Sei sulla pagina 1di 3

PROJECT :

ARCHITECT :
SHEET REF No.:
z
FOOTING NO.: F1
x x
2
Net Soil Bearing Capacity = 110 kN/m
z
Grade of concrete = M 25 3.1 m
Depth Of Footing below Ground Level = 1.5 m
Cover Taken 50 mm
Steel Grade Fe 500

Column Width = Cz = 0.6 m 3.1


Column Length = Cx = 0.45 m

Pedestal Projection 0 mm

Axial Load on column = 481 KN For load combination 106 DL+LL+EQZ+TL + Settlement Load

Axial Load on column + 69% extra = 812.89 kN


(22% as a selfweight + 47% of soil weight)

Moment @ X Direction = 310 kN-m

Moment @ Z Direction = -254 kN-m

2
Area Required = 7.39 m 600mm
300
Footing Size
3100 mm
Lz = 3.1 m
Lx = 3.1 m Footing size = Lx× Lz
2
Area Provided = 9.61 m O.K.

Bearing Pressure For Design


Axial load is taken 22% extra for the self-weight + 47% of soil weight
2 2 2
Pmax 95.9 kN/m Safe Pmax = [(Axial load)/(Lx×Lz)] + [(6Mx)/Lz×Lx )] + [(6Mz)/Lx×Lz )
2 2 2
Pmin 73.3 kN/m Safe Pmin = [(Axial load)/(Lx×Lz)] - [(6Mx)/Lz×Lx )] -[(6Mz)/Lx×Lz )

Design

2
Moment in X Direc @ face of the Colm = 112.34 kN-m Mx at face of the column = [[Lz – ( Cz + 2×.001 × pedestal projection)] × 0.5] × 1.5 × 0.5 x Pmaxdesign

2
Moment in Z Direc @ face of the Colm = 126.23 kN-m Mz at face of the column = [[Lx – ( Cx + 2x.001 x pedestal projection)] x 0.5] × 1.5 × 0.5 × Pmaxdesign
Assume D1 = 600 mm
D2 = 300 mm
d eff. = 544 mm deff = D – clear cover – (0.5 × dia of bar)

ku(x) 0.379621129 Ku(x) =


ku(z) 0.426542301

2
Ast(in X Direction ) = 7.20 cm /m Ku(z) =
2
Ast(in Z Direction ) = 7.20 cm /m

provide 12 @ 150 mm c/c in Z Direction Ast in x-direction = ,


Ast = 7.5 cm2 SAFE
provide 12 @ 150 mm c/c in X Direction whichever value is greater
Ast = 7.5 cm2 should be taken
SAFE
Check For One Way Shear

Critical Section at the distance of 'd' from the face of the column
Ast in x provided = ˃ Ast required OK
Shear at the Critical Section Vu = 112.31 kN d

tc = Vu /bd = 0.24 Check for one way shear:


477 Critical section at the distance ‘d’ from the face of the column
pt = 0.14 Shear at critical section ,Vu
Ʈc = Vu/bd
tc permissible = 0.30 N/mm2 SAFE 781 Ʈc permissible ˃ Ʈc OK
1325

Check For Punching Shear


Check for punching shear:
tv = V/bod Ʈv = Vu /bod
bo = 4276 mm 994 Ʈc permissible = Ks × Ʈc
d= 544 mm Ʈc permissible = (0.5+ βc) × 0.25 × √fck ˃ Ʈv OK
tv = 0.35 N/mm2 1144

tc permissible = ks tc
tc permissible = (0.5+ bc)*0.25 fck
= 1.25 N/mm2
SAFE

3100 mm

12 @ 150 c/c
c/c

3100 mm
##
12 @

600
300

12 @ 150 c/c c/c


12 @ 150 c/c