is advisable to refer to that
5.1 Plastics are viscoelastic and therefore may be sensitive material specification before using this test method. Table 1
to changes in velocity of weights falling on their surfaces. of Classification System D 4000 lists the ASTM materials
However, the velocity of a free-falling object is dependent on standards that currently exist.
the square root of the drop height. A change of a factor of
two in the drop height will cause a change of only 1.4 in 6. Interferences
velocity. Hagan, et al (2) found that the mean failure energy
6. I Falling-weight impact test results are dependent on
of sheeting was constant at drop heights between 0.30 and
the geometry of both the falling weight and the support.
1.4 m. This suggests that a constant weight-variable height
Thus, impact tests should be used only to obtain relative
method will give the same results as the constant height-
rankings of materials. Impact values cannot be considered
variable weight technique. On the other hand, different
absolute unless the geometry of the test equipment and
materials respond differently to changes in the velocity of
specimen conform to the end-use requirement. Data ob-
impact. Equivalence of these test methods should not be
tained by different procedures within this test method, or
taken for granted. While both constant-weight and constant-
with different geometries, cannot, in general, be compared
height techniques are permitted by these test methods, Test
directly with each other. However, the relative ranking of
Method F, using a fixed height, should be used for those
materials may be expected to be the same between two test
materials that are found to be rate-sensitive in the range of
methods if the mode of failure and the impact velocities are
velocities encountered in falling-weight types of impact tests.
the same.
5.2 The test geometry used in Test Method F, Geometry
6.1. I Falling-weight impact types of tests are not suitable
FA, employs the same tup nose diameter and sample support
for predicting the relative ranking of materials at impact
velocities differing greatly from those imposed by these test
lo The boldface numbers in parentheses refer IO the list of references at the end
methods.
of these test methods. 6.2 As cracks usually start at the surface opposite the one
2
ASTM D3029 94 - 0759530 0556737 670 -
38.fd 0. 4mm.
(A500 i O.O//*.)
QEOMETRY C
CLAMP
76.20 ;L/.& mm
- SPEC I MEA’
GEOAQt- TR Y A
STAT/WVARY
CLAMP
(5.00 22 O./OWL)
GEOmt?TRY c
FIG. 1 One Type of Drop Weight Impact Tester Used for Test Method F
that is struck, the results obtained can be greatly influenced sensitive to temperature. This test can be carried out at any
by the quality of the test specimens. Therefore, the composi- reasonable temperature and humidity, thus representing
tion of this surface layer and the degree of orientation actual use environments. However, this test method is
introduced during the formation of the specimen (such as intended primarily for rating materials under specific impact
may occur during injection molding, if sub-standard condi- conditions.
tions are used) are very important variables. Flaws in this 6.4 The apparatus used in Test Method G may not have
surface will also affect results. sufftcient energy available to cause failure of some specimens
6.3 Impact properties of plastic materials can be very under the conditions of this procedure.
ASTM D3029 94 m 0759530 055b738 507 m
#tY D 3029
38-t
(L 50 i 0.03/n.)
c3EfVVETRY S-
B
.
/27.0 * 2.5mm.
(s;oo sworn.) STAT/ONAR Y
/-
t3EOM&7RY c CLAMP
/vOSE rnD/US 7 1 “1 /
7.94 -fLl05vnm /
(U. 312 ;C O.UU 2 I n.) R
FIGURE 3A
A 27.2 1.07
B 15 0.59
C 12.2 0.48
D 6.4 0.25
E 25.4 1
F 12.7 0.5
6.35 f 0.05 0.250 + 0.002
(nose yadius)
r (radius) 0.8 0.03
S (diameter)A 6.4 0.25
8 25+ 10 25~1’
FIG. 3 Tup Geometries for Test Method F Geometries A(3A), 6(3B), and C(X)
4
ASTM D3029 94 - 0759530 0556739 443 m
(I@ D 3029
FB, the inside diameter should be 38.1 f 0.80 mm (1.50 f 8.1.1 Cushioning and shielding devices shall be provided
0.03 in.). For Geometry FC, the inside diameter should be to protect personnel and to avoid damage to the impinging
127.0 * 2.5 mm (5.00 + 0.10 in.). See Table 1. The inside surface of the tup. A tube or cage can contain the tup if it
edge of the upper or supporting surface of the lower clamp rebounds after striking a specimen.
