Table of Contents

A: Low Voltage Brushless DC Blowers 5.7" (145mm) BLDC Bypass Blower B21
1200 Watt, 240 Volt High Flow - IntelliGen (TM)
3.0" (76mm) BLDC Low-Voltage Blower A1
12/24 VDC EMI Filter B23
120/240 Volt AC
3.0 (76mm) BLDC Low-Voltage Blower A3
12/24 VDC Input, High Output Variable Flow Filters B24
For use with AMETEK Windjammer and Nautilair Blowers
3.3" (84mm) BLDC Low-Voltage Blower A5
12/24 VDC Nautilair (TM) 7.6" (193mm) Variable Speed Blower B25
12/24 VDC Input, Standard Output
4.5" (114mm) BLDC Low-Voltage Blower A7
12/24 VDC Nautilair (TM) 7.6" (193mm) Variable Speed Blower B27
120 Volt AC Input, Single Phase, Standard Output
5.0" (127mm) BLDC Low-Voltage Blower A9
12/24 VDC, Standard Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B29
240 Volt AC Input, Single Phase, Standard Output
5.0" (127mm) BLDC Low-Voltage Blower A11
12/24 VDC, High Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B31
240 Volt AC Input, Single Phase, High Output
5.1" (130mm) BLDC Low-Voltage Blower A13
24 VDC Nautilair (TM) 7.6" (193mm) Variable Speed Blower B33
120 Volt AC Input, Single Phase, Standard Output Enhanced
5.7" (145mm) BLDC Bypass Blower A15
24 VDC Input, Standard Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B35
240 Volt AC Input, Single Phase, Standard Output Enhanced
5.7" (145mm) BLDC Bypass Blower A17
24 VDC Input, High Flow System Nautilair (TM) 7.6" (193mm) Variable Speed Blower B37
120 Volt AC Input, Single Phase, High Output
5.7" (145mm) BLDC Thru Flow Blower A19
24 VDC Input, Standard Flow System Nautilair (TM) 8.0" (203mm) Variable Speed Blower B39
120 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Thru Flow Blower A21
24 VDC Input, High Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B41
120 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Bypass Blower A23
48 VDC Input, Standard Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B43
120 Volt AC Input, Single Phase, High Output
5.7" (145mm) BLDC Bypass Blower A25
48 VDC Input, High Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B45
240 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Thru Flow Blower A27
48 VDC Input, Standard Flow System Nautilair (TM) 8.9" (226mm) Variable Speed Blower B47
240 Volt AC Input, Single Phase, High Output
5.7" (145mm) BLDC Thru Flow Blower A29
48 VDC Input, High Flow System Nautilair (TM) 12.3" (312mm) Variable Speed Blower B49
120 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Bypass Blower A31
72 VDC Input, Standard Flow System Nautilair (TM) 12.3" (312mm) Variable Speed Blower B51
240 Volt AC Input, Single Phase, Standard Output
5.7" (145mm) BLDC Bypass Blower A33
72 VDC Input, High Flow System Nautilair (TM) 12.3" (312mm) Variable Speed Blower B53
240 Volt AC Input, Three Phase, High Output
5.7" (145mm) BLDC Thru Flow Blower A35
72 VDC Input, Standard Flow System C: Brushless DC Fans and Impeller-Style Blowers
5.7" (145mm) BLDC Thru Flow Blower A37 RTP10 12/24 VDC Brushless DC Fan C1
72 VDC Input, High Flow System RTP14 24 VDC Brushless DC Fan C3
B: High Voltage Brushless DC Blowers RTP16 12/24 VDC Brushless DC Fan C5
5.7" (145mm) BLDC Thru Flow Blower B1 RTP16S 12/24 VDC Brushless DC Fan C7
250 Watt, 120 Volt Standard Flow RTP1300 12/24 VDC Brushless DC Impeller Style Blower C9
5.7" (145mm) BLDC Thru Flow Blower B3 RTP1400 12/24 VDC Brushless DC Impeller Style Blower C11
250 Watt, 120 Volt High Flow RTP1600 12/24 VDC Brushless DC Impeller Style Blower C13
5.7" (145mm) BLDC Bypass Blower B5 D: Pumps
250 Watt, 120 Volt High Flow 10 Gallon Seal-less Pump, Brush Motor D1
5.7" (145mm) BLDC Bypass Blower B7 12 Gallon Seal-less Pump, Brushless Motor D3
250 Watt, 120 Volt Standard Flow 18 Gallon Seal-less Pump, Brushless Motor D5
5.7" (145mm) BLDC Thru Flow Blower B9 26 Gallon Seal-less Pump, Brushless Motor D7
400 Watt, 240 Volt Standard Flow
E: Controllers
5.7" (145mm) BLDC Bypass Blower B11 5 Amp BLDC Blower Controller E1
400 Watt, 240 Volt Standard Flow
5.7" (145mm) BLDC Bypass Blower B13
F: Blower Application Basics
400 Watt, 240 Volt High Flow
5.7" (145mm) BLDC Bypass Blower B15
800 Watt,120 Volt Standard Flow - IntelliGen(TM)
5.7" (145mm) BLDC Bypass Blower B17
800 Watt, 120 Volt High Flow - IntelliGen (TM)
5.7" (145mm) BLDC Bypass Blower B19
1200 Watt, 240 Volt Standard Flow - IntelliGen (TM)

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
www.ametektip.com PRECISION MOTION CONTROL
Low Voltage Brushless DC Blowers
Low Voltage Brushless DC Blowers offer variable output for a wide range of vacuum or pressure
applications. Standard blower designs offer brushless DC motor drives coupled to high efficiency
fan systems in compact, cost effective packages. Standard models are available in a wide range
of input voltages. AMETEK Brushless DC Blowers are not designed for, and should not be used
in, life sustaining applications. AMETEK Brushless DC Blowers are not 100% sealed and there-
fore should not be used with flammable or hazardous gases.

Blower Selection
Blower Selection offers a wide variety of standard products available from AMETEK. Multiple
blower families are available in standard configurations. These include low voltage and high
voltage product lines. The low voltage products provide output pressure up to 97.7” H2O and
flows up to 160.3 CFM. The high voltage products provide outputs up to 169” H2O/420 mbar
(pressure) and flows up to 1100 CFM/1869 m3/hr.

® ®

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
www.ametektip.com PRECISION MOTION CONTROL
Low Voltage Brushless DC Blowers
General Information

AMETEK Windjammer Low Voltage Brushless DC blowers offer a wide range of performance for applications with power
supplies of 72 VDC and less. The following pages detail each model family, including performance, size, and input volt-
age.

All brushless DC blowers require an electronic controller for operation. Most of the model families herein are offered with
an onboard controller, and there are features and/or options available for customization.

Speed Control: Among the low voltage model families there are several methods for modulating blower speed.
Potentiometer Adjustment
ply adjusting a potentiometer on the side of the blower.
Analog Speed Command Signal
particular model, the range of the command signal is either 0-4V, 0-5V, or adjustable within 0-10V.
(i) For 5.0 inch Windjammer models equipped with analog speed command, blowers operate on a 0-4V com-
mand signal. Maximum speed is reached at 4V or less depending on the blower’s operating point. The speed com-
mand pin may by connected to the blower’s 12V or 24V Vin pin to ensure full speed.
(ii) The 5.7 inch Windjammer models have a calibration potentiometer that allows the user to set the range over
which the speed command signal operates within a 0-10V range, or to precisely calibrate a group of blowers to the
same speed for a given command voltage and operating condition.
(iii) Blowers designed for one of AMETEK’s low voltage external controllers can be configured to modulate
speed via either a 0-5V analog command signal or potentiometer adjustment as described above.
2-Wire Operation 3.0, 3.3, and 4.5 inch Windjammers operate with a different type of controller than other
model families. These blowers have a simple two-wire configuration. The blower speed is directly proportional to the
supply voltage, and there is no separate speed command signal input. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum specified supply voltage can be achieved by
providing a third wire to power the motor controller separately from the motor winding. This feature is available upon
request. The specification pages for each of these blower models list the supply voltage range.
Note: None of the blowers herein are designed to maintain constant speed if the blower operating point changes.
The speed will change with changing load (the amount of backpressure), even if the speed control remains fixed.

Tachometer Output: A square wave output that is proportional to blower speed comes as a standard feature in the
24VDC 5.7 inch Windjammer models, and it’s an option that is available in the 3.0, 3.3, and 4.5 inch Windjammers. The
output signal is a square wave whose signal is 2x the blowers rotational frequency:

External Controllers: All of the models herein can be configured to operate with a separate external controller, and
AMETEK’s product offering does include several stand-alone controller models. The 5.0 inch Windjammer model family
has standard blower models already configured for external control. The other models (3.0, 3.3, 4.5, and 5.7 inch Wind-
jammers) can be custom ordered to operate with an external controller - please contact an Ametek sales representative to
inquire. Note: the 5.1 inch Windjammer must use an external controller - it is not available with internal controller at this
time.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
General Information

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.

Locked-Rotor and Thermal Protection:


5.7 inch Windjammers All models include locked rotor and thermal protection
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection.
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.

Other Features and Miscellaneous Notes:


5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
3.0" (76mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
3.42
INCH
5.7 Bypass or Thru
[86.8] Flow: The 5.7 inch Windjammer product family offers two flow path configurations:
#20 AWG LEADSBypass or
[MM] Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air
2.00
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configurationØ.63
shortens the package
[50.8]
size but has a narrower range of operation due to thermal limitations of the motor and controller.
[Ø16.0]
DISCHARGE
DISCHARGE
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
5.1 inch Windjammer Locked rotor protection depends on the controller
1.23 being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [31.2]
2.94
[74.7] 5.0 inch Windjammers All models Ø.75 Ø.81
with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends
[Ø19.1] on the controller
[Ø20.6] design. Thermal protection is not available for this model Ø1.75

family. INLET [Ø11.5]

3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
1.31
vised to include a fuse for circuit protection.
Ø1.00 See performance sheets for individual blower models for fuse sizing.
[33.3]
[Ø25.4]
INLET
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
1.24
jammer pages herein for details.
[31.5] .78
5.0 inch Windjammers can be equipped with an external balancing disk for applications with
1.99 tight noise and vibra-
tion constraints.
2.67 Contact AMETEK Sales for inquiries regarding this feature.
[19.8] [50.6]
[67.8]
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
Part/ Model Number
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
Specification mer shares
Unitsa common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the
119349 analog speed
119350
command input is isolated from the power supply input. See pages herein for specifics about each model.
Voltage VDC 6-14 16-28
Stages - 1 1
in. H2O 13.4 14.0
Max Sealed Pressure
mbar 33.4 34.9
CFM 19.8 20.6
Max Open Flow Rate
m3/hr 33.7 35

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 9 oz. / .3 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency
1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbe
beconsidered
consideredas asaabinding
bindingdescription
descriptionof
ofthe
theproducts
productsor
ortheir
theirperformance
performanceininall
allapplications.
applications.TheTheperformance
performancedata
dataon
onthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunder
undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsiblefor
forblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flowflowor
orwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthe
theoperating
operatingenvironment
environmentand
andapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedfor
forand
andshould
shouldnot
notbe
beused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Solutions Sales
department.
department.

AMETEK DYNAMIC FLUID SOLUTIONS A1


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
3.0" (76mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal
Flow (mlimitations
3
/hr) of the motor and controller.
0 3 7 10 14 17 20 24 27 31 34 37
14 36
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection 119349 - 6VDC
12 30
5.1 inch Windjammer Locked rotor protection depends on the controller being119349
used. If -using
14VDCAmetek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 119350 - 16VDC
10 25
119350 - 28VDC
Pressure (inch H2O)

5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external

Pressure (mbar)
controller,
8 locked rotor protection depends on the controller design. Thermal protection is not available for this model
20
family.
3.0,
6 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are15 ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
4 10

Other Features and Miscellaneous Notes:


2 5
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer
0
pages herein for details. 0
5.0 inch
0 Windjammers
2 4 can be equipped
6 8with an external
10 balancing
12 disk
14 for applications
16 18 with tight
20 noise and
22 vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Flow (CFM)
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
3
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)

2
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
1
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
0
0 2 4 6 8 10 12 14 16 18 20 22

25000
Speed (RPM)

20000

15000

10000
0 2 4 6 8 10 12 14 16 18 20 22

40
Power Demand

30
(Watts)

20

10

0
0 2 4 6 8 10 12 14 16 18 20 22

3
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document
This document is is for
for informational
informational purposes
purposes only
only and
and should
should not
not be
be considered
considered asas aa binding
binding description
description of
of the
the products
products or
or their
their performance
performance in in all
all applications.
applications. The
The performance
performance data
data on
on this
this page
page depicts
depicts
typical performance
typical performance under under controlled
controlled laboratory
laboratory conditions.
conditions. AMETEK
AMETEK is is not
not responsible
responsible for
for blowers
blowers driven
driven beyond
beyond factory
factory specified
specified speed,
speed, temperature,
temperature, pressure,
pressure, flow
flow or
or without
without proper
proper alignment.
alignment. Actual
Actual
performance will
performance will vary
vary depending
depending on
on the
the operating
operating environment
environment and
and application.
application. AMETEK
AMETEK products
products are
are not
not designed
designed for
for and
and should
should not
not be
be used
used inin medical
medical life
life support
support applications.
applications. AMETEK
AMETEK reserves
reserves the
the
right to
right to revise
revise its
its products
products without
without notification.
notification. The
The above
above characteristics
characteristics represent
represent standard
standard products.
products. For
For product
product designed
designed to to meet
meet specific
specific applications,
applications, contact
contact AMETEK
AMETEK Dynamic
Dynamic Fluid
Fluid Solutions
Solutions Sales
Sales
department.
department.

AMETEK DYNAMIC FLUID SOLUTIONS A2


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
3.0 (76mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC Input, High Output

INCH 3.06
5.7 Bypass or Thru Flow:
[77,7]
The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
[MM] Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air
1.62
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
[41,2]
size but has a narrower range of operation due to thermalØ.56
limitations of the motor and controller.
[Ø14,2] #20 AWG LEADS
(.38 REF)
DISCHARGE
[9,7]
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal
Ø.85 protection
DISCHARGE [Ø21,6]
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection.
1.24
2.94 5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
[31,5]
[74,7] controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family. Ø1.78
MAX.
[Ø45,2]
3.0, 3.3, and 4.5 inch Windjammers These
INLET models have neither locked rotor nor thermal protection. Users are ad-
1.31 vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
[33,2]
Ø.80
Other Features and Miscellaneous [Ø20,3]Notes:

5.0 inch Windjammers are INLET


available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages1.24herein for details. .78 2.44
[62,0]
5.0 inch Windjammers
[31,5] can be equipped with
[19,8] an external balancing disk for applications with tight noise and vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
2.67
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate
( 3.22 REF) Vin for the controller and the motor, as
[67,8]
mentioned above. This allows very low input voltage on the motor [88,1](low speed) without shutting down the drive
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also,Part/
theModel
analog speed command for 24V 5.7 Windjam-
Number
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
Specification command input is isolated from the power
Units supply input. See pages herein for specifics about each
150908 model.
150918
Voltage VDC 16-28 5-14
Stages - 1 1
in. H2O 24.9 24.9
Max Sealed Pressure
mbar 62 62
CFM 24.6 24.6
Max Open Flow Rate
m3/hr 41.8 41.8

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 9 oz / .3 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency.

1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

This
Thisdocument
documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.TheTheperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typical
typicalperformance
performanceunder undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnot notresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performance
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reservesthe
will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right
righttotorevise
reviseitsitsproducts
productswithout
withoutnotification.
notification.The
Theabove
abovecharacteristics
characteristicsrepresent
representstandard
standardproducts.
products.For
Forproduct
productdesigned
designedtotomeetmeetspecific
specificapplications,
applications,contact
contactAMETEK
AMETEKDynamic
DynamicFluid
FluidSolutions
SolutionsSales
Sales
department.
department.

AMETEK
AMETEK DYNAMIC
DYNAMIC FLUID
FLUID SOLUTIONS
SOLUTIONS A3
100
100 E.
E. Erie
Erie Street,
Street, Kent
Kent OH
OH 44240
44240
USA:
USA: +1+1 215-256-6601
215-256-6601 -- Europe:
Europe: +49
+49 7703
7703 930
930 909
909 -- Asia:
Asia: +86
+86 21
21 5763
5763 1258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
3.0 (76mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC Input, High Output

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
3
Flow (mlimitations
size but has a narrower range of operation due to thermal /hr) of the motor and controller.
0 4 9 13 17 21 25 30 34 38 42 47
28 70
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection 150908 - 16VDC
24 60
5.1 inch Windjammer Locked rotor protection depends on the controller being150908 - 28VDC
used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 150918 - 5VDC
20 50
150918 - 14VDC
Pressure (inch H2O)

Pressure (mbar)
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller,
16 locked rotor protection depends on the controller design. Thermal protection is not available for this model
40
family.
3.0,
12 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are30 ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
8 20

Other Features and Miscellaneous Notes:


4 10
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer
0
pages herein for details. 0
5.0 inch
0 Windjammers
2.5 can be equipped
5.0 7.5 with an external
10 12.5 balancing
15 disk
17.5 for applications
20 with tight
22.5 25 noise and
27.5 vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding
Flow (CFM) this feature.
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
5.5
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)

4
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
2.5
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
1
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5

34000
Speed (RPM)

26000

18000

10000
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5

70
Power Demand

54
(Watts)

38

22

6
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK DYNAMIC FLUID SOLUTIONS A4
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
3.3" (84mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
INCH 4.42
[112.2]
[MM] 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Thru Flow. The Bypass configuration2.87 separates the motor and controller from.78 the working air, #20
whereas the working air
AWG LEADS
[72.8]in a Thru Flow configuration. The Thru
passes over the motor and controller [19.8] Flow configuration shortens the package
DISCHARGE
size but has a narrower range of operation due to thermal limitations of the motor and controller.Ø.54
[Ø13.7]
DISCHARGE
Locked-Rotor and Thermal Protection:
1.40
5.7 inch Windjammers All models include locked rotor and thermal[35.6]
Ø.76 protection
3.29 [Ø19.3] dependsØ.86
[83.6]
5.1 inch Windjammer Locked rotor protection on the controller being used. If using Ametek 48140 con-
[Ø21.8] Ø1.75
troller, locked rotor protection is enabled. No thermal protection. [Ø11.5]
Ø.75 INLET
5.0
1.50
inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
[Ø19.1]
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
[38.1]
family. Ø.50
3.0, 3.3, and 4.5 inch Windjammers [Ø12.7] These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit INLET
1.44 protection. See performance sheets for individual blower models for fuse sizing.
[36.6] .75 1.99
[19.1] [50.6]
2.99
Other Features and Miscellaneous
[76] Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for
Part/ Model applications with tight noise and vibra-
Number
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Specification Units 119497 119498
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
Voltage mentioned VDC above. This allows very low input
6-13 voltage on the motor (low speed) without shutting 16-26
down the drive
Stages electronics.- 1
The controller Vin can be configured to accept a specific supply voltage depending1 on an
in. H2O 26.0 26.0
Max Sealed Pressure application’s needs.
mbar 64.8 64.8
5.7 Windjammers
CFM designed for 48V and 72V
6.6 input do not have an option for tachometer output at7.1
this time. 24V
Max Open Flow Rate
models m3/hr
have a tachometer output as a standard
11.2 feature. Also, the analog speed command for 24V12.1 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 9 oz / .3 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEK DYNAMIC
DYNAMIC FLUID
FLUID SOLUTIONS
SOLUTIONS A5
100
100 E.
E. Erie
Erie Street,
Street, Kent
Kent OH
OH 44240
44240
USA:
USA: +1
+1 215-256-6601
215-256-6601 -- Europe:
Europe: +49
+49 7703
7703 930
930 909
909 -- Asia:
Asia: +86
+86 21
21 5763
5763 1258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
3.3" (84mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal
Flow (mlimitations
3
/hr) of the motor and controller.
0 1.7 3.4 5.1 6.8 8.5 10.2 11.9
30 75
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
25
5.1 inch Windjammer 119498
Locked rotor protection depends on the controller being used.16VDC
62
If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 119498 26VDC
119497 6VDC
Pressure (inch H2O)

20 50
5.0 inch Windjammers All models with on-board controllers include locked rotor protection.
13VDC If using an external

Pressure (mbar)
119497
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
15 37
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
10 25

Other Features
5 and Miscellaneous Notes: 12.5
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer
0
pages herein for details. 0
5.0 inch
0 Windjammers
1 can be equipped
2 with an3 external balancing
4 disk for applications
5 with
6 tight noise and
7 vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Flow (CFM)
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
3
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)

2
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
1
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
0
0 1 2 3 4 5 6 7

32000
Speed (RPM)

26000

20000

14000
0 1 2 3 4 5 6 7

36
Power Demand

24
(Watts)

12

0
0 1 2 3 4 5 6 7

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A6
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601--Europe:
Europe:+49
+497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
4.5" (114mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC
CL
INCH .24
[MM] 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family .20 offers two flow
[6.1] path configurations: Bypass or
Thru Flow. The Bypass configuration
2.12 separates the motor and controller [5.1]from the working2Xair, 8-32whereas
INSERT the working air
[53.8] .25 MIN THREAD DEPTH
passes over the motor and controller in a Thru Flow configuration.1.03The Thru Flow configuration [6.4] shortens the package
size but has a narrower range of operation due toDISCHARGE [26.2]
thermal limitations of the motor and controller.
.53 x .32
1.53 [13.5 x 8.1]
#20 AWG LEADS
[38.9] DISCHARGE
Locked-Rotor and Thermal Protection:
4.49 1.69
[114.0]5.7 inch Windjammers All models include locked rotor and[43.0]
thermal protection
1.17
Ø.88 [29.7]
5.1 inch Windjammer Locked rotor protection
depends on the controller being used. If using AmetekØ1.75
[Ø22.3] 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [Ø44.4]
INLET
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
2.04
controller,
[51.8]
locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers TheseØ.60
models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. [Ø
See performance sheets for individual blower models for fuse sizing.
15.2]
1.78 INLET .57
[45.2] [14.5]
4.05 .22 1.99
Other Features and Miscellaneous
[102.9] Notes: [5.6] [50.5]
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for
Part/ Model applications with tight noise and vibra-
Number
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Specification Units 119494 119395
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
Voltage mentioned VDC above. This allows very low input
6-14 voltage on the motor (low speed) without shutting 16-28
down the drive
Stages electronics.- 1
The controller Vin can be configured to accept a specific supply voltage depending1 on an
in. H2O 37.1 37.8
Max Sealed Pressure application’s needs.
mbar 92.4 94.2
5.7 Windjammers
CFM designed for 48V and 72V
10.9 input do not have an option for tachometer output at this time. 24V
10.6
Max Open Flow Rate
models m3/hr
have a tachometer output as a standard
18.5 feature. Also, the analog speed command for 24V 18 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
Notes: command input is isolated from the power supply input. See pages herein for specifics about each model.
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Please observe proper polarity for power connections. Improper connections will damage the blower’s electronics.
• Optional - Motor configuration available with connection to external controller.
• Optional - 2-Wire Operation: The 3.0, 3.3, 4.5 inch Windjammers operate with a simple two-wire configuration. The blower speed is directly proportional to
the supply voltage, and there is no separate speed command signal input or speed setting via potentiometer. The supply voltage powers both the motor
winding and the motor controller. Operating points below the minimum supply voltage stated in the chart above can be achieved by providing a third wire to
power the motor controller separately from the motor winding. This feature is available upon request.
• Weight = 13 oz / .4 Kg
Optional Tachometer Output: A square wave output whose signal is 2x the blower rotational frequency.

