Sei sulla pagina 1di 1

"WELDGRP.

xls" Program
Version 2.1

ECCENTRIC LOADS ON VERTICAL PARALLEL WELD GROUPS


Based on the Instantaneous Center of Rotation Method and Alternate Method 2
Using Table XIX from AISC 9th Ed. Manual (ASD) - page 4-75
Job Name: HOLCIM JETTY EXTENSION PROJECT Subject: Check for Welding of Bracket
Job Number: Originator: Priodeep Checker:
Pv=2.5 k
Input Data: aL=3 q =0

Vertical Weld Length = 1.500 in. P=Pv


Spacing of Welds = 3.000 in.
Weld Size, w = 3/16 in. = 3 (1/16's) L=
Vertical Load, Pv = 2.50 kips 1.500 C.G. Ph=0
Horizontal Load, Ph = 0.00 kips
Dist. from Pv to C.G. = 3.000 in.
Use Special Case? No (kL)/2 (kL)/2
kL= 3
Nomenclature:

10MM THICK WELD


Pv
P = Pv = C*C1*D*L (for vertical load only) q
P = allowable load on eccentric weld group (kips) aL
C = coefficient interpolated from Table XIX P
C1 = coefficient for electrode, use 1.0 for E70XX
D = number of 1/16's of an inch (weld size) L
L = vertical weld length Ph

eq. spaces
Special Case (out of plane) (Use C values for k=0)
Results:
(Note: AISC Alternate Method 2 is not used for P=Pv)
L= 1.500 in. L = vertical weld length
kL = 3.000 in. kL = spacing of vertical welds
aL = 3.000 in. aL = dist. from Pv to C.G.
a= 2.000 a = (aL)/L
k= 2.000 k = (kL)/L
C1 = 1.0 C1 = 1.0 for E70XX electrode
C= 0.642 (interpolated from Table XIX, page 4-75)
P= 2.50 kips P = SQRT(Pv^2+Ph^2)
Angle q = 0.000 deg. q = 90-(ATAN(Pv/Ph))
Co = N.A. Co = C (from AISC Table XIX, page 4-75)
C(max) = N.A. C(max) = 0.928*(2)
A= N.A. A = C(max)/Co >= 1.0
Ca/Co = N.A. Ca/Co = A/(SINq+A*COSq) >= 1.0
Ca = N.A. Ca = (Ca/Co)*Co
D(req'd) = 2.596 1/16's D(req'd) = P/(C*C1*L)
L(req'd) = 1.298 in. L(req'd) = P/(C*C1*D)

Weld is adequate!
D(req'd) = 2.596 <= 3 (1/16's)
L(req'd) = 1.298 <= 1.5 in.

1 of 1 11/16/2019 1:07 PM