should be rounded slightly; a radius of 0.8 mm (0.03 in.) has 8.1.2 When heavy weights are used, it is hazardous for an
been found to be satisfactory. operator to attempt to catch a rebounding tup. Fig. 2 of Test
7.1.1.1 Contoured specimens shall be firmly held in a jig Method D 2444 shows an effective mechanical “rebound
so that the point of impact will be the same for each catcher” employed in conjunction with a drop tube.
specimen.
7.1.2 Tup Support, capable of supporting a 13.5-kg (30~lb) 9. Sampling
weight, with a release mechanism and a centering device to 9.1 Unless otherwise agreed upon between the manufac-
ensure uniform, reproducible drops. turer and the producer, the material shall be sampled in
NATE 2-Reproducible drops may be assured through the use of a accordance with Sections 9 through 14 of Practice D 1898.
tube or cage within which the tup fails. In this event, care should be
exercised so that any friction that develops will not reduce the velocity of 10. Test Specimens
the tup appreciably. 10.1 Fiat test specimens shall be large enough so that they
7.1.3 Positioning Device-Means shall be provided for can be clamped firmly if clamping is desirable,
positioning the tup so that the distance from the impinging 10.2 The thickness of any specimen in a sample shall not
surface of the tup head to the test specimen is as specified. differ by more than 5 % from the average specimen thickness
7.2 Tup: of that sample. However, if variations greater than 5 % are
7.2.1 The tup used in Geometry FA shall have a 15.86 + unavoidable in a sample that is obtained from parts, the
0. IO-mm (0.625 + 0.004-in.) diameter hemispherical head of sample may be tested, but the data shall not be used for
tool steel hardened to 54 HRC or harder. A steel shafi about referee purposes. Machining specimens to reduce thickness
13 mm (0.5 in.) in diameter shall be attached to the center of variation is not permissible.
the flat surface of the head with its longitudinal axis at 90“ to 10.3 When the approximate mean failure weight for a
that surface. The length of the shaft shall be great enough to given sample is known, 20 specimens will usually yield
accommodate the maximum number of weights required. sufficiently precise results. If the approximate mean failure
See Fig. 3A and Table 1. weight is unknown, six or more additional specimens should
7.2.2 The tup used in Geometry FB shall be made of tool be used to determine the appropriate starting point of the
steel hardened to 54 HRC or harder. The head shall have a test.
diameter of 12.7 + 0.1 mm (0.500 + 0.003 in.) with a conical 10.4 The specimen shall be carefully examined visually to
(50” included angle) configuration such that the conical ensure that samples are free of cracks or other obvious
surface is tangent to the hemispherical nose. A 6.4-mm imperfections or damages, unless these imperfections consti-
(0.25-in.) diameter shaft is satisfactory. See Fig. 3B and Table tute variables under study. Samples known to be defective
1. should not be tested for specification purposes. Production
7.2.3 The tup used for Geometry FC shall be made of tool parts, however, should be tested in the as-received condition
steel hardened to 54 HRC or harder, The hemispherical head to determine conformance to specified standards.
shall have a diameter of 33.1 + 0.4 mm (1.5 & 0.015 in.). A 10.5 Select a suitable method for making the specimen
steel shaft about 13 mm (0.5 in.) in diameter shall be that will not affect the impact resistance of the material.
attached to the center of the flat surface of the head with its NOTE ~--AS few as ten specimensoften yield sufficientlyreliable
longitudinal axis at 90” to that surface. The length of the estimates of the mean failure weight. However, in such cases the
shaft shall be great enough to accommodate the maximum estimated standard deviation will be relatively large (1).
number of weights required.
