Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
A: Low Voltage Brushless DC Blowers 5.7" (145mm) BLDC Bypass Blower B21
1200 Watt, 240 Volt High Flow - IntelliGen (TM)
3.0" (76mm) BLDC Low-Voltage Blower A1
12/24 VDC EMI Filter B23
120/240 Volt AC
3.0 (76mm) BLDC Low-Voltage Blower A3
12/24 VDC Input, High Output Variable Flow Filters B24
For use with AMETEK Windjammer and Nautilair Blowers
3.3" (84mm) BLDC Low-Voltage Blower A5
12/24 VDC Nautilair (TM) 7.6" (193mm) Variable Speed Blower B25
12/24 VDC Input, Standard Output
4.5" (114mm) BLDC Low-Voltage Blower A7
12/24 VDC Nautilair (TM) 7.6" (193mm) Variable Speed Blower B27
120 Volt AC Input, Single Phase, Standard Output
5.0" (127mm) BLDC Low-Voltage Blower A9
12/24 VDC, Standard Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B29
240 Volt AC Input, Single Phase, Standard Output
5.0" (127mm) BLDC Low-Voltage Blower A11
12/24 VDC, High Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B31
240 Volt AC Input, Single Phase, High Output
5.1" (130mm) BLDC Low-Voltage Blower A13
24 VDC Nautilair (TM) 7.6" (193mm) Variable Speed Blower B33
120 Volt AC Input, Single Phase, Standard Output Enhanced
5.7" (145mm) BLDC Bypass Blower A15
24 VDC Input, Standard Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B35
240 Volt AC Input, Single Phase, Standard Output Enhanced
5.7" (145mm) BLDC Bypass Blower A17
24 VDC Input, High Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B37
120 Volt AC Input, Single Phase, High Output
5.7" (145mm) BLDC Thru Flow Blower A19
24 VDC Input, Standard Flow System Nautilair (TM) 8.0" (203mm) Variable Speed Blower B39
120 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Thru Flow Blower A21
24 VDC Input, High Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B41
120 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Bypass Blower A23
48 VDC Input, Standard Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B43
120 Volt AC Input, Single Phase, High Output
5.7" (145mm) BLDC Bypass Blower A25
48 VDC Input, High Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B45
240 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Thru Flow Blower A27
48 VDC Input, Standard Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B47
240 Volt AC Input, Single Phase, High Output
5.7" (145mm) BLDC Thru Flow Blower A29
48 VDC Input, High Flow System Nautilair (TM) 12.3" (312mm) Variable Speed Blower B49
120 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Bypass Blower A31
72 VDC Input, Standard Flow System Nautilair (TM) 12.3" (312mm) Variable Speed Blower B51
240 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Bypass Blower A33
72 VDC Input, High Flow System Nautilair (TM) 12.3" (312mm) Variable Speed Blower B53
240 Volt AC Input, Three Phase, High Output
5.7" (145mm) BLDC Thru Flow Blower A35
72 VDC Input, Standard Flow System C: Brushless DC Fans and Impeller-Style Blowers
5.7" (145mm) BLDC Thru Flow Blower A37 RTP10 12/24 VDC Brushless DC Fan C1
72 VDC Input, High Flow System RTP14 24 VDC Brushless DC Fan C3
B: High Voltage Brushless DC Blowers RTP16 12/24 VDC Brushless DC Fan C5
5.7" (145mm) BLDC Thru Flow Blower B1 RTP16S 12/24 VDC Brushless DC Fan C7
250 Watt, 120 Volt Standard Flow RTP1300 12/24 VDC Brushless DC Impeller Style Blower C9
5.7" (145mm) BLDC Thru Flow Blower B3 RTP1400 12/24 VDC Brushless DC Impeller Style Blower C11
250 Watt, 120 Volt High Flow RTP1600 12/24 VDC Brushless DC Impeller Style Blower C13
5.7" (145mm) BLDC Bypass Blower B5 D: Pumps
250 Watt, 120 Volt High Flow 10 Gallon Seal-less Pump, Brush Motor D1
5.7" (145mm) BLDC Bypass Blower B7 12 Gallon Seal-less Pump, Brushless Motor D3
250 Watt, 120 Volt Standard Flow 18 Gallon Seal-less Pump, Brushless Motor D5
5.7" (145mm) BLDC Thru Flow Blower B9 26 Gallon Seal-less Pump, Brushless Motor D7
400 Watt, 240 Volt Standard Flow
E: Controllers
5.7" (145mm) BLDC Bypass Blower B11 5 Amp BLDC Blower Controller E1
400 Watt, 240 Volt Standard Flow
5.7" (145mm) BLDC Bypass Blower B13
F: Blower Application Basics
400 Watt, 240 Volt High Flow
5.7" (145mm) BLDC Bypass Blower B15
800 Watt,120 Volt Standard Flow - IntelliGen(TM)
5.7" (145mm) BLDC Bypass Blower B17
800 Watt, 120 Volt High Flow - IntelliGen (TM)
5.7" (145mm) BLDC Bypass Blower B19
1200 Watt, 240 Volt Standard Flow - IntelliGen (TM)
Blower Selection
Blower Selection offers a wide variety of standard products available from AMETEK. Multiple
blower families are available in standard configurations. These include low voltage and high
voltage product lines. The low voltage products provide output pressure up to 97.7” H2O and
flows up to 160.3 CFM. The high voltage products provide outputs up to 169” H2O/420 mbar
(pressure) and flows up to 1100 CFM/1869 m3/hr.
® ®
AMETEK Windjammer Low Voltage Brushless DC blowers offer a wide range of performance for applications with power
supplies of 72 VDC and less. The following pages detail each model family, including performance, size, and input volt-
age.
All brushless DC blowers require an electronic controller for operation. Most of the model families herein are offered with
an onboard controller, and there are features and/or options available for customization.
Speed Control: Among the low voltage model families there are several methods for modulating blower speed.
Potentiometer Adjustment
ply adjusting a potentiometer on the side of the blower.
Analog Speed Command Signal
particular model, the range of the command signal is either 0-4V, 0-5V, or adjustable within 0-10V.
(i) For 5.0 inch Windjammer models equipped with analog speed command, blowers operate on a 0-4V com-
mand signal. Maximum speed is reached at 4V or less depending on the blower’s operating point. The speed com-
mand pin may by connected to the blower’s 12V or 24V Vin pin to ensure full speed.
(ii) The 5.7 inch Windjammer models have a calibration potentiometer that allows the user to set the range over
which the speed command signal operates within a 0-10V range, or to precisely calibrate a group of blowers to the
same speed for a given command voltage and operating condition.
(iii) Blowers designed for one of AMETEK’s low voltage external controllers can be configured to modulate
speed via either a 0-5V analog command signal or potentiometer adjustment as described above.
2-Wire Operation 3.0, 3.3, and 4.5 inch Windjammers operate with a different type of controller than other
model families. These blowers have a simple two-wire configuration. The blower speed is directly proportional to the
supply voltage, and there is no separate speed command signal input. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum specified supply voltage can be achieved by
providing a third wire to power the motor controller separately from the motor winding. This feature is available upon
request. The specification pages for each of these blower models list the supply voltage range.
Note: None of the blowers herein are designed to maintain constant speed if the blower operating point changes.
The speed will change with changing load (the amount of backpressure), even if the speed control remains fixed.
Tachometer Output: A square wave output that is proportional to blower speed comes as a standard feature in the
24VDC 5.7 inch Windjammer models, and it’s an option that is available in the 3.0, 3.3, and 4.5 inch Windjammers. The
output signal is a square wave whose signal is 2x the blowers rotational frequency:
External Controllers: All of the models herein can be configured to operate with a separate external controller, and
AMETEK’s product offering does include several stand-alone controller models. The 5.0 inch Windjammer model family
has standard blower models already configured for external control. The other models (3.0, 3.3, 4.5, and 5.7 inch Wind-
jammers) can be custom ordered to operate with an external controller - please contact an Ametek sales representative to
inquire. Note: the 5.1 inch Windjammer must use an external controller - it is not available with internal controller at this
time.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
1.31
vised to include a fuse for circuit protection.
Ø1.00 See performance sheets for individual blower models for fuse sizing.
[33.3]
[Ø25.4]
INLET
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
1.24
jammer pages herein for details.
[31.5] .78
5.0 inch Windjammers can be equipped with an external balancing disk for applications with
1.99 tight noise and vibra-
tion constraints.
2.67 Contact AMETEK Sales for inquiries regarding this feature.
[19.8] [50.6]
[67.8]
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
Part/ Model Number
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
Specification mer shares
Unitsa common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the
119349 analog speed
119350
command input is isolated from the power supply input. See pages herein for specifics about each model.
Voltage VDC 6-14 16-28
Stages - 1 1
in. H2O 13.4 14.0
Max Sealed Pressure
mbar 33.4 34.9
CFM 19.8 20.6
Max Open Flow Rate
m3/hr 33.7 35
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 9 oz. / .3 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbe
beconsidered
consideredas asaabinding
bindingdescription
descriptionof
ofthe
theproducts
productsor
ortheir
theirperformance
performanceininall
allapplications.
applications.TheTheperformance
performancedata
dataon
onthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunder
undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsiblefor
forblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flowflowor
orwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthe
theoperating
operatingenvironment
environmentand
andapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedfor
forand
andshould
shouldnot
notbe
beused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Solutions Sales
department.
department.
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal
Flow (mlimitations
3
/hr) of the motor and controller.
0 3 7 10 14 17 20 24 27 31 34 37
14 36
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection 119349 - 6VDC
12 30
5.1 inch Windjammer Locked rotor protection depends on the controller being119349
used. If -using
14VDCAmetek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 119350 - 16VDC
10 25
119350 - 28VDC
Pressure (inch H2O)
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
Pressure (mbar)
controller,
8 locked rotor protection depends on the controller design. Thermal protection is not available for this model
20
family.
3.0,
6 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are15 ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
4 10
2
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
1
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
0
0 2 4 6 8 10 12 14 16 18 20 22
25000
Speed (RPM)
20000
15000
10000
0 2 4 6 8 10 12 14 16 18 20 22
40
Power Demand
30
(Watts)
20
10
0
0 2 4 6 8 10 12 14 16 18 20 22
3
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document
This document is is for
for informational
informational purposes
purposes only
only and
and should
should not
not be
be considered
considered asas aa binding
binding description
description of
of the
the products
products or
or their
their performance
performance in in all
all applications.
applications. The
The performance
performance data
data on
on this
this page
page depicts
depicts
typical performance
typical performance under under controlled
controlled laboratory
laboratory conditions.
conditions. AMETEK
AMETEK is is not
not responsible
responsible for
for blowers
blowers driven
driven beyond
beyond factory
factory specified
specified speed,
speed, temperature,
temperature, pressure,
pressure, flow
flow or
or without
without proper
proper alignment.
alignment. Actual
Actual
performance will
performance will vary
vary depending
depending on
on the
the operating
operating environment
environment and
and application.
application. AMETEK
AMETEK products
products are
are not
not designed
designed for
for and
and should
should not
not be
be used
used inin medical
medical life
life support
support applications.
applications. AMETEK
AMETEK reserves
reserves the
the
right to
right to revise
revise its
its products
products without
without notification.
notification. The
The above
above characteristics
characteristics represent
represent standard
standard products.
products. For
For product
product designed
designed to to meet
meet specific
specific applications,
applications, contact
contact AMETEK
AMETEK Dynamic
Dynamic Fluid
Fluid Solutions
Solutions Sales
Sales
department.
department.
INCH 3.06
5.7 Bypass or Thru Flow:
[77,7]
The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
[MM] Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air
1.62
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
[41,2]
size but has a narrower range of operation due to thermalØ.56
limitations of the motor and controller.
[Ø14,2] #20 AWG LEADS
(.38 REF)
DISCHARGE
[9,7]
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal
Ø.85 protection
DISCHARGE [Ø21,6]
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection.
