TABLES

Please refer Drafting standard for following types of table


1) Equipment Table (Refer Detail:EQ-018 of attachment-2)
2) Wall cut-out Table (Refer Detail:EQ-025 of attachment-2)
3) Floor cut-out Table (Refer Detail:EQ-026 of attachment-2)
4) Tray Legend Table (Refer Detail:CT-003 of attachment-3)
5) Route Point Table (Refer Detail:CT-013 of attachment-3)

1.1. CO-ORDINATES
1) The text of the coordinate shall be bold and three digit after decimal.
2) Co-ordinates shall be shown for independent electrical building/facility general arrangement
drawings only. For other building/areas (e.g. mech & civil building GA drawings), co-ordinates
are not to be shown.
3) As far as possible, the co-ordinates shall be marked at the same reference point as shown in the
plot plan or general arrangement drawing. In case where co-ordinates are not marked on plot
plan, then co-ordinate shall preferably mark on 1-A grid intersection point. See example below.
4) The coordinates shall be always plant coordinates.
5) Smart co-ordinate tool shall be used for marking co-ordinates. Refer Attachment-5: Steps for
Generating Smart Co-ordinate tool.