7.2.4 The tup head shall be free of nicks, scratches, or 11. Conditioning
other surface irregularities. 1 I. 1 Unless otherwise specified, condition the test speci-
7.3 Weights-Cylindrical steel weights are required that mens at 23 f 2°C (73.4 rf: 3.6”F) and 50 + 5 % relative
have a center hole into which the tup shaft will fit. A variety humidity for not less than 40 h prior to test, in accordance
of weights are needed if different materials or thicknesses are with Procedure A of Practice D 6 I8 and Specification E 17 1,
to be tested. For a material of quite low impact resistance, for those tests where conditioning is required. In cases of
the tup weight may need to be adjusted by increments of 10 disagreement, the tolerances shall be -el”C (k1.8’F) and
g or less. Materials of high impact resistance may require a2 % relative humidity.
increments of I kg or more. Il. I, 1 Note that for some hygroscopic materials, such as
7.4 Micrometer, for measurement of specimen thickness. nylons, the material specifications (for example, Specifica-
It should be accurate to 1 % of the average thickness of the tion D 4066) call for testing “dry as-molded specimens.”
specimens used. See Test Methods D 374 for descriptions of Such requirements take precedence over the above routine
suitable micrometers. preconditioning to 50 % relative humidity and require
7.5 The weight of the tup head and shaft assembly and the sealing the specimens in water vapor-impermeable con-
additional weights required must be accurate to k-1 %. tainers as soon as molded and not removing them until ready
for testing.
8. Hazards I 1.2 Conduct tests in the standard laboratory atmosphere
8.1 Safety Precautions: of 23 f 2°C (73.4 & 0.6”F) and at 50 +. 5 % relative
5
ASTM D3029 94 - 0759530 0556740 Lb5 m
6
ASTM D3029 94 - 0759530 0556743 OTL m
sample mean failure height or weight as follows: TABLE 2 Precision, Test Method FB
ss = GsJfi Values Expressed as
Material Mean, J Percent of the Mean
g = &JE V-6 rc
Polymethyl Methauylate (PMMA) 0.35 12.6 35.7
where: Styrene-Butadiene (SBp 9.26 10.7 52.9
9i = estimated standard deviation of the mean height, mm AcrVlonitrilbButadiene-Styrane(ABSjA 11.0 14.9 42.2
(or in.), A Data generated in three laboratories.
sii = estimated standard deviation of the mean weight, kg s V, = Within-laboratory coefficiint of variation of the mean.
(or lb), and cr=2.93V,.
G = factor that is a function of s/d (see Appendix X2). TABLE 3 Precision, Test Method FC
A sample computation of s, may be found in Appendix X 1.
Values Exoressed es
NOTE 6-For values of G at other levels of s/d, see Fig. 22 in Ref (5). Material Mean, J Percent oi the Mean
Energy-Calculate the estimated standard deviation of the Polymethyl Methacrylate (PMMA) 1.33 4.13 11.7
StvretwButadiene fSBb 40.3 1 a.3 51.8
mean-failure energy as follows:
A V, = within-laboratory coefficient of variation of the mean.
s,, = s)f wf: BY = 2.83 v,.
or
S,, = s* hA as applicable case Procedure). Each laboratory obtained one test result for
where: a material.
s MFE = estimated standard deviation of the mean failure 15.1.1 Polymethylmethacrylate (PMMA) - Specimens
energy. were cut from samples of 3.18-mm (0.125-in.) thickness
extruded sheet.
14. Report 151.2 Styrene-Butadiene (SB)-Specimens were cut from
14.1 Report the following information: samples of 2.54-mm (0. 100~in.) thickness extruded sheet.
14.1.1 Complete identification of the sample tested, in- 15.1.3 Acrylonitrile-Butadiene-Styrene (ABS)-Specimens
cluding type of material, source, manufacturer’s code, form, were cut from samples of 2.64-mm (0.104-in.) thickness
principal dimensions, and previous history. extruded sheet.
