Sei sulla pagina 1di 32

BORDEROU DE PIESE SCRISE

FOAIE DE CAPAT
BORDEROU DE PIESE SCRISE si DESENATE
LISTA DE SEMNATURI
REFERAT VERIFICATOR
PROGRAM DE CONTROL
STABILIREA CATEGORIEI DE IMPORTANTA
MEMORIU TEHNIC DE REZISTENTA
BREVIAR DE CALCUL STRUCTURA
CAIETE DE SARCINI STRUCTURA
ANTEMASURATORI SI EXTRASE DE RESURSE

BORDEROU DE PIESE DESENATE

UNITATE DE PRODUCTIE
FUNDATII
R1’ – PLAN SAPATURA
R1 – PLAN FUNDATII
F1 – DETALII FUNDATIE F1
F2 – DETALII FUNDATIE F2
F3 – DETALII FUNDATIE F3
F4 – DETALII FUNDATIE F4
F5 – DETALII FUNDATIE F5
F6 – DETALII FUNDATIE F6
F7 – DETALII FUNDATIE F7
F8 – DETALII FUNDATIE F8
F9 – DETALII FUNDATIE F9
GF1-GF2 – DETALII GRINZI DE FUNDARE
EXTRAS1 – EXTRAS CENTRALIZATOR FUNDATII

PARDOSEALA
R1b – PLAN PARDOSEALA
R1c – PLAN CANIVOURI SI RIGOLE PARDOSEALA
BMC1 – PLAN COFRAJ SI ARMARE ZONA BASA MASINA DE CURATENIE
CE1 – COFRAJ SI ARMARE CANIVOURI ELECTRICE
RC1 – COFRAJ SI ARMARE RADIERE COMPRESOARE

PAHARE PREFABRICATE
R3 – PLAN DISPUNERE PAHARE
PAHAR/1-c – PLAN COFRAJ PAHAR/1
PAHAR/3-c – PLAN COFRAJ PAHAR/3
PAHAR/1-a – PLAN ARMARE PAHAR/1
PAHAR/3-a – PLAN ARMARE PAHAR/3
PRZ8 – ANSAMBLU METALIC PRZ8

PARAPETI PREFABRICATI
R4 - PLAN DISPUNERE PARAPETI PREFABRICATI
PP/1-c – PLAN COFRAJ PARAPET PP/1
PP/2-c – PLAN COFRAJ PARAPET PP/2
PP/3-c – PLAN COFRAJ PARAPET PP/3
PP/4-c – PLAN COFRAJ PARAPET PP/4
PP/5-c – PLAN COFRAJ PARAPET PP/5
PP/6-c – PLAN COFRAJ PARAPET PP/6
PP/7-c – PLAN COFRAJ PARAPET PP/7
PP/8-c – PLAN COFRAJ PARAPET PP/8
PP/9-c – PLAN COFRAJ PARAPET PP/9
PP/10-c – PLAN COFRAJ PARAPET PP/10
PP/11-c – PLAN COFRAJ PARAPET PP/11
PP/12-c – PLAN COFRAJ PARAPET PP/12
PP/13-c – PLAN COFRAJ PARAPET PP/13
PP/14-c – PLAN COFRAJ PARAPET PP/14
PP/15-c – PLAN COFRAJ PARAPET PP/15
PP/16-c – PLAN COFRAJ PARAPET PP/16
PP/17-c – PLAN COFRAJ PARAPET PP/17
PP/18-c – PLAN COFRAJ PARAPET PP/18
PP/19-c – PLAN COFRAJ PARAPET PP/19
PP/20-c – PLAN COFRAJ PARAPET PP/20
PP/21-c – PLAN COFRAJ PARAPET PP/21
PP/22-c – PLAN COFRAJ PARAPET PP/22
PP/23-c – PLAN COFRAJ PARAPET PP/23
PP/24-c – PLAN COFRAJ PARAPET PP/24
PP/25-c – PLAN COFRAJ PARAPET PP/25
PP/26-c – PLAN COFRAJ PARAPET PP/26
PP/27-c – PLAN COFRAJ PARAPET PP/27
PP/28-c – PLAN COFRAJ PARAPET PP/28
PP/29-c – PLAN COFRAJ PARAPET PP/29
PP/30-c – PLAN COFRAJ PARAPET PP/30
PP/31-c – PLAN COFRAJ PARAPET PP/31
PP/32-c – PLAN COFRAJ PARAPET PP/32
PP/33-c – PLAN COFRAJ PARAPET PP/33
PP/34-c – PLAN COFRAJ PARAPET PP/34
PP/35-c – PLAN COFRAJ PARAPET PP/35
PP/36-c – PLAN COFRAJ PARAPET PP/36
PP/1-a – PLAN ARMARE PARAPET PP/1
PP/2-a – PLAN ARMARE PARAPET PP/2
PP/3-a – PLAN ARMARE PARAPET PP/3
PP/4-a – PLAN ARMARE PARAPET PP/4
PP/5-a – PLAN ARMARE PARAPET PP/5
PP/6-a – PLAN ARMARE PARAPET PP/6
PP/8-a – PLAN ARMARE PARAPET PP/8
PP/9-a – PLAN ARMARE PARAPET PP/9
PP/10-a – PLAN ARMARE PARAPET PP/10
PP/12-a – PLAN ARMARE PARAPET PP/12
PP/13-a – PLAN ARMARE PARAPET PP/13
PP/14-a – PLAN ARMARE PARAPET PP/14
PP/15-a – PLAN ARMARE PARAPET PP/15
PP/16-a – PLAN ARMARE PARAPET PP/16
PP/17-a – PLAN ARMARE PARAPET PP/17
PP/18-a – PLAN ARMARE PARAPET PP/18
PP/19-a – PLAN ARMARE PARAPET PP/19
PP/20-a – PLAN ARMARE PARAPET PP/20
PP/21-a – PLAN ARMARE PARAPET PP/21
PP/22-a – PLAN ARMARE PARAPET PP/22
PP/23-a – PLAN ARMARE PARAPET PP/23
PP/24-a – PLAN ARMARE PARAPET PP/24
PP/25-a – PLAN ARMARE PARAPET PP/25
PP/26-a – PLAN ARMARE PARAPET PP/26
PP/27-a – PLAN ARMARE PARAPET PP/27
PP/28-a – PLAN ARMARE PARAPET PP/28
PP/29-a – PLAN ARMARE PARAPET PP/29
PP/30-a – PLAN ARMARE PARAPET PP/30
PP/31-a – PLAN ARMARE PARAPET PP/31
PP/32-a – PLAN ARMARE PARAPET PP/32
PP/33-a – PLAN ARMARE PARAPET PP/33
PP/34-a – PLAN ARMARE PARAPET PP/34
PP/35-a – PLAN ARMARE PARAPET PP/35
PP/36-a – PLAN ARMARE PARAPET PP/36

STALPI PREFABRICATI
R5 – PLAN DISPUNERE STALPI PREFABRICATI
S/16-c – PLAN COFRAJ STALP S/16
S/18-c – PLAN COFRAJ STALP S/18
S/20-c – PLAN COFRAJ STALP S/20
S/21-c – PLAN COFRAJ STALP S/21
S/22-c – PLAN COFRAJ STALP S/22
S/23-c – PLAN COFRAJ STALP S/23
S/24-c – PLAN COFRAJ STALP S/24
S/25-c – PLAN COFRAJ STALP S/25
S/26-c – PLAN COFRAJ STALP S/26
S/27-c – PLAN COFRAJ STALP S/27
S/28-c – PLAN COFRAJ STALP S/28
S/29-c – PLAN COFRAJ STALP S/29
S/30-c – PLAN COFRAJ STALP S/30
S/31-c – PLAN COFRAJ STALP S/31
S/32-c – PLAN COFRAJ STALP S/32
S/33-a – PLAN ARMARE STALP S/33

S/18-a – PLAN ARMARE STALP S/18


S/20-a – PLAN ARMARE STALP S/20
S/22-a – PLAN ARMARE STALP S/22
S/25-a – PLAN ARMARE STALP S/25
S/26-a – PLAN ARMARE STALP S/26
S/27-a – PLAN ARMARE STALP S/27
S/28-a – PLAN ARMARE STALP S/28
S/30-a – PLAN ARMARE STALP S/30
S/31-a – PLAN ARMARE STALP S/31
S/32-a – PLAN ARMARE STALP S/32

GRINZI PLANSEU PREFABRICATE


R6 – PLAN DISPUNERE GRINZI PLANSEU
GP/3-c – PLAN COFRAJ GRINDA PLANSEU GP/3
GP/4-c – PLAN COFRAJ GRINDA PLANSEU GP/4
GP/5-c – PLAN COFRAJ GRINDA PLANSEU GP/5
GP/6-c – PLAN COFRAJ GRINDA PLANSEU GP/6
GP/3-a – PLAN ARMARE GRINDA PLANSEU GP/3
GP/4-a – PLAN ARMARE GRINDA PLANSEU GP/4
GP/5-a – PLAN ARMARE GRINDA PLANSEU GP/5
GP/6-a – PLAN ARMARE GRINDA PLANSEU GP/6