1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A7
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
4.5" (114mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal
Flow (mlimitations
3
/hr) of the motor and controller.
0 3.4 6.8 10.2 13.6 17 23.8 27.2
60 149
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
50
119494 6VDC 124
5.1 inch Windjammer Locked rotor protection depends on the controller being used.14VDC
119494 If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. 119395 16VDC
Pressure (inch H2O)

40 99
5.0 inch Windjammers All models with on-board controllers include locked rotor
119395protection.
28VDC If using an external

Pressure (mbar)
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
30 74
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.
20 50

Other Features
10 and Miscellaneous Notes: 25
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer
0
pages herein for details. 0
5.0 inch
0 Windjammers
2 can be equipped
4 with an6 external balancing
8 disk for 10
applications with
12 tight noise and
14 vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
Flow (CFM)
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
6
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)

4
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
2
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
0
0 2 4 6 8 10 12 14

30000
Speed (RPM)

24000

18000

12000
0 2 4 6 8 10 12 14

90
Power Demand

60
(Watts)

30

0
0 2 4 6 8 10 12 14

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This
Thisdocument
documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.TheTheperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typical
typicalperformance
performanceunder undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnot notresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performance
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reservesthe
will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right
righttotorevise
reviseitsitsproducts
productswithout
withoutnotification.
notification.The
Theabove
abovecharacteristics
characteristicsrepresent
representstandard
standardproducts.
products.For
Forproduct
productdesigned
designedtotomeetmeetspecific
specificapplications,
applications,contact
contactAMETEK
AMETEKDynamic
DynamicFluid
FluidSolutions
SolutionsSales
Sales
department.
department.

AMETEKDYNAMIC
AMETEK DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A8
100E.
100 E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:+1
USA: +1215-256-6601
215-256-6601--Europe:
Europe:+49
+497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, Standard Flow System
INCH 2.82
[MM] 3X Ø.168 5.7 [71.6]
[Ø4.27] Bypass
x .31/[7.8] DEEP or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
2.50 1.50
Thru Flow.
HOLES EQUALLY
Ø3.228
SPACED The Bypass configuration separates the motor
[63.5] Ø.88 and controller from
[38.1]
the working air, whereas the working air
[Ø82.00]passes over the motor and controller in a Thru Flow [Ø22.4]
BOLT CIRCLE configuration. The Thru Flow configuration shortens the package
DISCHARGE
size but has a narrower range of operation due to thermal limitations .80 of the motor and controller.
[20.3]
Ø3.81
[Ø96.8] 1.27
[32.3]
Locked-Rotor and Thermal Protection: Ø1.50
2.06 [Ø38.1]
5.7 inch Windjammers All models include locked rotor and thermal protection
[52.3] INLET
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [Ø31.8]

5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. OPTIONAL:
Users are ad-
Ø1.25
3X Ø.35 BOSSES
vised to include a fuse for circuit protection. See performance sheets COVER SHELL
[Ø8.9] .21 for individual blower models for fuse
3X
sizing.
WITH INLET TUBE
EQUALLY SPACED ON A [5.3]
Ø3.228 BOLT CIRCLE. Ø5.00
[Ø82.00] [Ø127.0]
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
Part/ Model Number
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
Specification tion constraints.
Units Contact AMETEK Sales
119380 for inquiries regarding
119381 119382 this feature.119383 119384 119385
Voltage 3.0, 3.3, VDC
and 4.5 inch Windjammers
12 can be12configured to have
12 separate Vin for24
the controller and24
the motor, as 24
Stages mentioned- above. This 1allows very low input
1 voltage on the motor
1 (low speed) 1without shutting down
1 the drive 1
Max. Sealed Pressure
electronics.
in. H2O The controller
13.5 Vin can be 13.5
configured to accept
13.5 a specific supply
12.5 voltage depending
12.5 on an 12.5
application’s
mbar needs. 33.6 33.6 33.6 31.1 31.1 31.1
CFM 32.3 32.3 32.3 35.3 35.3 35.3
Max Open Flow Rate
5.7 Windjammers
m3/hr designed
54.9 for 48V and 72V54.9 input do not have
54.9 an option for tachometer
60 output at60this time. 24V 60
Speed Control models have
- a tachometer
Externaloutput asPotent.
a standard
Adjust.feature.
0-4VAlso,
Spd. the
Cmd.analog speed command Potent.
External for 24V 5.7 Windjam-
Adjust. 0-4V Spd. Cmd.
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Models 119380 thru 119385 can be configured and modified for two (2) plane balance option.
• Optional - cover shell with air inlet tube.
• Weight = 1.2 lb / .54 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied to power the blower and the speed is set by adjusting a potentiometer
on the side of the blower.

0-4V Speed Command (0-4V Spd. Cmd.)- Blower speed is proportional to a 0-4V command signal. Maximum speed is reached at 4V or less depending on
the blower’s operating point. The speed command pin may be connected to the blower’s 12V or 24V pin to ensure full speed.

External Control - Designed to operate with an external controller such as AMETEK’s model 48133.

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A9
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, Standard Flow System

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.
Flow (m3/hr)

Locked-Rotor and Thermal Protection:


5.7 inch Windjammers All models include locked rotor and thermal protection
5.1 inch Windjammer Standard
Locked rotor protection depends on the controller being used. If Output - 24VDC
using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. Standard Output - 12VDC
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
Pressure (inch H2O)

controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model

Pressure (mbar)
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.

Other Features and Miscellaneous Notes:


5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
Flow (CFM)
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)

5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 10
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
USA: +1 215-256-6601 -
44240
USA: +1 215-256-6601 - Europe:+49
Europe: +497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258
____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, High Flow System
2.82
INCH [71.6]
3X Ø.168 x .31/[7.8] DEEP
[MM] 5.7 Bypass or Thru Flow:
[Ø4.27]
HOLES EQUALLY SPACED
The 5.72.50
inch Windjammer product family offers1.50 two flow path configurations: Bypass or
Thru
Ø3.228
BOLT
Flow.
CIRCLE
The Bypass configuration[63.5]
separates the motorØ.88 and controller from the working air, whereas the working air
[38.1]
[Ø82.00] [Ø22.4]
passes over the motor and controller in a Thru Flow configuration.
DISCHARGE The Thru Flow configuration shortens the package
.80
size but has a narrower range of operation due to thermal limitations of the motor and controller.
[20.3]
Ø3.81
[Ø96.8] 1.27
[32.3]
Locked-Rotor and Thermal Protection: Ø1.50
2.06 [Ø38.1]
5.7 inch Windjammers All models include locked [52.3]
rotor and thermal protection INLET
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection. [Ø31.8]

5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
OPTIONAL: Ø1.25
3X Ø.35 BOSSES
vised to include a fuse for circuit protection. See performance sheets COVER SHELL
[Ø8.9] .21 for individual blower models for fuse sizing.
3X WITH INLET TUBE
EQUALLY SPACED ON A [5.3]
Ø3.228 BOLT CIRCLE. Ø5.00
[Ø82.00] [Ø127.0]
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
Part/ Model Number
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
Specification tion constraints.
Units Contact AMETEK
150166 Sales for inquiries119375
regarding this feature. 119378 119379
Voltage 3.0, 3.3, VDC
and 4.5 inch Windjammers
12 can be configured to
24have separate Vin for the controller
24 and the motor, as24
Stages mentioned- above. This allows 1 very low input voltage on1the motor (low speed) without
1 shutting down the drive 1
Max. Sealed Pressure
electronics.
in. H2O The controller20.1
Vin can be configured to24.9
accept a specific supply 24.9
voltage depending on an 24.9
application’s
mbar needs. 50.1 62 62 62
CFM 37.7 44.6 44.6 44.6
Max Open Flow Rate
5.7 Windjammers
m3/hr designed64.1
for 48V and 72V input do not
75.8have an option for tachometer
75.8 output at this time. 24V
75.8
Speed Control models have
- a tachometer output
0-4V Spd. as a standard feature.
Cmd. Also, the analog speed
External command
Potent. Adjust. for 24V 5.7 Windjam-
0-4V Spd. Cmd.
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Models 119380 through 119385 can be configured and modified for two (2) plane balance option.
• Optional - cover shell with air inlet tube.
• Weight = 1.2 lb / .54 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied to power the blower and the speed is set by adjusting a potentiometer
on the side of the blower.

0-4V Speed Command (0-4V Spd. Cmd.)- Blower speed is proportional to a 0-4V command signal. Maximum speed is reached at 4V or less depending on
the blower’s operating point. The speed command pin may be connected to the blower’s 12V or 24V pin to ensure full speed.

External Control - Designed to operate with an external controller such as AMETEK’s model 48133.

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 11
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.0" (127mm)
General Information
BLDC Low-Voltage Blower
12/24 VDC, High Flow System

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.

Flow (m3/hr)
Locked-Rotor and Thermal Protection:
5.7 inch Windjammers All models include locked rotor and thermal protection
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection.
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
Pressure (inch H2O)

Pressure (mbar)
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.

Other Features and Miscellaneous Notes:


5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
mentioned above. This allows very low input voltage
Flowon the motor (low speed) without shutting down the drive
(CFM)
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
Current (A)

models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This
Thisdocument
documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.TheTheperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typical
typicalperformance
performanceunder undercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnot notresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performance
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reservesthe
will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right
righttotorevise
reviseitsitsproducts
productswithout
withoutnotification.
notification.The
Theabove
abovecharacteristics
characteristicsrepresent
representstandard
standardproducts.
products.For
Forproduct
productdesigned
designedtotomeetmeetspecific
specificapplications,
applications,contact
contactAMETEK
AMETEKDynamic
DynamicFluid
FluidSolutions
SolutionsSales
Sales
department.
department.

AMETEKDYNAMIC
AMETEK DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 12
100E.
100 E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:+1
USA: +1215-256-6601
215-256-6601- -Europe:
Europe:+49
+497703
7703930
930909
909- -Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.1" (130mm)
General Information
BLDC Low-Voltage Blower
24 VDC
INCH 2.22 2.48 CL
[56,4] [63] .27
[MM]
5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product1.212
family offers two flow
[6,9] 2x path configurations: Bypass or
8-32 INSERT
.25 MIN THREAD DEPTH
Thru Flow. The Bypass configuration separatesDISCHARGE
the motor and controller from the working
[30,78]
[6.4]
air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due
1.71 to thermal limitations of the motor and controller.
.42 x .71
[43,4]
[10,7 x 18]
2.82 DISCHARGE
[71,6] 1.965
Locked-Rotor and Thermal Protection: [49,91]
1.36
[34,5]
5.7 inch Windjammers All models include locked rotor and thermal protection
Ø1.77
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek
[Ø45]48140 con-
troller, locked rotor protection is enabled. Ø.98
No thermal protection. INLET
[Ø24,9]
5.0
2.325inchWindjammers All models with on-board controllers include locked rotor protection. If using an external
[59,06]
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family. Ø.700
[Ø17,78]
#20 AWG LEADS
3.0, 3.3, and 4.5 inch Windjammers INLETThese models have neither locked rotor nor thermal protection. Users are ad-
.31
vised to include a fuse for circuit protection. See performance sheets[7,9]
for individual blower models for fuse sizing.
.72 2.44
[18.3] [62]
Other Features and Miscellaneous Notes:
5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details. Part/ Model Number
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
Specification Units
tion constraints. Contact AMETEK Sales for inquiries regarding this150193
feature.
Voltage
3.0, 3.3, VDC
and 4.5 inch Windjammers can be configured to have separate24
Vin for the controller and the motor, as
Stages - 1
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
in. H2O 50.9
Max Sealed Pressure electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
mbar 126.8
application’s
CFM needs. 26.3
Max Open Flow Rate
m3/hr 44.7
5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
Notes: mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command
• This blower is designed input is
to operate isolated
with from3-phase
an external the power supply
controller input.
such See pages
as AMETEK’s herein
model 48140.for specifics
Speed about
control each
method is amodel.
function of the controller
that drives the blower. If using AMETEK‘s 48140, the controller can be set to control speed by potentiometer adjustment or by 0-5V analog speed command.
Customized controller functions are available - contact AMETEK sales to inquire.
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Product includes a two (2) plane balancing option for reduced vibration.
• Weight = 16 oz / .5 kg

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 13
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
44240
USA:
USA:+1+1215-256-6601
215-256-6601--Europe:
Europe:+49
+497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.1" (130mm)
General Information
BLDC Low-Voltage Blower
24 VDC

5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or
Typical
Thru Flow. The Bypass configuration separates Performance
the motor and controller from the working air, whereas the working air
passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package
size but has a narrower range of operation due to thermal limitations of the motor and controller.
Flow (m3/hr)

Locked-Rotor and Thermal Protection:


5.7 inch Windjammers All models include locked rotor and thermal protection
5.1 inch Windjammer Locked rotor protection depends on the controller being used. If using Ametek 48140 con-
troller, locked rotor protection is enabled. No thermal protection.
5.0 inch Windjammers All models with on-board controllers include locked rotor protection. If using an external
Pressure (inch H2O)

Pressure (mbar)
controller, locked rotor protection depends on the controller design. Thermal protection is not available for this model
family.
3.0, 3.3, and 4.5 inch Windjammers These models have neither locked rotor nor thermal protection. Users are ad-
vised to include a fuse for circuit protection. See performance sheets for individual blower models for fuse sizing.

Other Features and Miscellaneous Notes:


5.0 inch Windjammers are available with inlet tube for connecting a hose to the blower inlet. See 5.0 inch Wind-
jammer pages herein for details.
5.0 inch Windjammers can be equipped with an external balancing disk for applications with tight noise and vibra-
tion constraints. Contact AMETEK Sales for inquiries regarding this feature.
3.0, 3.3, and 4.5 inch Windjammers can be configured to have separate Vin for the controller and the motor, as
Flow (CFM)
mentioned above. This allows very low input voltage on the motor (low speed) without shutting down the drive
electronics. The controller Vin can be configured to accept a specific supply voltage depending on an
application’s needs.
Current (A)

5.7 Windjammers designed for 48V and 72V input do not have an option for tachometer output at this time. 24V
models have a tachometer output as a standard feature. Also, the analog speed command for 24V 5.7 Windjam-
mer shares a common with the 24V supply voltage. For the 48V and 72V 5.7 Windjammers, the analog speed
command input is isolated from the power supply input. See pages herein for specifics about each model.
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

Thisdocument
This documentisisforforinformational
informationalpurposes
purposesonlyonlyand
andshould
shouldnot
notbebeconsidered
consideredasasa abinding
bindingdescription
descriptionofofthe
theproducts
productsorortheir
theirperformance
performanceininallallapplications.
applications.The Theperformance
performancedatadataononthis
thispage
pagedepicts
depicts
typicalperformance
typical performanceunderundercontrolled
controlledlaboratory
laboratoryconditions.
conditions.AMETEK
AMETEKisisnotnotresponsible
responsibleforforblowers
blowersdriven
drivenbeyond
beyondfactory
factoryspecified
specifiedspeed,
speed,temperature,
temperature,pressure,
pressure,flow
flowororwithout
withoutproper
properalignment.
alignment.Actual
Actual
performancewill
performance willvary
varydepending
dependingononthetheoperating
operatingenvironment
environmentandandapplication.
application.AMETEK
AMETEKproducts
productsare
arenot
notdesigned
designedforforand
andshould
shouldnotnotbebeused
usedininmedical
medicallife
lifesupport
supportapplications.
applications.AMETEK
AMETEKreserves
reservesthe
the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales Dynamic Fluid Solutions Sales
department.
department.
AMETEK
AMETEKDYNAMIC
DYNAMICFLUID
FLUIDSOLUTIONS
SOLUTIONS A 14
100
100E.
E.Erie
ErieStreet,
Street,Kent
KentOH
OH44240
USA: +1 215-256-6601 -
44240
USA: +1 215-256-6601 - Europe:+49
Europe: +497703
7703930
930909
909--Asia:
Asia:+86
+8621
215763
57631258
1258
____ PRECISION MOTION CONTROL
www.ametektip.com
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System
INCH 3.74 [95.0]
[MM]

DISCHARGE Ø1.75
[Ø44.4]

Ø5.88
[Ø149.4]
INLET
Ø1.75
[Ø44.4]
Ø2.60
[Ø66.0]
MOTOR VENTING 45°
26° Ø.17HOLE THRU,
[Ø4.3]
CL LOCATED AS SHOWN ON A
SPEED CONTROL/ Ø6.40 1.04 .88
CALIBRATION 33° [Ø162.6] BOLT CIRCLE [26.4] [22.4]
90°
1.00 3.31 (2X)
[25.4] [84.1] Ø.17
MOTOR 3X [Ø4.3] HOLES THRU,
VENTING LOCATED AS SHOWN ON A
49° 4.66 "L"
[118.4] Ø6.50
[Ø165.10] BOLT CIRCLE

ACCESS TO
SPEED CONTROL/
CALIBRATION

4.00
2.79 [101.6]
[70.9]

Part/ Model Number

Specification Units 150400 150431 150401 150432 150402 150433


Stages - 1 1 2 2 3 3
Input Voltage VDC 24 24 24 24 24 24
in. H2O 30 30 56 56 83.4 83.4
Max Sealed Pressure
mbar 74.7 74.7 139.5 139.5 207.7 207.7
CFM 73 73 65 65 66 66
Max Airflow
m3/hr 124.1 124.1 110.5 110.5 112.2 112.2
Inches 0.50 0.50 1.15 1.15 1.84 1.84
Length (L)
mm 12.7 12.7 29.2 29.2 46.7 46.7
Speed Control - Anlg. Spd. Cmd. Potent. Adjust. Anlg. Spd. Cmd. Potent. Adjust. Anlg. Spd. Adjust. Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.

Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.

