Sei sulla pagina 1di 8

SKF @ptitude Analyst

Powerful software for enterprise-wide


communications
SKF @ptitude Analyst is a core platform in a family of reliability software applications that work
together as SKF @ptitude Monitoring Suite.

SKF @ptitude Analyst is a


comprehensive software solution Enterprise Computerized
resource Maintenance
with powerful diagnostic and planning Management
System
analytical capabilities. SKF
SKF @ptitude
@ptitude Analyst provides fast, decision support

efficient and reliable storage,


analysis and retrieval of complex
machine information and makes the
information accessible throughout
your organization. On-line Periodic
surveillance/ vibration/
protection process data
• One software program to manage SKF @ptitude
machinery condition data from monitoring suite

portable and on-line devices


• One installation with limitless
expansion capabilities
• Easy to learn and use for novice
or experienced users
SKF @ptitude SKF @ptitude SKF @ptitude
• Interconnectivity with other Analyst Observer Inspector

software programs and systems


• Easy personalization for
individual users

When you select SKF @ptitude Analyst, you SKF @ptitude Analyst’s integrated platform
are immediately equipped to integrate and forms the hub to share information, foster
analyze data from the full range of SKF data teamwork, and facilitate consistent and
collection devices. This enterprise-wide reliable decision-making across functional
software platform allows operations, departments. The addition of SKF
maintenance and reliability staff to view the @ptitude Decision Support automates
integrated data and communicates the reliability maintenance decision-making by
information to each department in a identifying probable faults with an asset or
customized format to meet individual user process, then prescribing appropriate action.
needs. SKF @ptitude Analyst can
incorporate data from other sources such as
OPC servers and seamlessly interface to
your SAP, Computerized Maintenance
Management System (CMMS), Enterprise
Resource Planning (ERP) or other
information management systems.
Diagnosis and analysis
Managing the condition of your assets is easy Robust analytical and diagnostic capabilities
with SKF @ptitude Analyst that are easy to use
• Frequency fault diagnosis using SKF patented algorithms SKF @ptitude Analyst makes analysis easier by combining SKF
• Flexible setup gives you complete control patented fault-finding features, powerful data mining technology,
• Alarm viewing options let you quickly focus on priorities analytical displays and user-friendly graphics.
• Built-in tools streamline data management
• Identify and diagnose defect frequencies easier and faster than
Asset data customized for your unique needs even before with HAI (Harmonic Activity Index) calculations
• Preference options let SKF @ptitude Analyst work the way you
From the way you set up hierarchy, filtered workspaces, routes and work
analysis parameters, to the customized format for reporting, you are • Single views, trends and overlays expand your analysis
in control of powerful analysis tools. You can collect information capabilities
based on location, machine type, frequency, or other selections. SKF • Easy to read plots provide detailed information
@ptitude Analyst allows you to determine the appropriate limits for
alarm conditions and how alarms are categorized to ensure you SKF Analysis and Reporting Module (ARM)
receive consistent, reliable data in the format that suits you best.
SKF @ptitude Analyst features embedded ARM functionality to
Automated features simplify configuring and upload, view and post-process field data from the following SKF
fine- tuning alarms Microlog Analyzer AX/GX/MX application modules: Run up/Coast
down, FRF, Analyzer, Non-route, Balancing, Bump, Data Recorder
Since similar machines often use the same alarms, the Alarm and Check-to-Conformance. The field data can be then linked to
Database provides user-defined alarms that can be applied to create hierarchy nodes for future referencing.
alarm settings for multiple measurement points.
An Alarm Wizard assists in creating Statistical Alarms to set
alarms for your most important machinery with minimal research
and effort. SKF @ptitude Analyst considers historical data and
natural variation in vibration levels of machinery and generates a
reliable set of alarm criterion tailored to the specific machine.
SKF @ptitude Analyst’s variable speed alarming features
accommodate normal fluctuations in machine speed and function.
Alarm limits are automatically reset as speed changes, preventing
false alarms.

