A. GENERAL :
REBAR
1. ALL STRUCTURAL PLANS ,SPECIFICATIONS, AND SHOP
DRAWINGS, SHALL MEET ALL REQUIREMENTS SET BY THE
10 MM Ø DOWELS @
NATIONAL BUILDING CODE, NATIONAL STRUCTURAL CODE T (thickness)
SEE TABLE OF
ANCHORAGE
30 BAR DIA.
(TYPICAL)
1. ALL CONC. HOLLOW BLOCK (CHB) SHALL USE 2-100MM, 2-150MM & REST AT 2-100MM, 2-150MM & REST AT 2-100MM, 2-150MM & REST AT 2-100MM, 2-150MM & REST AT
TENSION BAR
COLUMN
COLUMN
200MM O.C. 200MM O.C. 200MM O.C. 200MM O.C.
NON-LOAD BEARING CHB UNLESS OTHERWISE SPECIFIED.
2. ALL PLASTER AND MORTAR MIXTURE SHALL USE CLASS FTB (FOOTING TIE BEAM) B1 (ROOF DECK BEAM)
B/1:3
WINDOW OPENING 10mm Ø CLOSED STIRRUPS SPACED @
3. PROVIDE LINTEL COLUMN FOR EVERY 3.0M DISTANCE.
4
3-50mm, 3-100mm, 3-150mm & REST
PROVIDE LINTEL BEAM FOR EVERY 3.0M HEIGHT.
E. FOUNDATION:
BEAM SCHEDULE L/5 AT 200mm O.C. L/5
SCALE: 1 : 40 MTS DOOR OPENING
1. THE ALLOWABLE FOUNDATION PRESSURE USED WAS
BASED ON AN ASSUMED VALUE OF 150 KN/SQM BASED ON
S 2
CHAPTER 7 TABLE NO.7-B OF THE NSCP. LENGTH OF SPLICE
40
2. THE LATERAL BEARING USED WAS BASED ON AN 1-16Ø EACH FACE 100 mm o.c.
ASSUMED VALUE OF 60 KN/SQM/M OF DEPTH BASED ON OF OPENING (TYPICAL) 1. CLEAR CONCRETE COVER = 40mm TOP BARS 75 75
CHAPTER 7 TABLE NO. 7-B OF THE NSCP. 2. LOCATE TOP BAR SPLICES AT MIDSPAN
LENGTH OF SPLICE = 40mm ADD'L.TOP BARS
3. THE LATERAL SLIDING USED WAS BASED ON AN ( AS REQUIRED )
3. LOCATE BOTTOM BAR SPLICES 2 X BEAM
ASSUMED VALUE OF 0.35 BASED ON CHAPTER 7 TABLE NO. HEIGHT AWAY FROM FACE OF COLUMN.
7-B OF THE NSCP. 4. PROVIDE CLOSE STIRRUP ( 100mm O.C. ) BOTTOM BARS
6 - 16 MM Ø MAIN VERTICAL ALONG LENGTH OF SPLICE.
4. PROVIDE ADEQUATE SHORING & PROTECTION FOR REBARS WITH 10 MM Ø TIES @ 25 mm
EXCAVATION OF EARTH. 5-50MM, 2-100MM, 2-150MM
& REST AT 200MM O.C.
6 WALL OPENING DETAILS
C1
S 2 SCALE: 1 : NTS 7 TYPICAL BEAM DETAILS
5 COLUMN SCHEDULE S 2 SCALE: 1 : NTS
SCALE: 1 : 40 MTS
S 2
CIVIL ENGINEER: APPROVED & CONFORMED PROJECT TITLE: SHEET CONTENT SHEET NO.