Sei sulla pagina 1di 3

Response:

1- Nature of installation ( antennas, equipment, callings)

Reply: The DIS (Digital Inbuilding System) is mainly composed of BBU, optical fiber, RHUB,

network cable or composite fiber cable and pRRU, Antenna.

2. Where to install in our building ( rooftop of Main Wing or Tower Wing ( we have 2 buildings on

site)

Reply: We usually need to install the equipment in a small space on one of the floors, not every

floor. Depends on the detail design drawing.

Equipment installation location requirements:

1. The installation of the equipment requires a wall area of 4 square meters to meet the

personnel working space.

2. It is convenient for providing power to equipment and meeting the requirements of

comprehensive wiring.

3. Fulfil basic waterproof requirements and well ventilation.

3- Area needed 

- In the future if things progress we will need the all Equipments capacity and weights.

Reply: Introduction to Huawei products

BBU 5900 specification

Specifications Details

Common-mode ability Support FDD-LTE/NB-IOT/eMTC/5G

Volume (2U) H 86 mm x W 442 mm x D 310 mm

Weight BBU5900≤18kg(full configuration )

Power dissipation(DC At 50°C,the maximum heat dissipation capacity of


Scene) BBU5900 is 2100W.
Power dissipation(AC
1250W (OPM200)
Scene)
Operating temperature -20℃~+55℃(Long term operation)
Relative humidity 5% RH~95% RH
Protection level IP20
RHUB specification
Specifications RHUB5961 RHUB5963

Volume (1U) H 43.6 mm x W 442 mm x D 310 mm

Weight ≤8kg

Input voltage 90 V AC to 290 V AC


Operating
-20℃~+55℃(Long term operation)
temperature

Transmission FE/GE electrical interface:8*25Gbps


interface FE/GE optical interface*2
Power <80 W(Full-load power
<60W
dissipation consumption)
8x99.9W:The power supply
Power supply 8x200W:The power supply
capacity of every CPRI_E is
capacity capacity of every CPRI_E is 200W
99.9W

pRRU specification

Specifications pRRU3902 pRRU5961

Frequency
1920-1980/2110 to 2170 3300-3600
band(MHz)

Volume(H*W*D) 200 mm x 200 mm x 50 mm

Weight ≤1.5kg ≤2kg

Power 2*250mW 4*250mW

Input voltage –38.4 V DC to –57 V DC


Operating
-20℃~+55℃(Long term operation)
temperature
Transmission
RJ45/Optical RJ45/Optical
interface
Power Typical :60/Maximum
<60W
dissipation(W) Average:65
-An Structural Plan from your Structural Engineer.

Reply: We need to obtain the floor plan of the building in order to make an structural plan.

-Architectural plan of the equipment and facilities installation on how it will affect the

aesthetically look of our buildings 

Reply: We usually need to obtain the floor plan of the building in order to make an structural

plan. Then we can evaluate whether it will affect the aesthetically look of the buildings based on

it.

- Electro Magnetic Field ( EMF) studies of the Antennae emitting microwaves and Radio
Frequencies. 
Reply: The equipment has passed the standard evaluation test of the reliability laboratory of

Huawei Technologies Co., Ltd. The laboratory has been accredited by the China National

Accreditation Service for Conformity Assessment (CNAS) and has been accredited by the

American Association for Laboratory Accreditation (A2LA).

The evaluation test is conducted under the most severe conditions. During the assessment

process, the equipment/site’s feeder cable loss, mismatch, leakage, antenna type and

surrounding environment were not considered. Finally, the safe distance between the

observation point (public) and the equipment antenna was obtained (that is, the minimum

distance between the public and the equipment antenna should be ensured distance). Because it

is the most stringent evaluation result, the public believes that electromagnetic radiation from

the equipment will not cause obvious health effects on the human body outside the safe

distance range from any direction of the equipment antenna.

Potrebbero piacerti anche