2
Transient Analysis (Run up/Coast down) Detailed information – efficiently organized
SKF @ptitude Analyst’s Transient Manager allows you to manage Screen displays such as data plot layout, color, size and position can
and display all transient hierarchy views. Depending on the transient be personalized and automatically updated. A customizable toolbar
view properties, the transient event may be automatically captured facilitates quick access to the program features you use most
at defined speed changes and other parameters to ensure accurate frequently.
analysis, such as, a turbine coast down event. Transient events may Right click on your data plot to modify settings and machine
be displayed in live or trend mode using these graphs: information. When you scroll across a data plot, data values are
displayed in the plot window.
• The Topology graph illustrates a series of spectra (similar to
Campbell plots) using a user-defined color scheme to easily Enhanced alarm view saves valuable time
visualize amplitude peaks. This graph also features vector
compensation. Alarm View window displays all points that require immediate
• The Bode graph with Damping Cursor is a dual plot consisting of attention to help you quickly identify, prioritize follow-up activities
phase and amplitude as function of rotational speed. The damping and acknowledge alarm conditions. The Alarm Details window offers
cursor enables you to identify resonance information at critical a comprehensive list of the specific points in alarm and the level and
speed when performing transient event analysis. type of alarm, all in one convenient view.
• The Nyquist graph plots the shaft’s movement during a transient Auto Linking makes it easy to view individual alarms because the
and is similar to a Bode graph but using polar notation. This graph data plots and alarm details change automatically as you select
also features vector compensation and optional rotational speed specific points, saving time and simplifying the analysis process.
labels.
• The Cascade graph plots data over running speed and features
data filtering options for optimal event presentation.

Informative transient mulit-pane plots allows you to see “the whole picture” when analyzing transient events within one
window.

3
Access and security
Versatile viewing options for multi-parameter Controlling access while effectively
analysis communicating information
For fast and easy comparison of two or more readings across SKF @ptitude Analyst permits access on a customized basis, yet
multiple points, SKF @ptitude Analyst allows you to select a allows the effective exchange of detailed information across
measurement and drag and drop it into the plot, providing functional departments.
convenience and saving time.
The SKF @ptitude Analyst frequency analysis feature helps to • Definable security protects your valuable data
identify specific bearing and gearbox frequency sets for rapid • Easy and flexible reporting options
detection and correction of bearing and machine problems. • Automated functions minimize human error
SKF @ptitude Analyst’s on-line data view automatically refreshes
to display the latest information, point status and alarm details. Live Advanced security system protects data
views provide immediate update of displayed data while the Event
Log documents specific occurrences over time. The System Four standard security levels are provided within SKF @ptitude
Information view provides one-stop navigation between different Analyst and an unlimited number of custom user security levels can
views such as Event Log, On-line Data view, individual routes and be created. Each level represents access rights that can be limited
workspaces. and controlled to prevent unauthorized use of the system and limit
SKF @ptitude Analyst’s database management tools allow you to the possibility of inadvertent damage to your valuable program
closely track machine problems to recreate events for predictive database.
maintenance and to perform root cause failure analysis.

Alarm view – Acknowledge alarm conditions and


type in comments. The Acknowledged alarm
note may be added to a report.

Multi-pane plots – SKF @ptitude Analyst allows


you to view multiple data plots in a single
window. View Orbit, Trend/Spectrum, Trend/
Spectrum/Time, and more to make the most
reliable and accurate decisions on machinery.

4
Customized reports Automatically schedule reports to save time
Extensive report customization features let the user control the The Scheduler Wizard enables a user to automatically schedule a
specific kinds of machine information to be communicated specific action, such as generating a report upon completion of a
throughout the organization. You can customize the templates or data collection upload, archiving measurement data at a specified
design an entirely new report including data plots, supplemental time or other event-based actions. This capability helps to eliminate
information and digital images. human error and allows the user to focus on other more pressing
Reports are generated in HTML format, giving you the flexibility to issues.
view on-screen, print, attach to an e-mail or post the report to your Using SKF @ptitude Analyst throughout your organization allows
company intranet – automatically. Other features allow you to collaboration and communication without losing control of your
maintain a history of reports, pre-configure report content and data.
format to share with selected users.

Personalized access rights allow the software


administrator to protect against errors and
enable traceability.

