TRANSFORMER TECHNICAL SPECIFICATION

Rev. : 0 TTS. No. : SH12502232IEDC2 Page : 1 of 3

1 Type of transformer Hermetically Sealed (Fully With Oil) Type


2 Installation Indoor
3 Applied standard for design, manufacturing and test IEC 60076
4 Rated power kVA 1250
5 Rated voltage ratio (Primary / Secondary) V 22000 / 400
6 Rated current (Primary / Secondary) A 32.80 / 1804.22

7 Phase 3
8 Rated frequency Hz 50
9 Type of cooling ONAN
10 Vector group Dyn11
11 Polarity N/A
12 Voltage tapping side Primary
Type of tap changer Off-load
Tappings range + / - 2 x 2.5 %
13 Class of insulation Class A
14 Type of oil Mineral oil
15 Material of winding (Primary / Secondary) Copper / Copper
16 Colour of tank RAL 7036
17 Altitude m Not exceeding 1000m above sea level
0
18 Ambient temperature C 40
19 Maximum temperature rise of top oil / winding K 60 / 65
20 No-load loss at rated voltage Tolerances
frequency and normal tap Watts ≤ 1,500 -
21 Load loss at rated current and normal tap (75 0C) Watts ≤ 14,750 -
22 Total loss at rated current and normal tap (75 0C) Watts ≤ 16,250 -
23 Impedance voltage at normal ratio (75 0C) % 5 +/-10 %
24 No-load current % 1.04 +30 %
25 Efficiencies at :
Full load unity power factor % 98.72
Full load 0.8 power factor % 98.40
1/2 load unity power factor % 99.18
1/2 load 0.8 power factor % 98.97
26 Regulation voltage at :
Unity power factor % 1.30
0.8 power factor % 3.91
27 Impulse withstand voltage of winding (Pri. / Sec.) kVp 125 / -
28 Power frequency voltage of winding (Pri. / Sec.) kV 50 / 3

File : SPEC 1250.22.SH.I.EDC2 F103 (Rev.0)


TRANSFORMER TECHNICAL SPECIFICATION

Rev. : 0 TTS. No. : SH12502232IEDC2 Page : 2 of 3

29 Accessories list

Primary with Plug in bushing (24kV 250A) but without Elbow connector

Secondary bushing with terminal connectors

Arcing horns, corrosion-proof

Off load tap changer

Dual voltage switch

Earth terminal

Lifting lug

Lifting eye for cover

Wheel (4 direction type)

Nameplate with connection diagram

Dehydrating breather filled with silica gel

Oil drain, filter press, sampling valve or lower filter valve

Upper filter press valve

Thermometer pocket

Marshalling box

Cable box (Type ……………. )


-
Primary terminal connector Pad type Clamp type
-
( Cable size ………………………... mm2
-
No. of circuit / phase ………………………… )
Secondary terminal connector Pad type Clamp type
-
( Cable size ………………………... mm2
-
No. of circuit / phase ………………………… )
Oil level gauge Without contact With 2 contacts

Oil thermometer (2 pointers) Without contact With 2 contacts

Winding temperature indicator With 2 contacts

Pressure-vacuum gauge Without contact With 2 contacts

Pressure relief device Without contact With 1 contact

Buchholz relay With 2 contacts


SH12502232IEDC2
Reference outline drawing No. ………………………………..

File : SPEC 1250.22.SH.I.EDC2 F103 (Rev.0)


TRANSFORMER TECHNICAL SPECIFICATION

Rev. : 0 TTS. No. : SH12502232IEDC2 Page : 3 of 3

30 Routine test

Each transformer shall pass our standard routine tests, and also pass the following tests in accordance

with the relevant standards :

Measurement of winding resistance.

Measurement of voltage ratio and check of phase displacement.

Measurement of short circuit impedance and load loss.

Measurement of no-load loss and current.

Applied voltage test

Induced voltage withstand test.

Insulation resistance test.

Leakage test.

Oil dielectric strength test.

31 Type test

The following type tests shall be in accordance with the relevant standards :

Full wave lightning impulse test.

Temperature-rise test.

Determination of sound level.

Type test will be carried out on one transformer of the same specification. The costs of all tests and

test reports shall be extra charge.

Customer special requirements

Environmental Product Declaration

We confirm that our products manufactured in accordance with ISO9001 and ISO14001 standards.

All transformer specification from design and material selection for production shall be reviewed to

reduce for environmental impact and aim for environmentally friendly products.
Note : Mark to indicate the applicable information.

File : SPEC 1250.22.SH.I.EDC2 F103 (Rev.0)