Catalyst ................................V66V55
DESCRIPTION SPECIFICATIONS
CHARACTERISTICS (cont.)
POLANE SOLAR REFLECTIVE 2K General: Substrate should be free of grease,
Urethene Enamel is a 2-package Air Drying (2.0 mils DFT, 77°F, 50% RH):
To Touch 30 minutes oil, dirt, fingerprints, drawing compounds, any
polyurethane heat reflective coating for contamination, and surface passivation
exterior use on heat sensitive substrates. Tack Free 1 hour
To Handle 2 hours treatments to ensure optimum adhesion and
coating performance properties. Consult
Advantages: To Recoat 90 minutes
Metal Preparation Brochure CC-T1 for
• Meets 3.5 lbs./gal VOC restrictions. additional details.
Do not exceed the heat distortion
• Protects heat sensitive substrates.
temperature of the substrate.
• Excellent color and gloss retention. Aluminum: If untreated, prime with Industrial
• Passes AAMA 613 Wash Primer, P60G2, or Kem Aqua® Wash
Baking Schedule:
• Mar, abrasion, and chemical resistance Flash off time 20 minutes
Primer, E61G520.
• Hap’s free 40 minutes at 140°F Aluminum: A proprietary chrome phosphate
• Lead and chromate free.
treatment is required.
Flash Point: 80°F Pensky-Martin CC
*VOC compliance limits vary from state to Aluminum: A minimum of a 5-stage chrome
state; please consult local Air Quality Mixing Ratio: phosphate metal treatment, or equivalent, is
rules and regulations. 3 parts Part A required for good adhesion and optimum
1 part V66V55 coating performance properties.
.5 part R6K18 Primer, E61G520.
May be applied by: Product Limitations: Thoroughly review product label for safety
Conventional Spray IR ovens of any type are not and cautions prior to using this product.
Airless Spray recommended. Use convection and A Material Safety Data Sheet is available
Air Assisted Airless forced air ovens only. from your local Sherwin-Williams facility.
Electrostatic Spray Please direct any questions or comments
HVLP These products reflect IR energy and to your local Sherwin-Williams facility.
Cannot be blended with other
Conventional Spray: polyurethane systems or phoenix Catalyst CONTAINS ISOCYANATES.
Air Pressure............................20-40 psi colorants. Colorants will affect infrared People who have chronic (long-term) lung
Fluid Pressure ..........................5-20 psi reflective character of coating. or breathing problems or have had a
Cap/Tip..............................As Required reaction to isocyanates, must not be in the
Reducer…..Ready to spray as catalyzed area where this product is being applied.
Performance Tests AAMA 614-05 Where overspray is present, a positive
Airless Spray: pressure air-supplied respirator should be
Pressure ................................. 1500 psi Substrate: Rigid PVC worn. If unavailable, a properly fitted
Impact Resistance, Direct .................. Pass organic vapor/particulate respirator may be
Tip ...................................... as required
Water Immersion ................................. Pass effective. Consult catalyst MSDS and
Reducer…..Ready to spray as catalyzed Boiling Water Immersion ...................... Pass product label for complete handling
Humidity Resistance-3000 hrs ............. Pass
Air Assisted Airless: instructions.
Cold Crack Resistance, 15 Cycles ...... Pass
Air Assist Pressure .................10-20 psi Heat Age Test ...................................... Pass
Fluid Pressure ....................100-250 psi Weathering Resistance, 1 year South FL
Cap/Tip............................... as required @ 45 Degrees AAMA613-05 ............ Pass Note: Product Data Sheets are periodically
Reducer…..Ready to spray as catalyzed updated to reflect new information relating
Chemical Resistance Testing AAMA 614-05 to the product. It is important that the
Electrostatic Spray: customer obtain the most recent Product
10% Muriatic Acid Resistance ............ Pass Data Sheet for the product being used.
Reducer for polarity .......... Line Specific Mortar Resistance ................................ Pass
Reducer….. ..... Contact Representative The information, rating, and opinions
Nitric Acid Vapor Resistance................ Pass
Detergent Resistance........................... Pass stated here pertain to the material currently
HVLP: Window Cleaner Resistance ................ Pass offered and represent the results of tests
Gun ................................. Binks Mach 1 believed to be reliable. However, due to
Air Pressure at the cap ...........10-40 psi variations in customer handling and
Fluid Pressure ...........................5-10psi methods of application, which are not
Cap/Tip..............................As Required known or under our control, The Sherwin-
Williams Company cannot make any
Reducer…..Ready to spray as catalyzed warranties as to the end result.
Cleanup: WCBP/Columbus
Clean tools/equipment immediately after WMM
use with R6K10. 03/26/08
Flush equipment with solvent to prevent
rusting.