Predefined report templates make it easy to


generate common reports such as Last
Measurement, Exception, Overdue/Non-
compliant, History, Route Statistics, and others.

5
SKF @ptitude Analyst features and capabilities
Diagnosis Communication –– Trend/speed/time • Database supports
• Spectrum • Automatic report generation –– Waterfall/extracted trend/ –– XML data importing and
–– Harmonic Activity Index (HAI) based on a specified time, data spectrum exporting*
is a calculation that quantifies upload via scheduler wizard –– Waterfall/extracted band trend –– Binary importing and
the likelihood of harmonic • Data transfer with SKF MARLIN –– Trend/time waveform exporting
patterns being present in a and Microlog (CMVA, CMXA, GX –– Spectrum/band trend • Point configuration management
spectrum* and AX series) systems, Multilog –– Live views (Multilog) to quickly and easily make
–– Spectrum plot keyboard (DMx, TMU, CMU, LMU) and –– Live bars (Multilog) system-wide changes
shortcuts Wireless Monitoring System V/T NEW –– Bode/nyquist
• Time waveform • Download by Hierarchy, Route, or NEW –– Speed/bode/orbit/spectrum
General
–– Time domain statistics Workspace NEW –– Speed/bode/spectrum
• Multiple languages available
(standard deviation, skew, • Microsoft ActiveSynch • Graph overlays
• Windows®-based functionality
kurtosis and crest factor)* • Serial, USB, Ethernet and others • Time waveform
–– True multi-processing
• SKF Analysis and Reporting • OPC client interface available –– Time domain band cursor with
operating environment
Module* statistics*
Data display allowing simultaneous
NEW • Transient Analysis • Spectrum
• Multiple hierarchy background and foreground
–– Transient event views NEW –– Spectrum cascade
–– Manage multiple hierarchies processing
–– Vector compensation –– Spectrum diagnostics cursor
from one hierarchy view (my –– Complete right click
–– Live and trend mode graphs overlay*
hierarchies) functionality (drop down
–– Damping cursor –– Single, harmonic, sideband,
NEW • Transient analysis graphs menus)
peak, band cursors
Alarms –– Bode with damping cursor –– Drag and drop
–– On-screen defect frequency
• Alarm window –– Cascade with data and –– Cut/Copy/Paste
–– Running speed
–– Acknowledge alarms and enter frequency filtering –– Complete integration of third
–– Spectral band alarm
comments or –– Topology with user defined party applications
–– Spectral envelope alarm
recommendations colors • User preferences allow
–– Overall alarms
–– Quickly find and identify all –– Nyquist with speed labels customization
• Display tools
points in alarm within the • Machine node priority coloring • Context sensitive help
–– Display information area
hierarchy, group, route, • Orbit • Complete user manual on
–– On-screen text annotation
workspace, or machine –– Syncronized cursoring installation DVD
–– Percent of full scale setting
• Alarm details –– Smax locator • Product Support Plans (PSP)
–– Auto scaling
–– Provides a summary of type of –– Flash blank available
–– Cursor micro-manipulation
alarm and status –– Filtering –– Autolinking of displays and Measurements
• User defined alarm levels –– Vector compensation active hierarchy The following measurements can be
–– Public alarms that can be –– Waveform compensation –– Linear or log X or Y scaling entered manually or automatically
shared with other users –– True sensor angle –– Grid
–– Private alarms that can only be compensation • Acceleration
–– Orders, frequency scaling
used by specific users –– Tacho offset compensation • Amps
–– Amplitude threshold %
–– Unlimited number of alarms • Shaft centerline • Conditional points (MARLIN)
–– Waterfall slant angle setting
can be configured • Overall trend displays • Displacement
–– Date range setting
• Four overall alarm levels per • Machine condition detector • English or metric units
–– User selectable color settings
measurement point • Wireless machine condition • Enveloped acceleration
• Waterfall spacing (time/date
–– Danger high, alert high, alert detector • Flow (GPM, LPM)
based or event
low, danger low • Temperature • High Frequency Detection (HFD)
• Spectrum data post processing
–– Enhanced event log • Digital images and Digital High Frequency
(integration/differentiation)
capabilities (Multilog) • Spectrum displays (waterfall, Detection (DHFD)
• Baseline spectrum storage • Inspection points (user definable)
–– Out of window, in window, palogram)
level alarms supported • Single point, multiple point Database • Multi-channel (Microlog GX 2.0
• Alarm types displays • Built on Oracle database and Multilog DMx)
–– Overall forecast • Phase displays (polar vector, management system • Operating hours
–– Overall percent change magnitude/phase) • Microsoft SQL Server 2005 • Operating time (elapsed and
–– Unlimited spectral band • Triaxial point compatible cumulative)
(overall and peak) • Time waveform displays • ODBC, SQL, and TCP/IP protocol • Pressure (PSI and bars)
–– Spectral envelope –– Single point, multiple points compliant database opens the • RPM
–– Phase angle • Multi-channel displays database content • SEE (Spectral Emitted Energy)
–– Overall –– Stacked or combined multi- • Fully networkable in a Local Area • SKF acceleration enveloping (gE)
–– Inspection –– channel plots Network (LAN), Wide Area • Speed
–– Machine condition detector • Combination graphs Network (WAN), and Thin-client • Temperature (°C and °F)
–– Variable speed alarms –– Orbit/time (Terminal) environments • Triax
–– Crash alarm (Multilog, TMU –– Trend/spectrum • Unlimited number of: • User-specific units
only) –– Trend/spectrum/time –– Hierarchies • Velocity
–– BOV alarming waveform –– Collection points • Volts (AC or DC)
–– Statistical alarm calculation –– Trend/speed –– Measurements • Derived Point – user definable
–– Trend/speed/spectrum mathematical formula to calculate
–– Trend/speed/spectrum/time a derived value from data
collected on multiple points.