FASII CU GOLURI
R7 – PLAN DISPUNERE FASII CU GOLURI PRECOMPRIMATE
FG/1 – PLAN COFRAJ SI ARMARE FASIE FG/1
FG/2 – PLAN COFRAJ SI ARMARE FASIE FG/2

GRINZI PRINCIPALE PREFABRICATE


R8 – PLAN DISPUNERE GRINZI PRINCIPALE
GPR/1-c – PLAN COFRAJ GPR/1
GPR/2-c – PLAN COFRAJ GPR/2
GPR/3-c – PLAN COFRAJ GPR/3
GPR/4-c – PLAN COFRAJ GPR/4
GPR/5-c – PLAN COFRAJ GPR/5
GPR/6-c – PLAN COFRAJ GPR/6
GPR/7-c – PLAN COFRAJ GPR/7
GPR/8-c – PLAN COFRAJ GPR/8
GPR/5-a – PLAN ARMARE GPR/5
GPR/6-a – PLAN ARMARE GPR/6

PANE PREFABRICATE
R9 – PLAN DISPUNERE PANE
PN/1-c – PLAN COFRAJ PN/1
PN/1-a – PLAN ARMARE PN/1

DETALII IMBINARE PREFABRICATE


D1 - DETALII PRINDERE PARAPETI -1-
D2 - DETALII PRINDERE PARAPETI -2-
D3 - DETALII NODURI PREFABRICATE -1-
D4 - DETALII NODURI PREFABRICATE -2-
D5 - DETALII NEOPREN PREFABRICATE

CONFECTII METALICE ANSAMBLE INGLOBATE SI DE PRINDERE


BL/3 – ANSAMBLUL BL/3
BL/4 – ANSAMBLUL BL/4
BL/5 – ANSAMBLUL BL/5
DIST/1 – ANSAMBLUL DIST/1
PK/1 – ANSAMBLUL PK/1
PRP/1 – ANSAMBLUL PRP/1
PRP/2 – ANSAMBLUL PRP/2
PRP/3 – ANSAMBLUL PRP/3
PRZ/2 – ANSAMBLUL PRZ/2
PRZ/3 – ANSAMBLUL PRZ/3
PRZ/4 – ANSAMBLUL PRZ/4
PRZ/5 – ANSAMBLUL PRZ/5
PRZ/6 – ANSAMBLUL PRZ/6
PRZ/7 – ANSAMBLUL PRZ/7
PRZ/8 – ANSAMBLUL PRZ/8
PRZ/9 – ANSAMBLUL PRZ/9
PRZ/10 – ANSAMBLUL PRZ/10
DEBITARE/1 – DEBITARE PROFILE SI PLACI METALICE ANSAMBLE
INGLOBATE SI DE PRINDERE STRUCTURI PREFABRICATE
CONTRAVANTUIRI SI RIGLE IN PLANUL INVELITORII
R15 – PLAN MONTAJ STRUCTURI METALICE IN PLANUL INVELITORII
AM/10 – ANSAMBLU AM/10
AM/14 – ANSAMBLU AM/14
AM/15 – ANSAMBLU AM/15
AM/16 – ANSAMBLU AM/16
AM/17 – ANSAMBLU AM/17
AM/19 – ANSAMBLU AM/19
AM/25 – ANSAMBLU AM/25
BL/1 – ANSAMBLUL BL/1
BL/7 – ANSAMBLUL BL/7
CV/7 – ANSAMBLU CV/7
CV/8 – ANSAMBLU CV/8
CV/9 – ANSAMBLU CV/9
M/6 – ANSAMBLU M/6
DEBITARE2 – DEBITARE PROFILE SI PLACI METALICE RIGLE METALICE,
CONTRAVANTUIRI

SUPRABETONARE
R10 – PLAN COFRAJ SUPRABETONARE
R11 - PLAN ARMARE CU PLASE SUDATE SUPRABETONARE
R12 - PLAN ARMARE CU BARE INDEPENDENTE SUPRABETONARE
R13 - PLAN ARMARE NERVURI SUPRABETONARE

PERETI DE ZIDARIE
R14 - COFRARE SI ARMARE CENTURI SI SAMBURI PERETI RF

STRUCTURI METALICE DE SUSTINERE LUMINATOARE, ANCADRAMENTE,


BAIONETE, SCARA PISICA, COPERTINE
R15 - PLAN MONTAJ RIGLE SI CONTRAVANTUIRI IN PLANUL INVELITORII
R16 - PANOTAJ TABLA CUTATA INVELITOARE
R17 - PLAN MONTAJ STRUCTURI METALICE COTA +0.00
R18 - SECTIUNI GENERALE MONTAJ STRUCTURI METALICE -1-
R19 - SECTIUNI GENERALE MONTAJ STRUCTURI METALICE -2-
R20 - VEDERE IZOMETRICA STRUCTURA
R21 - PLAN GENERAL MONTAJ CARCASE CU BULOANE -0.40m
R22 - PLAN GENERAL MONTAJ STRUCTURI PE ACOPERIS SI IN PLANUL
INVELITORII
R23 - SECTIUNI GENERALE MONTAJ ESAFODAJE ECHIPAMENTE
R24 - SECTIUNI GENERALE MONTAJ SAS INTRARE SI SCARA METALICA

CABINA POARTA
FUNDATII
cR1 - PLAN FUNDATII
cR2 - DETALII FUNDATII
cR3 - PLAN ARMARE TALPI FUNDATII
cR4 - PLAN ARMARE DE MONTAJ
cR5 - PLAN ARMARE SUPERIOARA ELEVATII
cR6 - PLAN ARMARE SOCLU
cR7 - EXTRAS DE ARMARE BARE FUNDATII CABINA POARTA
SUPRASTRUCTURA
cR8 - VEDERE IZOMETRICA STRUCTURA
cR9 - PLAN MONTAJ STALPI -0.05
cR10 - SECTIUNI MONTAJ STRUCTURA -1-
cR11 - SECTIUNI MONTAJ STRUCTURA -2-
cR12 - SECTIUNI MONTAJ STRUCTURA -3-
cR13 - PLAN MONTAJ GRINZI SI CONTRAVANTUIRI
cR14 - PANOTAJ TABLA AUTOPORTANTA

REZERVOARE CO2 si N2
FUNDATII
cvR1 - PLAN FUNDATII
cvR2 – PLAN ARMARE FUNDATII

REZERVOARE INCENDIU SI TEHNOLOGIC


FUNDATII
rez.R1 - PLAN FUNDATII
rez.R2 - DETALII FUNDATIE Fr1 - 120x120cm
rez.R3 - DETALII GRINDA DE ECHILIBRARE SI SOCLU
rez.R4 - PLAN ARMARE GRINZI DE ECHILIBRARE SI SOCLU

SUPRASTRUCTURA
rez.R5 - VEDERE IZOMETRICA STRUCTURA
rez.R6 - PLAN MONTAJ STALPI
rez.R7 - SECTIUNI MONTAJ STRUCTURA -1-
rez.R8 - SECTIUNI MONTAJ STRUCTURA -2-
rez.R9 - PLAN MONTAJ GRINZI SI CONTRAVANTUIRI
rez.R10 - PANOTAJ TABLA AUTOPORTANTA

TOTEM
t.R1 - PLAN, VEDERI SI SECTIUNI PERETE TOTEM
t.R2 - DETALII FUNDATIE PERETE TOTEM
t.R3 - PLAN ARMARE FUNDATIE
t.R4 - PLAN ARMARE SAMBURI SI CENTURI

IMPREJMUIRE
A5.1 - DETALII MODUL IMPREJMUIRE
i.R1 - DETALII MODUL IMPREJMUIRE
i.R2 - POARTA GLISANTA 10.60M - 1BUC
i.R3 - POARTA BATANTA ACCES 6.00M - 2 BUC
i.R4 - POARTA BATANTA ACCES 1.20M - 2 BUC
i.R5 - POARTA BATANTA ACCES 2.00M - 1 BUC

ZIDURI DE SPRIJIN
zR1 - PLAN SI ELEVATII COFRAJ ZIDURI DE SPRIJIN ANDOCARE
zR2 - PLAN SI ELEVATII ARMARE ZIDURI DE SPRIJIN ANDOCARE

