Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Charlie
2020.06.30
V2.0
• MS-100 introduction
1. Definition
⚫ MRI machines use a powerful magnetic field to produce internal images
of the human body. The magnetic fields are so powerful that hospitals
take great care to ensure no iron-containing metals come near the
machines while they are in use.
⚫ Ferromagnetic items CANNOT be brought into the MR environment: iron,
nickel, cobalt, BB’s, bullets
MR safe use
Can be used in MR environment without restrictions (no metal
parts
Available in MR environment
Use under restricted conditions, such as maximum magnetic
field strength
MR is not safe
Not suitable for use in MR environment
Potential problem 3 – Danger for patients and staffs caused by accelerated magnetic devices
内部资料,请勿外传
HP-80 MRI WorkStation
内部资料,请勿外传
Compatibility Level in MRI environment
MR UNSAFE
MR CONDITIONAL
Tube clamps
Door handle
Stock temporary
Trolley
Free combination
pumps
• Save on money
HP-30 PRO
HP-30 Neo
HP-80 MRI
Infusion
© Medcaptain 2020 All rights reserved. WorkStation
Flexibility
Continuous infusion
VS VS
Conditionally MR safe
PATENT
• Invention: 201810793418.0 a MRI compatible infusion
system based on Faraday cage real trial
• Stage utility model: 201821137215.8 a MRI compatible
infusion system based on Faraday cage has been
authorized
▪ Radiology
− in some instances, anaesthesiologists
need to stay in the radiation environment
all the time
▪ MRI examination
− continuous infusion needed
− extra bolus needed
▪ Isolation ward/rooms
− as seen during COVID-19 pandemic
− needed for protection of patient and/or
clinician
− infusion operation becomes a risk
The Big Question
If the user is not able to stay close to the pumps.
Can the infusion system be managed from a distance?
How can we
Bridge the Distance & Barriers ?
INFUSION MANAGEMENT
REMOTELY CONTROLLED
MS-100
Infusion Work Station
Bridging the Distance
MS-100
A Medcaptain Product
▪ Novel, first of its kind in the world!
Differences
▪ No HDMI for MS-100 SCU
▪ No RJ45 for MS-100 SCU, instead, it’s been replaced to a special data port.
MS-100 Clinical Application
Isolation Room
MRI examination
MS-100 Interface
▪ Medcapatain has made a huge technological leap with the Prof. dr. Michel Struys,
department head of the department of the University Medical Center Groningen, The
Netherlands. see also https://www.umcg.nl/EN/Research/InstitutesProgrammes/vapor-
2/teams/Paginas/Prof--Michel-Struys,-MD,-PhD,-FRCA-.aspx
▪ Remote operation of pumps that remain close to the patient in undesirable situations
bridges the distance between patient and operator.
▪ With ongoing COVID pandemic, this new technology allow nurses to operate infusion
pumps from outside the room:
− change of protective gear not required as often
− saves time & resources
− reduce infection risks
▪ Other difficult and high risk situations, such as procedures in proton bunkers, radiology, or
even crowded OR’s would greatly benefit from such this novel system
Questions
&
Answers
内部资料,请勿外传
THANK YOU