Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
; Update History:
; SAC 8/18/00 : Added "Heat Exchanger" folder near bottom of Water-Side HVAC
module
;
; ------------------------------------------------------------------------------
;
; Header:
; MODULE #, LEVEL # or END
; "string" => either entire label or to proceed component name
; NONE, BDL or BDB => source of components
; NONE ends the entry
; FOLDER ends the entry and identifies the entry as a folder which
; may contain one or more entries corresponding to different
; component types - used to implement component creation right
; mouse menus
; BDL -> next entry is BDL command
; BDB -> next entry is BDB component type
; ALL, CHILD, PARENTKEY, CHILDKEY => all components, children of this
; type, keyword assignment via parent keyword, keyword assignment
; via child keyword
; For PARENTKEY or CHILDKEY:
; # possible keyword assignments, KEYWORD[1-based array index], ...
; # of conditions under which components are to be added
; If # conditions > 0:
; If # conditions > 1:
; AND or OR indicating how conditions are processed
; Condition, Condition...
; where Condition => KEYWORD[1-based array] <operator> #,
; where <operator> => =, <, >, <=, >= or !=
;
; ------------------------------------------------------------------------------
; RW Access to the new BDL Command being placed here for testing purposes
LEVEL 1, "Liquid Circuits", FOLDER
LEVEL 2, "", BDL, REFG-CIRCUIT, ALL, 1, TYPE = 1
LEVEL 3, "", BDL, REFG-SYSTEM, PARENTKEY, 1, REFG-SYSTEM, 0
LEVEL 3, "", BDL, SUBCOOLER, PARENTKEY, 1, SUBCOOLER, 0
LEVEL 3, "", BDL, REFG-CIRCUIT, PARENTKEY, 1, TRUNK-CIRCUIT, 0
LEVEL 1, "Suction Circuits", FOLDER
LEVEL 2, "", BDL, REFG-CIRCUIT, ALL, 1, TYPE = 2
LEVEL 3, "", BDL, REFG-SYSTEM, PARENTKEY, 1, REFG-SYSTEM, 0
LEVEL 3, "", BDL, SUCTION-GROUP, PARENTKEY, 1, SUCTION-GROUP, 0
LEVEL 3, "", BDL, REFG-CIRCUIT, PARENTKEY, 1, TRUNK-CIRCUIT, 0
LEVEL 3, "", BDL, DESUPERHEATER, PARENTKEY, 1, DESUPERHEATER, 0
LEVEL 1, "Discharge Circuits", FOLDER
LEVEL 2, "", BDL, REFG-CIRCUIT, ALL, 1, TYPE = 3
LEVEL 3, "", BDL, REFG-SYSTEM, PARENTKEY, 1, REFG-SYSTEM, 0
LEVEL 3, "", BDL, REFG-CIRCUIT, PARENTKEY, 1, TRUNK-CIRCUIT, 0
LEVEL 1, "Subcoolers", FOLDER
LEVEL 2, "", BDL, SUBCOOLER, ALL, 0
LEVEL 3, "", BDL, REFG-CIRCUIT, PARENTKEY, 1, SUBCOOL-CIRCUIT, 0
LEVEL 3, "", BDL, REFG-CIRCUIT, PARENTKEY, 1, SUCTION-CIRCUIT, 0
; 2-Pipe Loops
LEVEL 1, "", BDL, CIRCULATION-LOOP, ALL, 2, AND, TYPE = 2, SUBTYPE = 1
LEVEL 2, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
LEVEL 2, "", BDL, CHILLER, CHILDKEY, 1, CHW-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
LEVEL 2, "", BDL, BOILER, CHILDKEY, 1, HW-PLANT, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, HW-PUMP, 0
LEVEL 2, "", BDL, THERMAL-STORAGE, CHILDKEY, 3, CHRG-LOOP, DCHRG-LOOP,
FREEZE-LOOP, 1, TYPE = 1
LEVEL 2, "", BDL, THERMAL-STORAGE, CHILDKEY, 2, CHRG-LOOP, DCHRG-LOOP,
1, TYPE = 2