1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 15


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System

Typical Performance

(at constant 24V input)


Flow (m3/hr)

0 17 34 51 40 68 102 119 136 153

150400, 150431
150401, 150432
150402, 150433
Pressure (inch H2O)

Pressure (mbar)
0 10 20 30 40 50 60 70 80 90
Flow (CFM)

24
20
Current (A)

16
12
8
4
0 10 20 30 40 50 60 70 80 90

20000
Speed (RPM)

18000

16000

14000
0 10 20 30 40 50 60 70 80 90

600
Power Demand

500
(Watts)

400
300
200
100
0 10 20 30 40 50 60 70 80 90

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 16


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System
3.74
INCH
[MM] [95.0]

DISCHARGE
"D2"

Ø5.88
[Ø149.4]
INLET
"D1"
Ø2.60
[Ø66.0]
MOTOR VENTING 45°
26° Ø.17
[Ø4.3] HOLE THRU,
CL LOCATED AS SHOWN ON A
Ø6.40 1.04 "A"
SPEED CONTROL/ 33° [Ø162.6] BOLT CIRCLE [26.4]
90°
CALIBRATION 1.00 3.31 (2X)
[25.4] [84.1] Ø.17
MOTOR 3X [Ø4.3] HOLES THRU,
VENTING LOCATED AS SHOWN ON A
49° 4.66 Ø6.50 BOLT CIRCLE
[118.4] "L" [Ø165.10]

ACCESS TO
SPEED CONTROL/
CALIBRATION

4.00
2.79 [101.6]
[70.9]

Part/ Model Number

Specification Units 150403 150434 150404 150435 150405 150436


Flow - High Flow High Flow High Flow High Flow Ultra High Flow Ultra High Flow
Stages - 1 1 2 2 1 1
Input Voltage VDC 24 24 24 24 24 24
in. H2O 34 34 57 57 22 22
Max Sealed Pressure
mbar 84.7 84.7 142 142 54.8 54.8
CFM 126 126 101 101 190 190
Max Open Flow Rate
m3/hr 214.2 214.2 171.7 171.7 323 323
Inches 1.75 1.75 1.75 1.75 2.75 2.75
Inlet Diameter D1
mm 44.5 44.5 44.5 44.5 69.9 69.9
Inches 1.75 1.75 1.75 1.75 2.5 2.5
Discharge Diameter D2
mm 44.5 44.5 44.5 44.5 63.5 63.5
Inches 0.50 0.50 1.50 1.50 0.75 0.75
Length (L)
mm 12.7 12.7 38.1 38.1 19.1 19.1
Speed Control - Anlg. Spd. Cmd. Potent. Adjust. Anlg. Spd. Cmd. Potent. Adjust. Anlg. Spd. Cmd. Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.

Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 17
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System

Typical Performance

(at constant 24V input)


Flow (m3/hr)

150403, 150434
150404, 150435
Pressure (inch H2O)

150405, 150436

Pressure (mbar)
Flow (CFM)

27
24
Current (A)

21
19
16
13
10
7
Speed (RPM)

700
Power Demand

575
(Watts)

450

325

200

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 18


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
24 VDC Input, Standard Flow System
INCH 30°
[MM] 1.47
[37.3]

3.74
DISCHARGE [95.0]
ACCESS TO
SPEED CONTROL/
CALIBRATION Ø1.75
[Ø44.4]

24°
INLET

Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)

Ø.23 x .50 DEEP HOLES Ø.17


3X [Ø5.8] [12.7] [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON A LOCATED AS SHOWN ON A 1.04 .88
Ø4.00 33° Ø6.40 [26.4] [22.4] 90°
[Ø101.6] BOLT CIRCLE [Ø162.6] BOLT CIRCLE (2X)
2.47 "L" Ø.17 HOLES THRU,
[62.7] 3X[Ø4.3]
LOCATED AS SHOWN ON A
Ø6.50
[Ø165.10] BOLT CIRCLE

Part/ Model Number

Specification Units 150406 150437 150407 150438


Stages - 1 1 2 2
Input Voltage VDC 24 24 24 24
in. H2O 37 37 62 62
Max Sealed Pressure
mbar 92.2 92.2 154.4 154.4
CFM 79 79 72 72
Max Open Flow Rate
m3/hr 134.3 134.3 122.4 122.4
Inches .81 .81 1.50 1.50
Length (L)
mm 20.6 20.6 38.1 38.1
Speed Control - Anlg. Spd. Cmd. Potent. Adjust. Anlg. Spd. Cmd. Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.

Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.

1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 19
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
24 VDC Input, Standard Flow System

Typical Performance

(at constant 24V input)


Flow (m3/hr)

150406, 150437
150407, 150438
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 20


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
24 VDC Input, High Flow System
INCH 30°
[MM] 1.47 3.74
[37.3]
[95.0]

DISCHARGE Ø1.75
ACCESS TO [Ø44.4]
SPEED CONTROL/
CALIBRATION

24°
INLET Ø1.75
[Ø44.4]

45°
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2]
(3X)

Ø.23 x .50 DEEP HOLES Ø.17 90°


3X [Ø5.8] [12.7] [Ø4.3] HOLE THRU, (2X)
LOCATED AS SHOWN ON A LOCATED AS SHOWN ON A 1.04 .88 Ø.17 HOLES THRU,
3X [Ø4.3]
Ø4.00 BOLT CIRCLE 33° Ø6.40 [26.4] [22.4]
[Ø101.6] [Ø162.6] BOLT CIRCLE LOCATED AS SHOWN ON A
2.47 "L" Ø6.50 BOLT CIRCLE
[62.7] [Ø165.10]

Part/ Model Number

Specification Units 150409 150439 150410 150440


Stages - 1 1 2 2
Input Voltage VDC 24 24 24 24
in. H2O 33 33 55 55
Max Sealed Pressure
mbar 82.2 82.2 137 137
CFM 123 123 95 95
Max Open Flow Rate
m3/hr 209.1 209.1 161.5 161.5
Inches 0.81 0.81 1.81 1.81
Length (L)
mm 20.6 20.6 46 46
Speed Control - Anlg. Spd. Cmd. Potent. Adjust. Anlg. Spd. Cmd. Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.

Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output sigal is 2x the blower’s rotational frequency.

1 MECH.
TACH-OUTPUT
REVOLUTION

+Vin
12V

COM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 21
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
24 VDC Input, High Flow System

Typical Performance
(at constant 24V input)
Flow (m3/hr)

150409, 150439
150410, 150440
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)

19200

18000
Speed (RPM)

16800

15400

14200

13000
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 22


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System
INCH
3.74
[MM] [95.0]

DISCHARGE
Ø1.75
[Ø44.4]

Ø5.88
[Ø149.4]

INLET
Ø2.60 Ø1.75
[Ø66.0] [Ø44.4]
MOTOR VENTING
2.40
[61.0]
12
34 45°
CL 5 Ø.17
[Ø4.3]HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40
[Ø162.6]BOLT CIRCLE 1.04 .88
[26.4] [22.4]
49° 26° 33° 90°
1.00 3.2 (2X)
[25.4] [81] Ø.17
3X[Ø4.3] HOLES THRU,
"A" MOTOR
VENTING LOCATED AS SHOWN ON A
4.66 "L" Ø6.50
[118.4] [Ø165.10] BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION

(1.38)
([35.1])
2.79
[70.9]
3.29
[83.6]
VIEW "A"

Part/ Model Number

Specification Units 150411 150441 150412 150442 150413 150443


Stages - 1 1 2 2 3 3
Input Voltage VDC 43-53 43-53 43-53 43-53 43-53 43-53
in. H2O 28.1 28.1 52.7 52.7 79 79
Max Sealed Pressure
mbar 70 70 131.3 131.3 196.8 196.8
CFM 71 71 59 59 64 64
Max Flow Rate
m3/hr 120.7 120.7 100.3 100.3 108.8 108.8
Inches 0.50 0.50 1.15 1.15 1.84 1.84
Length (L)
mm 12.7 12.7 29.2 29.2 46.7 46.7
Speed Control - Analog Potent. Adjust. Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of
the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 23


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System

Typical Performance

(at constant 48V input)


Flow (m3/hr)

150411, 150441
150412, 150442
150413, 150443
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 24


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System
3.74
INCH [95.0]
[MM]

DISCHARGE
"D 2"

Ø5.88
[Ø149.4]

INLET
Ø2.60 "D1"
[Ø66.0]
MOTOR VENTING
2.40
[61.0]
1
2 3 45°
4 5 Ø.17 HOLE THRU,
CL [Ø4.3]
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40 BOLT CIRCLE
[Ø162.6] 1.04 "A"
[26.4]
26° 33° 90°
49° 1.00 3.2 (2X)
[25.4] [81]
MOTOR 3X Ø.17 HOLES THRU,
"A" VENTING
[Ø4.3]
LOCATED AS SHOWN ON A
4.66 "L" Ø6.50 BOLT CIRCLE
[118.4] [Ø165.10]
ACCESS TO
SPEED CONTROL/
CALIBRATION

1.38
[35.1]
2.79
[70.9]

3.29
[83.6]
VIEW "A"

Part/ Model Number

Specification Units 150414 150444 150415 150445 150416 150446


Fan System - High Airflow High Airflow High Airflow High Airflow Ultra High Flow Ultra High Flow
Stages - 1 1 2 2 1 1
Input Voltage VDC 43-53 43-53 43-53 43-53 43-53 43-53
in. H2O 29.5 29.5 51.5 51.5 21.1 21.1
Max Sealed Pressure
mbar 73.5 73.5 128.3 128.3 52.6 52.6
CFM 115.7 115.7 91.3 91.3 160.3 160.3
Max Airflow
m3/hr 196.7 196.7 155.2 155.2 272.5 272.5
Inches 1.75 1.75 1.75 1.75 2.75 2.75
Inlet Diameter D1
mm 44.5 44.5 44.5 44.5 69.9 69.9
Inches 1.75 1.75 1.75 1.75 2.50 2.50
Discharge Diameter D2
mm 44.5 44.5 44.5 44.5 63.5 63.5
Inches 0.50 0.50 1.50 1.50 0.75 0.75
Length (L)
mm 12.7 12.7 38.1 38.1 19.1 19.1
Speed Control - Analog Spd. Cmd. Potent. Adjust. Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 25
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System

Typical Performance

(at constant 48V input)


Flow (m3/hr)

150414, 150444
150415, 150445
150416, 150446
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)

11
Current (A)

5
Speed (RPM)

500
Power Demand

450
(Watts)

400
350
300
250

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 26


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
48 VDC Input, High Flow System
INCH
[MM]

.45
[11.4]

20°
3.74
DISCHARGE [95.0]

Ø1.75
[Ø44.4]

3.38±.08
[85.9±2.0]
INLET

Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)

Ø.23 x .50 DEEP HOLES Ø.17


3X[Ø5.8] [12.7] [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON A LOCATED AS SHOWN ON A 1.04 .88
Ø4.00 Ø6.40 [26.4] [22.4]
[Ø101.6]BOLT CIRCLE
33°
[Ø162.6] BOLT CIRCLE 90°
(2X)
2.47 "L" Ø.17 HOLES THRU,
[62.7] 3X[Ø4.3]
LOCATED AS SHOWN ON A
Ø6.50
[Ø165.10]BOLT CIRCLE

Part/ Model Number

Specification Units 150417 150447 150129 150462 150418 150448


Stages - 1 1 2 2 3 3
Input Voltage VDC 43-53 43-53 43-53 43-53 43-53 43-53
in. H2O 41.5 41.5 71.8 71.8 80 80
Max Sealed Pressure
mbar 103.4 103.4 178.9 178.9 199.3 199.3
CFM 80.5 80.5 65.9 65.9 63 63
Max Flow Rate
m3/hr 136.9 136.9 112 112 107.1 107.1
Inches 0.81 0.81 1.50 1.50 2.17 2.17
Length (L)
mm 20.6 20.6 38.1 38.1 55.1 55.1
Speed Control - Analog Potent. Adjust. Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 27


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
48 VDC Input, Standard Flow System

Typical Performance

(at constant 48V input)


Flow (m3/hr)

150417, 150447
150429, 150461
150418, 150448
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)

10
9
Current (A)

8
7
6
Speed (RPM)

450
Power Demand

400
(Watts)

350

300

250

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 28


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
48 VDC Input, High Flow System
INCH
[MM]

.45
[11.4]

20°
3.74
DISCHARGE [95.0]

Ø1.75
[Ø44.4]

3.38±.08
[85.9±2.0]
INLET

Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)

Ø.23 x .50 DEEP HOLES Ø.17


3X [Ø5.8] [12.7] [Ø4.3]HOLE THRU,
LOCATED AS SHOWN ON A LOCATED AS SHOWN ON A 1.04 .88
Ø4.00 33° Ø6.40 [26.4] [22.4]
[Ø101.6]BOLT CIRCLE [Ø162.6]BOLT CIRCLE 90°
(2X)
2.47 "L" Ø.17 HOLES THRU,
[62.7] 3X[Ø4.3]
LOCATED AS SHOWN ON A
Ø6.50 BOLT CIRCLE
[Ø165.10]

Part/ Model Number

Specification Units 150419 150449 150420 150450


Stages - 1 1 2 2
Input Voltage VDC 43-53 43-53 43-53 43-53
in. H2O 26.0 26.0 53 53
Max Sealed Pressure
mbar 64.8 64.8 132 132
CFM 111.0 111.0 85.9 85.9
Max Flow Rate
m3/hr 188.7 188.7 146 146
Inches .81 .81 1.81 1.81
Length (L)
mm 20.6 20.6 46 46
Speed Control - Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 29


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
48 VDC Input, High Flow System

Typical Performance

(at constant 48V input)


Flow (m3/hr)

150419, 150449
150420, 150450
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)

12

10
Current (A)

4
2

16500

15400
Speed (RPM)

14300
13200

12100

11000

370
Power Demand

325
(Watts)

280

235

190

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 30


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
72 VDC Input, Standard Flow System
INCH
3.74
[MM] [95.0]

DISCHARGE Ø1.75
[Ø44.4]

Ø5.88
[Ø149.4]

INLET
Ø2.60 Ø1.75
[Ø66.0] [Ø44.4]
MOTOR VENTING
2.40
[61.0]
12
34 45°
CL 5 Ø.17
[Ø4.3]HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40
[Ø162.6]BOLT CIRCLE 1.04 .88
[26.4] [22.4]
49° 26° 33° 90°
1.00 3.2 (2X)
[25.4] [81] Ø.17 HOLES THRU,
MOTOR 3X [Ø4.3]
"A" VENTING LOCATED AS SHOWN ON A
4.66 "L" Ø6.50
[118.4] [Ø165.10] BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION

(1.38)
([35.1])
2.79
[70.9]
3.29
[83.6]
VIEW "A"

Part/ Model Number

Specification Units 150421 150451 150422 150454 150423 150453


Stages - 1 1 2 2 3 3
Input Voltage VDC 64-79 64-79 64-79 64-79 64-79 64-79
in. H2O 39.3 39.3 83.6 83.6 88.3 88.3
Max Sealed Pressure
mbar 97.9 97.9 208.2 208.2 220 220
CFM 82 82 65.2 65.2 56.4 56.4
Max Flow Rate
m3/hr 139.4 139.4 110.8 110.8 95.9 95.9
Inches 0.50 0.50 1.15 1.15 1.84 1.84
Length (L)
mm 12.7 12.7 29.2 29.2 46.7 46.7
Speed Control - Analog Potent. Adjust. Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of
the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 31


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
72 VDC Input, Standard Flow System

Typical Performance

(at constant 72V input)


Flow (m3/hr)

108

96 150421, 150451
84 150422, 150452
Pressure (inch H2O)

150423, 150453

Pressure (mbar)
72

60

48

36

24

12

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 32
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
72 VDC Input, High Flow System
3.74
INCH [95.0]
[MM]
DISCHARGE
"D2"

Ø5.88
[Ø149.4]

INLET
Ø2.60 "D1"
[Ø66.0]
MOTOR VENTING
2.40
1
[61.0]
2 3 45°
4 5 Ø.17
CL [Ø4.3] HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40
[Ø162.6] BOLT CIRCLE 1.04 "A"
[26.4]
26° 33° 90°
49° 1.00 3.2 (2X)
[25.4] [81] Ø.17
MOTOR 3X [Ø4.3]HOLES THRU,
"A" VENTING LOCATED AS SHOWN ON A
4.66 "L" Ø6.50
[118.4] [Ø165.10]BOLT CIRCLE
ACCESS TO
SPEED CONTROL/
CALIBRATION

1.38
[35.1]
2.79
[70.9]
3.29
[83.6]
VIEW "A"

Part/ Model Number

Specification Units 150424 150454 150425 150455 150426 150456


Fan System - High Flow High Flow High Flow High Flow Ultra High Flow Ultra High Flow
Stages - 1 1 2 2 1 1
Input Voltage VDC 64-79 64-79 64-79 64-79 64-79 64-79
in. H2O 42.7 42.7 59.1 59.1 25 25
Max Sealed Pressure
mbar 106.4 106.4 147.2 147.2 62.3 62.3
CFM 123.6 123.6 93.6 93.6 159.3 159.3
Max Flow Rate
m3/hr 210.1 210.1 159.1 159.1 270.8 270.8
Inches 1.75 1.75 1.75 1.75 2.75 2.75
Inlet Diameter D1
mm 44.5 44.5 44.5 44.5 69.9 69.9
Inches 1.75 1.75 1.75 1.75 2.50 2.50
Discharge Diameter D2
mm 44.5 44.5 44.5 44.5 63.5 63.5
Inches 0.50 0.50 1.50 1.50 0.75 0.75
Length (L)
mm 12.7 12.7 38.1 38.1 19.1 19.1
Speed Control - Analog Spd. Cmd. Potent. Adjust. Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity pontentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS A 33
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
72 VDC Input, High Flow System

Typical Performance

(at constant 72V input)


Flow (m3/hr)

150424, 150454
150425, 150455
150426, 150456
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 34


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
72 VDC Input, Standard Flow System
INCH
[MM]

.45
[11.4]

20°
3.74
DISCHARGE [95.0]

Ø1.75
[Ø44.4]

3.38±.08
[85.9±2.0]
INLET

Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)

Ø.23 x .50 DEEP HOLES Ø.17


3X [Ø5.8] [12.7] [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON A LOCATED AS SHOWN ON A 1.04 .88
Ø4.00 BOLT CIRCLE 33° Ø6.40 [26.4] [22.4]
[Ø101.6] [Ø162.6] BOLT CIRCLE 90°
(2X)
2.47 "L" Ø.17 HOLES THRU,
[62.7] 3X [Ø4.3]
LOCATED AS SHOWN ON A
Ø6.50
[Ø165.10]BOLT CIRCLE

Part/ Model Number

Specification Units 150427 150457 150128 150462 150428 150458


Stages - 1 1 2 2 3 3
Input Voltage VDC 64-79 64-79 64-79 64-79 64-79 64-79
in. H2O 35.8 35.8 72.1 72.1 97.7 97.7
Max Sealed Pressure
mbar 89.2 89.2 179.6 179.6 243.4 243.4
CFM 85.5 85.5 74.7 74.7 63.5 63.5
Max Flow Rate
m3/hr 145.4 145.4 127 127 108 108
Inches 0.81 0.81 1.50 1.5 2.17 2.17
Length (L)
mm 20.6 20.6 38.1 38.1 55.1 55.1
Speed Control - Analog Potent. Adjust. Analog Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 35


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
72 VDC Input, Standard Flow System

Typical Performance

(at constant 72V input)


Flow (m3/hr)

150427, 150457
150428, 150462
150428, 150458
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 36


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
72 VDC Input, High Flow System
INCH
[MM]

.45
[11.4]

20°
3.74
DISCHARGE [95.0]

Ø1.75
[Ø44.4]

3.38±.08
[85.9±2.0]
INLET

Ø1.75
[Ø44.4]
Ø5.88
Ø.48 [Ø149.4]
[Ø12.2] 45°
(3X)

Ø.23 x .50 DEEP HOLES Ø.17


3X[Ø5.8] [12.7] [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON A LOCATED AS SHOWN ON A 1.04 .88
Ø4.00 BOLT CIRCLE Ø6.40 [26.4] [22.4] 90°
[Ø101.6]
33°
[Ø162.6] BOLT CIRCLE (2X)
2.47 "L" Ø.17 HOLES THRU,
[62.7] 3X[Ø4.3]
LOCATED AS SHOWN ON A
Ø6.50
[Ø165.10]BOLT CIRCLE

Part/ Model Number

Specification Units 150429 150459 150430 150460


Stages - 1 1 2 2
Input Voltage VDC 64-79 64-79 64-79 64-79
in. H2O 37.9 37.9 65.8 65.8
Max Sealed Pressure
mbar 94.4 94.4 163.9 163.9
CFM 118.9 118.9 95.2 95.2
Max Flow Rate
m3/hr 202.1 202.1 161.8 161.8
Inches 0.81 0.81 1.81 1.81
Length (L)
mm 20.6 20.6 46 46
Speed Control - Analog Spd. Cmd. Potent. Adjust. Analog Potent. Adjust.

Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg

Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.

Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 37


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
72 VDC Input, High Flow System

Typical Performance

(at constant 72V input)


Flow (m3/hr)

150429, 150459

150430, 150460
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS A 38


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
High Voltage Brushless DC Blowers offer variable output for a wide range of vacuum or pressure
applications. Standard blower designs offer brushless DC motor drives coupled to high efficiency
fan systems in compact, cost effective packages. Standard models are available in a wide range
of input voltages. AMETEK Brushless DC Blowers are not designed for, and should not be used
in, life sustaining applications. AMETEK Brushless DC Blowers are not 100% sealed and there-
fore should not be used with flammable or hazardous gases.

