Sei sulla pagina 1di 1

CHB WALL

A. GENERAL :
REBAR
1. ALL STRUCTURAL PLANS ,SPECIFICATIONS, AND SHOP
DRAWINGS, SHALL MEET ALL REQUIREMENTS SET BY THE
10 MM Ø DOWELS @
NATIONAL BUILDING CODE, NATIONAL STRUCTURAL CODE T (thickness)

600MM O.C. W/ 10MM Ø


OF THE PHILS., AND THE LOCAL CODE OF THE CITY / HORIZONTAL DEF. BARS @
MUNICIPALITY / DISTRICT OF THE SITE. EVERY THIRD LAYER OF CHB
2. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY
TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED,
MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL
CONDITIONS. GRAVEL FILL
3. SHOP DRAWINGS WITH ERECTION AND PLACING 5" THICK CHB
DIAGRAMS OF ALL STRUCTURAL STEELS, MISC. IRON, 10 - 16 MM Ø REBARS 10 - 16 MM Ø REBARS COMPACTED BACKFILL
PRE-CAST CONCRETE, ETC., SHALL BE SUBMITTED FOR THE BOTHWAYS BOTHWAYS
ENGINEER / DESIGNER'S APPROVAL BEFORE FABRICATION.
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
PROVIDE ADEQUATE SHORING & BRACINGS OF THE
STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING
6 - 16 MM Ø MAIN CHB TO SLAB-ON-GRADE END DETAILS
CONSTRUCTION. VERTICAL REBARS CHB WALL
B. CONCRETE : NGL NGL
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM
WITH THE LATEST BUILDING CODE OF AMERICAN
CONCRETE INSTITUTE (ACI-318).
2. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE REBAR
STRENGTH AT THE END OF TWENTY EIGHT (28) DAYS (MAX.
PERIOD): T (thickness)

LOCATION 28 DAYS MIXING


STRENGTH PROPORTION 7 - 16 MM Ø REBARS 3-12 MM Ø CONTINOUS
ALL CONCRETE
MEMBERS
2,500 PSI CLASS B / 1 : 2 : 4
BOTHWAYS DEF. BARS W/ 10MM Ø
TIES @ 250MM SPACING
GRAVEL FILL
3. IN GENERAL THE LATEST EDITION OF ACI-315, MANUAL
OF STANDARD PRACTICE DETAILING REINFORCED
CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS COMPACTED BACKFILL
OTHEREWISE SHOWN OR NOTED.
C. REINFORCEMENT: CASE 1 CASE 2 CHB TO SLAB-ON-GRADES DETAILS WALL FOOTING
1. ALL REINFORCING BARS SHALL CONFORM TO ASTM
A615 GRADE 33 FOR DIAMETER 16 AND SMALLER BARS AND 3 DETAILS - WF
GRADE 40 FOR DIAMETER 20 AND LARGER BARS. SCALE: NTS
2 MASONRY DETAILS S 2
2. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS,
SHALL BE PROPERLY POSITIONED AND SECURED IN PLACE 1 FOOTING DETAILS - F1
SCALE: NTS
PRIOR TO PLACING OF CONCRETE.
3. ALL INTERSECTING BARS SHALL BE SECURED USING A S 2 SCALE: 1 : 50 MTS S 2
NO.16 TIE WIRE.
4. SPLICES IN BEAMS, SPLICE HALF OF THE BARS AT 1/4
OF THE SPAN OF THE BEAM FROM FACE OF SUPPORT, AND
SPLICE THE OTHER HALF AT 1/4 OF SPAN FROM THE
OPPOSITE SUPPORT. AT MIDSPAN AT SUPPORT AT MIDSPAN AT SUPPORT
5. SPLICES IN COLUMNS, SPLICE HALF OF THE BARS AT 1/2
OF THE COLUMN HEIGHT FROM THE BASE AND SPLICE THE L
OTHER HALF AT 1/2 OF THE COLUMN HEIGHT OF THE
L/4 L/4
SUCCEEDING FLOOR.
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND Ø12x1000 LONG DIAGONALS AT
SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE 1 MID-DEPTH OF WALL AT EACH CORNER
(TABLE OF LAP AND SPLICES AND ANCHORAGE LENGTH) COMPRESSION BAR
UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL TOP BAR: 2 - 16 MM Ø RSB TOP BAR: 2 - 16 MM Ø RSB TOP BAR: 3 - 16 MM Ø RSB TOP BAR: 5 - 16 MM Ø RSB
BOTTOM BAR: 2 - 16 MM Ø RSB BOTTOM BAR: 2 - 16 MM Ø RSB BOTTOM BAR: 5 - 16 MM Ø RSB BOTTOM BAR: 3 - 16 MM Ø RSB
BE STAGGERED WHENEVER POSSIBLE.
D. MASONRY: STIRRUPS 10 MM Ø @ 5-50MM, STIRRUPS 10 MM Ø @ 5-50MM, STIRRUPS 10 MM Ø @ 5-50MM, STIRRUPS 10 MM Ø @ 5-50MM,

