Sei sulla pagina 1di 2

SGS INTRON Laboratory

P.O. box 5187 t +31 (0) 88 - 2 145 204


6130 PD Sittard f +31 (0) 88 - 2 144 609
The Netherlands

Certificate Of Analysis HBS Solutions B.V.


attn. de heer H. Sardha
Sniep 67
1112 AJ DIEMEN- NL
The Netherlands

Date : 04-10-2019
Subject : Tensile test on 2 coated M16x50 hex bolts class 10.9; DIN 933
sheradized
Your Code : IO190045
Laboratory Number : 193644
Sampling : 27-09-2019 at Diemen by HBS Solutions B.V.
Period of Investigation : 02-10-2019 until 04-10-2019

Sample Data
Sample No Sample Type Sample Code Date of Acceptance
1 grade 10.9 DIN 933 Sheradized M16x50 Hex Bolt 02-10-2019
2 grade 10.9 DIN 933 Sheradized M16x50 Hex Bolt 02-10-2019

Methods
Analysis Method Q s
Tensile Test Full Bolt ISO 6892-1; ISO 898-1

Q = ISO 17025 accredited, s=subcontracted, Qs = subcontractor (SGS Germany) ISO 17025 accredited

Results

Tensile test (Full Bolt RT)


Sample Diameter Length Nominal stress area Ultimate tensile load remarks
Bolt (acc. To table 4 ISO-898-1)

(mm) (mm) (mm2) (N)


Eis ISO 898-1 M16 → min. 163000
1 16,00 50 157 158790 Thread failure
2 16,00 50 157 175680 -

Author: R. Balter Authorisation: ing. M.J.G. Delamboy


accountmanager Business Development Manager

Page 1 of 2 Keurap04

Unless otherwise agreed, orders are executed in accordance with the latest version of the SGS INTRON B.V. General
Conditions. Upon simple request the conditions will again be sent to you.
Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Without written permission
from SGS INTRON Laboratory, this report may only be reproduced entirely.
The results are only related to the investigated samples.The scope of the NEN-EN-ISO/IEC 17025 accreditation involves all
results belonging to analyses marked with Q at the methods section.
The used significances of the results represent their uncertainty. Other performance characteristics are available upon request.
SGS INTRON Laboratory
P.O. box 5187 t +31 (0) 88 - 2 145 204
6130 PD Sittard f +31 (0) 88 - 2 144 609
The Netherlands

Samples after fracture

Laboratory Number: 193644 Page 2 of 2 Keurap04F


Without written permission from SGS INTRON Laboratory, this report may only be reproduced entirely.
The results are only related to the investigated samples.
The used significances of the results represent their uncertainty. Other performance characteristics are available upon request.