14,1.2 Method of preparation of specimens. NOTE 7--Caution: The followingexplanations of I and R (15.2
14.1.3 Means of clamping, if any. through 15.2.3)are only intended to present a meaningful way of
14.1.4 Statement of geometry (FA, FEl, FC) and proce- considering the approximate precision of this test method. The data in
Tables 2 and 3 should not be rigorouslyapplied to acceptance or
dure used-constant weight or constant height. rejection of material, as those data are specific to the round robin and
14.1.5 Thickness of specimens tested (average and range). may not be representative of other lots, conditions, materials, or
14.1.6 Number of tests specimens employed to determine laboratories. Users of this test method should apply the principles
the mean failure height or weight. outlined in Practice E 691 to generate data specific to their laboratory
14.1.7 Mean failure energy. and materials, or between specific laboratories. The principles of 15.2
14.1.8 Types of failure, for example: (a) crack or cracks through 15.2.3 would then be valid for such data.
on one surface only (the plaque could still hold water), (b) 15.2 Concept of r and R-If V,., and VR have been
cracks that penetrate the entire thickness (water would calculated from a large enough body of data, and for test
probably penetrate through the plaque), (c) brittle shatter results that were means from testing multiple individual
(the plaque is in several pieces after impact), or (d) ductile specimens. (Bruceton Staircase Procedure).
failure (the plaque is penetrated by a blunt tear). Report 15.2.1 Repeatability, r-In comparing two test results for
other observed deformation due to impact, whether the the same material, obtained by the same operator using the
specimens fail or not. same equipment on the same day, the two test results should
14.1.9 Date of test and operator name. be judged not equivalent if they differ by more than the r
14.1.10 Test temperature. value for that material.
14.1.11 In no case shall results obtained with arbitrary 15.2.2 Reproducibility, R--In comparing two test results
geometries differing from those contained in these test for the same material, obtained by different operators using
methods be reported as values obtained by Test Methods different equipment in different laboratories, reproducibility
D 3029. statistics were not calculated because data from only four
and three laboratories do not justify making these calcula-
15. Precision and Bias tions.
15.2.3 Any judgment in accordance with 15.2.1 would
15.1 Tables 2 and 3 are based on a round robin”
conducted in 1972 involving three materials tested by six have an approximate 95 % (0.95) probability of being
correct.
laboratories. Data from only four laboratories were used in
15.3 Bias-There are no recognized standards by which
calculating the values in these tables. Each test result was the
mean of multiple individual determinations (Bruceton Stair- to estimate bias of this test method.
15.4 Efforts to form a task group to address between-
laboratory reproducibility of these test methods have been
11Supporting data are available from ASTM Headquarters. Request RR: unsuccessful. Persons interested in participating in such a
D20 - 1030. task group should contact ASTM Headquarters.
7
ASTM D3029 94 - 0759530 055b-742 T38 D
($4 D 3029
LIFT HANDLE
8
ASTM D3029 9L,m 0759510 055b743 974 m
f## D 3029
I
127 mm I
7 (5 in.)
I
L
1.59 llpn
R
t.0625 in. R)
16.20 ) 0.25 mm
(3.00 * -01 in.)
I- I
50.8 f ,076 mm
(2.000 f .003 in.)
I I i
4
19 mm.
C.75 in.) 1 i"l
I
I
i I’
’ I %4L,E - hALf S1Z-E
MAT’L - ALWIl~tir\n, 2024
/
DRILL-J-
TAP T-35 I
6.35 mm - 20 NC x 15.67 mm Deep
(0.25 in. - 20 NC x 0.625 in. Deep)
(Two H&s)
16. I .3 With Geometry GC, the standard removable spec- obvious imperfections, unless the imperfections constitute a
imen-support plate, with a hole 16.26 + 0.025 mm (0.640 +- variable under study.
0.001 in.) in diameter, is mounted in the specimen support- 18.2 Same as in 10.2.
anvil, See Fig. 6. 18.3 Same as in 10.3.