6
Hardware requirements
Reports Stand alone configuration
• Preserved reports – enables you • Running SKF @ptitude Analyst
to maintain a history of reports • Running Oracle or Microsoft SQL Server database management system
• Storing data
• Shared reports – allows you to
share and preconfigure reports for
selected users Configuration Minimum requirements Recommended requirements
• Send reports to screen, HTML
file, printer Operating system Windows 2000 with Service Pack 3+ OR Windows 2000 with Service Pack 3+ OR
• HTML file can be posted to Windows XP Professional with Service Pack 2 Windows XP Professional with Service Pack 2
internet, intranet, e-mailed
Processor (Note 1) Pentium IV, 2.1 GHz Intel Core 2 Duo or better
• HTML files can be opened and
modified further using Microsoft RAM 1.0 GB 2.0 GB or more
Office products, i.e. Word, Excel, Disk space available for 1.2 GB 1.2 GB or more
PowerPoint stand-alone computer (Note 2)
• Customizable report content DVD drive One (1) required One (1) required
• Data plots, supplemental
Video display 1024 x 768 1280 x 1024 or larger
information, and digital images
Oracle/Microsoft SQL Server Version 9i, 10g/SQL Server 2005 Version 9i, 10g/SQL Server 2005
can be included in reports
• Report types
–– Last measurement
–– Exception Network configuration – Server
–– Overdue/non-compliant • Running Oracle or Microsoft SQL Server database management system
–– Pending overdue/ • Storing data
non-compliant Network configuration for up to 35 Clients and one database.
Installations of 50 Clients or greater will require an on-site assessment by our Field Service Engineers
–– Collection status
–– Route history Configuration Minimum requirements Recommended requirements
–– Route statistics
–– Set statistics Operating system Windows 2003 Server, Windows 2003 Server,
–– Upload statistics
Windows 2000 with Service Pack 3 Windows 2000 with Service Pack 3
–– History
Processor (Note 1) Pentium IV, 2.1 GHz Intel Core 2 Duo or better
–– Inspection
–– Work notification RAM 2.0 GB 4.0 GB or more
–– Blank (user defined) Quantity of hard drives (Note 3) 3 5
–– Compliance Disk space available (Note 2) 1.2 GB 1.2 GB or more
• Report templates allow quick and DVD drive One (1) required One (1) required
easy report configuration for use
Oracle/Microsoft SQL Server Version 9i, 10g/SQL Server 2005 Version 9i, 10g/SQL Server 2005
and reuse
Security
• Fully configurable user rights that
Network configuration – Network Client
allow you to read, view and have • Running SKF @ptitude Analyst
full access • Running database client software
• Unlimited access levels Network configuration for up to 35 Clients and one database.
• Allows assignment of access Installations of 50 Clients or greater will require an on-site assessment by our Field Service Engineers
rights to user groups
• Hierarchy access – an enhanced Configuration Minimum requirements Recommended requirements
security feature that authorizes
Operating system Windows 2000 with Service Pack 3+ OR Windows 2000 with Service Pack 3+ OR
viewing and manipulation of
hierarchies. Windows XP Professional with Service Pack 2 Windows XP Professional with Service Pack 2
Processor (Note 1) Pentium IV, 2.1 GHz Intel Core 2 Duo or better
Templates and Wizards
RAM 1.0 GB 2.0 GB or more
• Statistical alarm wizards use
historical data to help refine Disk space available for 1.0 GB 1.0 GB or more
overall alarms each network client
• Hierarchy template wizard allows DVD drive One (1) required One (1) required
for rapid hierarchy creation and Video display 1024 x 768 1280 x 1024 or larger
machine templates for reuse
Oracle/Microsoft SQL Server Version 9i, 10g/SQL Server 2005 Version 9i, 10g/SQL Server 2005
• Report template allows for the
custom configuration of reports
and report templates for reuse Note 1: These requirements apply to SKF @ptitude Analyst complete with database management system. Other applications running simultaneously may
degrade performance.
• Scheduler wizard helps configure Note 2: These requirements ONLY apply to SKF @ptitude Analyst complete with database management system. Additional storage disk space is required
and preset recurring activities for data.
Note 3: The major benefits of spreading Oracle across three or more hard disks at the server is the improved speed, and improved recoverability of a
such as report generation, data previously archived database. The recommended five disk configuration provides the optimal protection for backup, recovery, indexing, and speed.
archival and task reminders Disk/file configuration should ONLY be handled by a SKF Field Service Technician certified on SKF @ptitude Analyst. If using RAID, the combination
of RAID 0 and RAID 1 is recommended over RAID 5.
Notice: If running other versions of Oracle, Microsoft SQL Server, or other database management system are expected to run in the same PC
* A CMSW 7400 feature environment, please contact your local SKF Representative to inquire about compatibility.