LEVEL 2, "", BDL, HEAT-REJECTION, CHILDKEY, 1, PAN-HEATER-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, CHW-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
; LEVEL 2, "", BDL, STEAM-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
LEVEL 2, "Air-Side System(s)", FOLDER
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 5, DESC-LOOP, BBRD-LOOP,
PHW-LOOP, HW-LOOP, CHW-LOOP, 0
LEVEL 2, "Thermal Zone(s)", FOLDER
LEVEL 3, "", BDL, ZONE, CHILDKEY, 3, HW-LOOP, BBRD-LOOP, CHW-
LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, CIRCULATION-LOOP, CHILDKEY, 1, PRIMARY-LOOP, 1,
SUBTYPE = 2
; LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
; LEVEL 3, "", BDL, CHILLER, CHILDKEY, 1, CHW-LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
; LEVEL 3, "", BDL, BOILER, CHILDKEY, 1, HW-LOOP, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, HW-PUMP, 0
; LEVEL 3, "", BDL, THERMAL-STORAGE, CHILDKEY, 3, CHRG-LOOP, DCHRG-LOOP,
FREEZE-LOOP, 1, TYPE = 1
; LEVEL 3, "", BDL, THERMAL-STORAGE, CHILDKEY, 2, CHRG-LOOP, DCHRG-LOOP,
1, TYPE = 2
; LEVEL 3, "", BDL, HEAT-REJECTION, CHILDKEY, 1, PAN-HEATER-LOOP, 0
; LEVEL 4, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
;; RW 09/26/01 removed the below default to work with the new refrigeration dll
;; LEVEL 3, "", BDL, CHW-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
; LEVEL 3, "", BDL, STEAM-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
; LEVEL 3, "Air-Side System(s)", FOLDER
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 5, DESC-LOOP, BBRD-LOOP,
PHW-LOOP, HW-LOOP, CHW-LOOP, 0
; LEVEL 3, "Thermal Zone(s)", FOLDER
; LEVEL 4, "", BDL, ZONE, CHILDKEY, 3, HW-LOOP, BBRD-LOOP,
CHW-LOOP, 0
; HW Loops
LEVEL 1, "", BDL, CIRCULATION-LOOP, ALL, 2, AND, TYPE = 4, SUBTYPE = 1
LEVEL 2, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
LEVEL 2, "", BDL, BOILER, CHILDKEY, 1, HW-PLANT, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, HW-PUMP, 0
LEVEL 2, "", BDL, THERMAL-STORAGE, CHILDKEY, 2, CHRG-LOOP, DCHRG-LOOP,
1, TYPE = 2
LEVEL 2, "", BDL, THERMAL-STORAGE, CHILDKEY, 1, FREEZE-LOOP, 1, TYPE = 1
LEVEL 2, "", BDL, CHILLER, CHILDKEY, 2, HW-LOOP, HTREC-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
LEVEL 2, "", BDL, HEAT-REJECTION, CHILDKEY, 1, PAN-HEATER-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, STEAM-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
LEVEL 2, "", BDL, ELEC-GENERATOR, CHILDKEY, 3, EXH-LOOP, JAC-LOOP,
STEAM-LOOP, 0
LEVEL 2, "Air-Side System(s)", FOLDER
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 4, DESC-LOOP, BBRD-LOOP,
PHW-LOOP, HW-LOOP, 0
LEVEL 2, "Thermal Zone(s)", FOLDER
LEVEL 3, "", BDL, ZONE, CHILDKEY, 2, HW-LOOP, BBRD-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, CIRCULATION-LOOP, CHILDKEY, 1, PRIMARY-LOOP, 1,
SUBTYPE = 2
; LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
; LEVEL 3, "", BDL, BOILER, CHILDKEY, 1, HW-LOOP, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, HW-PUMP, 0
; LEVEL 3, "", BDL, THERMAL-STORAGE, CHILDKEY, 2, CHRG-LOOP, DCHRG-LOOP,