Blower Selection
Blower Selection offers a wide variety of standard products available from AMETEK. Nine differ-
ent blower families are available in standard configurations. These include low voltage and high
voltage product lines. The low voltage products provide output pressure up to 97.7” H2O and
flows up to 160.3 CFM. The high voltage products provide outputs up to 169” H2O/420 mbar
(pressure) and flows up to 1100 CFM/1869 m3/hr.

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
www.ametektip.com
PRECISION MOTION CONTROL
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt Standard Flow

SEE DETAIL "E" OR "M"

INCH
ISOLATED SPEED
CONTROL
{ HIGH
{
NEUTRAL AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
0-10V DC LINE 108V-132V LINE
[MM] LOW 108V-132V
INPUT REQUIRED PIN NOT USED PIN NOT USED
ACCESS TO
SPEED CONTROL/ DETAIL "E" DETAIL "M"
CALIBRATION (ELECTRICAL) (MECHANICAL)
1.15 POWER/CONTROL CONNECTION DETAILS
[29.2]
ACCESS TO PRESSURE TAP
CL POST HEADER OPTION
Ø1.25 3.74
29° [Ø31.8] [95.0]
DISCHARGE

66°
CL
SPEED CONTROL/ INLET Ø5.90 2.37
CALIBRATION [60.2]
[Ø150.0]
MAX. 3X 90°
Ø1.25
[Ø31.8]

Ø.17 HOLES THRU,


4X [Ø4.3]
3X Ø.48 LOCATED AS SHOWN ON
[Ø12.2] Ø6.50
[Ø165.10] BOLT CIRCLE

1.43 .75
3X Ø.23 HOLES [36.3] [19.1] 33°
[Ø5.8] "l"
.37 45°
[9.4] DEEP MINIMUM "L" EARTH GROUND
EQUALLY SPACED AS SHOWN ON Ø.17 HOLE THRU,
A Ø4.00 BOLT CIRCLE [Ø4.3]
[Ø101.6] LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]

Part/ Model Number

Specification Units 116626 116629 116627 116630


Stages - 1 1 2 2
in. H2O 28.4 28.4 50.0 50.0
Max Sealed Vacuum
mbar 70.7 70.7 124.6 124.6
in. H2O 29.3 29.3 50.6 50.6
Max Sealed Pressure
mbar 73 73 126 126
CFM 64.5 64.5 66 66
Max Flow Rate
m3/hr 109.7 109.7 112.2 112.2
Inches 0.69 0.69 1.60 1.60
Length (I)
mm 17.5 17.5 40.6 40.6
Inches 3.16 3.16 4.07 4.07
Length (L)
mm 80.3 80.3 103.4 103.4
Speed Control - Mechanical Electrical Mechanical Electrical

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B1


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt Standard Flow

Typical Performance

Flow (m3/hr)

116626, 116629

116627, 116630
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B2


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt High Flow
SEE DETAIL "E" OR "M"

ISOLATED SPEED
CONTROL
{ HIGH NEUTRAL
LINE
{ AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
0-10V DC LOW 108V-132V LINE 108V-132V
INCH INPUT REQUIRED PIN NOT USED
[MM] PIN NOT USED

ACCESS TO DETAIL "E" DETAIL "M"


SPEED CONTROL/ (ELECTRICAL) (MECHANICAL)
CALIBRATION POWER/CONTROL CONNECTION DETAILS
1.15
[29.2] PRESSURE TAP
CL OPTION
ACCESS TO 3.74
POST HEADER 29° DISCHARGE [95.0]
DISCHARGE

Ø1.75
66° [Ø44.5]
C
L
SPEED CONTROL/ INLET 2.12
CALIBRATION [53.8]
Ø5.90
[Ø150.0] 3X 90°
Ø1.75
[Ø44.5] MAX.

Ø.17 HOLES THRU,


4X [Ø4.3]
Ø.48
3X [Ø12.2] LOCATED AS SHOWN ON
Ø6.50
[Ø165.10] BOLT CIRCLE

1.43 .75
Ø.23 HOLES [36.3] [19.1] 33°
3X [Ø5.8]
.37 DEEP MINIMUM "l" 45°
[9.4]
EQUALLY SPACED AS SHOWN ON "L" EARTH GROUND
Ø.17 HOLE THRU,
Ø4.00 BOLT CIRCLE
A [Ø101.6] [Ø4.3]
LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]

Part/ Model Number

Specification Units 116644 M 116647 E 116645 M 116648 E


Stages - 1 1 2 2
in. H2O 26.5 26.5 46.7 46.7
Max Sealed Vacuum
mbar 66 66 116.3 116.3
in. H2O 27.3 27.3 48.1 48.1
Max Sealed Pressure
mbar 68 68 119.8 119.8
CFM 130.5 130.5 98.2 98.2
Max Flow Rate
m3/hr 221.9 221.9 166.9 166.9
Inches 0.76 0.76 1.81 1.81
Length (I)
mm 19.3 19.3 46 46
Inches 3.23 3.23 4.28 4.28
Length (L)
mm 82 82 108.7 108.7
Speed Control - Mechanical Electrical Mechanical Electrical

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B3


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt High Flow

Typical Performance

Flow (m3/hr)

116644, 116647
116645, 116648
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B4


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt High Flow

SEE DETAIL "E" OR "M" PRESSURE TAP


OPTION
Ø1.75 MOTOR COOLING 3.74
[Ø44.5] DISCHARGE [95.0]
DISCHARGE

INCH
[MM]

INLET 2.12
[53.8]
3X 90°
Ø1.75 5.90
[Ø44.5] [ 150.0]
MAX. Ø.17 HOLES THRU,
4X[Ø4.3]
LOCATED AS SHOWN ON
37° Ø6.50 BOLT CIRCLE
NC
R EAS
E
[Ø165.10]
I

45°
EARTH GROUND
Ø.17
CL [Ø4.3] HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON
Ø1.3 MAX. CALIBRATION 1.04 .75 Ø6.40 BOLT CIRCLE
[Ø33.0] [26.4] [19.1] [Ø162.6]
MOTOR COOLING 33°
INLET ACCESS TO SPEED CONTROL/
CALIBRATION
NEUTRAL
{ AC INPUT
VOLTAGE
NEUTRAL
{ AC INPUT
VOLTAGE
"I" LINE 108V-132V LINE 108V-132V

"L" PIN NOT USED PIN NOT USED


{
HIGH ISOLATED
CONTROL
SPEED
LOW 0-10V DC
INPUT REQUIRED

DETAIL "E" DETAIL "M"


(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 116637 116643 116636 116642 116635 116641


Stages - 1 1 2 2 3 3
in. H2O 25.2 25.2 49.7 49.7 67.2 67.2
Max Sealed Vacuum
mbar 62.8 62.8 123.8 123.8 167.4 167.4
in. H2O 26.0 26.0 51.2 51.2 69.3 69.3
Max Sealed Pressure
mbar 64.8 64.8 127.5 127.5 172.6 172.6
CFM 130.5 130.5 103.9 103.9 82.3 82.3
Max Flow Rate
m3/hr 221.9 221.9 176.6 176.6 139.9 139.9
Inches 0.47 0.47 1.53 1.53 2.53 2.53
Length (I)
mm 11.9 11.9 38.9 38.9 64.3 64.3
Inches 5.22 5.22 6.27 6.27 7.28 7.28
Length (L)
mm 132.6 132.6 159.3 159.3 184.9 184.9
Speed Control - Mechanical Electrical Mechanical Electrical Mechanical Electrical

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B5


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt High Flow

Typical Performance

Flow (m3/hr)

116637, 116643
116636, 116642
Pressure (inch H2O)

116635, 116641

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B6


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt Standard Flow

SEE DETAIL "E" OR "M" PRESSURE TAP


OPTION
Ø1.25 MOTOR COOLING 3.74
[Ø31.8] DISCHARGE [95.0]
DISCHARGE

INCH
[MM]
INLET 2.37
[60.2]

Ø5.90 3X 90°
Ø1.25 [Ø150.0]
[Ø31.8] Ø.17 HOLES THRU,
MAX. 4X [Ø4.3]
LOCATED AS SHOWN ON
37° Ø6.50
NC
R EA S
[Ø165.10]BOLT CIRCLE

E
I

CL
SPEED CONTROL/ EARTH GROUND
Ø1.3 MAX. CALIBRATION 1.04 .75 Ø.17
[Ø33.0] [26.4] [19.1] [Ø4.3] HOLE THRU,
MOTOR COOLING LOCATED AS SHOWN ON 33°
ACCESS TO SPEED CONTROL/ Ø6.40 45°
INLET CALIBRATION [Ø162.6]BOLT CIRCLE
"I"

"L"
{
NEUTRAL AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
LINE 108V-132V LINE 108V-132V

PIN NOT USED PIN NOT USED


{
HIGH ISOLATED
CONTROL
SPEED
LOW 0-10V DC
INPUT REQUIRED

DETAIL "E" DETAIL "M"


(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 116634 116640 116633 116639 116632 116638


Stages - 1 1 2 2 3 3
in. H2O 29.5 29.5 40.1 40.1 78.4 78.4
Max Sealed Vacuum
mbar 73.5 73.5 99.9 99.9 195.3 195.3
in. H2O 30.4 30.4 41.3 41.3 80.5 80.5
Max Sealed Pressure
mbar 75.7 75.7 102.9 102.9 200.5 200.5
CFM 75.9 75.9 65.6 65.6 56.4 56.4
Max Flow Rate
m3/hr 129 129 111.5 111.5 95.9 95.9
Inches 0.33 0.33 1.25 1.25 2.14 2.14
Length (I)
mm 8.4 8.4 31.8 31.8 54.4 54.4
Inches 5.08 5.08 6.35 6.35 6.89 6.89
Length (L)
mm 129 129 161.3 161.3 175 175
Speed Control - Mechanical Electrical Mechanical Electrical Mechanical Electrical

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B7
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt Standard Flow

Typical Performance

Flow (m3/hr)

116634, 116640
116633, 116639
Pressure (inch H2O)

116632, 116638

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B8


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
400 Watt, 240 Volt Standard Flow

}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
2 GROUND 2 GROUND
3 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE
INCH 216V-264V 216V-264V
[MM] 4 4

5 5

DETAIL "E" DETAIL "M"


(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
PRESSURE TAP
1.04 OPTION
3.74
[26.4] [95.0]
DISCHARGE
Ø1.25
[Ø31.8]
2.37
INLET [60.2]

Ø5.90 3X 90°
3X Ø.48 Ø1.25 [Ø150.0]
[Ø12.2] [Ø31.8] MAX.
39° CL
SPEED CONTROL/ Ø.17 HOLES THRU,
4X [Ø4.3]
CALIBRATION
LOCATED AS SHOWN ON
43° ACCESS TO SPEED CONTROL/ Ø6.50
CALIBRATION [Ø165.10] BOLT CIRCLE

Ø1.25
3X Ø.23 HOLES [Ø31.8]
[Ø5.8] "l" .75 33°
[19.1]
.37 45°
[9.4] DEEP MINIMUM
EQUALLY SPACED AS SHOWN ON EARTH GROUND
A Ø4.00 BOLT CIRCLE Ø.17 HOLE THRU,
[Ø101.6] [Ø4.3]
LOCATED AS SHOWN ON
"L" Ø6.40
SEE DETAIL "E" OR "M" [Ø162.6] BOLT CIRCLE

Part/ Model Number

Specification Units 117629 117630


Stages - 1 2
in. H2O 28 47
Max Sealed Vacuum
mbar 69.7 117.1
in. H2O 31 50
Max Sealed Pressure
mbar 77.2 124.6
CFM 67 65
Max Airflow
m3/hr 113.9 110.5
Inches .69 1.6
Length (I)
mm 17.5 40.6
Inches 3.21 4.12
Length (L)
mm 81.5 104.6
Speed Control - Electrical Electrical

Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B9


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
400 Watt, 240 Volt Standard Flow

Typical Performance

Flow (m3/hr)

117629
Pressure (inch H2O)

Pressure (mbar)
117630

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 10


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
400 Watt, 240 Volt Standard Flow

PRESSURE TAP
43° DISCHARGE OPTION
MOTOR COOLING 3.74
DISCHARGE [95.0]

Ø1.25
37° [Ø31.8]
INCH
[MM] SEE DETAIL
"E" & "M" 2.37
INLET [60.2]
CL NC
R EAS

E
I
SPEED CONTROL/ 3X 90°
CALIBRATION Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
MAX. 4X Ø.17 HOLES THRU,
[Ø4.3]
2.38 LOCATED AS SHOWN ON
[60.5] Ø6.50 BOLT CIRCLE
[Ø165.10]

Ø1.3 MAX.
[Ø33.0] 1.04 .75 33°
MOTOR COOLING [26.4] [19.1]
INLET 45°
ACCESS TO SPEED CONTROL/ "l"
CALIBRATION EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]
5 4 3 2 1 5 4 3 2 1

}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
216V-264V 216V-264V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 117634 117640 117633 117639 117632 117638


Stages - 1 1 2 2 3 3
in. H2O 28 28 45 45 60 60
Max Sealed Vacuum
mbar 69.7 69.7 112.1 112.1 149.5 149.5
in. H2O 30 30 51 51 72 72
Max Sealed Pressure
mbar 74.7 74.7 127 127 179.4 179.4
CFM 70 70 67 67 65 65
Max Flow Rate
m3/hr 119 119 113.9 113.9 110.5 110.5
Inches 2.53 2.53 1.25 1.25 2.14 2.14
Length (I)
mm 64.3 64.3 31.8 31.8 54.4 54.4
Inches 5.08 5.08 5.99 5.99 6.89 6.89
Length (L)
mm 129 129 152.1 152.1 175 175
Speed Control - Mechanical Electrical Mechanical Electrical Mechanical Electrical

Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 11


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
400 Watt, 240 Volt Standard Flow

Typical Performance

Flow (m3/hr)

117634, 117640
117633, 117639
Pressure (inch H2O)

Pressure (mbar)
117632, 117638

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, WHICH IS: .075 lb./ft3 (29.92” Hg,
Sea Level, 68° F). Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 12


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
400 Watt, 240 Volt High Flow

PRESSURE TAP
43° DISCHARGE OPTION
MOTOR COOLING 3.74
DISCHARGE [95.0]

INCH 37° Ø1.75


SEE DETAIL [Ø44.5]
[MM]
"E" & "M"
INLET
2.12
CL NC
R EA S
[53.8]

E
I
SPEED CONTROL/ 3X 90°
Ø1.75
CALIBRATION [Ø44.5] Ø5.90
[Ø150.0]
MAX. 4X Ø.17 HOLES THRU,
[Ø4.3]
2.38 LOCATED AS SHOWN ON
[60.5] Ø6.50 BOLT CIRCLE
[Ø165.10]

Ø1.3 MAX.
[Ø33.0] 1.04 .75 33°
[26.4] [19.1]
MOTOR COOLING
INLET 45°
ACCESS TO SPEED CONTROL/ "l"
CALIBRATION EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6]BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1

}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
216V-264V 216V-264V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 117637 117643 117636 117642 117635 117641


Stages - 1 1 2 2 3 3
in. H2O 22 22 39 39 53 53
Max Sealed Vacuum
mbar 54.8 54.8 97.1 97.1 132 132
in. H2O 24 24 45 45 61 61
Max Sealed Pressure
mbar 59.8 59.8 112.1 112.1 152 152
CFM 106 106 95 95 90 90
Max Flow Rate
m3/hr 180.2 180.2 161.5 161.5 153 153
Inches .47 .47 1.53 1.53 2.53 2.53
Length (I)
mm 11.9 11.9 38.9 38.9 64.3 64.3
Inches 5.22 5.22 6.27 6.27 7.28 7.28
Length (L)
mm 132.6 132.6 159.3 159.3 184.9 184.9
Speed Control - Mechanical Electrical Mechanical Electrical Mechanical Electrical

Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 13


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
400 Watt, 240 Volt High Flow

Typical Performance

Flow (m3/hr)

117637, 117643
Pressure (inch H2O)

Pressure (mbar)
117636, 117642
117635, 117641

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 14


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
800 Watt,120 Volt Standard Flow - IntelliGen(TM)
PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]

Ø1.25
[Ø31.8]

INCH 2.37
INLET [60.2]
[MM]
3X 90°
Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40
MOTOR COOLING LOCATED AS SHOWN ON
INLET Ø6.50 BOLT CIRCLE
1 [61.0] [Ø165.10]
2
3
4
CL 5

SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
DISCHARGE 33°
[26.4] [19.1]
49° 26° 45°
SEE DETAIL "E" & "M" "l"
EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1

}
LOW ISOLATED SPEED NOT USED
CONTROL
R EA S
NC
E
I

0-10V. D.C.
ACCESS TO SPEED CONTROL/ HIGH INPUT REQUIRED NOT USED
CALIBRATION
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
92V-132V 92V-132V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 117418 117417


Stages - 3 3
in. H2O 102 102
Max Sealed Vacuum
mbar 254.1 254.1
in. H2O 122 122
Max Sealed Pressure
mbar 303.9 303.9
CFM 76 76
Max Flow Rate
m3/hr 129.2 129.2
Inches 2.12 2.12
Length (I)
mm 53.8 53.8
Inches 6.87 6.87
Length (L)
mm 174.5 174.5
Speed Control - Mechanical Electrical

Notes:
• Input Voltage Range: 92-132 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog input voltage range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 15


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
800 Watt,120 Volt Standard Flow - IntelliGen(TM)

Typical Performance

Flow (m3/hr)

117418, 117417
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
• Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
Option Circuit Connections: Pleaase consult with AMETEK for connection details for all optional and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 16


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
800 Watt, 120 Volt High Flow - IntelliGen (TM)

PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]

Ø1.75
[Ø44.5]
INCH
[MM] INLET 2.12
[53.8]
3X 90°
Ø1.75
[Ø44.5] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40 MOTOR COOLING LOCATED AS SHOWN ON
[61.0] INLET Ø6.50
12
34 [Ø165.10] BOLT CIRCLE
CL 5
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
DISCHARGE [19.1] 33°
[26.4]
49° 26° 45°
SEE DETAIL "E" & "M" "l"
EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1

}
REAS
NC

LOW ISOLATED SPEED NOT USED


E
I

CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
ACCESS TO SPEED CONTROL/ GROUND GROUND
CALIBRATION
AC INPUT VOLTAGE AC INPUT VOLTAGE
92V-132V 92V-132V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 119102 119101 119104 119103 119105


Stages - 1 1 2 2 1
in. H2O 31 31 67 67 24
Max Sealed Vacuum
mbar 77.2 77.2 166.9 166.9 59.8
in. H2O 39 39 78 78 30
Max Sealed Pressure
mbar 97.1 97.1 194.3 194.3 74.7
CFM 140 140 131 131 210
Max Flow Rate
m3/hr 238 238 222.7 222.7 357
Inches 1.75 1.75 1.75 1.75 2.75/2.50
Inlet/Outlet Diameter
mm 44.5 44.5 44.5 44.5 69.9/63.5
Inches .47 .47 1.53 1.53 .71
Length (I)
mm 11.9 11.9 38.9 38.9 18
Inches 5.30 5.30 6.19 6.19 5.46
Length (L)
mm 134.6 134.6 157.2 157.2 138.7
Speed Control - Mechanical Electrical Mechanical Electrical Electrical

Notes:
• Input Voltage Range: 92-132 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog input voltage range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 17
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
800 Watt, 120 Volt High Flow - IntelliGen (TM)

Typical Performance

Flow (m3/hr)

119101, 119102
119103, 119104
Pressure (inch H2O)

Pressure (mbar)
119105

Flow (CFM)
15
Current (A)

12

6
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & I ndustrial Products cooling air filters.
• Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 18


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt Standard Flow - IntelliGen (TM)
PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]

Ø1.25
[Ø31.8]

INCH
[MM] 2.37
INLET [60.2]
3X 90°
Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
Ø2.60 MAX.
[Ø66.0] MAX. Ø.17 HOLES THRU,
4X [Ø4.3]
2.40 MOTOR COOLING
INLET LOCATED AS SHOWN ON
12 [61.0] Ø6.50
34
5 [Ø165.10] BOLT CIRCLE
CL
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
[19.1] 33°
DISCHARGE [26.4]
49° 26° 45°
SEE DETAIL "E" & "M" 2.12 EARTH GROUND
[53.8] Ø.17
6.87 [Ø4.3] HOLE THRU,
[174.5] LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE

}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED

R EAS
2 GROUND 2 GROUND
NC
E
I

3 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE


208V-264V 208V-264V
4 4

ACCESS TO SPEED CONTROL/ 5 5


CALIBRATION

DETAIL "E" DETAIL "M"


(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 117416 117415


Stages - 3 3
in. H2O 154 154
Max Sealed Vacuum
mbar 383.6 383.6
in. H2O 169 169
Max Sealed Pressure
mbar 421 421
CFM 87 87
Max Flow Rate
m3/hr 147.9 147.9
Speed Control - Mechanical Electrical

Notes:
• Input Voltage Range: 208-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 19


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt Standard Flow - IntelliGen (TM)

Typical Performance

Flow (m3/hr)

117416, 117415
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 20


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt High Flow - IntelliGen (TM)
PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]

Ø1.75
[Ø44.5]
INCH
[MM] INLET 2.12
[53.8]
3X 90°
Ø1.75
[Ø44.5] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40 MOTOR COOLING LOCATED AS SHOWN ON
[61.0] INLET Ø6.50 BOLT CIRCLE
1
2
3
4
[Ø165.10]
CL 5

SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04
"B" 33°
DISCHARGE [26.4]
49° 26° 45°
SEE DETAIL "E" & "M" "A" EARTH GROUND
Ø.17 HOLE THRU,
[Ø4.3]
"L"
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6]BOLT CIRCLE

}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
2 GROUND 2 GROUND
NC
R EA S
3 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE
E
I

208V-264V 208V-264V
4 4
5 5
ACCESS TO SPEED CONTROL/
CALIBRATION
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS

Part/ Model Number

Specification Units 119152 119151 119154 119153 119156 119155


Flow - High Flow High Flow High Flow High Flow High Flow Ultra High Flow
Stages - 1 1 2 2 3 1
in. H2O 46 46 80 80 119 42
Max Sealed Vacuum
mbar 114.6 114.6 199.3 199.3 296.4 104.6
in. H2O 56 56 111 111 130 45
Max Sealed Pressure
mbar 139.5 139.5 276.5 276.5 323.8 112.1
CFM 180 180 140 140 113 268
Max Flow Rate
m3/hr 306 306 238 238 192.1 455.6
Inches 1.75 1.75 1.75 1.75 1.75 2.75/2.50
Inlet/Outlet Diameter
mm 44.5 44.5 44.5 44.5 44.5 69.9/63.5
Inches .47 .47 1.58 1.58 1.19 0.71
Length (I)
mm 11.9 11.9 40.1 40.1 30.2 18
Inches 5.13 5.13 6.19 6.19 7.17 5.37
Length (L)
mm 130.3 130.3 157.2 157.2 182.1 136.4
Speed Control - Mechanical Electrical Mechanical Electrical Electrical Electrical

Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 21


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt High Flow - IntelliGen (TM)

Typical Performance

Flow (m3/hr)

119151, 119152
119153, 119154
Pressure (inch H2O)

Pressure (mbar)
119163
119155

Flow (CFM)
13
Current (A)

10
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
Connections:
• All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 22


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
EMI Filter
120/240 Volt AC

14.12±.25
CONNECTOR SPECIFIC (358.6±6.4) CONNECTOR SPECIFIC
2.938±.014
INCH TO BLOWER TYPE (74.63±0.35) TO BLOWER TYPE
(MM)

2.07

LINE

LOAD
(52.6)

Ø .189 THRU
(4.8)

6.50±.12 REF. 4.0±.12 RE F.


