Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > Industrial Relays and Timers > NEMA Heavy-Duty Industrial Relays > Bulletin 700-P, 700-PH, and 700-PK
Heavy-Duty Relay
Product Selection
AC-Operated Relays
4 — 700-P400Ä 700-P401Ä
6 — 700-P600Ä 700-P601Ä
8 — 700-P800Ä 700-P801Ä
10 — 700-P1000Ä 700-P1001Ä
12 — 700-P1200Ä 700-P1201Ä
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-P200Ä
becomes Cat. No. 700-P200A48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48 A1z B11ª — — B27 — B22 B2 — — B3 B41 B44 — B50 —
DC-Operated Relays
1 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
2 — 700DC-P200Ä 700DC-P201Ä
4 — 700DC-P400Ä 700DC-P401Ä
6 — 700DC-P600Ä 700DC-P601Ä
8 — 700DC-P800Ä 700DC-P801Ä
10 — 700DC-P1000Ä —
12 — 700DC-P1200Ä —
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-P200Ä
becomes Cat. No. 700DC-P200Z48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
¬ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
T Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O. contact closes
before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P161.
§ Location of contacts in 6-pole relays: 4-pole relay plus the two contacts indicated.
§ Location of contacts in 10-pole relays: 8-pole relay plus the two contacts indicated.
Ø For Type 4/4X Enclosure replace 1 with 4, for Type 7 & 9 Enclosure replace 1 with 7 (Example, 700-P401 becomes 700-P404).
AC-Operated Relays
4 — 700-PK401Ä
6 — 700-PK601Ä
8 — 700-PK801Ä
10 — 700-PK1001Ä
12 — 700-PK1201Ä
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-PK200Ä
2 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
becomes Cat. No.700-PK200A48 for 48V 60 Hz. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley
distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48 A1z B11ª — — B27 — B22 B2 — — B3 B41 B44 — B50 —
DC-Operated Relays
4 — 700DC-PK400Ä 700DC-PK401Ä
6 — 700DC-PK600Ä 700DC-PK601Ä
8 — 700DC-PK800Ä 700DC-PK801Ä
10 — 700DC-PK1000Ä —
12 — 700DC-PK1200Ä —
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PK200Ä
becomes Cat. No. 700DC-PK200Z12 for 12V DC. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley
distributor.
¬ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
T Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O. contact closes
before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P161.
§ Location of contacts in 6-pole relays: 4-pole relay plus the two contacts indicated.
§ Location of contacts in 10-pole relays: 8-pole relay plus two contacts indicated
Ø For Type 4/4X Enclosure replace 1 with 4, for Type 7 & 9 Enclosure replace 1 with 7 (Example, 700-PK401Ä becomes 700-PK404).
3 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
AC-Operated Relays
2 — 700-PH200Ä 700-PH201Ä
3 — 700-PH300Ä 700-PH301Ä
4 — 700-PH400Ä 700-PH401Ä
5 — 700-PH500Ä 700-PH501Ä
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PH100Ä
becomes Cat. No. 700-PH100A48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48 A1z B11ª — — B27 — B22 B2 — — B3 B41 B44 — B50 —
DC-Operated Relays
4 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
2 — 700DC-PH200Ä 700DC-PH201Ä
3 — 700DC-PH300Ä 700DC-PH301Ä
4 — 700DC-PH400Ä 700DC-PH401Ä
5 — 700DC-PH500Ä 700DC-PH501Ä
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-
PH200Ä becomes Cat. No. 700DC-PH200Z12. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley
distributor.
¬ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
‡ Location of contacts in 3-pole relays: 2-pole relay plus the contact indicated.
§ Location of contacts in 5-pole relays: 4-pole relay plus the contact indicated.
5 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
2 — 700-PT200Ä 700DC-PT200Ä
4 — 700-PT400Ä 700DC-PT400Ä
2 — 700-PKT200Ä 700DC-PKT200Ä
4 — 700-PKT400Ä 700DC-PKT400Ä
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PKT200Ä
becomes Cat. No. 700-PKT200A48 for 48V 60 Hz. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley
distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48 A1z B11ª — — B27 — B22 B2 — — B3 B41 B44 — B50 —
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-
PKT200Ä becomes Cat. No. 700DC-PKT200Z12 for 12V DC. For other coil voltages, consult your local Rockwell Automation sales office or Allen-
Bradley distributor.
¬ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
T Overlap contacts: N.O. contact closes before N.C. contact opens. To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing two pairs:
Use Cat. No. 700-PTZ2220. AC Ratings: NEMA A600, DC Ratings: P161.
§ Timer has 1 N.O. and 1 N.C. convertible cartridge in addition to the instantaneous cartridges on the relay. Timer is supplied as On-Delay. Convertible to Off-Delay in the
field.
Ø The timer has 1 N.O. and 1 N.C convertible master cartridge in addition to the instantaneous master cartridges on the relay. Timer is supplied as On-Delay. It is
convertible to Off-Delay in the field.
6 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
2 — 700-PL200Ä 700DC-PL200Ä
4 — 700-PL400Ä 700DC-PL400Ä
6 — 700-PL600Ä 700DC-PL500Ä
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PL200Ä
becomes Cat. No. 700-PL200A48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
Relays with latch attachments: if the latch attachment coil is to be a different voltage other than the relay coil, add a second coil code suffix.
Example: Cat. No. 700-PL400A1A24. Only one suffix is required if both coils are the same voltage.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48 A1z B11ª — — B27 — B22 B2 — — B3 B41 B44 — B50 —
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PL200Ä
becomes Cat. No. 700DC-PL200Z12. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
7 of 8 1/18/2011 9:11 AM
Industrial Control - Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay http://www.ab.com/en/epub/catalogs/12768/229240/229266/229661/30...
ATTENTION – An open or failed unlatch control circuit will fail to unlatch the relay. For this reason, a mechanical latch unit should not be used where protection is needed
against automatic restart after a power failure or where reliability to a control function is critical to safety.
¬ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
T Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing two pairs: Use Cat. No. 700-PTZ2220. N.O. contact closes
before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P161.
§ Location of contacts in 4-pole relays: 2-pole relay plus the 2 contacts indicated.
8 of 8 1/18/2011 9:11 AM