Sei sulla pagina 1di 5

STB5100 INPUTS WIRING DIAGRAM

E-STOP & Probe touch plate


+5V XP XD YP YD ZP ZD +5V AP AD BP BD EN

Power Supply 2
12-24VDC Current > 0.5A

12-24VDC
L N V- V+ V+ V- FWD AVI GND PWM COM I1 I2 I3 I4 I5 O1 O2 O3 O4

VAC~
E-Stop Tool
Probe touch plate
N/C:Normally Closed Contact N/C
STB5100 INPUTS WIRING DIAGRAM
LIMIT & HOME SWITCH
+5V XP XD YP YD ZP ZD +5V AP AD BP BD EN

Power Supply 2
12-24VDC Current > 0.5A

12-24VDC
L N V- V+ V+ V- FWD AVI GND PWM COM I1 I2 I3 I4 I5 O1 O2 O3 O4

Z+ LIM Z- LIM Z HOME

NC NC NC
VAC~ COM
NO
COM
NO
COM
NO

Micro Switch Y+ LIM Y-LIM Y HOME


NC
COM NC NC NC
COM COM COM
NO
NO NO NO

NO :Normally Open Contact


NC: Normally Closed Contact X+ LIM X- LIM X HOME

COM: Electrical common COM


NC
COM
NC
COM
NC

NO NO NO
STB5100 INPUTS WIRING DIAGRAM
LIMIT & HOME NPN SENSOR
+5V XP XD YP YD ZP ZD +5V AP AD BP BD EN

Black
Brown
NPN
Blue Sensor

Power Supply 2 Black wire: signal wire


Brown wire: Sensor power supply +
12-24VDC Current > 0.5A Blue wire: Sensor power supply -, Common
12-24VDC
L N V- V+ V+ V- FWD AVI GND PWM COM I1 I2 I3 I4 I5 O1 O2 O3 O4

VAC~ Z+ LIM Z- LIM Z HOME


Black Black Black
Brown
NPN Brown
NPN Brown
NPN
Blue Sensor Blue Sensor Blue Sensor

Y+ LIM Y- LIM Y HOME


Black Black Black
Brown
NPN Brown
NPN Brown
NPN
Blue Sensor Blue Sensor Blue Sensor

X+ LIM X- LIM X HOME


Black Black Black
Brown
NPN Brown
NPN Brown
NPN
Blue Sensor Blue Sensor Blue Sensor

V+
STB5100 OUTPUTS WIRING DIAGRAM
Inverter connection

+5V XP XD YP YD ZP ZD +5V AP AD BP BD EN

Power Supply 2
12-24VDC Current > 0.5A

12-24VDC
L N V- V+ V+ V- FWD AVI GND PWM COM I1 I2 I3 I4 I5 O1 O2 O3 O4

VAC~ U
VAC~

R
V

Spindle motor
S
T W
Code M3, the spindle rotates forward
and the M5 spindle stops.

VI
VFD
GND

FWD
COM
STB5100 OUTPUTS WIRING DIAGRAM
Output Interfac Control Relay

+5V XP XD YP YD ZP ZD +5V AP AD BP BD EN

Power Supply 2
12-24VDC Current > 0.5A

12-24VDC
L N V- V+ V+ V- FWD AVI GND PWM COM I1 I2 I3 I4 I5 O1 O2 O3 O4

VAC~

Diode Diode Diode Diode

V+
RELAY RELAY RELAY RELAY
12&24V Coil 12&24V Coil 12&24V Coil 12&24V Coil

POWER POWER POWER POWER

LOAD LOAD LOAD LOAD

V+

Code M3 opens output O1, M5 closes output


Code M4 opens output O2, M5 closes output
Code M7 opens output O3, M9 closes output
Code M8 opens output O4, M9 closes output