1, TYPE = 2
; LEVEL 3, "", BDL, THERMAL-STORAGE, CHILDKEY, 1, FREEZE-LOOP, 1, TYPE =
1
; LEVEL 3, "", BDL, CHILLER, CHILDKEY, 2, HW-LOOP, HTREC-LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
; LEVEL 3, "", BDL, HEAT-REJECTION, CHILDKEY, 1, PAN-HEATER-LOOP, 0
; LEVEL 4, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
; LEVEL 3, "", BDL, STEAM-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
; LEVEL 3, "", BDL, ELEC-GENERATOR, CHILDKEY, 3, EXH-LOOP, JAC-LOOP,
STEAM-LOOP, 0
; LEVEL 3, "Air-Side System(s)", FOLDER
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 4, DESC-LOOP, BBRD-LOOP,
PHW-LOOP, HW-LOOP, 0
; LEVEL 3, "Thermal Zone(s)", FOLDER
; LEVEL 4, "", BDL, ZONE, CHILDKEY, 2, HW-LOOP, BBRD-LOOP, 0
; WLHP Loops
LEVEL 1, "", BDL, CIRCULATION-LOOP, ALL, 2, AND, TYPE = 7, SUBTYPE = 1
LEVEL 2, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
LEVEL 2, "", BDL, CHILLER, CHILDKEY, 2, CW-LOOP, HTREC-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
LEVEL 2, "", BDL, BOILER, CHILDKEY, 1, HW-PLANT, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, HW-PUMP, 0
LEVEL 2, "", BDL, GROUND-LOOP-HX, CHILDKEY, 1, CIRCULATION-LOOP, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, HX-PUMP, 0
LEVEL 2, "", BDL, HEAT-REJECTION, CHILDKEY, 1, CW-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, STEAM-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
LEVEL 2, "", BDL, ELEC-GENERATOR, CHILDKEY, 2, EXH-LOOP, JAC-LOOP, 0
LEVEL 2, "Air-Side System(s)", FOLDER
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 3, CW-LOOP, WSE-LOOP,
REFG-CW-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
LEVEL 2, "Thermal Zone(s)", FOLDER
LEVEL 3, "", BDL, ZONE, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, CIRCULATION-LOOP, CHILDKEY, 1, PRIMARY-LOOP, 1,
SUBTYPE = 2
; LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
; LEVEL 3, "", BDL, CHILLER, CHILDKEY, 2, CW-LOOP, HTREC-LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
; LEVEL 3, "", BDL, BOILER, CHILDKEY, 1, HW-LOOP, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, HW-PUMP, 0
; LEVEL 3, "", BDL, GROUND-LOOP-HX, CHILDKEY, 1, CIRCULATION-LOOP, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, HX-PUMP, 0
; LEVEL 3, "", BDL, HEAT-REJECTION, CHILDKEY, 1, CW-LOOP, 0
; LEVEL 4, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
; LEVEL 3, "", BDL, STEAM-METER, CHILDKEY, 1, CIRCULATION-LOOP, 0
; LEVEL 3, "", BDL, ELEC-GENERATOR, CHILDKEY, 2, EXH-LOOP, JAC-LOOP, 0
; LEVEL 3, "Air-Side System(s)", FOLDER
;; RW 09/26/01 removed the below default to work with the new refrigeration dll
;; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 2, WSE-LOOP, REFG-CW-
LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, WSE-LOOP, 0
; LEVEL 3, "Thermal Zone(s)", FOLDER
; LEVEL 4, "", BDL, ZONE, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
; DHW Loops
LEVEL 1, "", BDL, CIRCULATION-LOOP, ALL, 2, AND, TYPE = 8, SUBTYPE = 1
LEVEL 2, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