(165.1±3.0) (101.6±3.0)

1.16 MAX. 250W / 400W


(29.5)

1.53 MAX 800W / 1200W


(38.9)

Part/ Model Number

Specification Units 5-90238-1 5-90239-1 5-90238-2 5-90239-2


Description - 250 W Windjammer 400 W Windjammer 800 W Windjammer 1200 W Windjammer

Part Number 5-90238-1 5-90239-1 5-90238-2 5-90239-2


Description Mates with Mates with Mates with Mates with
250 W Series Windjammer 400 W Series Windjammer 800 W Series Windjammer 1200 W Series Windjammer
Length (“L” above) inches 2.938 2.938 2.938 2.938
Length (“L” above) mm 74.63 74.63 74.63 74.63

Line Side: Connector Termination Immunity Testing


Description Wire Color IEC 801-2 ESD
IEC 1000-4-2 Electrostatic discharge
Ground GREEN / YELLOW
EN 61000-4-2 Static from humans
AC Hot BROWN
IEC 801-3 Radiated RF
AC Hot BLUE IEC 1000-4-3 RF electromagnetic field
EN 61000-4-3 Walkie talkies, transmitters, etc.
IEC 801-4 EFT
Load Side: Connector Termination IEC 1000-4-4 Electrical fast transient
Description Wire Color EN 61000-4-4 Relays and motors on and off
Speed (LO) BLUE IEC 801-5 Lightning on power line
Speed (HI) RED IEC 1000-4-5 Surge voltage
EN 61000-4-5 Lightning
Ground GREEN / YELLOW
IEC 801-6 Conducted CW
AC Hot BROWN IEC 1000-4-6 Conducted induced RF energy
AC Hot BLUE EN 61000-4-6 Power and signal lines near transmitters
IEC 1000-4-8 Radiated magnetic
EN 61000-4-8 Power frequency magnetic field; Magnetic flux from
Emissions Testing power lines
CISPR 11, I ISM (Group I) No intentional emissions IEC 1000-4-11 Voltage dips
EN 55011, I Industrial, Scientific, and Medical EN 61000-4-11 Drop in voltage for a short period
CISPR 11, II ISM (Group II) intentional ISM emissions IEC 1000-4-11 Voltage interrupts
EN 55011, II Industrial, Scientific, and Medical EN 61000-4-11 Loss of power for a short period
CISPR 14 HHA IEC 1000-4-11 Voltage variations
EN 55014 Household appliances and similar apparatus EN 61000-4-11 Power line voltage variations

CISPR 14 Clicks (Discontinuous Noise)


EN 55014 Impulsive noise due to transients; Required for all impulsive • Primarily used with the Windjammer product line
CISPR 22 ITE
EN 55022 Information Technology Equipment; Emissions testing for
• Excellent for meeting European application requirements
• Hard-mount option available

NOTES:
Contact your AMETEK Sales Engineer for updates and more information on
this product.
This document is for informational purposes only and should not be consid-
ered as a binding description of the products and their performance in all
applications. Specific dimensions may change based on wattage.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 23


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Variable Flow Filters
For use with AMETEK Windjammer and Nautilair Blowers

Filter Design Features


AMETEK Technical & Industrial Product’s inlet filter is designed
to protect the blower and the air distribution system from dust
and other air borne particles and contaminants. The compact
design, with slip fit connection; fits within the blower’s diameter.
Minimal pressure drop through filter. This is an ideal filter
for electronic cooling, material handling, and other pressure
systems. The AMETEK Windjammer blower has two models,
one for each inlet diameter; the AMETEK Nautilair blower has
one model, designed to fit on all five of the blowers.

Part/ Model Number

Specification Units 551733 551692 551782


in. H2O 4.8 3.6 0.25
Pressure Drop
mbar 12 9 0.6
Inches 1.25 1.75 6
Inlet Diameter D1
mm 31.8 44.5 152.4
CFM 100 180 500
Flow Rate
m3/hr 170 306 850
Efficiency - 99+% @ 10 Microns 99+% @ 10 microns 97+% @ 2 microns, 99+% @ 5 microns
Description - Slip Fit with Pleated Polyester Media Slip Fit with Pleated Polyester Media Slip Fit with Pleated Polyester Media
Inches 4.75 4.375 9.75
Diameter
mm 120.7 111.1 247.7
Inches 5.75 5.75 10
Height
mm 146.1 146.1 254
Series - Windjammer Windjammer Nautilair

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 24


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
12/24 VDC Input, Standard Output
INCH FLANGE "B" FLANGE "A"
[MM] 4X HOLES Ø.23/[5.8] THRU. 39° 39°
.72 EQ. SPACED AS SHOWN .37 THRU.
4X HOLES Ø [9.3]
2X[18.3] POWER/CONTROL CONNECTION DETAIL
3.27
Ø[83.1] ON A Ø2.80/[71.0]
BOLT CIRCLE THRU. SPACED AS SHOWN
3.40 BOLT CIRCLE.
ON A Ø [86.4]
.11
2X[2.67]
20.0
[508.0]
1.14 1.14 (TO MOTOR O.D.)
[29.0] 2.97 [29.0]
.07 [75.44]
[1.9]
(FLANGEL C OFFSET) 4.17
Ø[105.79] RED LEAD BLUE LEAD
.35
[8.9] MAX. (+Vin) TACHOUT
45° 2.20 BLACK LEAD ORANGE LEAD
[55.9] GND (-Vin) SPEED CONTROL
1.43 (0-10 VDC NOMINAL)
90° METRIC THREAD SIZES, M3-M6 UPON REQUEST;
[36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
2.20 3.07
[78.0] 3.31 3.94
[55.9] Ø[84.0] OR Ø[100.0] BOLT CIRCLE OR BOTH.
8.04
[204.22]MAX. Ø2.60 MAX.
PRESSURE TAP [Ø66.04] .21 BLOWER METRIC THREAD SIZES, M3-M6 UPON REQUEST;
MOTOR COOLING [5.33] DISCHARGE .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION MOTOR COOLING DISCHARGE 3.31 3.94
INLET 4.7 2 Ø[84.0] OR Ø[100.0] BOLT CIRCLE OR BOTH.
2.8 2 [119.42]
[71.1 2]
45°

3.46
[87.88]

7.46
[189.5]
MAX.
Ø5.68
[Ø144.3]

Ø4.35
[Ø110.5] Ø4.95
[Ø125.7]
Ø1.975 Ø1.975
[Ø50.17] [Ø50.17]
BLOWER INLET BLOWER INLET
ACCESS TO
SPEED SPEED CONTROL/ 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL/ CL CALIBRATION [42.2] KD/H VENTURI HONEYWELL VENTURI
CALIBRATION 5.38
20° [136,7]MAX.

Part/ Model Number

Specification Units 150186 150180 150181 150184 150185


Voltage VDC 12 24 24 24 24
Flange Type - Large "A" Large "A" Large "A" Small "B" Small "B"
Speed Control - Mechanical Mechanical Electronic Mechanical Electronic

Notes:
• Input Voltage Range: 12 or 24 Volts DC
• Operating Temperature (Ambient Air and Working Air): -25°C to 50°C
• Storage Tempurature: -40°C to 85°C
• Dielectric Testing: 500 Volts AC RMS 50/60 Hz applied for one second between input pins and ground, 1mA leakage maximum.
• Speed Control Methods: 0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed.
Access for speed adjustment located in motor housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constucted of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower
is installed into the final application.
• Micellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER/CONTROL CONNECTION: Stripped wire leads.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 25


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
12/24 VDC Input, Standard Output

Typical Performance

Flow (m3/hr)
0 117 134 151 168 185 202 219
18 45

15 12V 37.5

24V
Pressure (inch H2O)

12 30

Pressure (mbar)
9 22.5

6 15

3 7.5

0 0
0 25 50 75 100 125 150 175

Flow (CFM)

24
Current (A)

17

10

3
0 25 50 75 100 125 150 175

9000
Speed (RPM)

8000

7000

6000
0 25 50 75 100 125 150 175

350
Power Demand

250
(Watts)

150

50
0 25 50 75 100 125 150 175

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 26


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output
INCH
[MM] FLANGE "B" FLANGE "A"
.72 4X HOLES Ø.23/[5.8] THRU. 39° 39° .37 THRU.
2X [18.3] EQ. SPACED AS SHOWN 4X HOLES Ø [9.3]
3.27
Ø[83.1] ON A Ø2.80/[71.0] THRU. SPACED AS SHOWN
BOLT CIRCLE 3.40 BOLT CIRCLE. POWER/CONTROL CONNECTION DETAIL
ON A Ø[86.4]
.11
2X[2.67] NOT USED PWM INPUT/0-10VDC
SPEED COMMAND
1 2 3
1.14 1.14 1 2 3 4 5
[29.0] 2.97 [29.0] NOT USED
.07 [75.44] V+ ISOLATED CONTROL NEUTRAL AC INPUT
[1.9] GROUND LINE VOLTAGE
108V-132V
(FLANGE C OFFSET) 4.17 TACH-OUT
Ø [105.79] CONTROL POWER
.35 CONNECTION
[8.9] MAX. CONNECTION
45° 2.20
[55.9]
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
2.20 3.07 3.31 3.94
[55.9] [78.0] Ø[84.0] OR Ø[100.0] BOLT CIRCLE OR BOTH.
8.04
[204.22] MAX.
PRESSURE TAP .21 BLOWER METRIC THREAD SIZES, M3-M6 UPON REQUEST;
OPTION [5.33] DISCHARGE .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
MOTOR COOLING 3.31 3.94
Ø[84.0] OR Ø[100.0] BOLT CIRCLE OR BOTH.
DISCHARGE
45°

3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°
30° CL 38° AS E
E
IN C R

CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION CONTROL/ [Ø50.17] [Ø50.17]
CALIBRATION BLOWER INLET BLOWER INLET
MOTOR COOLING
1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
INLET KD/H VENTURI HONEYWELL VENTURI
ACCESS TO SPEED [42.2]
5.45
EARTH GROUND CONTROL/CALIBRATION [138.4] MAX.

Part/ Model Number

Specification Units 150500 150501 150502 150503 150504 150505


Flange Type - Large "A" Large "A" Large "A" Small "B" Small "B" Small "B"
Speed Control - PWM 0-10 VDC Mechanical PWM 0-10VDC Mechanical

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz, single phase.
• input Current: 3 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under FIle E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower constuction to dampen
vibration within the motor. Two piece blower housing assembly sealed with O-ring gaket for combustion applications. Customer is responsible to check for any leakage
once th blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstucted. Motor ventilation air to be free of oils and other foreign
particles (i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
CONTROL CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnessess available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 27


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 28


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output
FLANGE "B" FLANGE "A"
INCH
4X HOLES Ø.23/[5.8] THRU. 39° 39°
.72 4X HOLES Ø .37 THRU.
[MM]
2X [18.3] EQ. SPACED AS SHOWN [9.3]
3.27 ON A Ø2.80/[71.0]
Ø[83.1] THRU. SPACED AS SHOWN
BOLT CIRCLE POWER/CONTROL CONNECTION DETAIL
ON A Ø 3.40 BOLT CIRCLE.
[86.4]
2X .11 NOT USED PWM INPUT/0-10VDC
[2.67] SPEED CONTROL
1 2 3
1.14 1.14 1 2 3 4 5
[29.0] 2.97 [29.0] NOT USED
.07 [75.44] V+ ISOLATED CONTROL NEUTRAL AC INPUT
[1.9] GROUND LINE VOLTAGE
(FLANGE CLOFFSET) 4.17 TACH-OUT CONTROL POWER
Ø[105.79] CONNECTION CONNECTION
.35
[8.9] MAX.
45° 2.20
[55.9]
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
2.20 3.07
[78.0] 3.31 3.94
[55.9] Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
8.04
[204.22] MAX.
.21 BLOWER METRIC THREAD SIZES, M3-M6 UPON REQUEST;
PRESSURE TAP .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION [5.33] DISCHARGE
MOTOR COOLING 3.31 3.94
Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
DISCHARGE
45°

3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°

30° 38° AS E
CL
E
INCR

CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION CONTROL/ [Ø50.17] [Ø50.17]
CALIBRATION BLOWER INLET BLOWER INLET
MOTOR COOLING
INLET 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
[42.2] KD/H VENTURI HONEYWELL VENTURI
ACCESS TO SPEED 5.45
EARTH GROUND CONTROL/CALIBRATION
MECHANICAL SPEED [138.4] MAX.
COMMAND

Part/ Model Number

Specification Units 150520-00 150521-00 150522-00 150523-00 150524-00 150525-00


Flange Type - Large "A" Large "A" Large "A" Small "B" Small "B" Small "B"
Speed Control - PWM 0-10 VDC Mechanical PWM 0-10 VDC Mechanical

Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 2 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under FIle E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials.
Blower housing assembly constructed of die cast aluminum. Impeller constucted from hardened aluminum. Rubber isolation mounts built into blower constuction to dampen
vibration within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the
blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
CONTROL CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 29


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb./ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 30


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, High Output
INCH
[MM] FLANGE "B" FLANGE "A" POWER CONNECTION DETAIL USED
W/PWM OR MECHANICAL SPEED CONTROL
.72 4X HOLES Ø .23/[5.8] THRU. 39° 39° .37 THRU.
2X[18.3] EQ. SPACED AS SHOWN 4X HOLES Ø[9.3]
3.27
Ø[83.1] ON A Ø 2.80/[71.0] THRU. SPACED AS SHOWN SPEED CONNECTION DETAIL 3 2 1
BOLT CIRCLE 3.40 BOLT CIRCLE. USING PWM CONTROL OPTION
ON A Ø [86.4] NOT USED
.11
2X[2.67] NEUTRAL
5 4 3 2 1 LINE
1.14 1.14 COMMON
[29.0] 2.97 [29.0]
.07 [75.44] PWM POWER CONNECTION DETAIL USED
[1.9] NOT USED W/0-10VDC SPEED CONTROL
(FLANGEL C OFFSET) 4.17 TACH-OUT
Ø[105.79]
.35 DC VOLTAGE
[8.9] MAX. 1 2 3 4 5
45° 2.20 ISOLATED SPEED LOW (-)
[55.9] CONTROL INPUT HIGH (+)
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST; 0-10VDC
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A NOT USED
2.20 3.07 3.31 3.94 NEUTRAL
[55.9] [78.0] Ø[84.0]OR Ø[100.0] BOLT CIRCLE OR BOTH. LINE
8.04
[204.22]MAX. Ø2.60
[Ø66.04] MOTOR COOLING .21 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
PRESSURE TAP MOTOR COOLING DISCHARGE BLOWER .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION [5.33] DISCHARGE
INLET 4.72 3.31 3.94
2.8 2 [119.4 ]2 Ø[84.0] OR Ø[100.0] BOLT CIRCLE OR BOTH.
[71.1 ]2
45°

3.46
[87.88]

7.46
[189.5] Ø5.68
MAX. [Ø144.3]

Ø4.35 Ø4.95
[Ø110.5] [Ø125.7]
Ø1.975 Ø1.975
PWM CONTROL 1.38 [Ø50.17] [Ø50.17]
AVAILABLE [35.1] BLOWER INLET BLOWER INLET
SENSITIVITYCL 4° 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL [42.16] KD/H VENTURI HONEYWELL VENTURI
5.38
28° [136.7] MAX.
EARTH GROUND

Part/ Model Number

Specification Units 150940 150941 150942 150944 150945


Flange Type - Small "B" Small "B" Small "B" Large "A" Large "A"
Speed Control - PWM 0-10 VDC Mechanical PWM 0-10 VDC

Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 3 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
4-20mA speed control available upon request.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Option Card available for Customization
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is
installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350789-1.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 640900-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-30-3055.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 31
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, High Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 32


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output Enhanced

INCH FLANGE "B" FLANGE "A"


[MM] 4X HOLES Ø.23/[5.8] THRU. 39° 39°
.72
2X [18.3] EQ. SPACED AS SHOWN 4X HOLES Ø .37 THRU.
3.27 [9.3]
Ø [83.1] ON A Ø2.80/[71.0]
THRU. SPACED AS SHOWN
BOLT CIRCLE POWER/CONTROL CONNECTION DETAIL
ON A Ø 3.40 BOLT CIRCLE.
[86.4]
2X .11 NOT USED PWM INPUT/0-10VDC
[2.67] SPEED CONTROL
1 2 3
1.14 1.14 1 2 3 4 5
[29.0] 2.97 [29.0] NOT USED
.07 [75.44] CONTROL NEUTRAL AC INPUT
V+ ISOLATED VOLTAGE
[1.9] GROUND LINE
(FLANGE CL OFFSET) 4.17 TACH-OUT CONTROL POWER
Ø [105.79] CONNECTION CONNECTION
.35
[8.9] MAX.
45° 2.20
[55.9]
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
2.20 3.07
[78.0] 3.31 3.94
[55.9] Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
8.04
[204.22] MAX.
.21 BLOWER METRIC THREAD SIZES, M3-M6 UPON REQUEST;
PRESSURE TAP .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION [5.33] DISCHARGE
MOTOR COOLING 3.31 3.94
Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
DISCHARGE
45°

3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°

30° 38°
CL AS E
E
IN CR

CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION [Ø50.17] [Ø50.17]
CONTROL/
BLOWER INLET BLOWER INLET
CALIBRATION
MOTOR COOLING
INLET 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
ACCESS TO SPEED [42.2] KD/H VENTURI HONEYWELL VENTURI
EARTH GROUND CONTROL/CALIBRATION 5.45
MECHANICAL SPEED [138.4] MAX.
COMMAND

Part/ Model Number

Specification Units 150560 150561 150562 150563 150564 150565


Flange Type - Large "A" Large "A" Large "A" Small "B" Small "B" Small "B"
Speed Control - PWM 0-10 VDC Mechanical PWM 0-10 VDC Mechanical

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 6 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is
installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
SPEED CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 33


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output Enhanced

Typical Performance

Flow (m3/hr)

0 42 85 127 170 212 255 297 340


28 70

24 60

20 50
Pressure (inch H2O)