SEE TABLE OF
ANCHORAGE

30 BAR DIA.
(TYPICAL)
1. ALL CONC. HOLLOW BLOCK (CHB) SHALL USE 2-100MM, 2-150MM & REST AT 2-100MM, 2-150MM & REST AT 2-100MM, 2-150MM & REST AT 2-100MM, 2-150MM & REST AT
TENSION BAR

COLUMN

COLUMN
200MM O.C. 200MM O.C. 200MM O.C. 200MM O.C.
NON-LOAD BEARING CHB UNLESS OTHERWISE SPECIFIED.
2. ALL PLASTER AND MORTAR MIXTURE SHALL USE CLASS FTB (FOOTING TIE BEAM) B1 (ROOF DECK BEAM)
B/1:3
WINDOW OPENING 10mm Ø CLOSED STIRRUPS SPACED @
3. PROVIDE LINTEL COLUMN FOR EVERY 3.0M DISTANCE.

4
3-50mm, 3-100mm, 3-150mm & REST
PROVIDE LINTEL BEAM FOR EVERY 3.0M HEIGHT.
E. FOUNDATION:
BEAM SCHEDULE L/5 AT 200mm O.C. L/5
SCALE: 1 : 40 MTS DOOR OPENING
1. THE ALLOWABLE FOUNDATION PRESSURE USED WAS
BASED ON AN ASSUMED VALUE OF 150 KN/SQM BASED ON
S 2
CHAPTER 7 TABLE NO.7-B OF THE NSCP. LENGTH OF SPLICE
40
2. THE LATERAL BEARING USED WAS BASED ON AN 1-16Ø EACH FACE 100 mm o.c.
ASSUMED VALUE OF 60 KN/SQM/M OF DEPTH BASED ON OF OPENING (TYPICAL) 1. CLEAR CONCRETE COVER = 40mm TOP BARS 75 75
CHAPTER 7 TABLE NO. 7-B OF THE NSCP. 2. LOCATE TOP BAR SPLICES AT MIDSPAN
LENGTH OF SPLICE = 40mm ADD'L.TOP BARS
3. THE LATERAL SLIDING USED WAS BASED ON AN ( AS REQUIRED )
3. LOCATE BOTTOM BAR SPLICES 2 X BEAM
ASSUMED VALUE OF 0.35 BASED ON CHAPTER 7 TABLE NO. HEIGHT AWAY FROM FACE OF COLUMN.
7-B OF THE NSCP. 4. PROVIDE CLOSE STIRRUP ( 100mm O.C. ) BOTTOM BARS
6 - 16 MM Ø MAIN VERTICAL ALONG LENGTH OF SPLICE.
4. PROVIDE ADEQUATE SHORING & PROTECTION FOR REBARS WITH 10 MM Ø TIES @ 25 mm
EXCAVATION OF EARTH. 5-50MM, 2-100MM, 2-150MM
& REST AT 200MM O.C.
6 WALL OPENING DETAILS
C1
S 2 SCALE: 1 : NTS 7 TYPICAL BEAM DETAILS
5 COLUMN SCHEDULE S 2 SCALE: 1 : NTS
SCALE: 1 : 40 MTS
S 2

CIVIL ENGINEER: APPROVED & CONFORMED PROJECT TITLE: SHEET CONTENT SHEET NO.

ANTONIOP. CURVA ONE STOREY RESIDENTIAL BUILDING FOOTING DETAILS


BEAM & COLUMN SCHEDULE

REG. NO: 086681


CIVIL ENGINEER

PTR NO: 0084522


MR. & MRS. ALVARO VALENCIA
WITH ROOF DECK
BRGY. CALANTIPAYAN, LOPEZ, QUEZON
BEAM DIAGRAM
WALL OPENING DETAILS
STRUCTURAL NOTES S-2
TIN: 222-552-996 DATE ISSUED: 01-03-19 PLACE: LOPEZ, QUEZON

Potrebbero piacerti anche