LEVEL 2, "", BDL, DW-HEATER, CHILDKEY, 1, DHW-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, DHW-PUMP, 0
LEVEL 2, "", BDL, CHILLER, CHILDKEY, 1, HTREC-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
LEVEL 2, "", BDL, ELEC-GENERATOR, CHILDKEY, 2, EXH-LOOP, JAC-LOOP, 0
LEVEL 2, "Air-Side System(s)", FOLDER
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 1, DHW-LOOP, 0
LEVEL 2, "Thermal Zone(s)", FOLDER
LEVEL 3, "", BDL, ZONE, CHILDKEY, 1, DHW-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, CIRCULATION-LOOP, CHILDKEY, 1, PRIMARY-LOOP, 1,
SUBTYPE = 2
; LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
; LEVEL 3, "", BDL, DW-HEATER, CHILDKEY, 1, DHW-LOOP, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, DHW-PUMP, 0
; LEVEL 3, "", BDL, CHILLER, CHILDKEY, 1, HTREC-LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
; LEVEL 3, "", BDL, ELEC-GENERATOR, CHILDKEY, 2, EXH-LOOP, JAC-LOOP, 0
; LEVEL 3, "Air-Side System(s)", FOLDER
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, DHW-LOOP, 0
; LEVEL 3, "Thermal Zone(s)", FOLDER
; LEVEL 4, "", BDL, ZONE, CHILDKEY, 1, DHW-LOOP, 0
; CW Loops
LEVEL 1, "", BDL, CIRCULATION-LOOP, ALL, 2, AND, TYPE = 9, SUBTYPE = 1
LEVEL 2, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
LEVEL 2, "", BDL, HEAT-REJECTION, CHILDKEY, 1, CW-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
LEVEL 2, "", BDL, CHILLER, CHILDKEY, 1, CW-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
LEVEL 3, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
LEVEL 2, "", BDL, ELEC-GENERATOR, CHILDKEY, 1, CW-LOOP, 0
LEVEL 2, "Air-Side System(s)", FOLDER
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 3, CW-LOOP, WSE-LOOP,
REFG-CW-LOOP, 0
LEVEL 3, "", BDL, SYSTEM, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
LEVEL 2, "Thermal Zone(s)", FOLDER
LEVEL 3, "", BDL, ZONE, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
; RW 09/26/01 removed the below default to work with the new refrigeration dll
; LEVEL 2, "", BDL, CIRCULATION-LOOP, CHILDKEY, 1, PRIMARY-LOOP, 1,
SUBTYPE = 2
; LEVEL 3, "", BDL, PUMP, PARENTKEY, 1, LOOP-PUMP, 0
; LEVEL 3, "", BDL, HEAT-REJECTION, CHILDKEY, 1, CW-LOOP, 0
; LEVEL 4, "", BDL, HEAT-EXCHANGER, PARENTKEY, 2, DRY-HX, CW-HX, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 1, CW-PUMP, 0
; LEVEL 3, "", BDL, CHILLER, CHILDKEY, 1, CW-LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 1, DESC-CHILLER, 0
; LEVEL 4, "", BDL, PUMP, PARENTKEY, 4, CHW-PUMP, HW-PUMP, CW-
PUMP, HTREC-PUMP, 0
; LEVEL 3, "", BDL, ELEC-GENERATOR, CHILDKEY, 1, CW-LOOP, 0
; LEVEL 3, "Air-Side System(s)", FOLDER
;; RW 09/26/01 removed the below default to work with the new refrigeration dll
;; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 3, CW-LOOP, WSE-LOOP,
REFG-CW-LOOP, 0
; LEVEL 4, "", BDL, SYSTEM, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
; LEVEL 3, "Thermal Zone(s)", FOLDER
; LEVEL 4, "", BDL, ZONE, CHILDKEY, 2, CW-LOOP, WSE-LOOP, 0
END