Technical features
Types F4000 F4024
Protection rating IP54 IP54
Power supply (V) 230 A.C. 50/60 Hz 230 A.C. 50/60 Hz
Motor power supply (V) 230 A.C. 50/60 Hz 24 D.C.
Current draw (A) 1,9 15 max
Max power (W) 235 180
Reduction ratio (i) 1/150 1/150
Duty cycle (%) 30 intensive use
Max torque (Nm) 340 470
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55
Rev. per minute (rpm) 9 9
Gate operators tested
230V A.C. 24V D.C.
in compliance with
European
Limits to use Standards on the
subject of impact
Type F4000 - F4024
force.
Application Swing doors - Folding doors
Max leaf width (m) 2 1,5 (articulated)
Max leaf weight (Kg) 300 200
Dimensions
555
F4000
151,5
350
161
194,5
F4004 - F4024
industrial and residential
folding doors
© Came DEP5733 06/2007
The data and information shown in this catalogue are subject to change without the obligation to give prior notice by Came cancelli automatici S.p.A.
F4000 The 230V electronics
The new technology employed in the F4000 series provides specific command and
safety functions, which are standard in the BASIC version. However, other control
panels are available, which also deliver state-of-the-art performance, in terms of
both operational as well as safety performance. Here are some examples:
The powerful, The F4000 series gearmotors are the ideal solution when needing automation
yet compact for slide guide folding door. Attached to the lintel or door leaf, depending > System’s safety devices test
operator on the space available, they provide a safe, linear motion on medium Prior to any door operation, whether opening or closing.
and large doors. They are also well suited for swing doors used in > Pedestrian or partial opening
To enable the opening of just one of the leaves, or partial opening for pedestrian access.
residential premises.
> Complete hardware test from the transmitter
Including the possibility of immediately stopping the movement of the leaves.
Control panel
Switch
Sturdy inside and out.
F4000 and F4024 are designed to be
easily installed without compromising Electric cable Release lever and cord
the aesthetics. junction box
In the event a careful analysis of the automated gate’s risks were to require it, the use of sensitive safety infrared or contact edges
becomes indispensable.