Rediographic safety distasnce calculation for Operator & General Public

Assumptions:
a. Working days/yr: 300
b. Working hrs/day: 12

Data:
a. Permisible limit for Radiation worker: 5000 mrem 500 mSv ref.: https://ehs.research.uiowa.e
b. Initial Source (Ir 92) Strength (Curies): 88
c. Half Life for Ir 92 74 days

Calculation:
a. Per day per hour absorption limit: 0.138889 mSv/hr 138.8889 uSv/hr
b. Source life from initial source strength date 4 days
c. Current Strength in curies 84.76387 Curies 0.054054
d. Convertion (Curies to GBq or sievert/metric) 3136.263 GBq
GBq to mSv/hr @ 1m 470.4395 mSv/hr @ 1m
470439.5 uSv/hr @ 1m
e. Colimator used 2 TVL 4704.395 uSv/hr @ 1m
f. Radiation strength @ m 10 47.04395 uSv/hr

Result
://ehs.research.uiowa.edu/31-maximum-permissible-dose-limits