UZINARE STRUCTURI METALICE


ANSAMBLE METALICE
ANSAMBL
A1 - U A1
ANSAMBL
A2 - U A2
ANSAMBL
A3 - U A3
ANSAMBL
A4 - U A4
ANSAMBL
A5 - U A5
ANSAMBL
A6 - U A6
ANSAMBL
A7 - U A7
ANSAMBL
A8 - U A8
ANSAMBL
A9 - U A9
ANSAMBL
A10 - U A10
ANSAMBL
A11 - U A11
A12 - ANSAMBL A12
U
ANSAMBL
A13 - U A13
ANSAMBL
A14 - U A14
ANSAMBL
A15 - U A15
ANSAMBL
A16 - U A16
ANSAMBL
A17 - U A17
ANSAMBL
A18 - U A18
ANSAMBL
A19 - U A19
ANSAMBL
A20 - U A20
ANSAMBL
A21 - U A21
ANSAMBL
A22 - U A22
ANSAMBL
A23 - U A23
ANSAMBL
A24 - U A24
ANSAMBL
A25 - U A25
ANSAMBL
A26 - U A26
ANSAMBL
A27 - U A27
ANSAMBL
A28 - U A28
ANSAMBL
A29 - U A29
ANSAMBL
A30 - U A30
ANSAMBL
A31 - U A31
ANSAMBL
A32 - U A32
ANSAMBL
A33 - U A33
ANSAMBL
A34 - U A34
ANSAMBL
A35 - U A35
ANSAMBL
A36 - U A36
ANSAMBL
A37 - U A37
ANSAMBL
A38 - U A38
ANSAMBL
A39 - U A39
ANSAMBL
A40 - U A40
ANSAMBL
A41 - U A41
ANSAMBL
A42 - U A42
ANSAMBL
A43 - U A43
ANSAMBL
A70 - U A70
ANSAMBL
A71 - U A71
ANSAMBL
A72 - U A72
ANSAMBL
A73 - U A73
ANSAMBL
A75 - U A75
ANSAMBL
A76 - U A76
ANSAMBL
A77 - U A77
ANSAMBL
A78 - U A78
ANSAMBL
A80 - U A80
ANSAMBL
A81 - U A81
ANSAMBL
A82 - U A82
ANSAMBL
A83 - U A83
ANSAMBL
A85 - U A85
ANSAMBL
A86 - U A86
ANSAMBL
A87 - U A87
ANSAMBL
A88 - U A88
ANSAMBL
A89 - U A89
ANSAMBL
A90 - U A90
ANSAMBL
A91 - U A91
ANSAMBL
A92 - U A92
ANSAMBL
A95 - U A95
ANSAMBL
A96 - U A96
ANSAMBL
AM1 - U AM1
ANSAMBL
AM2 - U AM2
ANSAMBL
AM3 - U AM3
ANSAMBL
AM4 - U AM4
ANSAMBL
AM5 - U AM5
ANSAMBL
AM6 - U AM6
ANSAMBL
AM7 - U AM7
AM8 - ANSAMBL AM8
U
ANSAMBL
AM9 - U AM9
ANSAMBL
AM11 - U AM11
ANSAMBL
AM12 - U AM12
ANSAMBL
AM13 - U AM13
ANSAMBL
AM18 - U AM18
ANSAMBL
AM20 - U AM20
ANSAMBL
AM21 - U AM21
ANSAMBL
AM22 - U AM22
ANSAMBL
AM23 - U AM23
ANSAMBL
AM26 - U AM26
ANSAMBL
AM27 - U AM27
ANSAMBL
AM28 - U AM28
ANSAMBL
AM29 - U AM29
ANSAMBL
BL2 - U BL2
ANSAMBL
BL3 - U BL3
ANSAMBL
BL4 - U BL4
ANSAMBL
BL5 - U BL5
ANSAMBL
BL6 - U BL6
ANSAMBL
BL8 - U BL8
ANSAMBL
BL9 - U BL9
ANSAMBL
BL11 - U BL11
ANSAMBL
BS1 - U BS1
ANSAMBL
BS2 - U BS2
ANSAMBL
BS3 - U BS3
ANSAMBL
BS4 - U BS4
ANSAMBL
BS5 - U BS5
ANSAMBL
BS6 - U BS6
ANSAMBL
BS7 - U BS7
ANSAMBL
BT1 - U BT1
ANSAMBL
BT2 - U BT2
ANSAMBL
BT3 - U BT3
ANSAMBL
BT4 - U BT4
ANSAMBL
BT5 - U BT5
ANSAMBL
BT6 - U BT6
ANSAMBL
BT7 - U BT7
ANSAMBL
BT8 - U BT8
ANSAMBL
BT9 - U BT9
ANSAMBL
BT10 - U BT10
ANSAMBL
BT11 - U BT11
ANSAMBL
BT12 - U BT12
ANSAMBL
BT13 - U BT13
ANSAMBL
BT14 - U BT14
ANSAMBL
BT15 - U BT15
ANSAMBL
BT16 - U BT16
ANSAMBL
BT17 - U BT17
ANSAMBL
BT18 - U BT18
ANSAMBL
BT19 - U BT19
ANSAMBL
BT20 - U BT20
ANSAMBL
BT21 - U BT21
ANSAMBL
CARCASA1 - U CARCASA1
ANSAMBL
CARCASA2 - U CARCASA2
ANSAMBL
CP-A1 - U CP-A1
ANSAMBL
CP-A2 - U CP-A2
ANSAMBL
CP-A3 - U CP-A3
ANSAMBL
CP-A4 - U CP-A4
ANSAMBL
CP-A5 - U CP-A5
ANSAMBL
CP-A6 - U CP-A6
ANSAMBL
CP-A7 - U CP-A7
ANSAMBL
CP-A8 - U CP-A8
ANSAMBL
CP-CV1 - U CP-CV1
CP-CV2 - ANSAMBL CP-CV2
U
ANSAMBL
CP-CV3 - U CP-CV3
ANSAMBL
CP-G1 - U CP-G1
ANSAMBL
CP-G2 - U CP-G2
ANSAMBL
CP-G3 - U CP-G3
ANSAMBL
CP-G4 - U CP-G4
ANSAMBL
CP-G5 - U CP-G5
ANSAMBL
CP-G6 - U CP-G6
ANSAMBL
CP-G7 - U CP-G7
ANSAMBL
CP-G8 - U CP-G8
ANSAMBL
CP-G9 - U CP-G9
ANSAMBL
CP-G10 - U CP-G10
ANSAMBL
CP-G11 - U CP-G11
ANSAMBL
CP-G12 - U CP-G12
ANSAMBL
CP-G13 - U CP-G13
ANSAMBL
CP-ST1 - U CP-ST1
ANSAMBL
CP-ST2 - U CP-ST2
ANSAMBL
CP-ST3 - U CP-ST3
ANSAMBL
CP-ST4 - U CP-ST4
ANSAMBL
CP-ST5 - U CP-ST5
ANSAMBL
CP-ST6 - U CP-ST6
ANSAMBL
CP-ST7 - U CP-ST7
ANSAMBL
CP-ST8 - U CP-ST8
ANSAMBL
CT1 - U CT1
ANSAMBL
CV2 - U CV2
ANSAMBL
CV3 - U CV3
ANSAMBL
CV10 - U CV10
ANSAMBL
CV15 - U CV15
ANSAMBL
E1 - U E1
ANSAMBL
E2 - U E2
ANSAMBL
E3 - U E3
ANSAMBL
E4 - U E4
ANSAMBL
E5 - U E5
ANSAMBL
E6 - U E6
ANSAMBL
E7 - U E7
ANSAMBL
E8 - U E8
ANSAMBL
E9 - U E9
ANSAMBL
E10 - U E10
ANSAMBL
E11 - U E11
ANSAMBL
E12 - U E12
ANSAMBL
E13 - U E13
ANSAMBL
E14 - U E14
ANSAMBL
E15 - U E15
ANSAMBL
E16 - U E16
ANSAMBL
E17 - U E17
ANSAMBL
E18 - U E18
ANSAMBL
E19 - U E19
ANSAMBL
E20 - U E20
ANSAMBL
E21 - U E21
ANSAMBL
E22 - U E22
ANSAMBL
E23 - U E23
ANSAMBL
E24 - U E24
ANSAMBL
E25 - U E25
ANSAMBL
E26 - U E26
ANSAMBL
E27 - U E27
ANSAMBL
E28 - U E28
ANSAMBL
E29 - U E29
ANSAMBL
E30 - U E30
ANSAMBL
E31 - U E31
ANSAMBL
E32 - U E32
ANSAMBL
E33 - U E33
E34 - ANSAMBL E34
U
ANSAMBL
E35 - U E35
ANSAMBL
E36 - U E36
ANSAMBL
E37 - U E37
ANSAMBL
E38 - U E38
ANSAMBL
E39 - U E39
ANSAMBL
E40 - U E40
ANSAMBL
E41 - U E41
ANSAMBL
E42 - U E42
ANSAMBL
E43 - U E43
ANSAMBL
E44 - U E44
ANSAMBL
E45 - U E45
ANSAMBL
E46 - U E46
ANSAMBL
E47 - U E47
ANSAMBL
E48 - U E48
ANSAMBL
E49 - U E49
ANSAMBL
E50 - U E50
ANSAMBL
E51 - U E51
ANSAMBL
E52 - U E52
ANSAMBL
E53 - U E53
ANSAMBL
E54 - U E54
ANSAMBL
E55 - U E55
ANSAMBL
E56 - U E56
ANSAMBL
G1 - U G1
ANSAMBL
G2 - U G2
ANSAMBL
G3 - U G3
ANSAMBL
G4 - U G4
ANSAMBL
G5 - U G5
ANSAMBL
G6 - U G6
ANSAMBL
G7 - U G7
ANSAMBL
G8 - U G8
ANSAMBL
G11 - U G11
ANSAMBL
G15 - U G15
ANSAMBL
M3 - U M3
ANSAMBL
M7 - U M7
ANSAMBL
PT4 - U PT4
ANSAMBL
PT5 - U PT5
ANSAMBL
PT7 - U PT7
ANSAMBL
PT8 - U PT8
ANSAMBL
PT9 - U PT9
ANSAMBL
PT10 - U PT10
ANSAMBL
PT11 - U PT11
ANSAMBL
PT12 - U PT12
ANSAMBL
PT13 - U PT13
ANSAMBL
PT14 - U PT14
ANSAMBL
PT15 - U PT15
ANSAMBL
PT17 - U PT17
ANSAMBL
PT18 - U PT18
ANSAMBL
PT19 - U PT19
ANSAMBL
PT20 - U PT20
ANSAMBL
PT21 - U PT21
ANSAMBL
PT22 - U PT22
ANSAMBL
PT23 - U PT23
ANSAMBL
PT24 - U PT24
ANSAMBL
PT25 - U PT25
ANSAMBL
PT26 - U PT26
ANSAMBL
R-A1 - U R-A1
ANSAMBL
R-A2 - U R-A2
ANSAMBL
R-A3 - U R-A3
ANSAMBL
R-A4 - U R-A4
ANSAMBL
R-A5 - U R-A5
R-BT1 - ANSAMBL R-BT1
U
ANSAMBL
R-BT2 - U R-BT2
ANSAMBL
R-CAR1 - U R-CAR1
ANSAMBL
R-CV1 - U R-CV1
ANSAMBL
R-CV2 - U R-CV2
ANSAMBL
R-CV3 - U R-CV3
ANSAMBL
R-CV4 - U R-CV4
ANSAMBL
R-G1 - U R-G1
ANSAMBL
RG1 - U RG1
ANSAMBL
R-G2 - U R-G2
ANSAMBL
RG3 - U RG3
ANSAMBL
R-M1 - U R-M1
ANSAMBL
R-ST1 - U R-ST1
ANSAMBL
R-ST2 - U R-ST2
ANSAMBL
R-ST3 - U R-ST3
ANSAMBL
R-ST4 - U R-ST4
ANSAMBL
SC1 - U SC1
ANSAMBL
SC2 - U SC2
ANSAMBL
SC3 - U SC3
ANSAMBL
SC4 - U SC4
ANSAMBL
SC5 - U SC5
ANSAMBL
SC6 - U SC6
ANSAMBL
SC7 - U SC7
ANSAMBL
SC8 - U SC8
ANSAMBL
SC9 - U SC9
ANSAMBL
SC10 - U SC10
ANSAMBL
SC11 - U SC11
ANSAMBL
SC12 - U SC12
ANSAMBL
SC14 - U SC14
ANSAMBL
SC15 - U SC15
ANSAMBL
SC16 - U SC16
ANSAMBL
SC17 - U SC17
ANSAMBL
SCARA1 - U SCARA1
ANSAMBL
SL1 - U SL1
ANSAMBL
SL2 - U SL2
ANSAMBL
SL3 - U SL3
ANSAMBL
SL4 - U SL4
ANSAMBL
SL5 - U SL5
ANSAMBL
SL6 - U SL6
ANSAMBL
SL7 - U SL7
ANSAMBL
SL9 - U SL9
ANSAMBL
SL10 - U SL10
ANSAMBL
SL11 - U SL11
ANSAMBL
ST1 - U ST1
ANSAMBL
ST2 - U ST2
ANSAMBL
ST3 - U ST3
ANSAMBL
ST4 - U ST4
ANSAMBL
ST5 - U ST5
ANSAMBL
ST6 - U ST6
ANSAMBL
ST7 - U ST7
ANSAMBL
ST8 - U ST8
ANSAMBL
ST9 - U ST9
ANSAMBL
ST10 - U ST10
ANSAMBL
ST11 - U ST11
ANSAMBL
ST12 - U ST12
ANSAMBL
ST13 - U ST13
ANSAMBL
ST14 - U ST14
ANSAMBL
ST15 - U ST15
ANSAMBL
ST16 - U ST16
ANSAMBL
ST17 - U ST17
ANSAMBL
ST18 - U ST18
ST19 - ANSAMBL ST19
U
ANSAMBL
T15 - U T15
ANSAMBL
TR1 - U TR1
ANSAMBL
TR2 - U TR2
ANSAMBL
TR3 - U TR3
ANSAMBL
TR4 - U TR4
ANSAMBL
TR5 - U TR5
ANSAMBL
TR6 - U TR6

