TM

MASTER GRIPPERS
TECHNICAL DATA
CARBON STEEL & 300 SERIES STAINLESS STEEL CARBON STEEL & 410 SERIES STAINLESS STEEL
#10 MASTER GRIPPER #10 MASTER GRIPPER MINI DRILL P0INT
DIMENSIONAL PROPERTIES DIMENSIONAL PROPERTIES
A A

A Head Across Flats .244” - .250” A Head Across Flats .244” - .250”
B B
B Major Diameter .188” - .194” B Major Diameter .188” - .194”

C Minor Diameter .126” - .133” C Minor Diameter .126” - .133”


C C
Stress Area .00999 in.2 Stress Area .00999 in.2

STANDARD MECHANICAL REQUIREMENTS STANDARD MECHANICAL REQUIREMENTS


FOR LELAND AVERAGE VALUES SEE PAGE 23 FOR LELAND AVERAGE VALUES SEE PAGE 23
Carbon 300 Stainless Carbon 410 Stainless
Minimum Tensile Strength 2350 lbs. 1650 lbs. Minimum Tensile Strength 2350 lbs. 3040 lbs.
Minimum Torsional Strength 65 in.-lbs. 50 in.-lbs. Minimum Torsional Strength 65 in.-lbs. 105 in.-lbs.
Minimum Shear Strength 1460 lbs. 990 lbs. Minimum Shear Strength 1460 lbs. 1820 lbs.
PULL-OVER STRENGTH PULL-OUT STRENGTH
Expected pull-out strength from lab test per specified
18 .050”
12mm test plate thickness (70-85 Rb)
NOM. 1/2” .040” NO PRE-DRILLED HOLE LBS.
MASTER 20 1200
SEAL 22 .030” 1100
EPDM 24 • 1000
WASHER 26 • .020” • 900
.010” 800
1000

1200

1400

1600

1800

2000

2200

2400

• 700
400

600

800
#

600
REFER TO PAGE 8 FOR 500
PULL-OUT STRENGTH TECHNICAL DATA 400
• 300
• 200
• • 100
.010”

.020”

.030”

.040”

.050”

.060”

.070”

.080”

.090”

.100”

.110”

PLATE THICKNESS
#12 MASTER GRIPPER & #12 STITCH SCREW / / / / / / / /
26 24 20 18 16 14 13 12
A Head Across Flats .305” - .312” GAUGE REFERENCE

PULL-OVER STRENGTH
FOR MECHANICAL PROPERTIES PLEASE REFER TO
#12 INFORMATION ON PAGE 5 18 .050”
12mm
NOM. 1/2” .040”
MASTER 20
#10 NYLON HEADED MASTER GRIPPER SEAL 22 .030”

FOR MECHANICAL PROPERTIES PLEASE REFER TO


EPDM 24 •
#10 INFORMATION ON THIS PAGE
WASHER 26 • .020”

.010”
1000

1200

1400

1600

1800

2000

2200

2400
400

600

800
#

SHEAR STRENGTH - SEE INSIDE BACK COVER

Master Seal is a registered trademark of Aztec Washer Company Inc.


All test results and suggestions are based on laboratory tests. Specific job site conditions should be taken into consideration
when specifying the proper fasteners. Because applications vary, we assume no liability for use of this information.

3 MASTER GRIPPERS 2008