16.2 Micrometer-See 7.4. 18.4 Same as in 10.4.
18.5 Same as in 10.5.
17. Sampling 19. Conditioning
17.1 Same as in 9.1. 19.1 Same as in 11.1
19.1.1 Same as in 11.1.1.
18. Test Specimens 19.2 Same as in 11.2.
18.1 The diameter or width of flat test specimens shall be
at least 25 mm (1 .OO in.) greater than the diameter of the 20. Procedure
hole in the support plate. The specimens shall be free of 20.1 Same as in 12.1.
9
ASTM D3029 94 W 0759530 055b744 800 m
‘@ D 3029
31.75 f .025 mm
(1.25 f 0.001 in.)
15.86 f .05 mm
(0.625 f .002 in.)
20.2 Same as in 12.2. 2 1.3 Esrimared S:andard Deviation of the Mean Failure
20.3 Same as in 12.3. Energy-Same as in 13.6.
20.4 Same as in 12.4.
20.5 Same as in 12.5. 22. Report
20.6 Position the specimen. The same surface or area, or 22.1 Same as in 14.1.
both, of the test specimen should be the target each time (see
6.2). If clamping is employed, the clamping force should be 23. Precision and Bias
suffkient to prevent motion of the specimen. 23.1 Tables 4, 5, and 6 are based on a round robinI
NOTE 7-Normally the specimen is not clamped because the test conducted in 1977 involving four materials tested by four
apparatus does not have provision for clamping. However, the apparatus laboratories. Data from only three laboratories were used in
can bc modified to permit clamping which should improve the calculating the values in these tables. Each test result was the
precisionof the measurement (see 4.9). mean of multiple individual determinations (Bruceton Stair-
case Procedure). Each laboratory obtained two test results for
20.7 Place the test specimen on the tester anvil, after
a material.
raising the weight and impactor foot. Be sure the specimen is
flat against the specimen-support plate before the impactor NOTE &Caution: The following explanations of r and R (23.2
foot is brought in contact with the top surface of the through 23.2.3) are only intended to present a meaningful way of
considering the approximate precision of this test method. The data in
specimen. (Figure 3 shows the position of the test specimen.) Tables 4 and 6 should not be rigorously applied to acceptance or
Raise the weight in the tube to the desired impact value, as rejection of material, as those data are specific to the round robin and
shown on the appropriate scale, and release it so that the may not be representativeof other lots, conditions, materials, or
weight drops on the impactor. laboratories. Users of this test method should apply the principles
20.8 Same as in 12.10. outlined in Practice E 691 to generate data specific to their laboratory
20.9 Same as in 12.11, using the constant-weight tech- and materials, or between specific laboratories. The principles of 23.2
through 23.2.3 would then be valid for such data.
nique.
20.10 Same as in 12.12. 23.1.1 Glass-Reinforced Nylon (33 % Glass)- 10 1 by 10 1
20.11 Same as in 12.13. by 3.2 mm (4 by 4 by ‘/8 in.), cut from injection-molded
20.12 Same as in 12.14. plaques.
23.1.2 Acetal (Homopolymer)-101 by 101 by 3.2 mm (4
21. Calculation
2 1.1 Mean Failure Height-Same as in 13.2. “Supporting data are available from ASTM Headquarters. Request RR:
2 1.2 Mean Failure Energy-Same as in 13.3. D20 - 1060.
10
ASTM D3029 94 - 0759530 055b745 747 -
v,* P VrA P
33 % glass-reinforced nylon (PA) 0.75 4.66 13.2 33 % glass-reinforced nylon (PA) I .a2 1.92 5.44
Acetal (POM) 2.12 6.90 19.5 Acetal (POM) 4.56 7.02 19.9
Impact polystyrene 15.1 2.20 6.23 Impact polystyrene 14.8 18.6 52.7
A V, = within-laboratory coefficient of vanatron of the mean. A V, = withrn-laboratory coefficient of variation of the mean.
8 r = 2.63 Vr. 8 I = 2.83 v,.