1.24
2.94 5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
[31,5]
[74,7] controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family. Ø1.78
MAX.
[Ø45,2]
3.0, 3.3, and 4.5 inch Windjammers These
INLET models have neither locked rotor nor thermal protection. Users are ad-
1.31 vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
[33,2]
Ø.80
Other Features and Miscellaneous [Ø20,3]Notes:
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 9 oz / .3 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
This
Thisdocument
documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.TheTheperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typical
typicalperformance
performanceunder undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnot notresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performance
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reservesthe
will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right
righttotorevise
reviseitsitsproducts
productswithout
withoutnotification.
notification.The
Theabove
abovecharacteristics
characteristicsrepresent
representstandard
standardproducts.
products.For
Forproduct
productdesigned
designedtotomeetmeetspecific
specificapplications,
applications,contact
contactAMETEK
AMETEKDynamic
DynamicFluid
FluidSolutions
SolutionsSales
Sales
department.
department.
AMETEK
AMETEK DYNAMIC
DYNAMIC FLUID
FLUID SOLUTIONS
SOLUTIONS A3
100
100 E.
E. Erie
Erie Street,
Street, Kent
Kent OH
OH 44240
44240
USA:
USA: +1+1 215-256-6601
215-256-6601 -- Europe:
Europe: +49
+49 7703
7703 930
930 909
909 -- Asia:
Asia: +86
+86 21
21 5763
5763 1258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
3.0 (76mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC Input, High Output
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
3
Flow (mlimitations
size but has a narrower range of operation due to thermal /hr) of the motor and controller.
0 4 9 13 17 21 25 30 34 38 42 47
28 70
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection 150908 - 16VDC
24 60
5.1 inch Windjammer Locked rotor protection depends on the controller being150908 - 28VDC
used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 150918 - 5VDC
20 50
150918 - 14VDC
Pressure (inch H2O)
Pressure (mbar)
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller,
16 locked rotor protection depends on the controller design. Thermal protection is not available for this model
40
family.
3.0,
12 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are30 ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
8 20
4
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
2.5
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
1
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5
34000
Speed (RPM)
26000
18000
10000
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5
70
Power Demand
54
(Watts)
38
22
6
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK DYNAMIC FLUID SOLUTIONS A4
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
3.3" (84mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
INCH 4.42
[112.2]
[MM] 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Thru Flow. The Bypass configuration2.87 separates the motor and controller from.78 the working air, #20
whereas the working air
AWG LEADS
[72.8]in a Thru Flow configuration. The Thru
passes over the motor and controller [19.8] Flow configuration shortens the package
DISCHARGE
size but has a narrower range of operation due to thermal limitations of the motor and controller.Ø.54
[Ø13.7]
DISCHARGE
Locked-Rotor and Thermal Protection:
1.40
5.7 inch Windjammers All models include locked rotor and thermal[35.6]
Ø.76 protection
3.29 [Ø19.3] dependsØ.86
[83.6]
5.1 inch Windjammer Locked rotor protection on the controller being used. If using Ametek 48140 con-
[Ø21.8] Ø1.75
troller, locked rotor protection is enabled. No thermal protection. [Ø11.5]
Ø.75 INLET
5.0
1.50
inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
[Ø19.1]
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
[38.1]
family. Ø.50
3.0, 3.3, and 4.5 inch Windjammers [Ø12.7] These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit INLET
1.44 protection. See performance sheets for individual blower models for fuse sizing.
[36.6] .75 1.99
[19.1] [50.6]
2.99
Other Features and Miscellaneous
[76] Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for
Part/ Model applications with tight noise and vibra-
Number
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Specification Units 119497 119498
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
Voltage mentioned VDC above. This allows very low input
6-13 voltage on the motor (low speed) without shutting 16-26
down the drive
Stages electronics.- 1
The controller Vin can be configured to accept a specific supply voltage depending1 on an
in. H2O 26.0 26.0
Max Sealed Pressure application’s needs.
mbar 64.8 64.8
5.7 Windjammers
CFM designed for 48V and 72V
6.6 input do not have an option for tachometer output at7.1
this time. 24V
Max Open Flow Rate
models m3/hr
have a tachometer output as a standard
11.2 feature. Also, the analog speed command for 24V12.1 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 9 oz / .3 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEK DYNAMIC
DYNAMIC FLUID
FLUID SOLUTIONS
SOLUTIONS A5
100
100 E.
E. Erie
Erie Street,
Street, Kent
Kent OH
OH 44240
44240
USA:
USA: +1
+1 215-256-6601
215-256-6601 -- Europe:
Europe: +49
+49 7703
7703 930
930 909
909 -- Asia:
Asia: +86
+86 21
21 5763
5763 1258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
3.3" (84mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal
Flow (mlimitations
3
/hr) of the motor and controller.
0 1.7 3.4 5.1 6.8 8.5 10.2 11.9
30 75
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
25
5.1 inch Windjammer 119498
Locked rotor protection depends on the controller being used.16VDC
62
If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 119498 26VDC
119497 6VDC
Pressure (inch H2O)
20 50
5.0 inch Windjammers All models with on-board controllers include locked rotor protection.
13VDC If using an external
Pressure (mbar)
119497
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
15 37
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
10 25
Other Features
5 and Miscellaneous Notes: 12.5
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer
0
pages herein for details. 0
5.0 inch
0 Windjammers
1 can be equipped
2 with an3 external balancing
4 disk for applications
5 with
6 tight noise and
7 vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Flow (CFM)
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
3
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)
2
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
1
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
0
0 1 2 3 4 5 6 7
32000
Speed (RPM)
26000
20000
14000
0 1 2 3 4 5 6 7
36
Power Demand
24
(Watts)
12
0
0 1 2 3 4 5 6 7
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A6
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601--Europe:
Europe:+49
+497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
4.5" (114mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
CL
INCH .24
[MM] 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family .20 offers two flow
[6.1] path configurations: Bypass or
Thru Flow. The Bypass configuration
2.12 separates the motor and controller [5.1]from the working2Xair, 8-32whereas
INSERT the working air
[53.8] .25 MIN THREAD DEPTH
passes over the motor and controller in a Thru Flow configuration.1.03The Thru Flow configuration [6.4] shortens the package
size but has a narrower range of operation due toDISCHARGE [26.2]
thermal limitations of the motor and controller.
.53 x .32
1.53 [13.5 x 8.1]
#20 AWG LEADS
[38.9] DISCHARGE
Locked-Rotor and Thermal Protection:
4.49 1.69
[114.0]5.7 inch Windjammers All models include locked rotor and[43.0]
thermal protection
1.17
Ø.88 [29.7]
5.1 inch Windjammer Locked rotor protection
depends on the controller being used. If using AmetekØ1.75
[Ø22.3] 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [Ø44.4]
INLET
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
2.04
controller,
[51.8]
locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers TheseØ.60
models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. [Ø
See performance sheets for individual blower models for fuse sizing.
15.2]
1.78 INLET .57
[45.2] [14.5]
4.05 .22 1.99
Other Features and Miscellaneous
[102.9] Notes: [5.6] [50.5]
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for
Part/ Model applications with tight noise and vibra-
Number
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Specification Units 119494 119395
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
Voltage mentioned VDC above. This allows very low input
6-14 voltage on the motor (low speed) without shutting 16-28
down the drive
Stages electronics.- 1
The controller Vin can be configured to accept a specific supply voltage depending1 on an
in. H2O 37.1 37.8
Max Sealed Pressure application’s needs.
mbar 92.4 94.2
5.7 Windjammers
CFM designed for 48V and 72V
10.9 input do not have an option for tachometer output at this time. 24V
10.6
Max Open Flow Rate
models m3/hr
have a tachometer output as a standard
18.5 feature. Also, the analog speed command for 24V 18 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
Notes: command input is isolated from the power supply input. See pages herein for specifics about each model.
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 13 oz / .4 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A7
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
4.5" (114mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal
Flow (mlimitations
3
/hr) of the motor and controller.
0 3.4 6.8 10.2 13.6 17 23.8 27.2
60 149
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
50
119494 6VDC 124
5.1 inch Windjammer Locked rotor protection depends on the controller being used.14VDC
119494 If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 119395 16VDC
Pressure (inch H2O)
40 99
5.0 inch Windjammers All models with on-board controllers include locked rotor
119395protection.
28VDC If using an external
Pressure (mbar)
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
30 74
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
20 50
Other Features
10 and Miscellaneous Notes: 25
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer
0
pages herein for details. 0
5.0 inch
0 Windjammers
2 can be equipped
4 with an6 external balancing
8 disk for 10
applications with
12 tight noise and
14 vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Flow (CFM)
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
6
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)
4
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
2
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
0
0 2 4 6 8 10 12 14
30000
Speed (RPM)
24000
18000
12000
0 2 4 6 8 10 12 14
90
Power Demand
60
(Watts)
30
0
0 2 4 6 8 10 12 14
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This
Thisdocument
documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.TheTheperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typical
typicalperformance
performanceunder undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnot notresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performance
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reservesthe
will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right
righttotorevise
reviseitsitsproducts
productswithout
withoutnotification.
notification.The
Theabove
abovecharacteristics
characteristicsrepresent
representstandard
standardproducts.
products.For
Forproduct
productdesigned
designedtotomeetmeetspecific
specificapplications,
applications,contact
contactAMETEK
AMETEKDynamic
DynamicFluid
FluidSolutions
SolutionsSales
Sales
department.
department.
AMETEKDYNAMIC
AMETEK DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A8
100E.
100 E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:+1
USA: +1215-256-6601
215-256-6601--Europe:
Europe:+49
+497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, Standard Flow System
INCH 2.82
[MM] 3X Ø.168 5.7 [71.6]
[Ø4.27] Bypass
x .31/[7.8] DEEP or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
2.50 1.50
Thru Flow.
HOLES EQUALLY
Ø3.228
SPACED The Bypass configuration separates the motor
[63.5] Ø.88 and controller from
[38.1]
the working air, whereas the working air
[Ø82.00]passes over the motor and controller in a Thru Flow [Ø22.4]
BOLT CIRCLE configuration. The Thru Flow configuration shortens the package
DISCHARGE
size but has a narrower range of operation due to thermal limitations .80 of the motor and controller.
[20.3]
Ø3.81
[Ø96.8] 1.27
[32.3]
Locked-Rotor and Thermal Protection: Ø1.50
2.06 [Ø38.1]
5.7 inch Windjammers All models include locked rotor and thermal protection
[52.3] INLET
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [Ø31.8]
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. OPTIONAL:
Users are ad-
Ø1.25
3X Ø.35 BOSSES
vised to include a fuse for circuit protection. See performance sheets COVER SHELL
[Ø8.9] .21 for individual blower models for fuse
3X
sizing.
WITH INLET TUBE
EQUALLY SPACED ON A [5.3]
Ø3.228 BOLT CIRCLE. Ø5.00
[Ø82.00] [Ø127.0]
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
Part/ Model Number
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
Specification tion constraints.
Units Contact AMETEK Sales
119380 for inquiries regarding
119381 119382 this feature.119383 119384 119385
Voltage 3.0, 3.3, VDC
and 4.5 inch Windjammers
12 can be12configured to have
12 separate Vin for24
the controller and24
the motor, as 24
Stages mentioned- above. This 1allows very low input
1 voltage on the motor
1 (low speed) 1without shutting down
1 the drive 1
Max. Sealed Pressure
electronics.
in. H2O The controller
13.5 Vin can be 13.5
configured to accept
13.5 a specific supply
12.5 voltage depending
12.5 on an 12.5
application’s
mbar needs. 33.6 33.6 33.6 31.1 31.1 31.1
CFM 32.3 32.3 32.3 35.3 35.3 35.3
Max Open Flow Rate
5.7 Windjammers
m3/hr designed
54.9 for 48V and 72V54.9 input do not have
54.9 an option for tachometer
60 output at60this time. 24V 60
Speed Control models have
- a tachometer
Externaloutput asPotent.
a standard
Adjust.feature.
