Nutanix Complete Cluster merges commodity storage and servers into a radically simple
building block for your virtualized datacenter. Each Nutanix block is mountable on a standard
19” rack with available space for 4 industry-standard x86 server nodes delivering high-density
virtualization in an 85-lb appliance.
Each node individually run a standard hypervisor and is complete with processors, memory and
local storage (SSDs and hard disks). Designed for virtualization, the system runs and stores
VMs in a radically simple building block that eliminates the need for a costly SAN.
Configuration options; Configurable per Node; Configuration options; Configurable per Node;
Memory 48 GB, 96 GB, or 192 GB 192 GB, up to 768 GB per Block 128 GB or 256 GB 512 GB, up to 1 TB per Block
Certifications UL, CSA, CE, VCCI, KCC, C-Tick UL, CSA, CE, VCCI, KCC, C-Tick
High
Availability N-way fully fault-tolerant controller fabric N-way fully fault-tolerant controller fabric
Hypervisor
Support VMware vSphere 5.x, KVM VMware vSphere 5.x, KVM
*Each node contains remote lights-out management port
Block Specifications
Block Dimensions Height: 3.5’’ (89mm), Width: 17.2’’ (437mm), Depth:28’’ (711mm) Height: 3.5’’ (88mm), Width: 17.6’’ (447mm), Depth: 30.5’’ (775mm)
Node Dimensions Width: 6.8”(173mm), Length: 22.5” (572mm) Width: 6.6”(172mm), Length: 20.6” (572mm)
Block Weight
85 lbs. (38.6kg) / 95 lbs. (43kg) 72.8 lbs. (33kg) / 101 lbs. (45.8kg)
(stand-alone / package)
Node Weight 7 lbs (3.2kg) 7 lbs (3.14kg)
Form Factor 28” (711mm) 2U rack-mount chassis 30.5” (775mm) 2U rack-mount chassis
System Cooling 4x80mm heavy duty fans with PWM fan speed controls 4x80mm heavy duty fans with PWM fan speed controls
Op Temp Rng: 50°-95°F (10°-35°C), Non-Op Temp Rng: 32°-110°F (0°-40°C) Op Temp Rng: 41°-95°F (5°-35°C), Non-Op Temp Rng: -40°-149°F (-40°-65°C)
Operating Environment Op Humidity Rng (non-condensing): 20-95%, Non-Op Humidity Rng: 5-95% Op Humidity Rng (non-condensing): 20-80%, Non-Op Humidity Rng: 5-95%
Power Supply AC In: 1.1kW Out @100-140V, 13.5-9.5A, 50-60HZ; AC In: 1.4kW Out @200-240V, 9.6A, 50-60Hz
(Dual power supply/block) 1.4kW Out @180-240V, 9.5-7.0A, 50-60Hz
Power Consumption
1350W maximum 1400W maximum
(Per block)
Operating Requirements Input Voltage: 100-240V AC auto-range Input Voltage: 200-240V AC auto-range