DEBITARE PROFILE SI PLACI METALICE


Beneficiar: S.C. MERLINS BEVERAGES S.R.L.
UNITATE PRODUCTIE BAUTURI RACORITOARE
Amplasament: STR. IZVOARE, NC 63640, MUN. PIATRA NEAMT, JUD. NEAMT

PROGRAM DE CONTROL
OBIECT: UNITATE PRODUCTIE BAUTURI RACORITOARE
Nr.cr
SPECIALITATEA

Inreg.
FAZA DIN LUCRARE SUPUSA OBLIGATORIU PARTICIPANTI DOC. CERTIFICARE control
efectuat
CONTROLULUI SI ATESTARII CALITATII
B – beneficiar, PV – proces verbal
investitor PVPP – proces verbal
E – executant de prelevare probe
P – proiectant PVLA – proces verbal
G – geotehnician de lucrari ascunse
I – inspector PVRC – proces verbal
de receptie calitativa
FD – faza determinanta
FCP – fisa de
confectionare probe
PVRTL – proces verbal
de receptie la
terminare lucrari
PVRF – proces verbal
de receptie finala
REZISTENTA

1. ATINGERE COTA FUNDARE. B+E+P+G PV, PVPP


NATURA TERENULUI DE FUNDARE
2. VERIFICAREA CARACTERISTICILOR MECANICE B+E PVPP
ALE OTELURILOR
3. ARMARE FUNDATII. COFRARE FUNDATII B+E+P PVLA, PVRC
VERIFICARE POZITIE CARCASE INGLOBATE
POZITIONARE PAHARE PREFABRICATE
VERIFICARE PREMERGATOARE TURNARII BETONULUI
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
4. VERIFICAREA CARACTERISTICILOR BETONULUI PROASPATB+E FCP
(PREPARAT LA STATII DE BETOANE ATESTATE)
5. VERIFICARE ASPECT BETON DUPA DECOFRARE FUNDATII B+E PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.7)
6. VERIFICARE MONTAJ PARAPETI PREFABRICATI B+E+P PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.8)
7. VERIFICARE MONTAJ STALPI PREFABRICATI B+E+P PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.8)
8. VERIFICARE MONTAJ GRINZI PREFABRICATE B+E+P PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.8)
9. VERIFICARE MONTAJ GRINZI SI PREDALE PLANSEU +3.47m B+E+P PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.8)
10. COFRARE SI ARMARE SUPRABETONARE PLANSEU +3.47m B+E+P PVLA
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
11. MONTAJ TABLA CUTATA ACOPERIS B+E+P PVRC
12. VERIFICAREA CALITATII MONTAJULUI B+E PV
STRUCTURILOR METALICE CF. STAS 767/0-88
SI NORMATIVE C150-99, C56-85
13. RECEPTIA STRUCTURII DE REZISTENTA B+E+P PVRTL
VERIFICARE FIZICA LA TERMINAREA MONTAJULUI
Executantul trebuie sa anunte proiectantul cu cel putin doua zile inaintea datei la care urmeaza sa
faca verificarile respective. Neconvocarea in timp util a proiectantului reprezinta preluarea exclusiva de catre
executant a raspunderilor privind conformitatea executiei lucrarilor cu proiectul.
In afara punctelor obligatorii pentru verificare, proiectantul va fi solicitat prin grija executantului in
urmatoarele situatii:
 Derogari privind calitatea materialelor
 Cand certificatele de calitate a lucrarii nu corespund prevederilor din proiect
 La prereceptii si receptii
 La greutati de executie si la diferente intre proiect si executie
Executantul este obligat sa ia toate masurile tehnico-organizatorice pentru realizarea lucrarilor in
conditiile de calitate cerute prin proiect.

