Sei sulla pagina 1di 2

Project: Trial Project

CAP ID: PC2


Engineer: SZ Date: 19 March 2013
Review: Date:
Devision: Design REF#: 0
KEO: Abu Dhabi Page:
Code: ACI 318-08M
Units: SI

CRITERIA:
f'c 50 MPa
Ec 33234.02 MPa
fy 460 MPa
Es 200000 MPa
Concrete Cover = 75 mm
Reinforcement Bar size = 32 mm
Number of layers = 1
Pile Embadement = 150 mm
Reinforcement Type b S= Straight
B=Bent
Ultimate Factor = 1.40
INPUTS:
Ø Shear = 0.75
Column Dead Load, Nd = 9,159 KN
Column Live Load, NL = 0 KN
Column Dimension X = 750 mm
Column Dimension, Y = 750 mm
Pile Diameter, dp = 900 mm
Pile Capacity, P = 4,580 KN Capacity of one pile
Pile Spacing, L = 2,250 mm
Pile Length = 12,000 mm
Cap Dimension, A = 3,800 mm
Cap Dimension, B = 1,525 mm
Cap Dimension, D = 1,800 mm
# Dia.
As = 8 32 6,434 mm2 Increase Reinforcement

CHECKS:
Minimum Pile Spacing 2.5Ø OK
Clearance/Length OK
Absolute spacing OK
Minimum Edge Distance 0.75Ø OK
Absolute Minimum OK
Clear Edge Distance OK
Project: Trial Project
CAP ID: PC2
Engineer: SZ Date: 19 March 2013
Review: Date:
Devision: Design REF#: 0
KEO: Abu Dhabi Page:
Number of Piles OK

CALCULATIONS:
Average to center of bars, dc = 241 mm
Edge distance, E = 775 mm
Horizontal Componant, w = 750 mm
Finding Flexure Section
Section width, b = 1,525 mm
Section depth, d = 1,559 mm
Finding Bending Moment
Maximum applied bending moment, M u = 5,290 KN-m
Maximum Shear Force,Vu = 6,412 KN
w/d ratio = 0.48
Finding the Critical Shear Sections
2-way at d/2 from face of column N/A
2-way at face of column N/A
1-way at d from face of column Critical Section at Column Face
1-way at face of column Found
Finding the Concrete Shear Strength (Special Investigations)
2-way at d/2 from face of column N/A
2-way at face of column N/A
1-way at d from face of column, Mpa N/A, Critical Section at Column Face
1-way at face of column, KN 7373.03
Finding Applied Shear Stress
2-way at d/2 from face of column N/A
2-way at face of column N/A
1-way at d from face of column, MPa N/A, Critical Section at Column Face
1-way at face of column, KN 6412.00

Check of Shear
2-way at d/2 from face of column N/A
2-way at face of column N/A
1-way at d from face of column N/A, Critical Section at Column Face
1-way at face of column OK

Vu/ØVn Ratio = 0.870