Sei sulla pagina 1di 3

Service Bulletin Priority III

Power Technique Service

1. General information

Title Size II Check valve update

Publication Number : SB WUX0023


Priority : III
Applicable to : All CAT_C15; CAT_C18; DECE_QSZ13 machine
PGC : 433
Responsible person : Lihua Luo

2. Document overview

This document describes the following:


1. General information ........................................................................................................................................................ 1
2. Document overview ........................................................................................................................................................ 1
3. Revision History.............................................................................................................................................................. 1
4. Reason for this bulletin ................................................................................................................................................... 2
5. Description ..................................................................................................................................................................... 2
6. Application ...................................................................................................................................................................... 2
7. Required parts ................................................................................................................................................................ 2
8. Planning ordering parts at distribution centre ................................................................................................................. 2
9. Reimbursement criteria .................................................................................................................................................. 2
10. Reporting ........................................................................................................................................................................ 2
11. Safety precautions .......................................................................................................................................................... 2

3. Revision History
REVISION DATE REVISION SUMMARY AUTHOR
0001 04/22/2019 Size II Check valve update Lihua Luo

This is an Atlas Copco internal document. It is not to be shared with distributors, dealers or customers!
04/22/2019 Page 1 of 3
4. Reason for this bulletin

Fast respond ability of Drill air unit result frequently open and close of check valve during certain application, which could
increase the risk of check valve piston/spring failure, and may also cause compressor oil back flash to air filter when
machine shutting down.

5. Description

New check valve housing released aim to enhance part strength, reduce failure risk

6. Application

XRVS1100; Y1300; X1300; Y1260; Y1200; OEM XRHO1550; OTM XRXS1210; OTM XRHS1500; OTM XRHO1550
XRYS1150; XRXS1210; XRVS1300; XRVS1350; XRXS1275; XRXS1240; XRVS617; XRVS647; XRXS567; XRXS607
PKD-BG; BG CS 2.081; BG CS 2.176

7. Required parts

No. Prat number Name Quantity


1 1092 3773 00 Valve Housing 1
2 1092 3850 00 Insert 1
3 2253 9671 01 Valve 1
4 1638 3693 00 Spring Compression 1
5 1626 0929 01 Valve Base 1

8. Planning ordering parts at distribution centre

RDC and PTD responsible for necessary parts mentioned above.

9. Reimbursement criteria

Within warranty period: Standard warranty procedure & conditions


Out of warranty period: No coverage

10. Reporting

To be reported via standard warranty procedure.

Use Claim Type “Machine Campaign”


Select APE-SB_WUX_0023.... Under chapter “Policy & Coverage

11. Safety precautions

The operator must employ safe working practices and observe all related local work safety requirements and regulations.
• Maintenance must only be performed by authorized and trained personnel.
• Before starting any work on the equipment, stop the equipment, switch off the voltage, and press the emergency
button. In addition, the power isolating switch must be opened and locked.
• Refer to the Instruction book and/or workshop manual for any additional safety precautions
• Disconnect any remote start controller
• A ‘Work in progress; do not start’ warning sign shall be attached to the starting equipment.
• All maintenance work shall only be undertaken when the equipment has cooled down.
• Effectively isolate the machine from all sources of pressure and / or electrical power and relieve the entire system of
pressure.

This is an Atlas Copco internal document. It is not to be shared with distributors, dealers or customers!
04/22/2019 Page 2 of 3
• Use only the correct tools for maintenance and repair work.
• Observe cleanliness during maintenance and repair. Cover parts and exposed openings.
• Make sure that no items are left behind in or on the equipment.
• All regulating and safety devices shall be maintained to ensure correct functionality.
They will not be put out of service.
• Always wear personal protective equipment (Work clothing, safety shoes, safety goggles, ear protection, safety
gloves,…)

This is an Atlas Copco internal document. It is not to be shared with distributors, dealers or customers!
04/22/2019 Page 3 of 3