PROIECTANT : BENEFICIAR : CONSTRUCTOR :

S.C. PARTENER CREATIV OFFICE S.R.L. S.C. MERLINSBEVERAGES S.R.L.

VIZAT ICJ NEAMT

OBIECT: CABINA POARTA


Nr.cr

Inreg.
FAZA DIN LUCRARE SUPUSA OBLIGATORIU PARTICIPANTI DOC. CERTIFICARE control
efectuat
SPECIALITATEA
CONTROLULUI SI ATESTARII CALITATII B – beneficiar, PV – proces verbal
investitor PVPP – proces verbal
E – executant de prelevare probe
P – proiectant PVLA – proces verbal
G – geotehnician de lucrari ascunse
I – inspector PVRC – proces verbal
de receptie calitativa
FD – faza determinanta
FCP – fisa de
confectionare probe
PVRTL – proces verbal
de receptie la
terminare lucrari
PVRF – proces verbal
de receptie finala
REZISTENTA

1. ATINGERE COTA FUNDARE. B+E+P+G PV, PVPP


NATURA TERENULUI DE FUNDARE
2. VERIFICAREA CARACTERISTICILOR MECANICE B+E PVPP
ALE OTELURILOR
3. ARMARE FUNDATII. COFRARE FUNDATII B+E+P PVLA, PVRC
VERIFICARE POZITIE CARCASE INGLOBATE
VERIFICARE PREMERGATOARE TURNARII BETONULUI
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
4. VERIFICAREA CARACTERISTICILOR BETONULUI PROASPATB+E FCP
(PREPARAT LA STATII DE BETOANE ATESTATE)
5. VERIFICARE ASPECT BETON DUPA DECOFRARE FUNDATII B+E PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.7)
6. VERIFICAREA CALITATII MONTAJULUI B+E PV
STRUCTURILOR METALICE CF. STAS 767/0-88
SI NORMATIVE C150-99, C56-85
7. MONTAJ TABLA CUTATA ACOPERIS B+E+P PVRC
8. RECEPTIA STRUCTURII DE REZISTENTA B+E+P PVRTL
VERIFICARE FIZICA LA TERMINAREA MONTAJULUI
Executantul trebuie sa anunte proiectantul cu cel putin doua zile inaintea datei la care urmeaza sa
faca verificarile respective. Neconvocarea in timp util a proiectantului reprezinta preluarea exclusiva de catre
executant a raspunderilor privind conformitatea executiei lucrarilor cu proiectul.

PROIECTANT : BENEFICIAR : CONSTRUCTOR :

S.C. PARTENER CREATIV OFFICE S.R.L. S.C. MERLINSBEVERAGES S.R.L.

VIZAT ICJ NEAMT

OBIECT: CAMERA TEHNICA REZERVOARE INCENDIU SI APA TEHNOLOGICA


SPECIALITATEA

Nr.cr

Inreg.
FAZA DIN LUCRARE SUPUSA OBLIGATORIU PARTICIPANTI DOC. CERTIFICARE control
efectuat
CONTROLULUI SI ATESTARII CALITATII
B – beneficiar, PV – proces verbal
investitor PVPP – proces verbal
E – executant de prelevare probe
P – proiectant PVLA – proces verbal
G – geotehnician de lucrari ascunse
I – inspector PVRC – proces verbal
de receptie calitativa
FD – faza determinanta
FCP – fisa de
confectionare probe
PVRTL – proces verbal
de receptie la
terminare lucrari
PVRF – proces verbal
de receptie finala
REZISTENTA
1. ATINGERE COTA FUNDARE. B+E+P+G PV, PVPP
NATURA TERENULUI DE FUNDARE
2. VERIFICAREA CARACTERISTICILOR MECANICE B+E PVPP
ALE OTELURILOR
3. ARMARE FUNDATII. COFRARE FUNDATII B+E+P PVLA, PVRC
VERIFICARE POZITIE CARCASE INGLOBATE
VERIFICARE PREMERGATOARE TURNARII BETONULUI
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
4. VERIFICAREA CARACTERISTICILOR BETONULUI PROASPATB+E FCP
(PREPARAT LA STATII DE BETOANE ATESTATE)
5. VERIFICARE ASPECT BETON DUPA DECOFRARE FUNDATII B+E PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.7)
6. VERIFICAREA CALITATII MONTAJULUI B+E PV
STRUCTURILOR METALICE CF. STAS 767/0-88
SI NORMATIVE C150-99, C56-85
7. MONTAJ TABLA CUTATA ACOPERIS B+E+P PVRC
8. RECEPTIA STRUCTURII DE REZISTENTA B+E+P PVRTL
VERIFICARE FIZICA LA TERMINAREA MONTAJULUI
Executantul trebuie sa anunte proiectantul cu cel putin doua zile inaintea datei la care urmeaza sa
faca verificarile respective. Neconvocarea in timp util a proiectantului reprezinta preluarea exclusiva de catre
executant a raspunderilor privind conformitatea executiei lucrarilor cu proiectul.

PROIECTANT : BENEFICIAR : CONSTRUCTOR :

S.C. PARTENER CREATIV OFFICE S.R.L. S.C. MERLINSBEVERAGES S.R.L.

VIZAT ICJ NEAMT

OBIECT: TOTEM
Nr.cr
SPECIALITATEA

Inreg.
FAZA DIN LUCRARE SUPUSA OBLIGATORIU PARTICIPANTI DOC. CERTIFICARE control
efectuat
CONTROLULUI SI ATESTARII CALITATII
B – beneficiar, PV – proces verbal
investitor PVPP – proces verbal
E – executant de prelevare probe
P – proiectant PVLA – proces verbal
G – geotehnician de lucrari ascunse
I – inspector PVRC – proces verbal
de receptie calitativa
FD – faza determinanta
FCP – fisa de
confectionare probe
PVRTL – proces verbal
de receptie la
terminare lucrari
PVRF – proces verbal
de receptie finala
1. ATINGERE COTA FUNDARE. B+E+P+G PV, PVPP
NATURA TERENULUI DE FUNDARE
2. VERIFICAREA CARACTERISTICILOR MECANICE B+E PVPP
ALE OTELURILOR
3. ARMARE FUNDATII. COFRARE FUNDATII B+E+P PVLA, PVRC
VERIFICARE POZITIE CARCASE INGLOBATE
VERIFICARE PREMERGATOARE TURNARII BETONULUI
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
4. VERIFICAREA CARACTERISTICILOR BETONULUI PROASPATB+E FCP
(PREPARAT LA STATII DE BETOANE ATESTATE)
5. VERIFICARE ASPECT BETON DUPA DECOFRARE FUNDATII B+E PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.7)
6. COFRARE SI ARMARE ELEMENTE STRUCTURALE VERTICALE
B+E+P PVLA
SI ORIZONTALE DE CONFINARE PERETE DIN ZIDARIE
CERAMICA
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
7. RECEPTIA STRUCTURII DE REZISTENTA B+E+P PVRTL
VERIFICARE FIZICA LA TERMINAREA MONTAJULUI
Executantul trebuie sa anunte proiectantul cu cel putin doua zile inaintea datei la care urmeaza sa
faca verificarile respective. Neconvocarea in timp util a proiectantului reprezinta preluarea exclusiva de catre
executant a raspunderilor privind conformitatea executiei lucrarilor cu proiectul.

PROIECTANT : BENEFICIAR : CONSTRUCTOR :

S.C. PARTENER CREATIV OFFICE S.R.L. S.C. MERLINSBEVERAGES S.R.L.