0-4VAlso,
Spd. the
Cmd.analog speed command Potent.
External for 24V 5.7 Windjam-
Adjust. 0-4V Spd. Cmd.
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Models 119380 thru 119385 can be configured and modified for two (2) plane balance option.
• Optional - cover shell with air inlet tube.
• Weight = 1.2 lb / .54 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied to power the blower and the speed is set by adjusting a potentiometer
on the side of the blower.
0-4V Speed Command (0-4V Spd. Cmd.)- Blower speed is proportional to a 0-4V command signal. Maximum speed is reached at 4V or less depending on
the blower’s operating point. The speed command pin may be connected to the blower’s 12V or 24V pin to ensure full speed.
External Control - Designed to operate with an external controller such as AMETEK’s model 48133.
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A9
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, Standard Flow System
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.
Flow (m3/hr)
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
Pressure (mbar)
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 10
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
USA: +1 215-256-6601 -
44240
USA: +1 215-256-6601 - Europe:+49
Europe: +497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258
____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, High Flow System
2.82
INCH [71.6]
3X Ø.168 x .31/[7.8] DEEP
[MM] 5.7 Bypass or Thru Flow:
[Ø4.27]
HOLES EQUALLY SPACED
The 5.72.50
inch Windjammer product family offers1.50 two flow path configurations: Bypass or
Thru
Ø3.228
BOLT
Flow.
CIRCLE
The Bypass configuration[63.5]
separates the motorØ.88 and controller from the working air, whereas the working air
[38.1]
[Ø82.00] [Ø22.4]
passes over the motor and controller in a Thru Flow configuration.
DISCHARGE The Thru Flow configuration shortens the package
.80
size but has a narrower range of operation due to thermal limitations of the motor and controller.
[20.3]
Ø3.81
[Ø96.8] 1.27
[32.3]
Locked-Rotor and Thermal Protection: Ø1.50
2.06 [Ø38.1]
5.7 inch Windjammers All models include locked [52.3]
rotor and thermal protection INLET
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [Ø31.8]
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
OPTIONAL: Ø1.25
3X Ø.35 BOSSES
vised to include a fuse for circuit protection. See performance sheets COVER SHELL
[Ø8.9] .21 for individual blower models for fuse sizing.
3X WITH INLET TUBE
EQUALLY SPACED ON A [5.3]
Ø3.228 BOLT CIRCLE. Ø5.00
[Ø82.00] [Ø127.0]
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
Part/ Model Number
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
Specification tion constraints.
Units Contact AMETEK
150166 Sales for inquiries119375
regarding this feature. 119378 119379
Voltage 3.0, 3.3, VDC
and 4.5 inch Windjammers
12 can be configured to
24have separate Vin for the controller
24 and the motor, as24
Stages mentioned- above. This allows 1 very low input voltage on1the motor (low speed) without
1 shutting down the drive 1
Max. Sealed Pressure
electronics.
in. H2O The controller20.1
Vin can be configured to24.9
accept a specific supply 24.9
voltage depending on an 24.9
application’s
mbar needs. 50.1 62 62 62
CFM 37.7 44.6 44.6 44.6
Max Open Flow Rate
5.7 Windjammers
m3/hr designed64.1
for 48V and 72V input do not
75.8have an option for tachometer
75.8 output at this time. 24V
75.8
Speed Control models have
- a tachometer output
0-4V Spd. as a standard feature.
Cmd. Also, the analog speed
External command
Potent. Adjust. for 24V 5.7 Windjam-
0-4V Spd. Cmd.
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Models 119380 through 119385 can be configured and modified for two (2) plane balance option.
• Optional - cover shell with air inlet tube.
• Weight = 1.2 lb / .54 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied to power the blower and the speed is set by adjusting a potentiometer
on the side of the blower.
0-4V Speed Command (0-4V Spd. Cmd.)- Blower speed is proportional to a 0-4V command signal. Maximum speed is reached at 4V or less depending on
the blower’s operating point. The speed command pin may be connected to the blower’s 12V or 24V pin to ensure full speed.
External Control - Designed to operate with an external controller such as AMETEK’s model 48133.
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 11
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, High Flow System
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.
Flow (m3/hr)
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection.
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
Pressure (inch H2O)
Pressure (mbar)
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This
Thisdocument
documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.TheTheperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typical
typicalperformance
performanceunder undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnot notresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performance
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reservesthe
will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right
righttotorevise
reviseitsitsproducts
productswithout
withoutnotification.
notification.The
Theabove
abovecharacteristics
characteristicsrepresent
representstandard
standardproducts.
products.For
Forproduct
productdesigned
designedtotomeetmeetspecific
specificapplications,
applications,contact
contactAMETEK
AMETEKDynamic
DynamicFluid
FluidSolutions
SolutionsSales
Sales
department.
department.
AMETEKDYNAMIC
AMETEK DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 12
100E.
100 E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:+1
USA: +1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.1" (130mm)
General Information
BLDC Low-Voltage Blower
24 VDC
INCH 2.22 2.48 CL
[56,4] [63] .27
[MM]
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product1.212
family offers two flow
[6,9] 2x path configurations: Bypass or
8-32 INSERT
.25 MIN THREAD DEPTH
Thru Flow. The Bypass configuration separatesDISCHARGE
the motor and controller from the working
[30,78]
[6.4]
air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due
1.71 to thermal limitations of the motor and controller.
.42 x .71
[43,4]
[10,7 x 18]
2.82 DISCHARGE
[71,6] 1.965
Locked-Rotor and Thermal Protection: [49,91]
1.36
[34,5]
5.7 inch Windjammers All models include locked rotor and thermal protection
Ø1.77
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek
[Ø45]48140 con-
troller, locked rotor protection is enabled. Ø.98
No thermal protection. INLET
[Ø24,9]
5.0
2.325inchWindjammers All models with on-board controllers include locked rotor protection. If using an external
[59,06]
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family. Ø.700
[Ø17,78]
#20 AWG LEADS
3.0, 3.3, and 4.5 inch Windjammers INLETThese models have neither locked rotor nor thermal protection. Users are ad-
.31
vised to include a fuse for circuit protection. See performance sheets[7,9]
for individual blower models for fuse sizing.
.72 2.44
[18.3] [62]
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details. Part/ Model Number
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
Specification Units
tion constraints. Contact AMETEK Sales for inquiries regarding this150193
feature.
Voltage
3.0, 3.3, VDC
and 4.5 inch Windjammers can be configured to have separate24
Vin for the controller and the motor, as
Stages - 1
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
in. H2O 50.9
Max Sealed Pressure electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
mbar 126.8
application’s
CFM needs. 26.3
Max Open Flow Rate
m3/hr 44.7
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
Notes: mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command
• This blower is designed input is
to operate isolated
with from3-phase
an external the power supply
controller input.
such See pages
as AMETEK’s herein
model 48140.for specifics
Speed about
control each
method is amodel.
function of the controller
that drives the blower. If using AMETEK‘s 48140, the controller can be set to control speed by potentiometer adjustment or by 0-5V analog speed command.
Customized controller functions are available - contact AMETEK sales to inquire.
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Product includes a two (2) plane balancing option for reduced vibration.
• Weight = 16 oz / .5 kg
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 13
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601--Europe:
Europe:+49
+497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.1" (130mm)
General Information
BLDC Low-Voltage Blower
24 VDC
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.
Flow (m3/hr)
Pressure (mbar)
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 14
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
USA: +1 215-256-6601 -
44240
USA: +1 215-256-6601 - Europe:+49
Europe: +497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258
____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System
INCH 3.74 [95.0]
[MM]
DISCHARGE Ø1.75
[Ø44.4]
Ø5.88
[Ø149.4]
INLET
Ø1.75
[Ø44.4]
Ø2.60
[Ø66.0]
MOTOR VENTING 45°
26° Ø.17HOLE THRU,
[Ø4.3]
CL LOCATED AS SHOWN ON A
SPEED CONTROL/ Ø6.40 1.04 .88
CALIBRATION 33° [Ø162.6] BOLT CIRCLE [26.4] [22.4]
90°
1.00 3.31 (2X)
[25.4] [84.1] Ø.17
MOTOR 3X [Ø4.3] HOLES THRU,
VENTING LOCATED AS SHOWN ON A
49° 4.66 "L"
[118.4] Ø6.50
[Ø165.10] BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION
4.00
2.79 [101.6]
[70.9]
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.
Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
150400, 150431
150401, 150432
150402, 150433
Pressure (inch H2O)
Pressure (mbar)
0 10 20 30 40 50 60 70 80 90
Flow (CFM)
24
20
Current (A)
16
12
8
4
0 10 20 30 40 50 60 70 80 90
20000
Speed (RPM)
18000
16000
14000
0 10 20 30 40 50 60 70 80 90
600
Power Demand
500
(Watts)
400
300
200
100
0 10 20 30 40 50 60 70 80 90
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
DISCHARGE
"D2"
Ø5.88
[Ø149.4]
INLET
"D1"
Ø2.60
[Ø66.0]
MOTOR VENTING 45°
26° Ø.17
[Ø4.3] HOLE THRU,
CL LOCATED AS SHOWN ON A
Ø6.40 1.04 "A"
SPEED CONTROL/ 33° [Ø162.6] BOLT CIRCLE [26.4]
90°
CALIBRATION 1.00 3.31 (2X)
[25.4] [84.1] Ø.17
MOTOR 3X [Ø4.3] HOLES THRU,
VENTING LOCATED AS SHOWN ON A
49° 4.66 Ø6.50 BOLT CIRCLE
[118.4] "L" [Ø165.10]
ACCESS TO
SPEED CONTROL/
CALIBRATION
4.00
2.79 [101.6]
[70.9]
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.
Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 17
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System
Typical Performance
150403, 150434
150404, 150435
Pressure (inch H2O)
150405, 150436
Pressure (mbar)
Flow (CFM)
27
24
Current (A)
21
19
16
13
10
7
Speed (RPM)
700
Power Demand
575
(Watts)
450
325
200
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.74
DISCHARGE [95.0]
ACCESS TO
SPEED CONTROL/
CALIBRATION Ø1.75
[Ø44.4]
24°
INLET
Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.
Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 19
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
24 VDC Input, Standard Flow System
Typical Performance
150406, 150437
150407, 150438
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
DISCHARGE Ø1.75
ACCESS TO [Ø44.4]
SPEED CONTROL/
CALIBRATION
24°
INLET Ø1.75
[Ø44.4]
45°
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2]
(3X)
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.
Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output sigal is 2x the blower’s rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 21
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
24 VDC Input, High Flow System
Typical Performance
(at constant 24V input)
Flow (m3/hr)
150409, 150439
150410, 150440
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
19200
18000
Speed (RPM)
16800
15400
14200
13000
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
DISCHARGE
Ø1.75
[Ø44.4]
Ø5.88
[Ø149.4]
INLET
Ø2.60 Ø1.75
[Ø66.0] [Ø44.4]
MOTOR VENTING
2.40
[61.0]
12
34 45°
CL 5 Ø.17
[Ø4.3]HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40
[Ø162.6]BOLT CIRCLE 1.04 .88
[26.4] [22.4]
49° 26° 33° 90°
1.00 3.2 (2X)
[25.4] [81] Ø.17
3X[Ø4.3] HOLES THRU,
"A" MOTOR
VENTING LOCATED AS SHOWN ON A
4.66 "L" Ø6.50
[118.4] [Ø165.10] BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION
(1.38)
([35.1])
2.79
[70.9]
3.29
[83.6]
VIEW "A"
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of
the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
150411, 150441
150412, 150442
150413, 150443
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
DISCHARGE
"D 2"
Ø5.88
[Ø149.4]
INLET
Ø2.60 "D1"
[Ø66.0]
MOTOR VENTING
2.40
[61.0]
1
2 3 45°
4 5 Ø.17 HOLE THRU,
CL [Ø4.3]
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40 BOLT CIRCLE
[Ø162.6] 1.04 "A"
[26.4]
26° 33° 90°
49° 1.00 3.2 (2X)
[25.4] [81]
MOTOR 3X Ø.17 HOLES THRU,
"A" VENTING
[Ø4.3]
LOCATED AS SHOWN ON A
4.66 "L" Ø6.50 BOLT CIRCLE
[118.4] [Ø165.10]
ACCESS TO
SPEED CONTROL/
CALIBRATION
1.38
[35.1]
2.79
[70.9]
3.29
[83.6]
VIEW "A"
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 25
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System
Typical Performance
150414, 150444
150415, 150445
150416, 150446
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
11
Current (A)
5
Speed (RPM)
500
Power Demand
450
(Watts)
400
350
300
250
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
.45
[11.4]
20°
3.74
DISCHARGE [95.0]
Ø1.75
[Ø44.4]
3.38±.08
[85.9±2.0]
INLET
Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
150417, 150447
150429, 150461
150418, 150448
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
10
9
Current (A)
8
7
6
Speed (RPM)
450
Power Demand
400
(Watts)
350
300
250
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
.45
[11.4]
20°
3.74
DISCHARGE [95.0]
Ø1.75
[Ø44.4]
3.38±.08
[85.9±2.0]
INLET
Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
150419, 150449
150420, 150450
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
12
10
Current (A)
4
2
16500
15400
Speed (RPM)
14300
13200
12100
11000
370
Power Demand
325
(Watts)
280
235
190
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
DISCHARGE Ø1.75
[Ø44.4]
Ø5.88
[Ø149.4]
INLET
Ø2.60 Ø1.75
[Ø66.0] [Ø44.4]
MOTOR VENTING
2.40
[61.0]
12
34 45°
CL 5 Ø.17
[Ø4.3]HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40
[Ø162.6]BOLT CIRCLE 1.04 .88
[26.4] [22.4]
49° 26° 33° 90°
1.00 3.2 (2X)
[25.4] [81] Ø.17 HOLES THRU,
MOTOR 3X [Ø4.3]
"A" VENTING LOCATED AS SHOWN ON A
4.66 "L" Ø6.50
[118.4] [Ø165.10] BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION
(1.38)
([35.1])
2.79
[70.9]
3.29
[83.6]
VIEW "A"
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of
the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
108
96 150421, 150451
84 150422, 150452
Pressure (inch H2O)
150423, 150453
Pressure (mbar)
72
60
48
36
24
12
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 32
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
72 VDC Input, High Flow System
3.74
INCH [95.0]
[MM]
DISCHARGE
"D2"
Ø5.88
[Ø149.4]
INLET
Ø2.60 "D1"
[Ø66.0]
MOTOR VENTING
2.40
1
[61.0]
2 3 45°
4 5 Ø.17
CL [Ø4.3] HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40
[Ø162.6] BOLT CIRCLE 1.04 "A"
[26.4]
26° 33° 90°
49° 1.00 3.2 (2X)
[25.4] [81] Ø.17
MOTOR 3X [Ø4.3]HOLES THRU,
"A" VENTING LOCATED AS SHOWN ON A
4.66 "L" Ø6.50
[118.4] [Ø165.10]BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION
1.38
[35.1]
2.79
[70.9]
3.29
[83.6]
VIEW "A"
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity pontentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 33
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
72 VDC Input, High Flow System
Typical Performance
150424, 150454
150425, 150455
150426, 150456
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
.45
[11.4]
20°
3.74
DISCHARGE [95.0]
Ø1.75
[Ø44.4]
3.38±.08
[85.9±2.0]
INLET
Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
150427, 150457
150428, 150462
150428, 150458
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
.45
[11.4]
20°
3.74
DISCHARGE [95.0]
Ø1.75
[Ø44.4]
3.38±.08
[85.9±2.0]
INLET
Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
150429, 150459
150430, 150460
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Blower Selection
Blower Selection offers a wide variety of standard products available from AMETEK. Nine differ-
ent blower families are available in standard configurations. These include low voltage and high
voltage product lines. The low voltage products provide output pressure up to 97.7” H2O and
flows up to 160.3 CFM. The high voltage products provide outputs up to 169” H2O/420 mbar
(pressure) and flows up to 1100 CFM/1869 m3/hr.
INCH
ISOLATED SPEED
CONTROL
{ HIGH
{
NEUTRAL AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
0-10V DC LINE 108V-132V LINE
[MM] LOW 108V-132V
INPUT REQUIRED PIN NOT USED PIN NOT USED
ACCESS TO
SPEED CONTROL/ DETAIL "E" DETAIL "M"
CALIBRATION (ELECTRICAL) (MECHANICAL)
1.15 POWER/CONTROL CONNECTION DETAILS
[29.2]
ACCESS TO PRESSURE TAP
CL POST HEADER OPTION
Ø1.25 3.74
29° [Ø31.8] [95.0]
DISCHARGE
66°
CL
SPEED CONTROL/ INLET Ø5.90 2.37
CALIBRATION [60.2]
[Ø150.0]
MAX. 3X 90°
Ø1.25
[Ø31.8]
1.43 .75
3X Ø.23 HOLES [36.3] [19.1] 33°
[Ø5.8] "l"
.37 45°
[9.4] DEEP MINIMUM "L" EARTH GROUND
EQUALLY SPACED AS SHOWN ON Ø.17 HOLE THRU,
A Ø4.00 BOLT CIRCLE [Ø4.3]
[Ø101.6] LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
116626, 116629
116627, 116630
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
ISOLATED SPEED
CONTROL
{ HIGH NEUTRAL
LINE
{ AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
0-10V DC LOW 108V-132V LINE 108V-132V
INCH INPUT REQUIRED PIN NOT USED
[MM] PIN NOT USED
Ø1.75
66° [Ø44.5]
C
L
SPEED CONTROL/ INLET 2.12
CALIBRATION [53.8]
Ø5.90
[Ø150.0] 3X 90°
Ø1.75
[Ø44.5] MAX.
1.43 .75
Ø.23 HOLES [36.3] [19.1] 33°
3X [Ø5.8]
.37 DEEP MINIMUM "l" 45°
[9.4]
EQUALLY SPACED AS SHOWN ON "L" EARTH GROUND
Ø.17 HOLE THRU,
Ø4.00 BOLT CIRCLE
A [Ø101.6] [Ø4.3]
LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
116644, 116647
116645, 116648
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
INCH
[MM]
INLET 2.12
[53.8]
3X 90°
Ø1.75 5.90
[Ø44.5] [ 150.0]
MAX. Ø.17 HOLES THRU,
4X[Ø4.3]
LOCATED AS SHOWN ON
37° Ø6.50 BOLT CIRCLE
NC
R EAS
E
[Ø165.10]
I
45°
EARTH GROUND
Ø.17
CL [Ø4.3] HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON
Ø1.3 MAX. CALIBRATION 1.04 .75 Ø6.40 BOLT CIRCLE
[Ø33.0] [26.4] [19.1] [Ø162.6]
MOTOR COOLING 33°
INLET ACCESS TO SPEED CONTROL/
CALIBRATION
NEUTRAL
{ AC INPUT
VOLTAGE
NEUTRAL
{ AC INPUT
VOLTAGE
"I" LINE 108V-132V LINE 108V-132V
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
116637, 116643
116636, 116642
Pressure (inch H2O)
116635, 116641
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
INCH
[MM]
INLET 2.37
[60.2]
Ø5.90 3X 90°
Ø1.25 [Ø150.0]
[Ø31.8] Ø.17 HOLES THRU,
MAX. 4X [Ø4.3]
LOCATED AS SHOWN ON
37° Ø6.50
NC
R EA S
[Ø165.10]BOLT CIRCLE
E
I
CL
SPEED CONTROL/ EARTH GROUND
Ø1.3 MAX. CALIBRATION 1.04 .75 Ø.17
[Ø33.0] [26.4] [19.1] [Ø4.3] HOLE THRU,
MOTOR COOLING LOCATED AS SHOWN ON 33°
ACCESS TO SPEED CONTROL/ Ø6.40 45°
INLET CALIBRATION [Ø162.6]BOLT CIRCLE
"I"
"L"
{
NEUTRAL AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
LINE 108V-132V LINE 108V-132V
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B7
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt Standard Flow
Typical Performance
Flow (m3/hr)
116634, 116640
116633, 116639
Pressure (inch H2O)
116632, 116638
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
2 GROUND 2 GROUND
3 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE
INCH 216V-264V 216V-264V
[MM] 4 4
5 5
Ø5.90 3X 90°
3X Ø.48 Ø1.25 [Ø150.0]
[Ø12.2] [Ø31.8] MAX.
39° CL
SPEED CONTROL/ Ø.17 HOLES THRU,
4X [Ø4.3]
CALIBRATION
LOCATED AS SHOWN ON
43° ACCESS TO SPEED CONTROL/ Ø6.50
CALIBRATION [Ø165.10] BOLT CIRCLE
Ø1.25
3X Ø.23 HOLES [Ø31.8]
[Ø5.8] "l" .75 33°
[19.1]
.37 45°
[9.4] DEEP MINIMUM
EQUALLY SPACED AS SHOWN ON EARTH GROUND
A Ø4.00 BOLT CIRCLE Ø.17 HOLE THRU,
[Ø101.6] [Ø4.3]
LOCATED AS SHOWN ON
"L" Ø6.40
SEE DETAIL "E" OR "M" [Ø162.6] BOLT CIRCLE
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
117629
Pressure (inch H2O)
Pressure (mbar)
117630
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
PRESSURE TAP
43° DISCHARGE OPTION
MOTOR COOLING 3.74
DISCHARGE [95.0]
Ø1.25
37° [Ø31.8]
INCH
[MM] SEE DETAIL
"E" & "M" 2.37
INLET [60.2]
CL NC
R EAS
E
I
SPEED CONTROL/ 3X 90°
CALIBRATION Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
MAX. 4X Ø.17 HOLES THRU,
[Ø4.3]
2.38 LOCATED AS SHOWN ON
[60.5] Ø6.50 BOLT CIRCLE
[Ø165.10]
Ø1.3 MAX.
[Ø33.0] 1.04 .75 33°
MOTOR COOLING [26.4] [19.1]
INLET 45°
ACCESS TO SPEED CONTROL/ "l"
CALIBRATION EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]
5 4 3 2 1 5 4 3 2 1
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
216V-264V 216V-264V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
117634, 117640
117633, 117639
Pressure (inch H2O)
Pressure (mbar)
117632, 117638
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, WHICH IS: .075 lb./ft3 (29.92” Hg,
Sea Level, 68° F). Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
PRESSURE TAP
43° DISCHARGE OPTION
MOTOR COOLING 3.74
DISCHARGE [95.0]
E
I
SPEED CONTROL/ 3X 90°
Ø1.75
CALIBRATION [Ø44.5] Ø5.90
[Ø150.0]
MAX. 4X Ø.17 HOLES THRU,
[Ø4.3]
2.38 LOCATED AS SHOWN ON
[60.5] Ø6.50 BOLT CIRCLE
[Ø165.10]
Ø1.3 MAX.
