Sei sulla pagina 1di 8

Construction, Completion, Furnishing, and Maintenance for

Kuwait International Airport New Passenger Terminal II


SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

SIDE PLATE- N43S-M8-1 DATE - 07-08-2019

IMAGE-1

1 & 2. Found Rebar to plate Weld size not as per drawing.

IMAGE-2

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

SIDE PLATE- W43S-H3-1

IMAGE-3

3.Found slag on exist along the Rebar to plate weld.

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

W-43S-N15-1-SIDE PLATE

IMAGE-4

4.Found cluster porosity on exist along the rebar to plate weld.

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

W-43S-F8-2-SIDE PLATE

IMAGE-5

5. Found cluster porosity on exist along the rebar to plate weld.6. Found under fill on the
weld.

IMAGE-6

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

N-43S-H7-3-SIDE PLATE

IMAGE-7

7. Found cluster porosity on exist along the rebar to plate weld.

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

IMAGE-7

8. Found cluster porosity and slag on exist along the rebar to plate weld.

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

IMAGE-9

9. Found under fill and slag on exist along the rebar to plate weld.

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X


Construction, Completion, Furnishing, and Maintenance for
Kuwait International Airport New Passenger Terminal II
SPA/214

VISUAL INSPECTION OF NETA WORKSHOP ACTIVITY

IMAGE-10

10 &11. Found cluster porosity and not as per drawing on exist along the rebar to plate
weld.

IMAGE-11

REMARKS
Refer to the comments on following pages visual inspection of / Side Plate by NETA CELIK
CONTRACTOR’S QC REPRESENTATIVE DATE:
Name and Signature: J.RAMKUMAR 07.08.2019

Document No: LKW-QAC-CHL-00000X