Pressure (mbar)
16 40

12 30

8 20

4 10

0 0
0 25 50 75 100 125 150 175 200

Flow (CFM)

6
Current (A)

3
0 25 50 75 100 125 150 175 200

10500

9750
Speed (RPM)

9000

8250

7500
0 25 50 75 100 125 150 175 200
Power Demand
(Watts)

0 25 50 75 100 125 150 175 200

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 34


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output Enhanced
INCH FLANGE "B" FLANGE "A"
[MM] 4X HOLES Ø.23/[5.8] THRU.
.72 39° 39° .37 THRU.
2X [18.3] EQ. SPACED AS SHOWN 4X HOLES Ø
[9.3]
3.27 ON A Ø2.80/[71.0]
Ø THRU. SPACED AS SHOWN
[83.1] BOLT CIRCLE POWER/CONTROL CONNECTION DETAIL
3.40
ON A Ø BOLT CIRCLE.
[86.4]
2X .11 NOT USED PWM INPUT/0-10VDC
[2.67]
SPEED CONTROL 1 2 3
1.14 1.14 1 2 3 4 5
2.97 NOT USED
[29.0] [29.0]
.07 [75.44] CONTROL NEUTRAL AC INPUT
V+ ISOLATED VOLTAGE
[1.9] GROUND LINE
(FLANGE CL OFFSET) 4.17 TACH-OUT CONTROL POWER
Ø [105.79] CONNECTION CONNECTION
.35
MAX.
[8.9]
45° 2.20
[55.9]
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
2.20 3.07
[78.0] 3.31 3.94
[55.9] Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
8.04
MAX.
[204.22]
.21 BLOWER METRIC THREAD SIZES, M3-M6 UPON REQUEST;
PRESSURE TAP .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION [5.33] DISCHARGE
MOTOR COOLING 3.31 3.94
Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
DISCHARGE
45°

3.46
[87.88]
Ø6.17
[Ø156.72]
7.46 MAX.
[189.5]
MAX. Ø5.68
[Ø144.3]
20°

30° 38°
CL E
IN CR AS E

CONTROL Ø4.35
CONNECTION [Ø110.5] Ø4.95
CL CL [Ø125.7]
POWER SPEED Ø1.975 Ø1.975
CONNECTION CONTROL/ [Ø50.17] [Ø50.17]
CALIBRATION BLOWER INLET BLOWER INLET
MOTOR COOLING
ACCESS TO SPEED INLET 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL/CALIBRATION [42.2] KD/H VENTURI HONEYWELL VENTURI
MECHANICAL SPEED 5.45
EARTH GROUND MAX.
[138.4]
COMMAND

Part/ Model Number

Specification Units 150580 150581 150582 150583 150584 150585


Flange Type - Large "A" Large "A" Large "A" Small "B" Small "B" Small "B"
Speed Control - PWM 0-10 VDC Mechanical PWM 0-10 VDC Mechanical

Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 3 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1 kHz to 10 kHz)
0 to 10 VDC speed control.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials.
Blower housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen
vibration within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the
blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP Universal MATE-N-LOK, part no. 1-350943-0.
SPEED CONNECTION: Blower connector, Molex Mini-Fit Jr., part no. 39-30-3056.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 35
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output Enhanced

Typical Performance

Flow (m3/hr)

0 42 85 127 170 212 255 297 340


28 70

24 60

20 50
Pressure (inch H2O)

Pressure (mbar)
16 40

12 30

8 20

4 10

0 0
0 25 50 75 100 125 150 175 200

Flow (CFM)

4
Current (A)

1
0 25 50 75 100 125 150 175 200

10500

9750
Speed (RPM)

9000

8250

7500
0 25 50 75 100 125 150 175 200
Power Demand
(Watts)

0 25 50 75 100 125 150 175 200

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 36


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
120 Volt AC Input, Single Phase, High Output

INCH
[MM] FLANGE "B" FLANGE "A" POWER CONNECTION DETAIL USED
W/PWM OR MECHANICAL SPEED CONTROL
4X HOLES Ø.23/[5.8] THRU. 39° 39°
.72
2X [18.3] EQ. SPACED AS SHOWN 4X HOLES Ø .37 THRU.
[9.3] 1
3.27
Ø [83.1] ON A Ø2.80/[71.0]
THRU. SPACED AS SHOWN SPEED CONNECTION DETAIL 3 2
BOLT CIRCLE USING PWM CONTROL OPTION
ON A Ø 3.40 BOLT CIRCLE. NOT USED
[86.4]
2X .11 NEUTRAL
[2.67] 5 4 3 2 1 LINE
1.14 1.14 COMMON
[29.0] 2.97 [29.0]
.07 [75.44] PWM POWER CONNECTION DETAIL USED
[1.9] NOT USED W/0-10VDC SPEED CONTROL
(FLANGE CL OFFSET) 4.17 TACH-OUT
Ø [105.79]
.35 DC VOLTAGE 1 2 3 4 5
[8.9] MAX.
45° 2.20 ISOLATED SPEED LOW (-)
[55.9] CONTROL INPUT HIGH (+)
1.43 METRIC THREAD SIZES, M3-M6 UPON REQUEST; 0-10VDC
90° [36.32] .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A NOT USED
2.20 3.07 3.31 3.94 NEUTRAL
[55.9] [78.0] Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
8.04 LINE
[204.22] MAX.
Ø2.60
[Ø66.04] MOTOR COOLING .21 METRIC THREAD SIZES, M3-M6 UPON REQUEST;
PRESSURE TAP
MOTOR COOLING DISCHARGE
BLOWER .43/[10.9] DEEP EQ. SPACED AS SHOWN ON A
OPTION [5.33] DISCHARGE
INLET 4.72 3.31 3.94
2 Ø [84.0] OR Ø [100.0] BOLT CIRCLE OR BOTH.
2.82 [119.4 ]
[71.1 2 ]
45°

3.46
[87.88]

7.46
[189.5] Ø5.68
MAX. [Ø144.3]

Ø4.35
[Ø110.5] Ø4.95
[Ø125.7]
Ø1.975 Ø1.975
PWM CONTROL 1.38 [Ø50.17] [Ø50.17]
AVAILABLE BLOWER INLET BLOWER INLET
[35.1]
SENSITIVITY CL 4° 1.66 INLET COMPATIBLE WITH INLET COMPATIBLE WITH
CONTROL [42.16] KD/H VENTURI HONEYWELL VENTURI
5.38
28° [136.7] MAX.
EARTH GROUND

Part/ Model Number

Specification Units 150930 150931 150932 150934 150935


Flange Type - Small "B" Small "B" Small "B" Large "A" Large "A"
Speed Control - PWM 0-10 VDC Mechanical PWM 0-10 VDC

Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 6.5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation) (1kHz to 10 kHz)
0 to 10 VDC speed control.
4-20mA speed control available.
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor housing.
• Approximate Weight: 4.8 Lbs. / 2.2 Kg.
• Option Card available for Customization
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower housing
assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration within the motor.
Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350789-1.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 640900-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-30-3055.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 37


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 7.6" (193mm) Variable Speed Blower
120 Volt AC Input, Single Phase, High Output

Typical Performance

(at constant 48V input)


Flow (m3/hr)

50 125

40 100
Pressure (inch H2O)

Pressure (mbar)
30 75

20 50

10 25

0 0

Flow (CFM)

8
Current (A)

15000

13000
Speed (RPM)

11000

9000

7000

600
Power Demand

550
(Watts)

500
450
400
350

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department..
AMETEK DYNAMIC FLUID SOLUTIONS B 38
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.0" (203mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

POWER CONNECTION

INCH
[MM]
{
AC INPUT NEUTRAL
VOLTAGE LINE SEE POWER/CONTROL
DETAILS
4.50 PINS NOT USED
[114.2]
Ø7.70 MAX. 1.60 BLOWER 17° 53°
Ø8.16 [Ø195.0] [40.51] DISCHARGE
[Ø207.3] Ø2.18
[Ø55.25]I.D.
Ø2.38
[Ø60.33]O.D.
65° C SPEED
L
E CONTROL/
US CALIBRATION
RE

37° 3.00
Ø2.00 [76.2]
[Ø50.8]
OR

BLOWER
INLET
Ø5.68
A IR

[Ø144.3]
RE P

DRAIN HOLE
37° OPTION

ON
T
NO

45°

TI
DO TA
R
DANGE 65° RO

Ø1.3 MAX.
[Ø33.0]
1.13 MOTOR COOLING MOTOR COOLING
5X MOUNTING SLOTS THRU 5X [28.8] DISCHARGE INLET DRAIN HOLE
SPACED AS SHOWN Ø8.7 MAX. 2.85 OPTION
[Ø220.2] [72.3] MAX.
5.75
[146.1] MAX.

Part/ Model Number

Specification Units 117814-00


Speed Control - Mechanical

Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 2 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Method: Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for the
speed adjustment located in the motor housing.
• Approximate Weight: 4.2 Lbs. / 1.9 Kg
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and compliant under the CE Low Voltage Directive 2006/95/EC.
• Design Features: Designed to provide variable airflow in non-premix/non-combustion gas applications. Blower housing/cover and impeller assembly constructed of
polypropylene to protect against corrosion.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign
particles, (i.e. breathing quallity air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION: Blower connector, AMP MTA 156 series, part no. 643569-2.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 39


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.0" (203mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lbs./ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 40


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED ADJUSTMENT SPEED ADJUSTMENT

INCH 1 2 3 4 5

(MM) BLACK (LINE)


WHITE (NEUTRAL)
WHITE (NEUTRAL) BLU (COMMON) BLACK (LINE) }AC INPUT VOLTAGE

PWM IN (BLK)
NOT USED
5.50
(139.7) BLUE (COMMON) }
RED (10V DC SIGNAL) SPEED COMMAND

9.80±.05 4.724±.010
TACH-OUT (WHT)
(245±1.27) (120±0.25)
5.25 ±.03 DC VOLTAGE (RED) 2.362 .350
(133.4±0.76) . .38 (60.0) 4X Ø THRU
4X R (8.9)
(9.7)

6X M8X1.25 THD’D. HOLES


EXHAUST .50/(12.7) DP., EQ. SPACED
MOTOR
2.362 AS SHOWN ON A 5.512/(140)
COOLING
(60.0) BOLT CIRCLE.
EXHAUST 5.50
(139.7)

2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)
5.68
CONTROL Ø
(144.3)
CONNECTION CL
SPEED
POT.CL CL
POWER
(28°) CONNECTION 4.331
Ø
(110)
(43°)
28°±1° 8.70±.05 .138
3.95±.03
(221±1.3) Ø (3.5)
(100.3±0.76)
{INTAKE} 6X 0.56±.03 4.331
MOTOR Ø
.118 (110)
14.00±1.00 COOLING (14.2±0.76)
(3.0)
43°±3° (355.6±25.4) INLET
AIR INTAKE DETAIL
7.60 MAX.
6.50±2.60 (193)
2X INCL. BOW-OUT
(165.1±25.4) GROUND ( )

Part/ Model Number

Specification Units 150330 150331 150332


Speed Control - Mechanical 0-10 VDC PWM

Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 8.5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15-45 VDC @ 500 Hz-10 kHz, and tachometer output (2 Pulses / Revolution).
Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. THe potentiometer can be preset for a specific speed. Access for speed adjustment located in motor
housing.
4-20 mA speed control also available.
• Approximate Weight: 7.8 Lbs. / 3.5 Kg
• Option Card available for Customization
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower constuction to dampen vibration
within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Custome is responsible to check for any leakage once the blower
is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harness available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 41
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 42


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
120 Volt AC Input, Single Phase, High Output

POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED ADJUSTMENT SPEED ADJUSTMENT

INCH 1 2 3 4 5

(MM) BLACK (LINE)


BLACK (LINE) BLU (COMMON)
PWM IN (BLK) 5.50 WHITE (NEUTRAL) }
AC INPUT VOLTAGE

WHITE (NEUTRAL) NOT USED (139.7)


4.724±.010
RED (10V DC SIGNAL)
BLUE (COMMON) }
SPEED COMMAND
9.80±.05 TACHOUT (WHT)
(120±0.25)
(245±1.27)
DC VOLTAGE (RED) 2.362 .350
5.25 ±.03 . .38 (60.0) 4X Ø THRU
4X R (8.9)
(133.4±0.76) (9.7)

6X M8X1.25 THD’D. HOLES


EXHAUST .50/(12.7) DP., EQ. SPACED
MOTOR
2.362 AS SHOWN ON A 5.512/(140)
COOLING
(60.0) BOLT CIRCLE.
EXHAUST 5.50
(139.7)

2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)

CONTROL
CONNECTION CL 5.68
Ø
SPEED (144.3)
POT.CL CL
POWER
(28°) CONNECTION 4.331
Ø
(110)
(43°)
8.70±.05 .138
28°±1° 3.95±.03
(221±1.3) Ø (3.5)
MOTOR (100.3±0.76)
COOLING {INTAKE} 6X 0.56±.03 4.331
Ø
INLET .118 (14.2±0.76) (110)
14.00±1.00
8.10 MAX. (3.0)
43°±3° (355.6±25.4)
(205.7)
INCL. BOW-OUT AIR INTAKE DETAIL
6.50±2.60
2X
(165.1±25.4) GROUND ( )

Part/ Model Number

Specification Units 150230 150231 150232


Speed Control - Mechanical 0-10 VDC PWM

Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 12 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15 - 45 VDC @ 500 Hz - 10 kHz, and tachometer output (2 Pulses /
Revolution). Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located
in motor housing.
4-20mA speed control available.
• Approximate Weight: 9.3 Lbs. / 4.2 Kg
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and CSA C22.2#133 under File LR43448
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower
housing assembly constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to
dampen vibration within the motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check
for any leakage once the blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other
foreign particles, (i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 43
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
120 Volt AC Input, Single Phase, High Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 44


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output

POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED CONSTANT SPEED ADJUSTMENT

INCH 1 2 3 4 5

(MM) BLACK (LINE)


BLACK (LINE)
}
BLU (COMMON)
5.50 WHITE (NEUTRAL) AC INPUT VOLTAGE
PWM IN (BLK) RED (10V DC SIGNAL)
WHITE (NEUTRAL)
NOT USED
(139.7)
4.724±.010
BLUE (COMMON) }SPEED COMMAND
9.80±.05 TACHOUT (WHT)
(120±0.25)
(245±1.27) DC VOLTAGE (RED) 2.362 .350
5.25 ±.03 . .38 (60.0) 4X Ø THRU
4X R (8.9)
(133.4±0.76) (9.7)

6X M8X1.25 THD’D. HOLES


EXHAUST .50/(12.7) DP., EQ. SPACED
MOTOR
2.362 AS SHOWN ON A 5.512/(140)
COOLING
(60.0) BOLT CIRCLE.
EXHAUST 5.50
(139.7)

2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)

CONTROL 5.68
CONNECTION CL Ø
(144.3)
SPEED C
POT. L C
L
(28°) POWER Ø
4.331
CONNECTION (110)
(43°)
8.70±.05 .138
28°±1° 3.95±.03
(221±1.3) Ø (3.5)
MOTOR (100.3±0.76)
COOLING {INTAKE} 6X 0.56±.03 4.331
Ø
14.00±1.00 INLET .118 (14.2±0.76) (110)
7.60 MAX. (3.0)
43°±3° (355.6±25.4)
(193)
AIR INTAKE DETAIL
INCL. BOW-OUT
6.50±2.60
2X
(165.1±25.4) GROUND ( )

Part/ Model Number

Specification Units 150340 150341 150342


Speed Control - Mechanical Electronic 2 Electronic 1

Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15 - 45 VDC @ 500 Hz - 10 kHz, and tachometer outpuT.
(2 Pulses / Revolution). Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor housing.
4-20mA speed control available.
• Approximate Weight: 7.8 Lbs. / 3.5 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and CSA C22.2#133 under File LR43448.
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower housing assembly
constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration within the motor. Two piece
blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is installed into the final application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 45


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 46


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
240 Volt AC Input, Single Phase, High Output

POWER CONNECTION USING MECHANICAL OR PWM PWM CONTROL CONNECTION (OPTION) POWER CONNECTION USING 0-10 VDC
SPEED ADJUSTMENT SPEED ADJUSTMENT

INCH 1 2 3 4 5

(MM) BLACK (LINE)


BLACK (LINE) BLU (COMMON)
5.50
}
WHITE (NEUTRAL) AC INPUT VOLTAGE
WHITE (NEUTRAL) PWM IN (BLK)
NOT USED
(139.7)
RED (10V DC SIGNAL)
BLUE (COMMON) }
SPEED COMMAND
4.724±.010
9.80±.05 TACHOUT (WHT) (120±0.25)
(245±1.27) 2.362
DC VOLTAGE (RED) .350
5.25 ±.03 . .38 4X Ø THRU
4X R (60.0) (8.9)
(133.4±0.76) (9.7)

6X M8X1.25 THD’D. HOLES


EXHAUST .50/(12.7) DP., EQ. SPACED
MOTOR
2.362 AS SHOWN ON A 5.512/(140)
COOLING
(60.0) BOLT CIRCLE.
EXHAUST 5.50
(139.7)

2.64±.03 4.724±.010
(67.1±0.76) (120±0.25)

CONTROL 5.68
CONNECTION CL Ø
SPEEDC (144.3)
POT. L
CL
(28°) POWER 4.331
CONNECTION Ø
(110)
(43°)
8.70±.05 .138
28°±1° 3.95±.03
(221±1.3) Ø (3.5)
MOTOR (100.3±0.76)
COOLING {INTAKE} 6X 0.56±.03 4.331
INLET Ø
.118 (14.2±0.76) (110)
14.00±1.00
8.10 MAX. (3.0)
43°±3° (355.6±25.4)
(205.7)
INCL. BOW-OUT AIR INTAKE DETAIL
6.50±2.60
2X
(165.1±25.4) GROUND ( )

Part/ Model Number

Specification Units 150240 150241 150242


Speed Control - Mechanical 0-10 VDC PWM

Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase.
• Input Current: 10 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control Methods: PWM (Pulse Width Modulation). Speed control input signal of 15 - 45 VDC @ 500 Hz - 10 kHz, and tachometer output (2 Pulses / Revolution).
Optional tachometer output (3 Pulses / Revolution).
0 to 10 VDC with a speed control input current of 5 mA to 20 mA at 10 VDC Input with multi-turn potentiometer set to minimum resistance ( fully clockwise ).
Mechanical: A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in motor housing.
4-20mA speed control available.
• Approximate Weight: 9.3 Lbs. / 4.2 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories Inc. UL507 Recognized under File E94403 and CSA C22.2#133 under File LR43448
• Design Features: Designed to provide variable airflow for low NOx & CO emission in high efficiency gas fired combustion systems. Built with non-sparking materials. Blower housing assembly
constructed of die cast aluminum. Impeller constructed from hardened aluminum. Rubber isolation mounts built into blower construction to dampen vibration within the
motor. Two piece blower housing assembly sealed with O-ring gasket for combustion applications. Customer is responsible to check for any leakage once the blower is installed into the final
application.
• Miscellaneous: Blower inlet, discharge, and all motor cooling inlet and discharge vents must not be obstructed. Motor ventilation air to be free of oils and other foreign particles,
(i.e. breathing quality air). Blower is to be mounted so ventilation air cannot be re-circulated.
POWER CONNECTION (3 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 1-480701-0.
POWER CONNECTION (5 CAVITY): Blower connector, AMP Universal MATE-N-LOK, part no. 350810-1.
SPEED CONNECTION (5 CAVITY): Blower connector, Molex Mini-Fit Jr., part no. 39-01-4057.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.
AMETEK DYNAMIC FLUID SOLUTIONS B 47
100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 8.9" (226mm) Variable Speed Blower
240 Volt AC Input, Single Phase, High Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 48


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 12.3" (312mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

219.96
8.66
12.83 [332.83]
[MM]
8.89 91.95 219.46
INCH 3.62
4X Ø.35 EXHAUST Ø 8.64 BC

110.0
4.33 180.09
2X 7.09

78.65 169.93
3.10 6.69
12.39 [314.73]

COOLING AIR
DISCHARGE
Ø4.95 [Ø125.82]
INLET
Ø7.15 [181.61] ID X .13 [3.30]
.11 [2.79] INLET GROOVE
[6.35]
90.17 66.29 6X M8X1.25 .25
3.55 2.61

222.25
8.75

(1) 15-42V (OPTIONAL)


(1) 15V(SUPPLIED BY BLOWER)
(3) NOT USED
(2) TACH OUT (2) TACH OUT 3
(2) AC INPUT
VOLTAGE 240±10% 2
(3) 0-10 V SIGNAL (3) NOT USED