VIZAT ICJ NEAMT

OBIECT: IMPREJMUIRE
SPECIALITATEA

Nr.cr

Inreg.
FAZA DIN LUCRARE SUPUSA OBLIGATORIU PARTICIPANTI DOC. CERTIFICARE control
efectuat
CONTROLULUI SI ATESTARII CALITATII
B – beneficiar, PV – proces verbal
investitor PVPP – proces verbal
E – executant de prelevare probe
P – proiectant PVLA – proces verbal
G – geotehnician de lucrari ascunse
I – inspector PVRC – proces verbal
de receptie calitativa
FD – faza determinanta
FCP – fisa de
confectionare probe
PVRTL – proces verbal
de receptie la
terminare lucrari
PVRF – proces verbal
de receptie finala
1. ATINGERE COTA FUNDARE. B+E+P+G PV, PVPP
NATURA TERENULUI DE FUNDARE
2. VERIFICAREA CARACTERISTICILOR MECANICE B+E PVPP
ALE OTELURILOR
3. ARMARE FUNDATII. COFRARE FUNDATII B+E+P PVLA, PVRC
VERIFICARE POZITIE CARCASE INGLOBATE
POZITIONARE PAHARE PREFABRICATE
VERIFICARE PREMERGATOARE TURNARII BETONULUI
(conf. C56/1985, caietul V, Cap.1, pct.2.2)
4. VERIFICAREA CARACTERISTICILOR BETONULUI PROASPATB+E FCP
(PREPARAT LA STATII DE BETOANE ATESTATE)
5. VERIFICARE ASPECT BETON DUPA DECOFRARE FUNDATII B+E PVRC
(conf. C56/1985, caietul V, Cap.1, pct.2.7)
6. VERIFICAREA CALITATII MONTAJULUI B+E PV
STRUCTURILOR METALICE CF. STAS 767/0-88
SI NORMATIVE C150-99, C56-85
7. MONTAJ PANOURI IMPREJMUIRE B+E+P PVRC
8. RECEPTIA STRUCTURII DE REZISTENTA B+E+P PVRTL
VERIFICARE FIZICA LA TERMINAREA MONTAJULUI
Executantul trebuie sa anunte proiectantul cu cel putin doua zile inaintea datei la care urmeaza sa
faca verificarile respective. Neconvocarea in timp util a proiectantului reprezinta preluarea exclusiva de catre
executant a raspunderilor privind conformitatea executiei lucrarilor cu proiectul.

PROIECTANT : BENEFICIAR : CONSTRUCTOR :


S.C. PARTENER CREATIV OFFICE S.R.L. S.C. MERLINSBEVERAGES S.R.L.

VIZAT ICJ NEAMT

STABILIREA CATEGORIEI DE IMPORTANTA

Categoria de importanţă a construcţiei (cf. HG 766/1997 şi Ordinul MLPTL 31/N/1995).


Coef. de
Factorul unicitate Criteriile asociate P(i)=k(n)[Σp(i)/3]
determinant
k(n)

p(i) oameni implicaţi direct în cazul unei disfuncţii ale construcţiei 4


p(ii) oameni implicaţi indirect în cazul unor disfuncţii ale construcţiei 1
1 Importanţa vitală 1 2
caracterul evolutiv al efectelor periculoase, în cazul unor disfuncţii ale
p(iii) 1
construcţiei
mărimea comunităţii care apelează la funcţiunnile construcţieişi/sau
Importanţa p(i) 1
valoarea bunurilor materiale adăpostite de construcţie
2 social-economică 1 2
p(ii) ponderea în care funcţiunile construcţiei o au în comunitatea respectivă 2
şi culturală
p(iii) natura şi importanţa funcţiilor respective 2
măsura în care realizarea şi exploatarea construcţiei intervine în
p(i) 1
perturbarea mediului natural şi a mediului construit
Implicarea
3 1 1
ecologică p(ii) gradul de influenţă nefavorabilă asupra mediului natural şi construit 2
p(iii) rolul activ în protejarea/refacerea mediului natural şi construit 1
p(i) durata de utilizate preconizată 6
Necesitatea luării
măsura în care performanţele alcătuirilor constructive depind de
în considerare a p(ii) 1
4 1 cunoaşterea evoluţiei acţiunilor (solicitărilor) pe durata de utilizare 3
duratei de utilizare
(existenţa) măsura în care performanţele funcţionale depind de evoluţia cerinţelor pe
p(iii) 2
durata de utilizare
măsura în care asigurarea soluţiilor constructive este dependentă de
p(i) 2
condiţiile locale de teren şi de mediu
Necesitatea
măsura în care condiţiile locale de teren şi de mediu evoluează
adaptării la p(ii) 1
5 1 defavorabil în timp 2
condiţiile locale de
teren şi de mediu măsura în care condiţiile locale de teren şi de mediu determină activităţi/
p(iii) măsuri deosebite pentru exploatarea construcţiei pe durata de existenţă a 2
acesteia
p(i) ponderea volumului de muncă şi de materiale înglobate 2
Volumul de muncă volumul şi complexitatea activităţilor necesare pentru menţinerea
p(ii) 1
6 şi de materiale 1 performanţelor construcţiei pe durata de existenţă a acesteia; 1
necesare
activităţi deosebite în exploatarea construcţiei impuse de funcţiunile
p(iii) 1
acesteia
TOTAL 11

Construcţia se încadrează în categoria de importanţă “C”(importanţă normală).

STABILIREA CATEGORIEI DE IMPORTANTA


Categoria de importanţă a construcţiei (cf. HG 766/1997 şi Ordinul MLPTL 31/N/1995).
Coef. de
Factorul unicitate Criteriile asociate P(i)=k(n)[Σp(i)/3]
determinant
k(n)

1 Importanţa vitală 1 p(i) oameni implicaţi direct în cazul unei disfuncţii ale construcţiei 1 1
p(ii) oameni implicaţi indirect în cazul unor disfuncţii ale construcţiei 0
caracterul evolutiv al efectelor periculoase, în cazul unor disfuncţii ale
p(iii) 2
construcţiei
mărimea comunităţii care apelează la funcţiunnile construcţieişi/sau
Importanţa p(i) 1
valoarea bunurilor materiale adăpostite de construcţie
2 social-economică 1 1
p(ii) ponderea în care funcţiunile construcţiei o au în comunitatea respectivă 1
şi culturală
p(iii) natura şi importanţa funcţiilor respective 0
măsura în care realizarea şi exploatarea construcţiei intervine în
p(i) 1
perturbarea mediului natural şi a mediului construit
Implicarea
3 1 1
ecologică p(ii) gradul de influenţă nefavorabilă asupra mediului natural şi construit 2
p(iii) rolul activ în protejarea/refacerea mediului natural şi construit 1
p(i) durata de utilizate preconizată 2
Necesitatea luării
măsura în care performanţele alcătuirilor constructive depind de
în considerare a p(ii) 1
4 1 cunoaşterea evoluţiei acţiunilor (solicitărilor) pe durata de utilizare 1
duratei de utilizare
(existenţa) măsura în care performanţele funcţionale depind de evoluţia cerinţelor pe
p(iii) 1
durata de utilizare
măsura în care asigurarea soluţiilor constructive este dependentă de
p(i) 1
condiţiile locale de teren şi de mediu
Necesitatea
măsura în care condiţiile locale de teren şi de mediu evoluează
adaptării la p(ii) 1
5 1 defavorabil în timp 1
condiţiile locale de
teren şi de mediu măsura în care condiţiile locale de teren şi de mediu determină activităţi/
p(iii) măsuri deosebite pentru exploatarea construcţiei pe durata de existenţă a 1
acesteia
p(i) ponderea volumului de muncă şi de materiale înglobate 1
Volumul de muncă volumul şi complexitatea activităţilor necesare pentru menţinerea
p(ii) 1
6 şi de materiale 1 performanţelor construcţiei pe durata de existenţă a acesteia; 1
necesare
activităţi deosebite în exploatarea construcţiei impuse de funcţiunile
p(iii) 0
acesteia
TOTAL 6

Construcţia se încadrează în categoria de importanţă “C” (importanţă normală).

MEMORIU TEHNIC DE REZISTENTA

5. GENERALITATI:
Caracteristici ale obiectului UNITATE DE PRODUCTIE BAUTURI RACORITOARE:
- 2 deschiderI avand 24.00m;
- 9 travei avand 12.00m;
- regim de inaltime P+Epartial;
- inaltime la atic +8.20m;
- sistem structural din cadre cu stalpi (65x65cm) si grinzi (sectiune variabila) din beton
armat prefabricat;
- planseu intemediar partial din zona (A-A2)(4-5) cu grinzi SI fasii cu goluri din beton
armat prefabricat si suprabetonare din beton armat monolit;
- cota de nivel a pardoselii finite de la parter este +0.00m;
- grinzile si panele prefabricare din beton armat precomprimat au fost proiectate sa sustina
o invelitoare din tabla trapezoidala autoportanta tip MBS153 cu gr.1.00mm peste care se
dispune vata minerala si membrana hidroizolatoare tip Sikaplan 15G;
- dimensiuni in plan ale structurii 108.65x48.65m;
- fundatia a fost proiectata in varianta fundatii izolate din beton armat monolit cu pahare
din beton prefabricat avand dimensiunile in plan in functie de solicitari;
Conform S.T.A.S. 6054-77, adâncimea minimă de îngheţ este de –0.90 m de la CTN.
Conform normativului NP112-2014, fundarea se va realiza cu o încastrare minimă de 20cm in
stratul bun de fundare.