[Ø33.0] 1.04 .75 33°
[26.4] [19.1]
MOTOR COOLING
INLET 45°
ACCESS TO SPEED CONTROL/ "l"
CALIBRATION EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6]BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
216V-264V 216V-264V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
117637, 117643
Pressure (inch H2O)
Pressure (mbar)
117636, 117642
117635, 117641
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Ø1.25
[Ø31.8]
INCH 2.37
INLET [60.2]
[MM]
3X 90°
Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40
MOTOR COOLING LOCATED AS SHOWN ON
INLET Ø6.50 BOLT CIRCLE
1 [61.0] [Ø165.10]
2
3
4
CL 5
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
DISCHARGE 33°
[26.4] [19.1]
49° 26° 45°
SEE DETAIL "E" & "M" "l"
EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1
}
LOW ISOLATED SPEED NOT USED
CONTROL
R EA S
NC
E
I
0-10V. D.C.
ACCESS TO SPEED CONTROL/ HIGH INPUT REQUIRED NOT USED
CALIBRATION
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
92V-132V 92V-132V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 92-132 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog input voltage range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
117418, 117417
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
• Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
Option Circuit Connections: Pleaase consult with AMETEK for connection details for all optional and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]
Ø1.75
[Ø44.5]
INCH
[MM] INLET 2.12
[53.8]
3X 90°
Ø1.75
[Ø44.5] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40 MOTOR COOLING LOCATED AS SHOWN ON
[61.0] INLET Ø6.50
12
34 [Ø165.10] BOLT CIRCLE
CL 5
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
DISCHARGE [19.1] 33°
[26.4]
49° 26° 45°
SEE DETAIL "E" & "M" "l"
EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1
}
REAS
NC
CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
ACCESS TO SPEED CONTROL/ GROUND GROUND
CALIBRATION
AC INPUT VOLTAGE AC INPUT VOLTAGE
92V-132V 92V-132V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 92-132 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog input voltage range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 17
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
800 Watt, 120 Volt High Flow - IntelliGen (TM)
Typical Performance
Flow (m3/hr)
119101, 119102
119103, 119104
Pressure (inch H2O)
Pressure (mbar)
119105
Flow (CFM)
15
Current (A)
12
6
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & I ndustrial Products cooling air filters.
• Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Ø1.25
[Ø31.8]
INCH
[MM] 2.37
INLET [60.2]
3X 90°
Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
Ø2.60 MAX.
[Ø66.0] MAX. Ø.17 HOLES THRU,
4X [Ø4.3]
2.40 MOTOR COOLING
INLET LOCATED AS SHOWN ON
12 [61.0] Ø6.50
34
5 [Ø165.10] BOLT CIRCLE
CL
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
[19.1] 33°
DISCHARGE [26.4]
49° 26° 45°
SEE DETAIL "E" & "M" 2.12 EARTH GROUND
[53.8] Ø.17
6.87 [Ø4.3] HOLE THRU,
[174.5] LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
R EAS
2 GROUND 2 GROUND
NC
E
I
Notes:
• Input Voltage Range: 208-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
117416, 117415
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Ø1.75
[Ø44.5]
INCH
[MM] INLET 2.12
[53.8]
3X 90°
Ø1.75
[Ø44.5] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40 MOTOR COOLING LOCATED AS SHOWN ON
[61.0] INLET Ø6.50 BOLT CIRCLE
1
2
3
4
[Ø165.10]
CL 5
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04
"B" 33°
DISCHARGE [26.4]
49° 26° 45°
SEE DETAIL "E" & "M" "A" EARTH GROUND
Ø.17 HOLE THRU,
[Ø4.3]
"L"
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6]BOLT CIRCLE
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
2 GROUND 2 GROUND
NC
R EA S
3 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE
E
I
208V-264V 208V-264V
4 4
5 5
ACCESS TO SPEED CONTROL/
CALIBRATION
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
119151, 119152
119153, 119154
Pressure (inch H2O)
Pressure (mbar)
119163
119155
Flow (CFM)
13
Current (A)
10
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
Connections:
• All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
14.12±.25
CONNECTOR SPECIFIC (358.6±6.4) CONNECTOR SPECIFIC
2.938±.014
INCH TO BLOWER TYPE (74.63±0.35) TO BLOWER TYPE
(MM)
2.07
LINE
LOAD
(52.6)
Ø .189 THRU
(4.8)
NOTES:
Contact your AMETEK Sales Engineer for updates and more information on
this product.
This document is for informational purposes only and should not be consid-
ered as a binding description of the products and their performance in all
applications. Specific dimensions may change based on wattage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.46
[87.88]
7.46
[189.5]
MAX.
Ø5.68
[Ø144.3]
Ø4.35
[Ø110.5] Ø4.95
[Ø125.7]
Ø1.975 Ø1.975
[Ø50.17] [Ø50.17]
BLOWER INLET BLOWER INLET
ACCESS TO
SPEED SPEED CONTROL/ 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL/ CL CALIBRATION [42.2] KD/H VENTURI HONEYWELL VENTURI
CALIBRATION 5.38
20° [136,7]MAX.
9°
Notes:
• Input Voltage Range: 12 or 24 Volts DC
• Operating Temperature (Ambient Air and Working Air): -25°C to 50°C
• Storage Tempurature: -40°C to 85°C
• Dielectric Testing: 500 Volts AC RMS 50/60 Hz applied for one second between input pins and ground, 1mA leakage maximum.
• Speed Control Methods: 0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed.
Access for speed adjustment located in motor housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constucted of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower
is installed into the final application.
• Micellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER/CONTROL CONNECTION: Stripped wire leads.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
0 117 134 151 168 185 202 219
18 45
15 12V 37.5
24V
Pressure (inch H2O)
12 30
Pressure (mbar)
9 22.5
6 15
3 7.5
0 0
0 25 50 75 100 125 150 175
Flow (CFM)
24
Current (A)
17
10
3
0 25 50 75 100 125 150 175
9000
Speed (RPM)
8000
7000
6000
0 25 50 75 100 125 150 175
350
Power Demand
250
(Watts)
150
50
0 25 50 75 100 125 150 175
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°
30° CL 38° AS E
E
IN C R
CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION CONTROL/ [Ø50.17] [Ø50.17]
CALIBRATION BLOWER INLET BLOWER INLET
MOTOR COOLING
1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
INLET KD/H VENTURI HONEYWELL VENTURI
ACCESS TO SPEED [42.2]
5.45
EARTH GROUND CONTROL/CALIBRATION [138.4] MAX.
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz, single phase.
• input Current: 3 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under FIle E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower constuction to dampen
vibration within the motor. Two piece blower housing assembly sealed with O-ring gaket for combustion applications. Customer is responsible to check for any leakage
once th blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstucted. Motor ventilation air to be free of oils and other foreign
particles (i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
CONTROL CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnessess available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°
30° 38° AS E
CL
E
INCR
CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION CONTROL/ [Ø50.17] [Ø50.17]
CALIBRATION BLOWER INLET BLOWER INLET
MOTOR COOLING
INLET 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
[42.2] KD/H VENTURI HONEYWELL VENTURI
ACCESS TO SPEED 5.45
EARTH GROUND CONTROL/CALIBRATION
MECHANICAL SPEED [138.4] MAX.
COMMAND
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 2 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under FIle E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials.
Blower housing assembly constructed of die cast aluminum. Impeller constucted from hardened aluminum. Rubber isolation mounts built into blower constuction to dampen
vibration within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the
blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
CONTROL CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb./ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.46
[87.88]
7.46
[189.5] Ø5.68
MAX. [Ø144.3]
Ø4.35 Ø4.95
[Ø110.5] [Ø125.7]
Ø1.975 Ø1.975
PWM CONTROL 1.38 [Ø50.17] [Ø50.17]
AVAILABLE [35.1] BLOWER INLET BLOWER INLET
SENSITIVITYCL 4° 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL [42.16] KD/H VENTURI HONEYWELL VENTURI
5.38
28° [136.7] MAX.
EARTH GROUND
Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 3 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
4-20mA speed control available upon request.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Option Card available for Customization
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is
installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350789-1.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 640900-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-30-3055.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 31
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, High Output
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°
30° 38°
CL AS E
E
IN CR
CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION [Ø50.17] [Ø50.17]
CONTROL/
BLOWER INLET BLOWER INLET
CALIBRATION
MOTOR COOLING
INLET 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
ACCESS TO SPEED [42.2] KD/H VENTURI HONEYWELL VENTURI
EARTH GROUND CONTROL/CALIBRATION 5.45
MECHANICAL SPEED [138.4] MAX.
COMMAND
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 6 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is
installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
SPEED CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
24 60
20 50
Pressure (inch H2O)
Pressure (mbar)
16 40
12 30
8 20
4 10
0 0
0 25 50 75 100 125 150 175 200
Flow (CFM)
6
Current (A)
3
0 25 50 75 100 125 150 175 200
10500
9750
Speed (RPM)
9000
8250
7500
0 25 50 75 100 125 150 175 200
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°
30° 38°
CL E
IN CR AS E
CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION CONTROL/ [Ø50.17] [Ø50.17]
CALIBRATION BLOWER INLET BLOWER INLET
MOTOR COOLING
ACCESS TO SPEED INLET 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL/CALIBRATION [42.2] KD/H VENTURI HONEYWELL VENTURI
MECHANICAL SPEED 5.45
EARTH GROUND MAX.
[138.4]
COMMAND
Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 3 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials.
Blower housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen
vibration within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the
blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
SPEED CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 35
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output Enhanced
Typical Performance
Flow (m3/hr)
24 60
20 50
Pressure (inch H2O)
Pressure (mbar)
16 40
12 30
8 20
4 10
0 0
0 25 50 75 100 125 150 175 200
Flow (CFM)
4
Current (A)
1
0 25 50 75 100 125 150 175 200
10500
9750
Speed (RPM)
9000
8250
7500
0 25 50 75 100 125 150 175 200
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
INCH
[MM] FLANGE "B" FLANGE "A" POWER CONNECTION DETAIL USED
W/PWM OR MECHANICAL SPEED CONTROL
4X HOLES Ø.23/[5.8] THRU. 39° 39°
.72
2X [18.3] EQ. SPACED AS SHOWN 4X HOLES Ø .37 THRU.
[9.3] 1
3.27
Ø [83.1] ON A Ø2.80/[71.0]
THRU. SPACED AS SHOWN SPEED CONNECTION DETAIL 3 2
BOLT CIRCLE USING PWM CONTROL OPTION
ON A Ø 3.40 BOLT CIRCLE. NOT USED
[86.4]
2X .11 NEUTRAL
[2.67] 5 4 3 2 1 LINE
1.14 1.14 COMMON
[29.0] 2.97 [29.0]
.07 [75.44] PWM POWER CONNECTION DETAIL USED
[1.9] NOT USED W/0-10VDC SPEED CONTROL
(FLANGE CL OFFSET) 4.17 TACH-OUT
Ø [105.79]
.35 DC VOLTAGE 1 2 3 4 5
[8.9] MAX.
45° 2.20 ISOLATED SPEED LOW (-)
[55.9] CONTROL INPUT HIGH (+)
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST; 0-10VDC
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A NOT USED
2.20 3.07 3.31 3.94 NEUTRAL
[55.9] [78.0] Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
8.04 LINE
[204.22] MAX.
Ø2.60
[Ø66.04] MOTOR COOLING .21 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
PRESSURE TAP
MOTOR COOLING DISCHARGE
BLOWER .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION [5.33] DISCHARGE
INLET 4.72 3.31 3.94
2 Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
2.82 [119.4 ]
[71.1 2 ]
45°
3.46
[87.88]
7.46
[189.5] Ø5.68
MAX. [Ø144.3]
Ø4.35
[Ø110.5] Ø4.95
[Ø125.7]
Ø1.975 Ø1.975
PWM CONTROL 1.38 [Ø50.17] [Ø50.17]
AVAILABLE BLOWER INLET BLOWER INLET
[35.1]
SENSITIVITY CL 4° 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL [42.16] KD/H VENTURI HONEYWELL VENTURI
5.38
28° [136.7] MAX.
EARTH GROUND
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 6.5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1kHz to 10 kHz)
0 to 10 VDC speed control.
