Sei sulla pagina 1di 1

Design of column as per IS-456 Column P1 A-6

Percentage of reinforcement 0.80384 %


Material properties p/fcu 0.0229669
Fcu 35 N/mm2
Fy 500 N/mm2 Pu/(fcu*b*d) 0.016778
w(con) 25 KN/m3
Esteel 200000 N/mm2 Mu/(fcu*b*d^2) ( from table) 0.050298
Member Properties
Moment carrying capacity about shorter dimension 970.4281 KNm
Clear height of column 2.35 m Moment carrying capacity about Larger dimension 462.1086 KNm
Smaller dimension of col 0.5 m
Larger Dimension of col 1.05 m Mx/Mux 0.299167
End Condition 1 My/Muy 0.021683
b 1
Effective height 2.35 m Design Load 9851.31 KN
Le/Ll 4.700 Short column P/Puz 0.031295
Coefficient of effective cover 0.05
Effective Cover to reinforcement 0.025 m Alpha 1

Loads Check for biaxial bending 0.32085 Design is ok

Factored load = 308.3 KN

Column Interaction Chart

Reduction factor due to selenderness


0.5
Cr 1 0.45
Min. Eccentricities 0.4
0.35
Min. Eccentricity along largest dimension 0.02 m Pu/Fcubd
0.3
Min. Eccentricity along least dimension 0.02 m 0.25
Design Curve
Design Pu/fcubd
0.2
0.15
Moments 0.1
Min. Eccentric Moment about least dimension 6.166 KNm 0.05
Min. Eccentric Moment about largeset dimension 6.166 KNm 0
0 0.02 0.04 0.06 0.08 0.1 0.12
Actual Moment about least dimension 290.32 KNm
Mu/Fcubd2
Actual Moment about bigger dimension 10.02 KNm