(12V9.

0Ah)
RT 1290H (37.6w/cell)
RT1290H is high rate series with 8 years floating design life,
especially designed for high rate load discharge applications .
By using strong grid and specific paste plate to insure high
performance during big current discharge requirement when
electricity is off ., High Rate series offering extra-durable stable
performance under high rate discharge.
Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity 37.6W@15min-rate to 1.67V per cell @25 oC
Weight Approx. 2.63 Kg
Max. Discharge Current 90 A (5 sec)
Internal Resistance Approx. 18 mΩ
o o
Operating Temperature Range Discharge: -20 C ~60 C
Charge: 0 oC~50 oC
Storage: -20 oC~60 oC

Normal Operating Temperature Range 25 oC±5 oC


Float charging Voltage 13.7 to 13.9 VDC/unit Average at 25 oC
Recommended Maximum Charging 2.7 A
Current Limit
Equalization and Cycle Service 14.6 to 14.8 VDC/unit Average at 25 oC
Self Discharge RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored
o
for more than 6 months at 25 C. Self-discharge ratio less than 3%
per month at 25 oC. Please charge batteries before using.

Terminal Faston tab 250(F1/F2)


Constainer Material A.B.S. (UL94-HB), Flammability resistance of UL94-V2
can be available upon request.

Dimensions
Unit: mm Dimension: 151(L)×65(W)×93.5(H)

Constant Current Discharge Characteristics : A(25 oC)

F.V/Time 5MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN


9 .6 0 V 4 1 .2 7 3 0 .5 1 2 6 .0 6 2 0 .7 9 1 5 .5 1 1 1 .4 3 6 .4 3 8 5 .0 8 3
1 0 .0 V 4 0 .0 0 2 9 .7 8 2 5 .3 3 2 0 .3 1 1 5 .0 4 1 1 .1 8 6 .3 7 2 5 .0 2 3
1 0 .2 V 3 8 .6 9 2 7 .8 9 2 3 .8 2 1 9 .5 1 1 4 .7 2 1 0 .9 2 6 .1 7 3 4 .8 9 1
1 0 .5 V 3 7 .3 6 2 5 .8 1 2 1 .7 6 1 8 .5 2 1 4 .1 1 1 0 .5 5 5 .9 4 7 4 .8 3 6
1 0 .8 V 3 4 .4 9 2 3 .9 6 1 9 .4 8 1 7 .6 9 1 3 .7 2 9 .2 0 5 .7 2 1 4 .6 8 2
1 1 .1 V 3 1 .6 2 2 2 .1 1 1 7 .2 1 1 6 .8 5 1 3 .3 3 8 .4 0 5 .4 9 5 4 .5 2 7

Constant Power Discharge Characteristics : W(25 oC)


F.V/Time 5MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
9 .6 0 V 4 4 6 .5 3 3 3 .5 2 8 6 .6 2 2 9 .6 1 7 1 .5 1 2 6 .6 7 1 .6 5 5 6 .6 6
1 0 .0 V 4 3 7 .2 3 2 6 .3 2 7 8 .8 2 2 5 .6 1 6 7 .7 1 2 4 .6 7 1 .0 2 5 6 .0 5
1 0 .2 V 4 2 7 .0 3 1 0 .9 2 6 6 .2 2 1 8 .9 1 6 5 .9 1 2 3 .6 7 0 .2 6 5 5 .8 8
1 0 .5 V 4 1 6 .4 2 9 1 .5 2 4 7 .6 2 1 2 .1 1 6 1 .8 1 2 1 .3 6 9 .0 2 5 5 .6 4
1 0 .8 V 3 9 2 .5 2 7 3 .5 2 4 2 .8 2 0 3 .2 1 5 7 .0 1 0 8 .2 6 7 .4 3 5 5 .1 5
1 1 .1 V 3 6 8 .6 2 5 5 .4 2 3 8 .0 1 9 4 .3 1 5 2 .1 1 0 0 .4 6 5 .8 5 5 4 .6 7
All mentioned values are average values.
RT1290H 12V9.0Ah
Storage characteristic

10 100
Supplementary charge required
8
0℃ (Carry out supplementary charge
before use if 100% capacity is
6 80 requires)

Capacity (%)
10℃
Life Expectancy (years)

Supplementary charge required


4 60 before use.
This supplementary charge will help
to recover the capacity and should
20℃ be made as early as possible.
40 40℃ 30℃
2 Supplementary charge may often
fail to recover the capacity.
The battery should never be left
20 standing till this state is reached

0
Supplementary charge and storage
0 10 20 30 40 50 2 4 6 8 10 12 14 16 18 20 22 24 guidelines

Battery Temperature (℃) Storage Time (months)

Charge characteristic Curve for standby use Discharge characteristic Curve


15 7.5 5.0 120 0.24
Chcrge Volume 13 6.5 4.3

14 7.0 4.7 100 0.20


Chcrge Voltage
Term inal Voltage (V)
12 6.0 4.0
C harge Voltage ( V )

C harge Volum e (% )

C harge C urrent (C A)

13 6.5 4.3 80 0.16


① Discharge
100%(0.05CA×20h) 11 5.5 3.7
12 6.0 4.0 50%(0.05CA×10h) 60 0.12 0.05C
② Charge 0.16C 0.093C
Chcrge Voltage2.275V/C 0.35C
Charge Current0.1CA 10 5.0 3.3 0.62C
11 5.5 3.7 40 0.08
③ Temperature 25℃
3C 1C

10 5.0 3.3 20 0.04 9 4.5 3.0


Charge Current
0.6 1.2 3 6 12 30 1 2 5 10 20 24
9 4.5 3.0 0 0
0 2 4 6 8 10 12 14 16 18 20 24 28 min Hr

Charge Time(h) Discharge Time

Capacity Factors With Different Temperature


Battery Type -20℃ -10℃ 0℃ 5℃ 10℃ 20℃ 25℃ 30℃ 40℃ 45℃
GEL 6V&12V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105%
Battery 2V 60% 75% 85% 88% 92% 99% 100% 103% 105% 106%
AGM 6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109%
Battery 2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110%

Discharge Current VS. Discharge Voltage Maintenance & Cautions

Final Discharge Float Service :


1.75V 1.70V 1.60V
Voltage V/cell
※  Every month, recommend inspection every battery voltage.
Discharge (A)≥1.0C
(A)≤0.2C 0.2C<(A)<1.0C
Current (A) ※  Every three months, recommend equalization charge for one time.

Equalization charge method:


Charge the batteries at least once every six months,
if they are stored at 25 oC. Discharge: 100% rate capacity discharge.

Charging Method: Charge: Max. current 0.3CA, constant voltage 2.4-2.45V/Cell charge 24h.

Constant Voltage -0.2Cx2h +2.4~2.5V/Cellx24h,Max. Current 0.3CA ※  Effect of temperature on float charge voltage: -3mV/℃/Cell.

Constant Current -0.2Cx2h+0.1CAx12h ※  Length of service life will be directly affected by the number of discharge
.
Fast -0.2Cx2h+0.3CAx4.0h cycles, depth of discharge, ambient temperature and charging voltage.

SHENZHEN RITAR POWER CO.,LTD. Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China
URL:www.ritarpower.com Tel:+86-755-33981668 Fax:86-755-8347-5180 2010 - Version 1