Sei sulla pagina 1di 6

JASA KONSTRUKSI

PEMBANGUNAN TANGKI LPG


PRESSURIZED 3 X 3000 MT DI
TERMINAL LPG BALONGAN
BERIKUT SARFAS PENDUKUNG
DOCUMENT NO. : MECHANICAL DATASHEET REV. : 0
FOR INSTRUMENT AIR RECEIVER
BLG-SNT-M-INST-DSH-001-A4 (400-V-02) PAGE : 1 OF 6

PEMILIK : PT. PERTAMINA (PERSERO)


KONTRAKTOR : PT. WIJAYA KARYA (PERSERO) Tbk.
VENDOR : PT.SAHABAT NUSANTARA TEKNOLOGI INOVASI
NAMA PROYEK : JASA KONSTRUKSI PEMBANGUNAN TANGKI LPG
PRESSURIZED 3 X 3000 MT DI TERMINAL LPG
BALONGAN BERIKUT SARFAS PENDUKUNG
LOKASI : INDRAMAYU - JAWA BARAT
NO. PO : TP.01.03/U.LPG-BLG/PPB/XI/0048/2019

13 Desember 2019

0 28-Nov-19 IFA

A 18-Nov-19 IFR

PREP. CHECK. APPR. CHECK. APPR.


REV. DATE DESCRIPTION PT. SAHABAT NUSANTARA
PT. WIJAYA KARYA (PERSERO) Tbk.
TEKNOLOGI INOVASI
JASA KONSTRUKSI
PEMBANGUNAN TANGKI LPG
PRESSURIZED 3 X 3000 MT DI
TERMINAL LPG BALONGAN
BERIKUT SARFAS PENDUKUNG
DOCUMENT NO. : MECHANICAL DATASHEET REV. : 0
FOR INSTRUMENT AIR RECEIVER
BLG-SNT-M-INST-DSH-001-A4 (400-V-02) PAGE : 2 OF 6

REVISION SHEET

No. Revision Page Date Change

1 0 4 28 Nov 19 Merubah impact factor, I menjadi 1.25

2 0 4 28 Nov 19 Internal Ladder termasuk accessories

3 0 4 28 Nov 19 Fluorocarbon Coated

4 0 5 28 Nov 19 Merubah nozzle N5A/B menjadi N5


JASA KONSTRUKSI
PEMBANGUNAN TANGKI LPG
PRESSURIZED 3 X 3000 MT DI
TERMINAL LPG BALONGAN
BERIKUT SARFAS PENDUKUNG
DOCUMENT NO. : MECHANICAL DATASHEET REV. : 0
FOR INSTRUMENT AIR RECEIVER
BLG-SNT-M-INST-DSH-001-A4 (400-V-02) PAGE : 3 OF 6

TABLE OF CONTENT

Description Page No.