Caracteristici ale obiectului CABINA POARTA:


- 2 deschiderI avand 5.00m, respectiv 2.00m si 2 travei avand 3.00m, respectiv 4.50m;
- regim de inaltime P;
- inaltime la atic +4.50m;
- sistem structural din cadre cu stalpi si grinzi din profile de otel laminate la cald S235JR,
teava patrata si teava rectangulara diverse sectiuni;
- cabina poarta va avea un sistem de fundare cu grinzi contiune cu talpa si elevatie din
beton armat;
- pentru a sustine invelitoare din tabla cutata H=153mm, cu grosimea de 1.0mm s-a
propus dispunerea unor pane metalice cu profil teava patrata S235JR;
- dimensiuni in plan structura 7.12x7.62m.

Caracteristici ale obiectului REZERVOARE INCENDIU SI STATIE DE POMPARE:


- obiectul consta in doua rezervoare metalice supraterane si un corp de cladire comun
acestora functionand ca statie de pompare supraterana;
- rezervorul pentru rezerva apa hidranti are dimensiunile Dn=8.00m si H=10.60m;
- rezervorul pentru rezerva apa sanitara si tehnologica Dn=6.60m si H=8.50m;
- rezervoarele se vor funda pe radiere din beton armat conform pieselor desenate din
proiecte dedicate furnizare de producatorul acestora;
- corpul de cladire cu functiuniea „statie de pompare supraterana” are dimensiunile in
plan 5.00x6.12m, are inaltimea la atic de 4.00m;
- corpul „statiei de pompare supraterana” se va realiza cu supratructura din cadre cu stalpi
si europrofile tip IPE si HEA , calitate S235JR;
- cota de nivel a pardoselii finisate de la parter este de +0.00m;
- invelitoarea corpului „statie de pompare” se va realiza cu tabla cutata autoportanta
H=153mm, co grosimea de 1.00mm;

Caracteristici ale obiectului IMPREJMUIRE:


IMPREJMUIRE TIP A – plasa profilata zincata, transparenta, Hmax = 2,00m:
- Fundatii izolate sub stalpi alcatuite din beton simplu C8/10 avand dimensiunile in plan
50x50cm si adancime de fundare 1.00m;
- Stalpi metalici cu sectiune rectangulara 60x40x4, incastrati 50cm in fundatii izolate, dispusi
din 2.50m in 2.50m;
Caracteristici ale obiectului TOTEM ACCES:
- Fundatie continua de tip talpa si elevatie din beton armat C16/20 avand dimensiunile in plan
avand adancimea de fundare 1.50m;
- Suprastructura alcatuita din zidarie de caramida tip GVP confinata cu samburi si centuri din
beton armat avand inaltimea de 2.39m si lungimea de 5.50m.

6. PARAMETRI DE CALCUL SPECIFICI AMPLASAMENTULUI:


 pentru încărcări seismice, conform P100-1/2013 construcţia este amplasata in zona cu
ag=0,20g şi perioada de colţ Tc=0,7s având clasa de importanţă III cu γI= 1.0;

 pentru încărcări date de zăpadă , S0k=2 KN/m2 , conform CR 1-1-3-2012, pentru o perioadă
de revenire de 50 de ani;

 Pentru încărcări date de vant, s-au folosit prevederile normativului CR 1-1-4/2012,


amplasamentul fiind in zona eoliana avand presiunea de referinta 0.60 kN/mp;

 conform C107/6-2002, amplasamentul se incadreaza in zona climatica II, avand


temperatura exterioara de calcul Te=-180C;

 La nivelul inferior al sapaturii terenul este format din terenul este format din praf argilos,
loessoid, uscat, plastic vartos, tare, macroporic, cu compresibilitate mare, sensibil la
umezire grupa A ce asigura preluarea unei presiuni conventionale de baza de minim
pconv=150kPa.

7. CARACTERISTICI ALE STRUCTURII DE REZISTENTA:

UNITATE DE PRODUCTIE BAUTURI RACORITOARE

Infrastructura
Ţinând cont de regimul de înălţime al imobilului, caracteristicile şi conformaţia terenului, s-
a adoptat soluţia de fundare de tip fundatii izolate tip talpa monolita (C20/25) si pahar prefabricat
(C25/30) din beton armat. Talpile au dimensiunile in plan variabile, in functie de solicitari dispuse
pe un strat din beton de egalizare C8/10 avand grosimea minima de 10cm.
Detalii privind cofrajul şi armarea fundatiilor sunt prezentate în planşa R1 si plansele F1 ..
F9 pentru detaliile fundatiilor.

Suprastructura
Structura propusa este alcatuita din 2 deschideri avand 25.00m, precum si 9 travei avand
12.00m.
Structura de rezistenta a constructiei este realizata din cadre cu stalpi prefabricati 65x65cm
(C30/37), grinzi prefabricate din beton precomprimat (C50/60) cu 12m deschidere avand inaltimea
de 120cm si latime variabila de la 54cm la 18cm, precum si pane din beton armat precomprimat
(C50/60) cu 24m deschidere avand inaltimea de 110cm si latime variabila de la 54cm la 18cm.
Planseul intermediar partial delimitat de axele (A-A2)(4-5) este alcatuit din grinzi din beton
armat prefabricat (C40/50) 60x55cm, fasii cu goluri din beton armat precomprimat (C50/60) avand
inaltimea de 32cm, si o suprabetonare cu grosimea de 8cm (C30/37).
Ancadramentele usilor si a ferestrelor sunt propuse din ansamble sudate din teava patrata
SHS100x5mm solidarizate de structura din beton armat cu ancore tip conexpand M16x165mm.
Invelitoarea tip terasa necirculabila va fi sustinuta cu fasii de tabla trapezoidala autoportanta
H=153mm si grosime 1.00mm. Fasiile se vor procura si se vor monta intocmai la lungimile si
pozitiile propuse in plansa dedicata. Nu se va accepta suprapunerea tablei in alta varianta fara
consultarea in prealabil a proiectantului.
La cota +0.00 se va realiza o pardoseala industriala elicopterizata cu grosimea de 20cm.
CABINA POARTA
Infrastructura
Ţinând cont de regimul de înălţime al imobilului, caracteristicile şi conformaţia terenului,
tipul de structura adoptat, s-a adoptat soluţia de fundare in varianta cu grinzi de fundare continue
sub stalpii metalici ai cabinei poarta.
Grinzile de fundare sunt alcatuite din talpa 70x40cm si elevatie 40x60cm din beton armat
C16/20.
Pentru detalii privind infrastructura se vor consulta cR1 .. cR7.

Suprastructura
Structura propusă are 2 deschideri avand 2.00m, respectiv 5.00m, si 2 travei avand 2.00m,
respectiv 4.50m.
Structura este realizata integral din metal, elementul principal de rezistenta constituindu-l
cadrul transversal format din stalpi si rigle metalice.
Stalpii sunt alcatuiti din profile de tip teava patrata SHS120x6mm, in timp ce riglele sunt
realizate din profile de tip teava patrata SHS120x6mm.
Stalpii sunt luati in calcul ca si articulati, ancorarea de sistematizarea din incinta realizandu-
se prin intermediul ancorelor mecanice tip conexpand M16x165mm.
Imbinarile din suprastructura sunt realizate cu sudura de colt avand inaltimea 0.7 din tmin.
S-au prevazut contravantuiri orizontale in planul invelitorii alcatuite din tije M16, calitate
S235 puse la pozitie si tensionate cu mansoane de intindere prefabricate tip FISCHER M16.

REZERVOARE INCENDIU si STATIE DE POMPARE


Infrastructura
Rezervoarele pentru rezerva apa antiincendiu se vor executa conform pieselor scrise si
desenate din proiectele furnizate de producator.
Pentru „corpul statie de pompare”, tinând cont de regimul de înălţime al imobilului,
caracteristicile şi conformaţia terenului, s-a adoptat soluţia de fundare de tip fundatii izolate sub
stalpi cu grinzi de echilibrare.
Fundatiile izolate sunt alcatuite din beton armat C20/25 si au dimensiunile in plan de
1.20x1.20m.
Grinzile de fundare sunt armate longitudinal superior si inferior cu cate 3 bare 14mm
Bst500S si transversal cu etrieri 8mm Bst500S spatiati la 20cm.
La cota +0.00m se va executa o pardoseala din beton sclivisit C20/25 cu grosimea de 20cm
armata cu 2 randuri de plasa sudata SPPB 8x100x100mm.

Suprastructura
Sistemul structural al obiectului este propus din cadre cu stalpi si grinzi otel S235JR avand
profile tip IPE, HEA.
Structura este contravantuita in planul invelitorii si in plan vertical pentru a limita
deplasarile, in special pe directiile rezervoarelor adiacente.
Invelitoarea corpului „statie de pompare” se va realiza cu tabla cutata autoportanta
H=153mm cu grosimea de 1.00mm dispusa direct pe grinzile din otel de peste parter.
Atat infrastructura cat si suprastructura corpului „statie de pompare” se va realiza cu rost de
tasare si seismic fata de rezervoarele adiacente.