(4) NOT USED (4) PWM SIGNAL (1) AC INPUT


15-45V 500-10Khz (COMMON)
(5) SIGNAL GROUND
(5) SIGNAL GROUND

POWER CONNECTION

PWM CONNECTION
0-10 VDC CONNECTION

Part/ Model Number

Specification Units 150530 150531 150532


Speed Control - Mechanical 0-10VDC PWM

Notes:
• Input Voltage Range: 108 - 132 Volts AC RMS, 50/60 Hz, single phase or 153 - 187 VDC
• Input Current: 16 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: PWM 15-45 VDC @ 500 Hz - 10 kHz; 0-10 VDC; mechanical (potentiometer); 4 - 20 mA; remote potentiometer
• Approximate Weight: 28 Lbs. / 12.7 Kg
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under
File LR 43448.
• Miscellaneous: Designed to provide variable airflow for low NOx & CO emissions in high efficiency gas-fired combustion systems. Intake and exhaust tubes, all cooling
ducts and vents must not be obstructed. Intake and exaust must be free of grease, oil and foreign particles. Amp housing 350766-1 w/ Amp contacts 350536-1 for power
connection (supplied by customer) and Molex housing 39-01-4050 or 39-01-4051 w/ Molex contacts 39-00-0039 (18 - 24 awg) or 39-00-0078 (16 awg) for speed control
function (supplied by customer). Non-sparking, hardened aluminum impeller.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 49


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 12.3" (312mm) Variable Speed Blower
120 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 50


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 12.3" (312mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output
219.96
8.66
12.83 [332.83]
[MM] 8.89 91.95
3.62 219.46
INCH 4X Ø.35 EXHAUST Ø8.64 BC

110.0
4.33
180.09
2X 7.09

78.65 169.93
3.10 6.69
12.39 [314.73]

COOLING AIR
DISCHARGE
Ø4.95 [Ø125.82]
INLET
Ø7.15 [181.61] ID X .13 [3.30]
.11 [2.79] INLET GROOVE
[6.35]
90.17 66.29 6X M8X1.25 .25
3.55 2.61

222.25
8.75

(1) 15-42V (OPTIONAL) (3) NOT USED


(1) 15V(SUPPLIED BY BLOWER)
3
(2) TACH OUT (2) AC INPUT
(2) TACH OUT
VOLTAGE 240±10% 2
(3) NOT USED
(3) 0-10 V SIGNAL (1) AC INPUT 1
(4) PWM SIGNAL (COMMON)
(4) NOT USED 15-45V 500-10Khz
(5) SIGNAL GROUND (5) SIGNAL GROUND

POWER CONNECTION
PWM CONNECTION
0-10 VDC CONNECTION

Part/ Model Number

Specification Units 150540 150541 150542


Speed Control - Mechanical 0-10VDC PWM

Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, single phase or 305 - 373 VDC
• Input Current: 12 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: PWM 15-45 VDC @ 500 Hz - 10 kHz; 0-10 VDC; mechanical (potentiometer); 4 - 20 mA; remote potentiometer
• Approximate Weight: 28 Lbs. / 12.7 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113
under File LR 43448.
• Miscellaneous: Designed to provide variable airflow for low NOx & CO emissions in high efficiency gas-fired combustion systems. Intake and exhaust tubes, all
cooling ducts and vents must not be obstructed. Intake and exaust must be free of grease, oil and foreign particles. Amp housing 350766-1 w/ Amp contacts 350536-1
for power connection (supplied by customer) and Molex housing 39-01-4050 or 39-01-4051 w/ Molex contacts 39-00-0039 (18 - 24 awg) or 39-00-0078 (16 awg) for speed
control function (supplied by customer). Non-sparking, hardened aluminum impeller.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 51


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 12.3" (312mm) Variable Speed Blower
240 Volt AC Input, Single Phase, Standard Output

Typical Performance

Flow (m3/hr)

20

17.5
Pressure (inch H2O)

15

Pressure (mbar)
12.5

10

7.5

5.0

2.5
0

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 52


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 12.3" (312mm) Variable Speed Blower
240 Volt AC Input, Three Phase, High Output
(1) 15-42V (OPTIONAL) (1) 15V(SUPPLIED BY BLOWER)

(2) TACH OUT (2) TACH OUT


(3) AC INPUT
VOLTAGE 240±10%

3 (3) NOT USED (3) 0-10 V SIGNAL


(2) AC INPUT
VOLTAGE 240±10% 2

1
(4) PWM SIGNAL (4) NOT USED
(1) AC INPUT 15-45V 500-10Khz
VOLTAGE 240 ±10%
(5) SIGNAL GROUND (5) SIGNAL GROUND

POWER CONNECTION PWM CONNECTION


0-10 VDC CONNECTION
219.96
8.66

91.95
12.83 [332.83]
3.62
8.89 219.46
4X Ø .35 EXHAUST Ø 8.64 BC

COOLING AIR
DISCHARGE
189.73 180.09
7.47 2X 7.09

79.75 169.93
3.14 6.69
180.34 12.39 [314.73]
Ø 7.10

Ø4.95 [Ø125.82]
INLET

Ø 7.15 [181.61] ID X .13 [3.30]


.11 [2.79] INLET GROOVE [6.35]
90.17 66.29 6X M8X1.25 .25
3.55 2.61
243.58
9.59

Part/ Model Number

Specification Units 151130 151131 151132


Speed Control - Mechanical 0-10 VDC PWM

Notes:
• Input Voltage Range: 216 - 264 Volts AC RMS, 50/60 Hz, three phase, or 305-373 VDC
• Input Current: 10 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0°C to 50°C
• Storage Temperature: -40°C to 85°C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: PWM 15-45 VDC @ 500 Hz - 10 kHz; 0-10 VDC; mechanical (potentiometer); 4 - 20 mA; remote potentiometer
• Approximate Weight: 28 Lbs. / 12.7 Kg.
• Option Card available for Customization
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Designed to provide variable airflow for low NOx & CO emissions in high efficiency gas-fired combustion systems. Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and
exaust must be free of grease, oil and foreign particles. Amp housing 350766-1 w/ Amp contacts 350536-1 for power connection (supplied by customer) and Molex housing 39-01-4050 or 39-01-4051 w/ Molex contacts
39-00-0039 (18 - 24 awg) or 39-00-0078 (16 awg) for speed control function (supplied by customer). Non-sparking, hardened aluminum impeller.
Mating harnesses available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 53


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
High Voltage Brushless DC Blowers
Nautilair (TM) 12.3" (312mm) Variable Speed Blower
240 Volt AC Input, Three Phase, High Output

Typical Performance

Flow (m3/hr)

0 212 425 637 850 1062 1274 1487 1699 1911


22.5 56

20 50
Pressure (inch H2O)

Pressure (mbar)
17.5 44

15 37

12.5 31

10 25

7.5 19

5.0 13

2.5 6
0 125 250 375 500 625 750 875 1000 1125
Flow (CFM)

10
9
Current (A)

8
7
6
5
0 125 250 375 500 625 750 875 1000 1125

11000
10000
Speed (RPM)

9000
8000

7000

6000
0 125 250 375 500 625 750 875 1000 1125

3000
Power Demand

2600
(Watts)

2200
1800
1400

1000
0 125 250 375 500 625 750 875 1000 1125

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS B 54


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
AMETEK Technical and Industrial Products’ Brushless DC Fans and Impeller-Style Blowers offer
multi-speed aerodynamic performances for all types of high airflow applications. Our standard
designs come with fully integrated electronics and are available in various input voltages includ-
ing 12 and 24 VDC (13.8 and 27.6 VDC). Environmentally resistant designs are also available for
those applications that may require exposure to natural elements. With airflow exceeding 1900
CFM, these products combine the long life expectations of brushless DC products with maximum
cooling and air moving capability.

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
www.ametektip.com
PRECISION MOTION CONTROL
Brushless DC Fans and Impeller-Style Blowers
RTP10 12/24 VDC Brushless DC Fan

2X 14 GA. (RED: +, BLACK: -)


UL3266/CSA1252
XLPE, 300V, 125°C

2X 24.00±1.00 (609.6 ±25.4)


4.77 MEASURED PERPENDICULAR TO
(121.2) MOTOR BODY

2.83
(71.9)

ROTATION
.70
(17.8)

Ø3.00 (76.2)
Ø11.28
(286.5)

AIR FLOW
1.195 (30.35)
"PULLER"

10.70
(271.8)

Part/ Model Number

Specification Units 150194-00 Puller 150194-02 Pusher


CFM 1000 940
Max Flow Rate
m3/hr 1700 1598
Voltage VDC 24 (actual 27.6) 24 (actual 27.6)

NOTES:
• These fans can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 6 lbs.
• 12.0 VDC Input avaliable

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C1


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP10 12/24 VDC Brushless DC Fan

Typical Performance

Flow (m3/hr)

27.6 VDC
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C2


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP14 24 VDC Brushless DC Fan

INCH 2X 14 GA. (RED: +, BLACK: -)


(MM) UL3266/CSA1252
5.85 XLPE, 300V, 125°C
(148.59) Ø .25
.36 2X 24.00±1.00 (609.6 ±25.4) 4X THRU (Ø 6.35)
4X (9.14)
MEASURED PERPENDICULAR TO SPACED AS SHOWN
3.65 MOTOR BODY
(92.71)

Ø 14.68
.86 (Ø 372.87)
(21.84)

14.68
2X (372.87)

Ø 3.00±0.01
(Ø 76.20±0.25)

AIR FLOW

PULLER

7.08
2X (179.83)

13.97
(354.84)

Part/ Model Number

Specification Units 150078-04 Puller


CFM 1641
Max Flow Rate
m3/hr 2789.7
Voltage VDC 24 (actual 27.6)

NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C3


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP14 24 VDC Brushless DC Fan

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

Pressure (mbar)
27.6 VDC

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C4


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP16 12/24 VDC Brushless DC Fan

Ø.25
4X (Ø6.35] THRU
SPACED AS SHOWN
16.08
5.86 [408.43]
[148.8] 8.08
2X
[205.23]
3.57
[90.7]

16"
.70
[17.8]

16.56
2X [420.62]

Ø3.00
[Ø76.2]

1.195
[30.35]
AIR FLOW

PULLER
Ø16.75
[Ø425.25]

2X 24.00±1.00
[609.6±25.4]
2X 14 GA. (RED: +, BLACK: -)
XLPE, 300V, 125°C

2X .38±.12 14 AWG LEADS (POWER)


[9.65±3.05] "RED" LEAD: +27.6 VDC
"BLACK" LEAD: RETURN

Part/ Model Number

Specification Units 150115-02 Puller


CFM 1720
Max Flow Rate
m3/hr 2924
Voltage VDC 24 (actual 27.6)

NOTES:
• These fans can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C5


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP16 12/24 VDC Brushless DC Fan

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

27.6 VDC

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C6


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP16S 12/24 VDC Brushless DC Fan

15.66
[397.76]
6.46
12.84
[164.1] Ø.25
[326.14] 4X (Ø6.35] THRU
3.50 SPACED AS SHOWN
[88.9]

.70
[17.8]

16.66
[423.16]

Ø3.00
[Ø76.2]
12.84
[326.14]

1.195
AIR FLOW [30.35]

PULLER

24.00±1.00
2X 2X 14 GA. (RED: +, BLACK: -)
[609.6±25.4]
XLPE, 300V, 125°C

2X .38±.12 14 AWG LEADS (POWER)


[9.65±3.05]
"RED" LEAD: +27.6 VDC
"BLACK" LEAD: RETURN

Part/ Model Number

Specification Units 150116-02 Puller


CFM 1920
Max Flow Rate
m3/hr 3264
Voltage VDC 24 (actual 27.6)

NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C7


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP16S 12/24 VDC Brushless DC Fan

Typical Performance

Flow (m3/hr)
Pressure (inch H2O)

27.6 VDC

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lbs/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C8


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP1300 12/24 VDC Brushless DC Impeller Style Blower

4X 12.0±1.0
(304.8±25.4) MEASURED
INCH PERPENDICULAR TO MOTOR BODY
(MM) 4X
0.38±0.12
(9.65±3.05)

4.47
(113.54)

2.24
(56.90)

13.86 0.12
5.0
(352.04) (3.05)
(127.0)

0.31 13.25 2X 14 GA. (RED: + , BLACK: - )


(7.87) (336.55) 2X 16 GA. (YELLOW & ORANGE)
4.10
8.25
(104.14) 2X 0.66 XLP, 300 V, 125°C
(209.55) (15.2)
2X OPENING
2X 0.25 5.0
(6.35) (127.0)

4.0 2.10
(101.6) (53.34)
2X OPENING
3.5
(88.9)

8X Ø 0.22 THRU
(Ø 5.59)

Part/ Model Number

Specification Units 150295-00 150222-00


Voltage VDC 12 (actual 13.8) 24 (actual 27.6)
CFM 378 378
Max Flow Rate
m3/hr 642.6 642.6

NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 12.0 VDC (11 to 18 VDC) Performance Recorded at 13.8 VDC.
24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 7 lbs.
• 12.0 VDC Input available.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C9


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP1300 12/24 VDC Brushless DC Impeller Style Blower

Typical Performance

Flow (m3/hr)

13.8 VDC
Pressure (inch H2O)

Pressure (mbar)
27.6 VDC

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C 10


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP1400 12/24 VDC Brushless DC Impeller Style Blower

4X 12.0±1.0
12.86 (304.8±25.4) MEASURED
INCH (326.64) PERPENDICULAR TO MOTOR BODY
(MM) 2X 4.30 4X
0.38±0.12
(109.22) (9.65±3.05)

2X 5.49
(139.45)

2.35
(59.69)

6.593 0.44
(167.46) 1.968 (11.18) 3.58
Ø.188 (90.93) 2X 2.67
24X (4.77) THRU (49.99) 4.10 (67.82)
1.484 (104.10) 3.84
(37.69) .826 1.219
OPENING (97.54)
(20.98) (30.96) 5.30
(134.62)
1.51
(38.35)

2.301 .889
(58.45) (22.58) 1.642 3.099
(41.71) (78.71)
5.30
(134.62) 2.674 2X 14 GA. (RED: +, BLACK: -)
(REF.) (67.92) 2X 16 GA. (YELLOW & ORANGE)
XLP, 300 V, 125°C

350.01
(13.78)

Part/ Model Number

Specification Units 150229-00 150221-00


CFM 568 619
Max Flow Rate
m3/hr 965.6 1052.3
Voltage VDC 12 (actual 13.8) 24 (actual 27.6)

NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 12.0 VDC (11 to 18 VDC) Performance Recorded at 13.8 VDC.
24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 9 lbs.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C 11


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP1400 12/24 VDC Brushless DC Impeller Style Blower

Typical Performance

Flow (m3/hr)

13.8 VDC
27.6 VDC
Pressure (inch H2O)

Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C 12


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP1600 12/24 VDC Brushless DC Impeller Style Blower

17.69±0.02 .285
(449.32±0.51) 4X Ø (7.24) THRU, SPACED AS SHOWN INCH
(MM)

2X 2.18±0.02
(55.37±0.51)
2X 3.20
(81.28)

4X 1.00 2X 14 GA. (RED: +, BLACK: -)


(25.4) 2X 16 GA. (YELLOW & ORANGE)
XLP, 300 V, 125°C
LEADS EXIT
WITHIN 12.00±1.00
QUANDRANT (304.8±25.4)
SHOWN MEASURED
PERPENDICULAR
3.95 TO MOTOR BODY
2X (100.33) INLET
0.38±0.13
4X (9.65±3.05)

4.17
2X (161.04)

2.81
4X (71.37)
3.10
2X (78.74)

5.94 0.30 3.17 0.16


2X (150.88) 2X (7.62) 2X (80.52) 4X (4.06)
16.80 3.70
2X (93.98)
(426.72)
4.17
2X(105.92)
7.34
2X(186.44)

Part/ Model Number

Specification Units 150225-00 150226-00


CFM 877 872
Max Flow Rate
m3/hr 1490.9 1482.4
Voltage VDC 12 (actual 13.8) 24 (actual 27.6)

NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for
specific set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.
• Voltage Range: 12.0 VDC (11 to 18 VDC) Performance Recorded at 13.8 VDC.
24 VDC (18 to 32 VDC) Performance Recorded at 27.6 VDC.
• Environmetally resistant design. Please discuss specific operating environmet with Marketing/Sales Department..
• Approximate Weight: 10 lbs.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C 13


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Brushless DC Fans and Impeller-Style Blowers
RTP1600 12/24 VDC Brushless DC Impeller Style Blower

Typical Performance

Flow (m3/hr)

13.8 VDC
27.6 VDC

Pressure (mbar)
Pressure (inch H2O)

Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS C 14


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
Our Seal-less Brush and Brushless Water Circulating Pumps offers four basic pump/motor
designs from 10 GPM (37.9 L/min) to 26 GPM (98.4 L/min) in either 12 VDC or 24 VDC motor
designs. Variable speed is available upon request for the brushless designs. The seal-less pump
design is magnetically coupled which provides for a leak-proof pump. There are no rotating wet
seals to wear out and leak. Detailed pump information is provided on the individual product
sheets. AMETEK seal-less pumps are not design for, and should not be used in, life sustaining
applications.

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
www.ametektip.com
PRECISION MOTION CONTROL
Pumps
10 Gallon Seal-less Pump, Brush Motor

BLAST DIRECTION DETAIL INCH


1.11 (MM) .09 Ø .80
(28.19) (2.29) (Ø 20.32)
Ø .76
CAUTION LABEL 2X 10.0±2.0
SEE NOTE 2 (254.8±50.8)
(Ø 19.30)
OUTLET
.75
(19.05)

CAUTION
150163-11 150163-21 5.14±.06
(12:00 BLAST) (3:00 BLAST) (130.56±1.52)
Ø 1.36 Ø 3.27
(Ø 34.54) (Ø 83.06)

2.38
(60.45)

.58
150163-31 150163-41 (14.73)
(6:00 BLAST) (9:00 BLAST)
3.00±.02 .36
(76.20±0.51) (9.14)

12 AWG XLPE LEAD DESIGNATION 3.42±.06


(86.87±1.52)
“RED” LEAD: +27.6 VDC +13.8 VDC
“BLACK” LEAD: RETURN RETURN 4.68±.06 4.68±.06 2.25±.02 .75±.06
(118.87±1.52) (118.87±1.52) (57.15±0.51) (19.05±1.52)
NOMINAL RATINGS 1.18±.06 4X .406±.010
(29.97±1.52) (10.31±0.25)
VO LTA GE: +27.6 VDC +13.8 VDC .281
4X (7.14)
FLOW: 10 GPM 10 GPM
AMBIENT BARB FITTING, BRASS,
TEMP RANGE: -40°C TO +85°C -40°C TO +85°C FOR Ø 1.00 I.D. HOSE
(Ø 25.4)
SPEED: 3200 RPM 3200 RPM SEE NOTE 2 1.625±.010
CURRENT: 3.0 AMPS 6.0 AMPS (117.48±0.25)
WEIGHT: 6.0 LB / 2.72 kg 6.0 LB / 2.72 kg 3.96±.06
Ø 1.01 (100.58±1.52)
(Ø 25.65)
NOTES: 1.625±.010
1. MOTOR HOUSING AND MOUNTING BRACKET MATERIAL: CRS (117.48±0.25)
MOTOR END CAPS MATERIAL: ALUMINUM AND/OR ZINC
PUMP HOUSING: POLY SULFONE PLASTIC
2. CAUTION: DO NOT RE-TORQUE INLET FITTING DURING FIELD
INSTALLATION OR REPAIR COULD RESULT IN PUMP HOUSING
DAMAGE.