7
Ordering information Product Support Plans (PSP)
• SKF @ptitude Analyst software for Microlog, MARLIN, TMU, DMx, A range of Product Support Plans are available to protect your
CMU, LMU, MIM and Wireless Monitoring System V/T investment. Contact your local SKF Reliability Systems Sales
[CMSW 7400] Representative for additional information.
• SKF @ptitude Analyst for SKF Microlog Analyzer [CMSW 7300]
Installation and training
The SKF @ptitude Analyst is available in Single and Multi Client
configurations. Please contact your local SKF Reliability Systems Installation and training is available through your local SKF Supplier
representative for Multi Client model information. or Representative.

For additional information on SKF Reliability Systems products, contact:


SKF Reliability Systems
5271 Viewridge Court • San Diego, California 92123 USA
Telephone: +1 858-496-3400 • FAX: +1 858-496-3531
Web Site: www.skf.com/cm
® SKF, @ptitude, MARLIN, Multilog and Microlog are registered trademarks of the SKF Group.
Oracle is a registered trademark of Oracle Corporation.
Microsoft, Windows, PowerPoint, Excel and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries.
Intel is a registered trademark of Intel Corporation.
All other trademarks are the property of their respective owners.
© SKF Group 2009
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written
permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability
can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained
herein. SKF reserves the right to alter any part of this publication without prior notice.
SKF Patents include: #US04768380 • #US05679900 • #US05845230 • #US05854553 • #US05992237 • #US06006164 •
#US06199422 • #US06202491 • #US06275781 • #US06489884 • #US06513386 • #US06633822 • #US6,789,025 •
#US6,792,360 • US 5,633,811 • US 5,870,699 • #WO_03_048714A1
Publication CM2362 EN • February 2009 • Printed on environmentally friendly paper.

Potrebbero piacerti anche