Front Page 1
Revision Historical Sheet 2
Table of Content 3
Mechanical Datasheet 4
1 GENERAL INFORMATION
2 APPLICABLE TO : PROPOSAL PURCHASED ASBUILT
3 PROJECT LOCATION : INDRAMAYU, JAWA BARAT
4 EQUIPMENT TAG NO. : 400-V-02
5 EQUIPMENT SERVICE : INSTRUMENT AIR RECEIVER
6 NO. REQUIRED : 1 x 100%
7 DESIGN DATA
8 DESIGN PRES. Barg 12 ORIENTATION VERTICAL
9 OPERATING PRES. Barg 10 DESIGN CODE ASME SECT.VIII DIV.1
o 80 MIGAS
10 DESIGN TEMP. (MIN. / MAX.) c CERTIFICATION
o 30 1910
11 OPERATING TEMP. c VESSEL DIA (ID) mm
o -10 3820
12 MDMT (RATED) c VESSEL LENGTH ( T / T ) mm
13 TEST PRES. HYDROTEST Barg AS PER CALCULATION HEAD TYPE ELLIPSOIDAL 2:1
14 PNEUMATIC Barg N/A SUPPORT TYPE SKIRT
15 CYCLIC SERVICE (YES / NO) NO CLAD THICKNESS mm N/A
16 VAPOUR LIQUID SHELL THICKNESS mm 12
3
17 DENSITY (VAPOR / LIQUID) lb/ft /API - - HEAD THICKNESS mm 12 (MIN. THICKNESS)
18 FLOWRATE MMSCFD/lbmol - - CORR. ALLOWANCE mm 3
19 MASS FLOWRATE lb/hr - - JOINT EFFICIENCIES: SHELL 1
20 VISCOSITY cP - - HEAD 1
21 MOLECULAR WEIGHT - - INSULATION THICKNESS / TYPE NO
22 SURFACE TENSION dyn/cm - - WIND DESIGN
23 SOUR SERVICE NO WIND SPEED mph 83.89
24 TOTAL PACKED HEIGHT mm N/A OCCUPANCY CATEGORY II
25 HEIGHT PER BED mm N/A EXPOSURE CATEGORY B
26 SIZE AND TYPE OF PACKING mm N/A IMPORTANCE FACTOR 1
27 NUMBER OF PACKED SECTION N/A ELEVATION BASE mm +00
28 NUMBER OF REDISTRIBUTORS N/A SEISMIC DESIGN
29 TRAY : TYPE N/A SITE CLASS C
30 SPACING / NUMBER REQUIRED N/A IMPORTANCE FACTOR 1.25
31 RELIEF VALVE YES (2") SRA (SS) g 1 g (100%)
32 TYPE /SIZE N/A SRA (S1) g 0.40 g (40 %)
33 SETTING PRESS. Barg N/A
34 NUMBER REQ'D N/A
35 FIREPROOFING NO
36 ESTIMATED WEIGHT
37 TOTAL WEIGHT (SHIPPING WEIGHT) AS PER CALCULATION kg WEIGHT OF INTERNAL PARTS TBC (NOTE 3) kg
38 TOTAL WEIGHT, OPERATING AS PER CALCULATION kg WEIGHT OF PLATFORM / LADDER AS PER CALCULATION kg
39 TOTAL WEIGHT, FULL OF WATER AS PER CALCULATION kg WEIGHT OF FIRE PROOFING N/A kg
40 ACCESSORIES
41 NAME PLATE W/ BRACKET TAILING LUG ANCHOR BOLT SLIDING PLATE
42 MANHOLE DAVIT PLATFORM & LADDER TEMPLATE FOR ANCHOR BOLTS EARTHING LUG
43 INSULATION SUPPORT / CLIPS PLATFORM & LADDER CLIPS FIRE PROOFING SUPPORT INTERNAL LADDER/ACC.
44 LIFTING LUG PIPE SUPPORT CLIPS TOP DAVIT CATHODIC SUPPORT
45 MATERIAL SPECIFICATION
46 PARTS DESCRIPTION ASTM / ASME NO. PARTS DESCRIPTION ASTM / ASME NO.
47 SHELL SA 516 Gr.70 INTERNAL REMOV/NON.REMOV N/A
48 HEADS SA 516 Gr.70 GASKETS SW INNER OUTER SS 316L
49 CLADDING / LINNING NO NAME PLATE / BRACKET SS 304 / SA 516 Gr 70
50 NOZZLE NECK (PIPES) SA 106 Gr.B EAR LUG / TAILING LUG SA 36
51 NOZZLE NECK (PLATES) SA 516 Gr.70 ANCHOR BOLT / NUTS SA 307 Gr.B
52 NOZZLE NECK (FORGINGS) SA 105 STUD BOLT / NUTS SA 193 Gr.B7 / SA 194 Gr.2H 9 (FCC)
53 FORGED FLANGES SA 105 INTERNAL BOLT / NUTS N/A
54 REINFORCING PADS SA 516 Gr.70 STRUCT. BOLT / NUTS N/A
55 STIFFENER RINGS N/A STRUCT.PLATFORM / LADDER SS 400 (HDG)
56 SKIRT SA 516 Gr.70 & SA 36 PLATFORM / LADDER CLIP SA 36 (HDG)
57 BASE RING / PLATE SA 36 PIPE FITTINGS SA 234 WPB
58 INTERNAL PART N/A EARTHING LUG SS 304
59 FABRICATION AND INSPECTION REQUIREMENTS
60 INSPECTION AUTHORITY MIGAS, PURCHASER, COMPANY
61 INSPECTION FULL
62 STRESS RELIEVING AS PER CODE & SPECIFICATION Please Fill up as per calculation
63 POST WELD HEAT TREATMENT NO
64 RADIOGRAPHY 100%
65 OTHER NON DESTRUCTIVE TESTING AS PER CODE & SPECIFICATION
66 HARDNESS TEST NO
67 ASME CODE STAMP NO Note 3 yang mana?
68 IMPACT TEST NO
69 MATERIAL CERTIFICATE
70 CHEMICAL ANALYSIS YES
71 MECHANICAL DATA YES
72 PAINTING AND INTERNAL COATING YES, EXTERNAL PAINTING (AS PER SPEC.)
73
1 NOZZLE INFORMATION
2
MIN. OUTSIDE
3 Mark QTY SIZE RATING FACE TYPE SERVICE REMARKS
PROJ. (mm)
4
5 N1 1 2" #150 RF WN 150 INLET
6 N2 1 2" #150 RF WN 150 UTILITY CONNECTION
7 N3 1 2" #150 RF WN 150 DRAIN
8 N4 1 2" #150 RF WN 150 PSV
9 N5 1 2" #150 RF WN 150 PG
10 N6 1 2" #150 RF WN 150 SPARE C/W BLIND FLANGE
11
12
13
14 MANHOLES ETC.
15 MW 1 20" #150 RF WN 250 MANWAY C.W BLIND FLANGE DAVIT ARM
16
17
18
19
20
21
22
23
24 REFERENCE DRAWINGS / LIST (Note 24)
25 NO. DOCUMENT TITLE
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
1 VESSEL SKETCH
2
3 Unit in mm
4
5
6
7
8
9
10 N4 N5 N6
11 2" 2" 2"
12
13
14
15
16
17
18
19
20
21 N2
2"
22 N1
2"
23
24
25
26
27
28
29
30
31
32
33
34
35
36 18176
M1
37 24783 20"
38 35633
39
40
41
42 SV2 SV3
43 2" 2"

44
N3 SO1
45 2" 8"
46 SO2
16"
47
48
49
50
51
52
53
54
55 ELEVATION
56
57
58
59
60
61