TABLE 5 Precision, Test Method GB same equipment on the same day, the two test results should
Values Expressed as be judged not equivalent if they differ by more than the r
Percent of the Mean
Material Mean, J value for that material.
vr* rs 23.2.2 Reproducibility, R-In comparing two test results
33 % glass-reinforced nylon (PA) 0.99 3.18 6.99 for the same material, obtained by different operators using
Acetal (POM) 2.57 11.6 32.8 different equipment in different laboratories, reproducibility
Impact polystyrene 10.3 12.3 34.7
Acryfonitrfle-butadiene-styrene (ABS) 26.9 6.56 18.6 statistics were not calculated because data from only three
laboratories do not justify making these calculations.
A V, = within-laboratory coefficient of variation of the mean.
8 f = 2.83 v,
23.2.3 Any judgement in accordance with 23.2.1 would
have an approximate 95 5%(0.95) probability of being correct.
23.3 Bias-There are no recognized standards by which
by 4 by r/s in.), cut from injection-molded plaques.
to estimate bias of this test method.
23.1.3 Impact Polystyrene-101 by 101 by 3.2 mm (4 by
23.4 Efforts to form a task group to address between-
4 by ‘/8 in.), cut from extruded sheet. laboratory reproducibility of these methods have been un-
23.1.4 ABS-IO 1 mm diameter by 3.2 mm (4 in. diam- successful. Persons interested in participating in such a task
eter by r/s in.), injection-molded disks. group should contact ASTM Headquarters.
23.2 Concept of I and R-If V, and VR have been
calculated from a large enough body of data, and for test
results that were means from testing multiple individual 24. Keywords
specimens (Bruceton Staircase Procedure). 24.1 dart impact; falling weight impact; gardner impact;
23.2.1 Repeatability, r-In comparing two test results for impact; impact resistance; mean failure energy; mean failure
the same material, obtained by the same operator using the height; mean failure weight; rigid plastic; tup
REFERENCES
(1) Brownlee, K. A., Hodgest, J. L., Jr., and Rosenblatt, Murray, “The Methods for Plastics Parts Used in Appliances, Society of the
Upand-Down Method with Small Samples,” American Statistical Plastics Industry, New York, NY, January 1965.
Association Journal, Vol 48, 1953, pp. 262-277. (4) “Test Method B-Gardner Impact,” ibid.
(2) Hagan, R. S., Schmitz, J. V., and Davis, D. A., “Impact Testing of (5) Weaver, 0. R., “Using Attributes to Measure a Continuous
High Impact Thermoplastic Sheet,” Technical Papers, 17th Annual Variable in Impact Testing Plastic Bottles,” Matertals Research
Technical Conference of SPE, SPPPB, Vol VII, January 196 I. and Standards, Vol 6, No. 6, June 1966, pp. 285-29 1.
(3) “Test Method A-Falling Dart Impact, Proposed Method of Test (6) Natrella, M. G., “Experimental Statistics,” National Bureau of
for Impact Resistance of Fabricated Plastics Parts,” Proposed Test Standards Handbook 91, October 1966, pp. lo-22 and 10-23.
11
ASTM D3029 94 - 0759530 0556746 h83 W
APPENDIXES
(Nonmandatory Information)
8.00 0 X X X X 4 I I 4 4 4
7.00 X 0 0 X 0 0 X X 0 4 5 0 4 0 0
6.00 0 0 0 0 0 0 5
Totals 9
(4)
w, = 7.ao;N=Nx=9;d= 1.00
w = w, + IA/N-0.5)
= 7.00 + 1.00(6/9 - 0.5)
= 7.17 kg
s = 1.620 d[((NB - A*)/92) + 0.0291
= ~,~O,,l.W, [((9.8 - a2)/9*) + 0.0291
X2. VALUES OF G FOR OBTAINING THE ESTIMATED STANDARD DEVIATION OF THE MEAN
s/d 0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09
The American Society for Testing and Materials takes no position respecting the validity of any patent fights asserted in connection
with any item mentioned in this standard. Users of this standard are express/y advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entire/y their own responsibifity.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feet that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, 19 16 Race St., Philadelphia, PA 19 fO3.
12