4-20mA speed control available.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg.
• Option Card available for Customization
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower housing
assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration within the motor.
Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350789-1.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 640900-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-30-3055.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
50 125
40 100
Pressure (inch H2O)
Pressure (mbar)
30 75
20 50
10 25
0 0
Flow (CFM)
8
Current (A)
15000
13000
Speed (RPM)
11000
9000
7000
600
Power Demand
550
(Watts)
500
450
400
350
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department..
AMETEK DYNAMIC FLUID SOLUTIONS B 38
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.0" (203mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output
POWER CONNECTION
INCH
[MM]
{
AC INPUT NEUTRAL
VOLTAGE LINE SEE POWER/CONTROL
DETAILS
4.50 PINS NOT USED
[114.2]
Ø7.70 MAX. 1.60 BLOWER 17° 53°
Ø8.16 [Ø195.0] [40.51] DISCHARGE
[Ø207.3] Ø2.18
[Ø55.25]I.D.
Ø2.38
[Ø60.33]O.D.
65° C SPEED
L
E CONTROL/
US CALIBRATION
RE
37° 3.00
Ø2.00 [76.2]
[Ø50.8]
OR
BLOWER
INLET
Ø5.68
A IR
[Ø144.3]
RE P
DRAIN HOLE
37° OPTION
ON
T
NO
45°
TI
DO TA
R
DANGE 65° RO
Ø1.3 MAX.
[Ø33.0]
1.13 MOTOR COOLING MOTOR COOLING
5X MOUNTING SLOTS THRU 5X [28.8] DISCHARGE INLET DRAIN HOLE
SPACED AS SHOWN Ø8.7 MAX. 2.85 OPTION
[Ø220.2] [72.3] MAX.
5.75
[146.1] MAX.
Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 2 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Method: Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for the
speed adjustment located in the motor housing.
• Approximate Weight: 4.2 Lbs. / 1.9 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow in non-premix/non-combustion gas applications. Blower housing/cover and impeller assembly constructed of
polypropylene to protect against corrosion.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign
particles, (i.e. breathing quallity air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP MTA 156 series, part no. 643569-2.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lbs./ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED ADJUSTMENT SPEED ADJUSTMENT
INCH 1 2 3 4 5
PWM IN (BLK)
NOT USED
5.50
(139.7) BLUE (COMMON) }
RED (10V DC SIGNAL) SPEED COMMAND
9.80±.05 4.724±.010
TACH-OUT (WHT)
(245±1.27) (120±0.25)
5.25 ±.03 DC VOLTAGE (RED) 2.362 .350
(133.4±0.76) . .38 (60.0) 4X Ø THRU
4X R (8.9)
(9.7)
2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)
5.68
CONTROL Ø
(144.3)
CONNECTION CL
SPEED
POT.CL CL
POWER
(28°) CONNECTION 4.331
Ø
(110)
(43°)
28°±1° 8.70±.05 .138
3.95±.03
(221±1.3) Ø (3.5)
(100.3±0.76)
{INTAKE} 6X 0.56±.03 4.331
MOTOR Ø
.118 (110)
14.00±1.00 COOLING (14.2±0.76)
(3.0)
43°±3° (355.6±25.4) INLET
AIR INTAKE DETAIL
7.60 MAX.
6.50±2.60 (193)
2X INCL. BOW-OUT
(165.1±25.4) GROUND ( )
Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 8.5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15-45 VDC @ 500 Hz-10 kHz, and tachometer output (2 Pulses / Revolution).
Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. THe potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
4-20 mA speed control also available.
• Approximate Weight: 7.8 Lbs. / 3.5 Kg
• Option Card available for Customization
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower constuction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Custome is responsible to check for any leakage once the blower
is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 41
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED ADJUSTMENT SPEED ADJUSTMENT
INCH 1 2 3 4 5
2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)
CONTROL
CONNECTION CL 5.68
Ø
SPEED (144.3)
POT.CL CL
POWER
(28°) CONNECTION 4.331
Ø
(110)
(43°)
8.70±.05 .138
28°±1° 3.95±.03
(221±1.3) Ø (3.5)
MOTOR (100.3±0.76)
COOLING {INTAKE} 6X 0.56±.03 4.331
Ø
INLET .118 (14.2±0.76) (110)
14.00±1.00
8.10 MAX. (3.0)
43°±3° (355.6±25.4)
(205.7)
INCL. BOW-OUT AIR INTAKE DETAIL
6.50±2.60
2X
(165.1±25.4) GROUND ( )
Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 12 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15 - 45 VDC @ 500 Hz - 10 kHz, and tachometer output (2 Pulses /
Revolution). Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located
in motor housing.
4-20mA speed control available.
• Approximate Weight: 9.3 Lbs. / 4.2 Kg
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and CSA C22.2#133 under File LR43448
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to
dampen vibration within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check
for any leakage once the blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other
foreign particles, (i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 43
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
120 Volt AC Input, Single Phase, High Output
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED CONSTANT SPEED ADJUSTMENT
INCH 1 2 3 4 5
2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)
CONTROL 5.68
CONNECTION CL Ø
(144.3)
SPEED C
POT. L C
L
(28°) POWER Ø
4.331
CONNECTION (110)
(43°)
8.70±.05 .138
28°±1° 3.95±.03
(221±1.3) Ø (3.5)
MOTOR (100.3±0.76)
COOLING {INTAKE} 6X 0.56±.03 4.331
Ø
14.00±1.00 INLET .118 (14.2±0.76) (110)
7.60 MAX. (3.0)
43°±3° (355.6±25.4)
(193)
AIR INTAKE DETAIL
INCL. BOW-OUT
6.50±2.60
2X
(165.1±25.4) GROUND ( )
Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15 - 45 VDC @ 500 Hz - 10 kHz, and tachometer outpuT.
(2 Pulses / Revolution). Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor housing.
4-20mA speed control available.
• Approximate Weight: 7.8 Lbs. / 3.5 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and CSA C22.2#133 under File LR43448.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower housing assembly
constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration within the motor. Two piece
blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED ADJUSTMENT SPEED ADJUSTMENT
INCH 1 2 3 4 5
2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)
CONTROL 5.68
CONNECTION CL Ø
SPEEDC (144.3)
POT. L
CL
(28°) POWER 4.331
CONNECTION Ø
(110)
(43°)
8.70±.05 .138
28°±1° 3.95±.03
(221±1.3) Ø (3.5)
MOTOR (100.3±0.76)
COOLING {INTAKE} 6X 0.56±.03 4.331
INLET Ø
.118 (14.2±0.76) (110)
14.00±1.00
8.10 MAX. (3.0)
43°±3° (355.6±25.4)
(205.7)
INCL. BOW-OUT AIR INTAKE DETAIL
6.50±2.60
2X
(165.1±25.4) GROUND ( )
Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 10 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15 - 45 VDC @ 500 Hz - 10 kHz, and tachometer output (2 Pulses / Revolution).
Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor housing.
4-20mA speed control available.
• Approximate Weight: 9.3 Lbs. / 4.2 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and CSA C22.2#133 under File LR43448
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower housing assembly
constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration within the
motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is installed into the final
application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 47
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
240 Volt AC Input, Single Phase, High Output
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
219.96
8.66
12.83 [332.83]
[MM]
8.89 91.95 219.46
INCH 3.62
4X Ø.35 EXHAUST Ø 8.64 BC
110.0
4.33 180.09
2X 7.09
78.65 169.93
3.10 6.69
12.39 [314.73]
COOLING AIR
DISCHARGE
Ø4.95 [Ø125.82]
INLET
Ø7.15 [181.61] ID X .13 [3.30]
.11 [2.79] INLET GROOVE
[6.35]
90.17 66.29 6X M8X1.25 .25
3.55 2.61
222.25
8.75
POWER CONNECTION
PWM CONNECTION
0-10 VDC CONNECTION
Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase or 153 - 187 VDC
• Input Current: 16 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: PWM 15-45 VDC @ 500 Hz - 10 kHz; 0-10 VDC; mechanical (potentiometer); 4 - 20 mA; remote potentiometer
• Approximate Weight: 28 Lbs. / 12.7 Kg
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under
File LR 43448.
• Miscellaneous: Designed to provide variable airflow for low NOx & CO emissions in high efficiency gas-fired combustion systems. Intake and exhaust tubes, all cooling
ducts and vents must not be obstructed. Intake and exaust must be free of grease, oil and foreign particles. Amp housing 350766-1 w/ Amp contacts 350536-1 for power
connection (supplied by customer) and Molex housing 39-01-4050 or 39-01-4051 w/ Molex contacts 39-00-0039 (18 - 24 awg) or 39-00-0078 (16 awg) for speed control
function (supplied by customer). Non-sparking, hardened aluminum impeller.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
110.0
4.33
180.09
2X 7.09
78.65 169.93
3.10 6.69
12.39 [314.73]
COOLING AIR
DISCHARGE
Ø4.95 [Ø125.82]
INLET
Ø7.15 [181.61] ID X .13 [3.30]
.11 [2.79] INLET GROOVE
[6.35]
90.17 66.29 6X M8X1.25 .25
3.55 2.61
222.25
8.75
POWER CONNECTION
PWM CONNECTION
0-10 VDC CONNECTION
Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase or 305 - 373 VDC
• Input Current: 12 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: PWM 15-45 VDC @ 500 Hz - 10 kHz; 0-10 VDC; mechanical (potentiometer); 4 - 20 mA; remote potentiometer
• Approximate Weight: 28 Lbs. / 12.7 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113
under File LR 43448.
• Miscellaneous: Designed to provide variable airflow for low NOx & CO emissions in high efficiency gas-fired combustion systems. Intake and exhaust tubes, all
cooling ducts and vents must not be obstructed. Intake and exaust must be free of grease, oil and foreign particles. Amp housing 350766-1 w/ Amp contacts 350536-1
for power connection (supplied by customer) and Molex housing 39-01-4050 or 39-01-4051 w/ Molex contacts 39-00-0039 (18 - 24 awg) or 39-00-0078 (16 awg) for speed
control function (supplied by customer). Non-sparking, hardened aluminum impeller.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
20
17.5
Pressure (inch H2O)
15
Pressure (mbar)
12.5
10
7.5
5.0
2.5
0
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
1
(4) PWM SIGNAL (4) NOT USED
(1) AC INPUT 15-45V 500-10Khz
VOLTAGE 240 ±10%
(5) SIGNAL GROUND (5) SIGNAL GROUND
91.95
12.83 [332.83]
3.62
8.89 219.46
4X Ø .35 EXHAUST Ø 8.64 BC
COOLING AIR
DISCHARGE
189.73 180.09
7.47 2X 7.09
79.75 169.93
3.14 6.69
180.34 12.39 [314.73]
Ø 7.10
Ø4.95 [Ø125.82]
INLET
Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, three phase, or 305-373 VDC
• Input Current: 10 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: PWM 15-45 VDC @ 500 Hz - 10 kHz; 0-10 VDC; mechanical (potentiometer); 4 - 20 mA; remote potentiometer
• Approximate Weight: 28 Lbs. / 12.7 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Designed to provide variable airflow for low NOx & CO emissions in high efficiency gas-fired combustion systems. Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and
exaust must be free of grease, oil and foreign particles. Amp housing 350766-1 w/ Amp contacts 350536-1 for power connection (supplied by customer) and Molex housing 39-01-4050 or 39-01-4051 w/ Molex contacts
39-00-0039 (18 - 24 awg) or 39-00-0078 (16 awg) for speed control function (supplied by customer). Non-sparking, hardened aluminum impeller.