IMPREJMUIRE
IMPREJMUIRE TIP A – plasa profilata zincata, transparenta, Hmax = 2,00m:
- Fundatii izolate sub stalpi alcatuite din beton simplu C8/10 avand dimensiunile in plan
50x50cm si adancime de fundare 1.00m;
- Stalpi metalici cu sectiune rectangulara 60x40x4, incastrati 50cm in fundatii izolate, dispusi
din 2.50m in 2.50m;
Conform S.T.A.S. 6054-77, adâncimea minimă de îngheţ este de –0.90 m de la CTN.
Conform normativului NP112-2014, fundarea se va realiza cu o încastrare minimă de 20cm in
stratul bun de fundare.

TOTEM ACCES
Infrastructura
Pentru sistemul de fundare a totemului din zona accesului s-a optat pentru solutia unei
fundatii continue cu talpa si elevatie din beton armat C16/20, avand adancimea de fundare de
1.50m.
Din talpa de fundare se vor lasa mustati de ancorare a samburilor din suprastructura.

Suprastructura
Structura totemului este alcatuita din zidarie ceramica tip GVP avand grosimea de 30cm,
tencuita pe ambele fete.
Zidaria de caramida va fi confinata cu samburi si centuri din beton armat avand
dimensiunile sectionale 30x30cm.
Date despre calculul structurii de rezistenţă
Calculul structurii la încărcări gravitaţionale şi la acţiuni seismice s-a efectuat conform
CR0-2012, CR113-2012, CR114-2012, P100-1/2013, CR 2-1-1.1/2013.
Verificările şi alcătuirile secţiunilor elementelor structurale din beton armat s-au efectuat
conform SR EN 1992-1-1 “Proiectarea structurilor din beton”.
Infrastructura clădirii s-a proiectat in funcţie de natura terenului de fundare conform
normativului NP112-2014.
Tinand cont de caracterul sensibil la umezire a terenului de fundare s-au luat in calcul
prevederile normativului NP125-2010.

Tratare anticoroziva a structurii metalice


Conform GP121-2013 structura este amplasata intr-o clasa de corozivitate atmosferica C3.
Elementele de constructie au sectiunea inchisa etans, compuse prin sudare, si se vor vopsi
in interior complet, ultimele capace fiind vopsite in prealabil, iar zona influentata de sudura va fi
acoperita pe muchii cu un grund rezistent la sudura.
Protectia anticoroziva se va executa astfel:
 curatarea prin sablare sau cu peria de sarma pana la obtinerea luciului metalic;
 desprafuirea, degresarea si uscarea;
 aplicarea a 2 straturi de grund – 45 microni;
 aplicarea unui strat de email – 45 microni (in fabrica);
 aplicarea unui strat de email – 45 microni (in santier, cu rol de remediere);
Sistemul se va alege conform GP035-98, Tabel 1, dintre pozitiile 17-20 si din GP111-2004.

Suduri
 Debitarea si punerea in opera a tuturor elementelor metalice se va face numai dupa
realizarea unui singur ansamblu si executia unui premontaj pentru verificare.
 Imbinarile sudate se vor realiza prin sudura electrica pe intreg perimetrul de contact,
grosimea cordonului de sudura fiind egala cu 0.7 din grosimea celei mai subtiri piese ce se
sudeaza.
 Imbinarile sudate se incadreaza in nivelul de acceptare C, pentru elementele principale si
secundare, conform normativ C150-99.
 Unitatea care executa imbinari sudate are obligatia intocmirii tehnologiei de confectionare a
constructiei si va introduce in fabricatie materiale de sudare corespunzatoare unor proceduri
de sudare calificate pentru nivelul C, prevazut in proiect.
 Clasa de executie a structurii conform STAS767-88 este "B";

8. EXECUTAREA LUCRARILOR PE TIMP FRIGUROS:

Pe timp friguros lucrarile se vor executa in conditii prevazute in actele normative in vigoare
printre care:
- Normativ pentru executarea lucrarilor de beton si beton armat
NE 012-1 2007, NE012-2 2010;
- Normativ pentru executarea lucrarilor pe timp friguros C16-84.

9. INSTRUCTIUNI TEHNICE PENTRU URMARIREA IN TIMP A CONSTRUCTIILOR :


Acest program vizează următoarele capitole majore:
 urmărirea tasărilor în perioada de execuţie a lucrărilor şi în perioada de exploatare;
 urmărirea comportării în timp a construcţiei:
- deplasări orizontale, verticale sau înclinări
- desprinderi de trotuare, socluri, apariţia de rosturi sau crăpături
- deformaţii vizibile: verticale, orizontale sau rotiri
- etanşeitatea izolaţiei fonice sau hidrofuge
- umezirea pereţilor, infiltraţii de apă, lichefieri ale pământului după cutremure
- apariţia condensului, ciupercilor, mucegaiului
- înfundarea scurgerilor la burlane, jgheaburi, canale;
Beneficiarul va face relevee, schite si va inmana de urgenta un raport proiectantului, iar in
cazuri deoebite va lua masuri imediate de sprijiniri locale, descarcari de sarcini, opriri de activitati,
pentru evitarea oricarui accident sau accident tehnic care poate duce la pierderi materiale sau de
vieti omenesti.
Orice modificare sau consolidare, precum si schimbarea ipotezelor de incarcare la care au
fost calculate elementele de rezistenta ale structurii, se va face cu acordul scris al proiectantului sau
in urma unei expertize tehnice facute de un expert autorizat de catre MLPAT.

MASURI SPECIALE DE URMARIRE IN TIMP:


Tinand cont de conditiile meteorologice din ce in ce mai nefavorabile in ultima vreme,
recomandam ca in cazul unor caderi masive si repetate de zapada, pe acoperisul cladirii sa se
efecuteze determinari ale greutatii acesteia. Propunem ca aceste determinari sa se efectueze pe zone
avand dimensiunile 50x50cm. In cazul in care greutatea specifica depaseste 120kg/mp, sau in
situatia in care grosimea stratului de zapada proaspata (fara depuneri anterioare) depaseste 60cm se
vor lua masuri de evacuare a zapezii de pe acoperis. Materialul indepartat se va evacua in mod
direct de pe acoperis, neadmitandu-se depozitarea acesteia pe acoperis.

10. MASURI DE PROTECTIE A MUNCII:


La executarea lucrarilor se vor respecta toate masurile de protectie a muncii prevazute in
legislatia in vigoare in special din: „Regulamentul privind protectia si igiena muncii in constructii”
editia 1993; Legea Protectiei Muncii Nr. 90-1996; „Norme generale de protectie a muncii” editia
1996; precum si „Norme specifice de protectie a muncii pentru diferite categorii de lucrari”.
Lucrarile se vor executa pe baza proiectului de organizare si a fiselor tehnologice elaborate
de tehnologul executant, in care se vor detalia toate masurile de protectie a muncii. Se va verifica
insusirea fiselor tehnologice de catre
intreg personalul din executie. Dintre masurile speciale ce trebuie avute in vedere se mentioneaza:
- Zonele de lucru periculoase vor fi marcare cu placaje si inscriptii;
- Se vor face amenajari speciale (podine de lucru, parapeti, dispozitive);
- Toate dispozitivele, mecanismele si utilajele vor fi verificate in conformitate cu normele
in vigoare;
- Asigurarea cu forta de munca calificata si care sa cunoasca masurile de protectie a
muncii in vigoare din „Regulamentul privind protectia si igiena in constructii” editia
1993, cap.1-41.
Se atrage atentia asupra faptului ca masurile de protectie a muncii prezentate nu au caracter
limitativ, constructorul avand obligatia de a lua toate masurile necesare pentru prevenirea
eventualelor accidente de munca (masuri prevazute si in „Norme specifice de securitate a muncii
pentru diferite categorii de lucrari”.

11. RECOMANDARI:
Firma de executie are obligatia de a studia amanuntit atat plansele desenate cat si piesele
scrise: memorii pe specialitati, caiete de sarcini, antemasuratori, liste de cantitati. Eventualele
obiectiuni se vor aduce la cunostinta beneficiarului si a proiectantului inainte de ofertare.
Toate lucrările trebuie dirijate şi îndrumate de personal calificat şi atestat în condiţiile legii
(responsabil cu execuţia, atestat MLPTL).
In executie se vor respecta normele tehnice de protectie a muncii specifice fiecarei categorii
de lucrari.

Orice modificare la actualul proiect se va face cu acordul proiectantului initial. Modificarile


aduse fara consultarea proiectantului il absolva pe acesta de orice responsabilitate.
Execuţia proiectului se va face conform proiectului faza PTH , DDE întocmit de către
proiectant autorizat şi vizat de către verificator atestat MLPAT.

Potrebbero piacerti anche