Mating harnesses available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
20 50
Pressure (inch H2O)
Pressure (mbar)
17.5 44
15 37
12.5 31
10 25
7.5 19
5.0 13
2.5 6
0 125 250 375 500 625 750 875 1000 1125
Flow (CFM)
10
9
Current (A)
8
7
6
5
0 125 250 375 500 625 750 875 1000 1125
11000
10000
Speed (RPM)
9000
8000
7000
6000
0 125 250 375 500 625 750 875 1000 1125
3000
Power Demand
2600
(Watts)
2200
1800
1400
1000
0 125 250 375 500 625 750 875 1000 1125
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
2.83
(71.9)
ROTATION
.70
(17.8)
Ø3.00 (76.2)
Ø11.28
(286.5)
AIR FLOW
1.195 (30.35)
"PULLER"
10.70
(271.8)
NOTES:
• These fans can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 6 lbs.
• 12.0 VDC Input avaliable
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
27.6 VDC
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Ø 14.68
.86 (Ø 372.87)
(21.84)
14.68
2X (372.87)
Ø 3.00±0.01
(Ø 76.20±0.25)
AIR FLOW
PULLER
7.08
2X (179.83)
13.97
(354.84)
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
Pressure (mbar)
27.6 VDC
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Ø.25
4X (Ø6.35] THRU
SPACED AS SHOWN
16.08
5.86 [408.43]
[148.8] 8.08
2X
[205.23]
3.57
[90.7]
16"
.70
[17.8]
16.56
2X [420.62]
Ø3.00
[Ø76.2]
1.195
[30.35]
AIR FLOW
PULLER
Ø16.75
[Ø425.25]
2X 24.00±1.00
[609.6±25.4]
2X 14 GA. (RED: +, BLACK: -)
XLPE, 300V, 125°C
NOTES:
• These fans can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
27.6 VDC
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
15.66
[397.76]
6.46
12.84
[164.1] Ø.25
[326.14] 4X (Ø6.35] THRU
3.50 SPACED AS SHOWN
[88.9]
.70
[17.8]
16.66
[423.16]
Ø3.00
[Ø76.2]
12.84
[326.14]
1.195
AIR FLOW [30.35]
PULLER
24.00±1.00
2X 2X 14 GA. (RED: +, BLACK: -)
[609.6±25.4]
XLPE, 300V, 125°C
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
Pressure (inch H2O)
27.6 VDC
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lbs/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
4X 12.0±1.0
(304.8±25.4) MEASURED
INCH PERPENDICULAR TO MOTOR BODY
(MM) 4X
0.38±0.12
(9.65±3.05)
4.47
(113.54)
2.24
(56.90)
13.86 0.12
5.0
(352.04) (3.05)
(127.0)
4.0 2.10
(101.6) (53.34)
2X OPENING
3.5
(88.9)
8X Ø 0.22 THRU
(Ø 5.59)
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 12.0 VDC (11 to 18 VDC) Performance Recorded at 13.8 VDC.
24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
13.8 VDC
Pressure (inch H2O)
Pressure (mbar)
27.6 VDC
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
4X 12.0±1.0
12.86 (304.8±25.4) MEASURED
INCH (326.64) PERPENDICULAR TO MOTOR BODY
(MM) 2X 4.30 4X
0.38±0.12
(109.22) (9.65±3.05)
2X 5.49
(139.45)
2.35
(59.69)
6.593 0.44
(167.46) 1.968 (11.18) 3.58
Ø.188 (90.93) 2X 2.67
24X (4.77) THRU (49.99) 4.10 (67.82)
1.484 (104.10) 3.84
(37.69) .826 1.219
OPENING (97.54)
(20.98) (30.96) 5.30
(134.62)
1.51
(38.35)
2.301 .889
(58.45) (22.58) 1.642 3.099
(41.71) (78.71)
5.30
(134.62) 2.674 2X 14 GA. (RED: +, BLACK: -)
(REF.) (67.92) 2X 16 GA. (YELLOW & ORANGE)
XLP, 300 V, 125°C
350.01
(13.78)
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 12.0 VDC (11 to 18 VDC) Performance Recorded at 13.8 VDC.
24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 9 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
13.8 VDC
27.6 VDC
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
17.69±0.02 .285
(449.32±0.51) 4X Ø (7.24) THRU, SPACED AS SHOWN INCH
(MM)
2X 2.18±0.02
(55.37±0.51)
2X 3.20
(81.28)
4.17
2X (161.04)
2.81
4X (71.37)
3.10
2X (78.74)
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 12.0 VDC (11 to 18 VDC) Performance Recorded at 13.8 VDC.
24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 10 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (m3/hr)
13.8 VDC
27.6 VDC
Pressure (mbar)
Pressure (inch H2O)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
CAUTION
150163-11 150163-21 5.14±.06
(12:00 BLAST) (3:00 BLAST) (130.56±1.52)
Ø 1.36 Ø 3.27
(Ø 34.54) (Ø 83.06)
2.38
(60.45)
.58
150163-31 150163-41 (14.73)
(6:00 BLAST) (9:00 BLAST)
3.00±.02 .36
(76.20±0.51) (9.14)
NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for medium duty harsh environment applications such as shuttle bus and other medium duty transit bus applications.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibrations associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brush motor is removable from the pump without draining the coolant system.
• Approximate typical weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (L/min)
Head (meters)
Head (Feet)
Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
INCH
(MM)
.81
Ø[20.62] .38±.12 2X 14 GA. (RED: +, BLACK: -)
1.29±.01 2.02
4X[51.3] .06 4.73 2.75 2X[9.65±3.05] XLPE, 300V, 125°C
[32.77±0.25] [1.52] [120.14] [69.85] MIN. SEE LEAD DESIGNATION
.75
Ø[19.05] SEPARATION POINT
OUTLET .84
.88 Ø[21.34] MOTOR ENDCAP
[22.35] 2X 304.8±25.4
[12.00±1.00]
CAUTION
5.62±.06
[142.75±1.52]
Ø3.00±.01
[Ø76.20±0.25]
2.24
[56.90]
NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for medium duty harsh environment applications such as shuttle bus and other meduim duty transit bus applications.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.
• Approximate typical weight: 8 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (L/min)
Head (Feet)
Head (meters)
Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
IN CONNECTOR WEATHERPACK
(MM) PACKARD NO. 12010973
OR EQUIVALENT
12.0±1.0
4.62 6.0 (304.8±25.4)
4X 3/8-16 UNC-2B X 0.50 DEEP (117.4) (152.4) B A
EQUALLY SPACED AS SHOWN 4X
2.74 1.00 CORRUGATED
ON A Ø 2.312 BOLT CIRCLE LOOM
N (69.6) (25.4) STAMPING DATA
T IO
TA
O
R
3.50±0.03
Ø 3.094 (88.90±0.8)
(Ø 78.59) (MOTOR
FLATS)
1.48±0.10
2.44 (37.6±2.5)
4X (62.0)
2.312
(58.73)
NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for heavy duty harsh environment applications such as heavy duty transit bus applications.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.
• Approximate typical weight: 15 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (L/min)
27.6 VDC
Head (meters)
13.8 VDC
Head (Feet)
Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Ø 1.25 2.13
(Ø 31.75) INLET (54.1) 4.60±0.60
Ø 3.094 (116.84±1.52) 4.25 5.68
(Ø 78.59) OVER FLATS (107.95) (144.27)
3.00
(76.2)
0.93
(23.6) 0.47
2.44 .14 (11.94) 0.25
4X (61.98) 2X 3.68 4X R (6.35)
(3.6) 2.64 1.40
Ø 5.25 (67.1) (35.56) (93.47)
(Ø 133.35) 0.38 DEEP
2X 3/8-16 UNC-2B X (9.65)
4.51 6.43
(114.6) (171.7)
2.312
(58.72)
0.38 Ø 0.88
2X R (9.65) (Ø 22.35) OUTLET
1.35
(34.29)
150198-11 150198-21 150198-31 150198-41 1.81
(12:00 BLAST) (3:00 BLAST) (6:00 BLAST) (9:00 BLAST)
(45.97)
NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for heavy duty harsh environment applications such as heavy duty transit bus applicatio0ns.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.
• Approximate typical weight: 25 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Typical Performance
Flow (L/min)
27.6 VDC
Head (meters)
Head (Feet)
Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Motors and blowers that require low voltage DC input (11 to 52 volts) that do not come equipped
wit an integrated, onboard controller, require on of the external controllers described in this
section.
® ®
INCH
3.65±.01
(MM) (92.7±0.25) J1-1 Vin
1.70 MAX. J1-2 Vin Return (Gnd)
(43.2) J1-3 Analog Speed In
3.338±.015
1.00 2X .156±.010 (84.79±0.38)
(4±0.25)
(25.4) J4-1 Motor Phase A
MAX. MOLEX .156” PITCH RIGHT ANGLE
J4-2 Motor Phase C
FRICTION LOCK HEADER, SQUARE PIN
J4-3 Hall - (Gnd)
3 CIRCUIT SEE CHART (J1) 2X .53±.01
(13.5±0.25) J4-4 Hall 1
MATES WITH AMP TERMINAL HOUSING
J1 J4-5 Hall 2
770849-3 OR EQUIVALENT
J4-6 Hall 3
C17
J5 J4-7 Hall + (+12V)
1
1
J4-8 Motor Phase B
2X 2.190±.015
1
MOLEX 70553 SERIES RIGHT ANGLE HEADER (4.83±0.38) J6
J4
LOW PROFILE, SQUARE PIN, .100 CENTERS J9-1 Return (Gnd)
J3 J2
8 CIRCUIT SEE CHART (J4) J9-2 Tach Out
1
1
MATES WITH MOLEX 70066 SERIES G VERSION
3.25±.01
CONNECTOR HOUSING 50-57-9408 OR EQUIVALENT (82.6±0.25)
1
J9
1
NOTES:
• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.
• Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signa l on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved
by adjusting the potentiometer when J6 is in position 1 to 2.
• Current Control: 5 Amp RMS maximum.
Jumper Settings:
J2-Motor Sensor Spacing: 120° electrical spacing with jumper connected (default).
60° electrical spacing with jumper disconnected.
J3-Rotations: Clockwise rotation with jumper connected (default).
Counter-clockwise rotation with jumper disconnected.
Do not change while motor is running or damage will occur.
J5-Input Voltage: Position 1-2 for 16-52 VDC (default).
Position 2-3 for 11-16 VDC.
J6-Speed Control: Position 1-2 for internal speed adjust, via on board potentiometer (default).
Position 2-3 for analog speed input, via 0-5 VDC signal applied to J1 pins 2 and 3.
J9: F out provides a 0-12 VDC square wave to monitor speed
(
F out (Hz) = Motor RPM
120
Motor
Poles )( )
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Pressure Drop
pose. This system resistance is often 3
referred to as backpressure or head
loss. The performance curves shown in
this catalog represent each model’s typ- 2 P = CQ2
ical maximum performance (full speed) P - pressure Drop
Q - flow rate
at a constant input voltage. The perfor-
C - constant for given system
mance curve describes a blower’s abil- 1
ity to deliver flow rate against
backpressure - from zero backpressure
(“open flow”) to completely blocked flow 0
(“sealed”). Since all Ametek BLDC 0 1 2 3
Flow Rate
blowers have adjustable speed control,
any operating point that lies underneath
a given performance curve can be
reached. With knowledge of the de- Figure 2: System and Blower Curves - Identifying the Operating Point
sired operating point, it is then a simple
matter to browse the catalog to identify 5
blowers having performance curves
that exceed the desired operating point.
4
Other factors should then be consid-
ered, which will be discussed hereafter. Blower performance curve
3
System Resistance Curve: A resis- Actual operating point
Pressure
increased if a different operating point is H2O. The blower whose performance is Answer: At full speed, the blower will
needed in a dynamic system. Blowers shown in Figure 3 has been chosen. deliver about 8.8 cfm in this system,
conveniently have very predictable be- What will be the power consumption at whose backpressure is about 7.2 in
havior when it comes to changes in 8 cfm, 6 in H2O? H2O at that flow rate (see Figure 3).
speed. Table 1 summarizes these rela- Since this is delivering too much, the
tionships. speed must be reduced to achieve the
desired operating point.
Gage Pressure vs. Absolute Pressure: Table 1: Fan Laws Related to At full speed, Figure 3 shows the blower
Before proceeding, it’s important at this Changes in Blower Speed speed to be about 19.8 krpm and the
point to note that this tutorial makes refer-
power consumption is 18.3 W. Using
( )
ence to both “absolute pressure” and N2
“gage pressure.” Gage pressure is simply Q2 = Q1 the fan laws shown in Table 1 yields:
the difference above or below atmo- N1
( )
spheric (or barometric) pressure. Abso-
( )
lute pressure is the sum of atmospheric N2 N2
and gage pressures: m2 = m1 8 cfm = 8.8 cfm
N1 19.8 krpm
Pabsolute = Pgage + Patm N2 = 18.0 krpm
( )
2
N2
P2 = P 1
Pressure values stated hereafter are N1
gage values unless otherwise stated. So, the power consumption at the re-
( )
3
N2 duced speed is:
2 = 1
Figure 3 with Example 1 demonstrates N1
how to calculate the power requirement
( )
3
for an operating point that occurs at a Where, N fan rotational speed 18.0 krpm
reduced speed.
m•
mass flow rate 2 = 18.3 W
Q volume flow rate 19.8 krpm
Example 1: P static pressure (gage)
blower power demand
An application calls for air performance
of 8 cfm (ft3/min) at a pressure of 6 inch All other variables constant. 2 = 13.7 W
12 24
11 22
10 20
9 18
8 16
Pressure (in H 2O)
7 14
6 12
5 10
4 8
3 6
blower pressure vs. flow
0 0
0 2 4 6 8 10 12 14 16 18
Flow Rate (cfm )
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
The speed at the desired operating sure, thereby increasing the blower’s
point could also have been found by ability to provide flow against backpres- Table 2: Fan Laws Related to
using the ratio of pressures: sure, but this is not a common practice. Changes in Fluid Density:
( )
the relationships listed in Table 2. Be-
2
cause fluid density is a variable that is 2 = 1
Note: There is some minor error in this independent of the blower, the density 1
calculation because there will likely be must be stated as part of any blower
some small change in motor efficiency
at the different operating point. This
can usually be neglected for estimating
performance specification. In the previ-
ous example, the density was ignored
for simplicity. But the performance
m2 = m1 ( ) 2
1
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
hereafter for calculating the actual spe- reference texts and internet sites) gives Answer:
cific volume, i.e., volume per unit mass a good estimate for typical outdoor am- A) Table 2 shows that the change in
of the air-water vapor mixture. bient conditions as a function of altitude. mass flow rate is a simple ratio of the
3) Dry bulb temperature is simply the The following example demonstrates densities. If the blower speed is main-
temperature measured using a regular how to account for the lower density at tained between the two locations, the
thermometer. high altitude: mass flow rate delivered at sea level will
4) For humidity, the wet bulb tempera- be:
ture can be used directly without having Example 3: An application calls for a
to convert to another type of humidity blower to deliver 50 cfm of air at 30 inch
quantity. As an alternative, relative hu-
midity or humidity ratio can be used.
H2O at an altitude of 7000 ft above sea
level where the average air density is
m2 = 3.10 lb/min
.075 lb/ft3
.062 lb/ft3 ( )
5) Psychrometric charts are plotted at 0.062 lb/ft3, according to the Standard
m2 = 3.75 lb/min
a single barometric pressure which is Atmosphere Table. For the purpose of
noted in the heading of the chart. A selecting a blower from this catalog,
correction is needed to adjust density what operating point should be used? Mass flow rate is directly proportional to
values to the actual barometric pres- Answer: Refer to Table 2. Since vol- a change in speed (Table 1), so to
sure. ume flow rate does not change with maintain 3.1 lb/ft , the speed must be
3
1
Barometric pressure = 28.60 in Hg
( .062 lb/ft )
.075 lb/ft3
Dry bulb temperature = 72 oF
Wet bulb temperature = 65 oF
P2 = 30 inch H2O
3 ( N ) = .827 = 17.3% reduction
N2
1
.075 lb/ft )
( .062 lb/ft3 1 1
2 = 600 W 3
.989(13.64 ft3/lbair) = 13.49 ft3/lbmix 3
2 = 496 W 2 = 1 (.062
.075 lb/ft
lb/ft
) (.827)
3
Finally, correcting this value for the ac- Example 3 continued - Redefining the
tual barometric pressure yields: 2 = .684 1 = 31.6% reduction
problem in terms of mass flow rate: The
application requires a mass flow rate of
13.49 ft3/lbmix (
29.921 in Hg
28.60 in Hg ) 3.1 lb/min of air regardless of altitude.
A) How much must the speed be re- Incompressible Flow: Although the
density of the working fluid is a variable
duced if the application is moved from a
= 14.12 ft3/lbmix location at 7000 ft (.062 lb/ft3) to sea that must be accounted for, in a given
level (.075 lb/ft3)? application the density is assumed to be
= .0708 lbmix/ft3 B) If the speed is not adjusted to com- constant for applications involving the
pensate for the change is density, what blowers herein. In other words, for a
will be the change in volume flow rate given blower in operation the fluid enter-
The density of air varies substan- between the two locations? ing the blower has the same density as
tially with weather and altitude. The C) How much will the power demand the fluid leaving the blower. Another
Standard Atmosphere Table (not in- change? term for this is “incompressible flow.”
cluded herein, but widely available in Density variations are less than one
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
percent for flow speeds less than Mach vapor is not a problem as long as it does THE FAILURE TO OBSERVE THE
= 0.2, which is greater than typical ap- not condense into liquid water inside the FOLLOWING SAFETY PRECAU-
plications for these blowers. blower. TIONS COULD RESULT IN SERIOUS
BODILY INJURY, INCLUDING DEATH
Blower Life: Brushless DC blowers Mechanical Shock: Mechanical IN EXTREME CASES. We recommend
have the advantage of long life com- shock can cause denting of the that adequate instructions and warnings
pared to blowers driven by brush mo- bearing’s rolling elements. This results by the original equipment manufactur-
tors. Since the motor is electronically in unwanted noise and can lead to flak- ers (OEM) include labels setting forth
commutated there are no brushes to ing and pitting inside the bearing. Appli- the precautions listed below to the end
wear out, so the end of life scenario for cations that subject the blower to user.
brushless blowers is normally bearing mechanical shock should be thoroughly The motors and/or blowers must be
failure. tested to ensure adequate life. connected to a proper and effective
Since long life is one of the main ground or mounted in a manner that will
attributes of brushless technology, the Operating point: The amount of back- guarantee electrical isolation and insu-
question “How long will it last?” is com- pressure a blower works against is an- late the user and others from electric
mon. Unfortunately, there is no simple other influencing factor in some blower shock. End product design should not
answer to this question. There are a models. The backpressure results in a rely solely on the primary insulation of
number of factors that influence life, and pressurized blower housing, putting a the motor.
we currently have no way to account for pressure gradient across the adjacent Standard blowers and/or motors
every possible application. The primary bearing. The pressure gradient tends to are not designed to handle volatile or
factors that influence life are: push the grease out and contamination flammable materials through the fan
in. Ametek has implemented design system unless specifically designed.
• temperature features to minimize this effect, and the Passing combustible gases or other
• bearing contamination customer should not be hesitant to op- flammable materials through the fan
• mechanical shock erate at high pressure if the application system could result in leakage which
• operating point calls for it. could cause a fire or explosion.
These products must not be used in
Temperature: The deterioration of Again, blower life is highly applica- an area contaminated by volatile or
bearing grease is directly proportional tion dependent. Customer requests for flammable materials since sparking is
to its temperature. So, the higher the MTTF (Mean Time To Failure) informa- predictable in the normal operation of
temperature, the shorter the bearing tion are difficult to answer. Moreover, the motor and may ignite the volatile
life. There is no hard limit on bearing what constitutes a failure is often open causing a dangerous explosion.
temperature, but just a general rule that to interpretation. For example, there The Technical and Industrial Prod-
cooler is better. There is a point of can be situations where a blower is ucts Division of Ametek, Inc. can supply
diminishing returns that is application delivering air performance as required, specifically designed motors and blow-
dependent - reducing temperature is but it has deteriorated bearings that ers for use in handling combustible
unnecessary if the blower life is ade- produce unacceptable noise for sound- gases or for use in hazardous duty
quate for the application. A rule of critical applications. locations. These specially designed
thumb for Ametek blowers is 45 oC Ametek does conduct an ongoing units should only be used in conjunction
maximum ambient temperature, but this life test program to gather life informa- with combustible gases, which they
can be exceeded under certain circum- tion and to improve the durability of our were specifically designed to handle.
stances. Please consult Ametek engi- blowers. Tests are conducted on blow- The type of gases must be so noted on
neering for applications a high ers that represent all model families. the product label and in the instructions.
temperatures. Ultimately, it is up to the History has shown that Ametek blowers The rotation of the motor shaft, or
customer to determine whether or not a survive beyond 10,000 hours of contin- anything mounted on the shaft, is a
blower can provide adequate life. Thor- uous running in typical applications. It potential source of injury and must be
ough testing is recommended. Also is common for blowers to endure more taken into account in the design of your
keep in mind that extreme temperature than 20,000 hours, and some blowers end product. You must provide the
can cause premature failure of electron- have accumulated 30,000+ hours. But necessary guarding or housing as re-
ics or the motor winding. again, it must be stressed that blower quired by the finished product and you
life is application dependent, and the must indicate to the user the direction of
Bearing Contamination: The introduc- customer is encouraged to conduct a rotation. Do not remove guard as se-
tion of particulate matter increases the life test in-situ under the application’s vere bodily injury may occur to fingers
rolling friction of the bearing, which in- most rigorous conditions. The life val- or appendages.
creases temperature. Particulates also ues mentioned above are not to be Products incorporating vacuum
scar the surface of the bearing race- used as a basis for warranty claims. motors/blowers must be designed so as
ways and balls, which increases pitting to prevent the vacuum or air pressure
and flaking, further exacerbating the Safety Bulletin: In the applica- from being concentrated in a manner
condition. Corrosive gases can react tion of Ametek, Inc. motors and/or blow- that can expose the user to injury by
negatively with grease or cause corro- ers as a component in your product, you coming into contact with any body area,
sion of the steel in the bearings. Liquids must exercise the following minimum such as eyes, ears, mouth, etc.
of any kind should be avoided. Water precautions:
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
Unit Conversions
Density: 1 lbm/ft3 = 16.03 kg/m3
Length: 1 ft = 12 inch = .01602 g/cm3
= .3048 m
= 30.48 cm Energy: 1 ft•lbf = 1.356 J
= .0001894 mile = 1.356 N•m
= .001285 Btu
Volume: 1 ft3 = .02832 m3
= 28.32 L Power: 1 W = .00134 hp
= 7.481 gal = 3.413 Btu/hr
= 550 (ft-lbf)/s
Mass: 1 lbm = .4536 kg
Temperature: T (oR) = T(oF) + 459.7
Force: 1 lbf = 32.174 lbm•ft/s2 = 1.8[T(oC + 273.15]
= 4.448 N = 1.8T(K)
Volume Flow Rate: 1 cfm (ft3/min) = 28.32 L/min Universal Gas Constant, Ru: = 10.73 psia•ft3/(lbmol•oR)
= 1.699 m3/hr = 1545 ft•lbf/(lbmol•oR)
= 8.314 kJ/(kgmol•K)
Pressure: 1 inch H2O = .249 kPa = 8.314 kPa•m3/(kgmol•K)
= 2.49 mbar
= .0361 psi ( l b f /in 2 )
= .0735 inch Hg
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.