Part/ Model Number

Specification Units 150163-11 150162-11


Voltage VDC 13.8 27.6
Voltage Range VDC 9-18 18-32
GPM 10 10
Flow
L/min 37.9 37.9
Current Amps (A) 6 3
Speed RPM 3200 3200
Ambient Temperature Celsius -40 deg to 85 deg -40 deg to 85 deg

NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for medium duty harsh environment applications such as shuttle bus and other medium duty transit bus applications.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibrations associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brush motor is removable from the pump without draining the coolant system.
• Approximate typical weight: 6 lbs.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D1


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
10 Gallon Seal-less Pump, Brush Motor

Typical Performance

Flow (L/min)

27.6 & 13.8 VDC

Head (meters)
Head (Feet)

Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D2


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
12 Gallon Seal-less Pump, Brushless Motor

INCH
(MM)

.81
Ø[20.62] .38±.12 2X 14 GA. (RED: +, BLACK: -)
1.29±.01 2.02
4X[51.3] .06 4.73 2.75 2X[9.65±3.05] XLPE, 300V, 125°C
[32.77±0.25] [1.52] [120.14] [69.85] MIN. SEE LEAD DESIGNATION
.75
Ø[19.05] SEPARATION POINT
OUTLET .84
.88 Ø[21.34] MOTOR ENDCAP
[22.35] 2X 304.8±25.4
[12.00±1.00]

CAUTION
5.62±.06
[142.75±1.52]
Ø3.00±.01
[Ø76.20±0.25]

2.24
[56.90]

.093±.010 MOTOR BODY


[2.36±0.25] INLET FITTING INLET COVER PUMP HOUSING
3.00±.02 1.23
[76.20±0.51] [31.24]
3.50 4.19±.06
[88.90]REF. [106.43±1.52] BASEPLATE
2.00±.06 5.69±.06 2.25±.02 1.61±.06
[50.80±1.52] [144.53±1.52] [57.15±0.51] [40.89±1.52]
.406±.010
4X [10.31±0.25]
1.19±.06
[30.23±1.52]
.281
4X [7.14]

BARB FITTING, BRASS,


FOR Ø1.00 I.D. HOSE 1.625±.010
[Ø25.4] [117.48±0.25]
3.96±.06
[100.58±1.52]
Ø1.02 1.625±.010
[Ø25.65] [117.48±0.25]

FITTING BONDED IN PLACE WITH


LOCTITE 565 THREAD SEALANT

Part/ Model Number

Specification Units 150042-11 150011-11


Voltage VDC 13.8 27.6
Voltage Range VDC 11-18 18-32
GPM 12 12
Flow
L/min 45.4 45.4
Current Amps (A) 12 6
Speed RPM 3300 3300
Ambient Temperature Celsius -40 deg to 85 deg -40 deg to 85 deg

NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for medium duty harsh environment applications such as shuttle bus and other meduim duty transit bus applications.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.
• Approximate typical weight: 8 lbs.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D3


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
12 Gallon Seal-less Pump, Brushless Motor

Typical Performance

Flow (L/min)
Head (Feet)

Head (meters)
Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D4


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
18 Gallon Seal-less Pump, Brushless Motor

IN CONNECTOR WEATHERPACK
(MM) PACKARD NO. 12010973
OR EQUIVALENT
12.0±1.0
4.62 6.0 (304.8±25.4)
4X 3/8-16 UNC-2B X 0.50 DEEP (117.4) (152.4) B A
EQUALLY SPACED AS SHOWN 4X
2.74 1.00 CORRUGATED
ON A Ø 2.312 BOLT CIRCLE LOOM
N (69.6) (25.4) STAMPING DATA
T IO
TA
O
R

3.50±0.03
Ø 3.094 (88.90±0.8)
(Ø 78.59) (MOTOR
FLATS)

1.48±0.10
2.44 (37.6±2.5)
4X (62.0)
2.312
(58.73)

Ø 1.25 .23 REF 3.89±.03


(Ø 31.8) INLET (5.84) Ø (98.8±0.8)
0.38 (MOTOR)
2.12 2X R (9.7) 0.88
(53.8) Ø (22.4) OUTLET
.45 1.35
(11.4) REF (34.3) 0.38 HOOK-UP DIAGRAM
2X 3/8-16 UNC-2B X (9.7) DEEP
1.81 SPACED AS SHOWN
(46.0)

BLAST DIRECTION OPTIONS B A


(–) RETURN (+) 27.6 VDC
BLACK RED

150178-11 150178-21 150178-31 150178-41


(12:00 BLAST) (3:00 BLAST) (6:00 BLAST) (9:00 BLAST)

Part/ Model Number

Specification Units 150299-11 150178-11


Voltage VDC 13.8 27.6
Voltage Range VDC 9-18 18-32
GPM 18 18
Flow
L/min 68.1 68.1
Current Amps (A) 10 5
Speed RPM 3100 3100
Ambient Temperature Celsius -40 deg to 85 deg -40 deg to 85 deg

NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for heavy duty harsh environment applications such as heavy duty transit bus applications.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.
• Approximate typical weight: 15 lbs.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D5


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
18 Gallon Seal-less Pump, Brushless Motor

Typical Performance

Flow (L/min)

27.6 VDC

Head (meters)
13.8 VDC
Head (Feet)

Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D6


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
26 Gallon Seal-less Pump, Brushless Motor

2X 12 AWG XLPE LEADS WEATHERPACK


2 WAY CONNECTOR PACKARD PN 12010973
INCH 2X MALE TERMINAL PACKARD PN 12124587
(MM) 3X CABLE SEAL PACKARD PN 12015193
PIN A: +27.6 VDC
PIN B: - RETURN
0.50 DEEP
4X 3/8-16 UNC-2B X (12.7) 1.40 2.750
+2.0 (35.6) (69.85)
CORRUGATED 12.0 -0.0
EQUALLY SPACED AS SHOWN LOOM 0.355±0.015
+50.8
(304.8 -00.0 ) 4X (9.02±0.38)
Ø 2.312 BOLT CIRCLE
ON A (Ø 58.72) SEPARATION 1.060±0.015
POINT 4X (26.92±0.38)
0.38 0.23 0.71
(9.65) (5.84) NAMEPLATE (18.0)

Ø 1.25 2.13
(Ø 31.75) INLET (54.1) 4.60±0.60
Ø 3.094 (116.84±1.52) 4.25 5.68
(Ø 78.59) OVER FLATS (107.95) (144.27)
3.00
(76.2)

0.93
(23.6) 0.47
2.44 .14 (11.94) 0.25
4X (61.98) 2X 3.68 4X R (6.35)
(3.6) 2.64 1.40
Ø 5.25 (67.1) (35.56) (93.47)
(Ø 133.35) 0.38 DEEP
2X 3/8-16 UNC-2B X (9.65)
4.51 6.43
(114.6) (171.7)

BLAST DIRECTION OPTIONS 1.48±0.10


(37.59±0.25)

2.312
(58.72)

0.38 Ø 0.88
2X R (9.65) (Ø 22.35) OUTLET
1.35
(34.29)
150198-11 150198-21 150198-31 150198-41 1.81
(12:00 BLAST) (3:00 BLAST) (6:00 BLAST) (9:00 BLAST)
(45.97)

Part/ Model Number

Specification Units 150393-11


Voltage VDC 27.6
Voltage Range VDC 18-32
GPM 26
Flow
L/min 98.4
Current Amps (A) 10
Speed RPM 3850
Ambient Temperature Celsius -40 deg to 85 deg

NOTES:
• Motor design characteristics are based on an operating environment of 85°C.
• Nominal and maximum performance figures are based on a windung temperature of 105°C.
• This product is designed for heavy duty harsh environment applications such as heavy duty transit bus applicatio0ns.
• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.
• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.
• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.
• Approximate typical weight: 25 lbs.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D7


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Pumps
26 Gallon Seal-less Pump, Brushless Motor

Typical Performance

Flow (L/min)

27.6 VDC

Head (meters)
Head (Feet)

Flow (GPM)
Current (A)
Speed (RPM)
Power Demand
(Watts)

Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS D8


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Controllers
All AMETEK brushless DC motors and blowers require a controller to operate. Many of these
AMETEK BLDC motors and blowers feature a built in, integrated controller that takes the DC
input from a power supply or battery and processes it into phase drive signals that are used to
commutate the motor.

Motors and blowers that require low voltage DC input (11 to 52 volts) that do not come equipped
wit an integrated, onboard controller, require on of the external controllers described in this
section.

® ®

AMETEK DYNAMIC FLUID SOLUTIONS


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258
www.ametektip.com
PRECISION MOTION CONTROL
Controllers
5 Amp BLDC Blower Controller

INCH
3.65±.01
(MM) (92.7±0.25) J1-1 Vin
1.70 MAX. J1-2 Vin Return (Gnd)
(43.2) J1-3 Analog Speed In
3.338±.015
1.00 2X .156±.010 (84.79±0.38)
(4±0.25)
(25.4) J4-1 Motor Phase A
MAX. MOLEX .156” PITCH RIGHT ANGLE
J4-2 Motor Phase C
FRICTION LOCK HEADER, SQUARE PIN
J4-3 Hall - (Gnd)
3 CIRCUIT SEE CHART (J1) 2X .53±.01
(13.5±0.25) J4-4 Hall 1
MATES WITH AMP TERMINAL HOUSING
J1 J4-5 Hall 2
770849-3 OR EQUIVALENT
J4-6 Hall 3
C17
J5 J4-7 Hall + (+12V)

1
1
J4-8 Motor Phase B
2X 2.190±.015
1
MOLEX 70553 SERIES RIGHT ANGLE HEADER (4.83±0.38) J6
J4
LOW PROFILE, SQUARE PIN, .100 CENTERS J9-1 Return (Gnd)
J3 J2
8 CIRCUIT SEE CHART (J4) J9-2 Tach Out

1
1
MATES WITH MOLEX 70066 SERIES G VERSION
3.25±.01
CONNECTOR HOUSING 50-57-9408 OR EQUIVALENT (82.6±0.25)

1
J9
1

MOLEX 6373 VERTICAL FRICTION LOCK HEADER


0.98 4X .190±.010
(24.9) SQUARE PIN, .100 CENTER, (4.83±0.25)
MAX. 2 CIRCUIT SEE CHART (J9)
MATES WITH MOLEX #22-01-2025

Part/ Model Number

Specification Units 48132


Input Voltage VDC 11-52
Max Continuous Current Amps (A) 5
Controller PWM Frequency kHz 25
Analog Speed Input VDC 0-5
Electrical Hall Spacing Degrees 60 or 120
Waveform - 6-Step Trapezoidal
Current Limit Protection - Yes
Rotation - CW / CCW

NOTES:
• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.
• Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signa l on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved
by adjusting the potentiometer when J6 is in position 1 to 2.
• Current Control: 5 Amp RMS maximum.

Jumper Settings:
J2-Motor Sensor Spacing: 120° electrical spacing with jumper connected (default).
60° electrical spacing with jumper disconnected.
J3-Rotations: Clockwise rotation with jumper connected (default).
Counter-clockwise rotation with jumper disconnected.
Do not change while motor is running or damage will occur.
J5-Input Voltage: Position 1-2 for 16-52 VDC (default).
Position 2-3 for 11-16 VDC.
J6-Speed Control: Position 1-2 for internal speed adjust, via on board potentiometer (default).
Position 2-3 for analog speed input, via 0-5 VDC signal applied to J1 pins 2 and 3.
J9: F out provides a 0-12 VDC square wave to monitor speed
(
F out (Hz) = Motor RPM
120
Motor
Poles )( )

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS E1


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Blower Application Basics

Blower Application Basics:


Figure 1: Typical System Resistance Curve - Pressure Drop vs. Flow Rate

Selecting a blower for a particular 5


application first requires knowledge or
an estimate of the application’s operat-
ing point: the flow rate required and the 4
resistance to flow that the system, duct-
work, filters, obstructions, etc., will im-

Pressure Drop
pose. This system resistance is often 3
referred to as backpressure or head
loss. The performance curves shown in
this catalog represent each model’s typ- 2 P = CQ2
ical maximum performance (full speed) P - pressure Drop
Q - flow rate
at a constant input voltage. The perfor-
C - constant for given system
mance curve describes a blower’s abil- 1
ity to deliver flow rate against
backpressure - from zero backpressure
(“open flow”) to completely blocked flow 0
(“sealed”). Since all Ametek BLDC 0 1 2 3
Flow Rate
blowers have adjustable speed control,
any operating point that lies underneath
a given performance curve can be
reached. With knowledge of the de- Figure 2: System and Blower Curves - Identifying the Operating Point
sired operating point, it is then a simple
matter to browse the catalog to identify 5
blowers having performance curves
that exceed the desired operating point.
4
Other factors should then be consid-
ered, which will be discussed hereafter. Blower performance curve

3
System Resistance Curve: A resis- Actual operating point
Pressure

tance to flow is typically characterized


by a pressure drop for a given flow rate,
2
and often follows a 2nd order relation-
ship (see Figure 1) (in some cases such
as certain filters, the relationship is 1 Desired operating point
more linear). If the desired operating System curve
point is known, then its associated sys-
tem curve can be estimated according 0
to the relationship P=CQ2. Plugging the 0 1 2 3
values for desired operating point into Flow Rate
the P (pressure drop) and Q (flow rate)
terms yields the constant C. The sys-
tem curve can then be overlaid graphi- best served by selecting the blower that • Does my application require modu-
cally onto a given blower performance delivers the desired performance with lating the speed during operation, or
curve. The intersection of the two the least amount of input power. Typi- simply a single speed adjustment made
curves is the actual operating point (see cally, the most efficient blower is the at the time of installation?
Figure 2). The pressure rise provided one where the system resistance curve • What input voltage will I have avail-
by the blower matches the pressure intersects the blower curve at approxi- able for powering the blower?
loss imposed by the system resistance. mately the middle, i.e., half the maxi- • Are there additional features that I
For quick checks, simply place the op- mum flow rate. require such as a tachometer output,
erating point on a given blower curve Other questions to consider when dynamic braking, or speed control func-
and “eyeball” the system curve through selecting a blower: tions?
it. • Will a blower of this size fit in my • Is it a problem for the working fluid
application? to come into contact with electronics?
There are likely to be several mod- • What are the environmental factors
els that can achieve the desired perfor- • Would I prefer that the blower have
mance, but not all will operate with the an on-board controller or would I prefer associated with my application?
same efficiency. The blower perfor- to provide an external controller?
mance curves in this catalog include not • Do I need a blower with fast dy- Blower Performance vs. Speed
namic response? Changes: Since Ametek’s blowers are
only pressure vs. flow rate information, speed controllable, the speed can be
but also current and input power vs. • Is loudness a major factor?
reduced to a desired operating point or
flow rate. An application is normally
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS F1


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Blower Application Basics

increased if a different operating point is H2O. The blower whose performance is Answer: At full speed, the blower will
needed in a dynamic system. Blowers shown in Figure 3 has been chosen. deliver about 8.8 cfm in this system,
conveniently have very predictable be- What will be the power consumption at whose backpressure is about 7.2 in
havior when it comes to changes in 8 cfm, 6 in H2O? H2O at that flow rate (see Figure 3).
speed. Table 1 summarizes these rela- Since this is delivering too much, the
tionships. speed must be reduced to achieve the
desired operating point.
Gage Pressure vs. Absolute Pressure: Table 1: Fan Laws Related to At full speed, Figure 3 shows the blower
Before proceeding, it’s important at this Changes in Blower Speed speed to be about 19.8 krpm and the
point to note that this tutorial makes refer-
power consumption is 18.3 W. Using

( )
ence to both “absolute pressure” and N2
“gage pressure.” Gage pressure is simply Q2 = Q1 the fan laws shown in Table 1 yields:
the difference above or below atmo- N1

( )
spheric (or barometric) pressure. Abso-

( )
lute pressure is the sum of atmospheric N2 N2
and gage pressures: m2 = m1 8 cfm = 8.8 cfm
N1 19.8 krpm
Pabsolute = Pgage + Patm N2 = 18.0 krpm
( )
2
N2
P2 = P 1
Pressure values stated hereafter are N1
gage values unless otherwise stated. So, the power consumption at the re-

( )
3
N2 duced speed is:
2 = 1
Figure 3 with Example 1 demonstrates N1
how to calculate the power requirement

( )
3
for an operating point that occurs at a Where, N fan rotational speed 18.0 krpm
reduced speed.
m•
mass flow rate 2 = 18.3 W
Q volume flow rate 19.8 krpm
Example 1: P static pressure (gage)
blower power demand
An application calls for air performance
of 8 cfm (ft3/min) at a pressure of 6 inch All other variables constant. 2 = 13.7 W

Figure 3: Speed Change Calculation Example

12 24

11 22

10 20

9 18

8 16
Pressure (in H 2O)

Input Power (W)


Speed (krpm)

7 14

6 12

5 10

4 8

3 6
blower pressure vs. flow

2 blower input power vs. flow 4


blower speed vs. flow
system resistance
1 2

0 0
0 2 4 6 8 10 12 14 16 18
Flow Rate (cfm )

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS F2


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Blower Application Basics

The speed at the desired operating sure, thereby increasing the blower’s
point could also have been found by ability to provide flow against backpres- Table 2: Fan Laws Related to
using the ratio of pressures: sure, but this is not a common practice. Changes in Fluid Density:

6 in H2O = 7.2 in H2O ( N2


19.8 krpm )
2 Fluid Density: The density of the work-
ing fluid has a significant influence on
blower performance, as can be seen in
P2 = P 1 ( ) 2
1

( )
the relationships listed in Table 2. Be-
2
cause fluid density is a variable that is 2 = 1
Note: There is some minor error in this independent of the blower, the density 1
calculation because there will likely be must be stated as part of any blower
some small change in motor efficiency
at the different operating point. This
can usually be neglected for estimating
performance specification. In the previ-
ous example, the density was ignored
for simplicity. But the performance
m2 = m1 ( ) 2
1

power requirements. curves for all blowers in this catalog


have the statement “normalized to air Where, fluid density
Static and Velocity Pressure: The density = .075 lb/ft3,” or equivalent P static pressure (gage)
energy of a fluid can be viewed as hav- statement. So, in the previous exam- power demand

ing two types of pressure: static pres- ple, it was assumed that the desired m mass flow rate
sure and velocity pressure. performance of (8 cfm, 6 in H2O) had Note: volume flow rate, Q, is independent
Static pressure is the force per unit also been normalized to .075 lb/ft3. of density for gases.
area exerted by the fluid on its sur- The density value of .075 lb/ft3 is a
roundings, and is independent of the somewhat arbitrary selection, but it is
fluid’s motion. This is the pressure that close to typical air density at sea level.tures. Because of the difference in
would be measured by a pressure sen- It is commonly referred to as “Standard viscosity between air and other gases at
sor ported normal to the direction of Density” in the fan and blower industry. the same conditions, the blower perfor-
flow. Dividing this pressure by the fluid Any target operating point must be nor- mance curves herein will have some
density yields an energy term (per unit malized to .075 lb/ft3 when evaluating error when evaluating non-air perfor-
mass) often referred to as “pressure blower performance curves in this cata- mance, even if the operating point is
head.” log. Examples hereafter demonstrate normalized to standard density. Con-
Velocity pressure is essentially the how to do this. tact Ametek engineering for help in se-
kinetic energy content, or velocity head, The vast majority of blower applica-lecting a blower for non-air applications.
of the fluid. It is the pressure that would tions are designed to move air, but Determining air density requires
result from slowing down the streamline Ametek blowers can be used with any knowing the temperature, barometric
velocity to zero, converting the kinetic non-explosive, non-corrosive gas mix- pressure, and humidity of the working
energy into pressure head. Mathemati- ture (exception - see Ametek’s Nautilair environment. Measuring temperature
cally, it takes the form P=½ 2, where series for blowers designed for combus- is relatively easy, but barometric pres-
tion pre-mix applications). Caution: sure requires a barometer, and humidity
velocity (including the density value most of the blowers in this catalog are
requires either a wet bulb thermometer,
maintains force per area, i.e., pressure not designed to be leak-proof, and
a hygrometer, or a dew point detector.
units). many vent some working fluid to cool
The sum of the static pressure and the motor. At the temperature and pres- (Note: be careful if using barometric
velocity pressure is the total pressure. sure ranges for most blower applica- values obtained from weather services -
Within a flow system, there are also tions, the gas mixture can be they are normalized for altitude and
likely to be changes in elevation considered an ideal gas, and it will be- are not the actual barometric pressure
(potential energy or elevation head) that have according to the relationship: measurements.
contribute to the energy content of the Once these values are known, the
stream at a given point. But the PM easiest way to determine density is to
changes in elevation head for gas flow RuT use a psychrometric chart, which gives
are usually small enough to be safely the properties of air for large ranges of
Where, P is the absolute pressure
ignored. temperature and humidity. (There are
is the density
The blower performance curves also on-line calculators available).
Ru is the universal gas constant
herein are plotted as static pressure (or Some notes on using a psychrometric
T is the absolute temperature
vacuum) rise vs. flow rate. The velocity chart:
M is the molar mass
pressure is typically not a useful energy 1) Instead of density, the specific vol-
quantity for overcoming resistance to ume, which is the reciprocal of density,
flow. In other words, in most cases the For gas mixtures, the molar mass of the usually is plotted.
resistance to flow results in a loss of mixture can be determined from the 2) The specific volume is typically given
static pressure of the streamline and not weighted average of the component in terms of volume per unit mass of dry
to a loss of velocity pressure. Technical- gases. Refer to texts on thermodynam- air. But the working fluid is a mixture of
ly, a diverging nozzle could be used to ics or contact Ametek engineering for air and water vapor (except at 0% hu-
convert velocity pressure to static pres- help in calculating density for gas mix- midity, of course). See the example

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS F3


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Blower Application Basics

hereafter for calculating the actual spe- reference texts and internet sites) gives Answer:
cific volume, i.e., volume per unit mass a good estimate for typical outdoor am- A) Table 2 shows that the change in
of the air-water vapor mixture. bient conditions as a function of altitude. mass flow rate is a simple ratio of the
3) Dry bulb temperature is simply the The following example demonstrates densities. If the blower speed is main-
temperature measured using a regular how to account for the lower density at tained between the two locations, the
thermometer. high altitude: mass flow rate delivered at sea level will
4) For humidity, the wet bulb tempera- be:
ture can be used directly without having Example 3: An application calls for a
to convert to another type of humidity blower to deliver 50 cfm of air at 30 inch
quantity. As an alternative, relative hu-
midity or humidity ratio can be used.
H2O at an altitude of 7000 ft above sea
level where the average air density is
m2 = 3.10 lb/min
.075 lb/ft3
.062 lb/ft3 ( )
5) Psychrometric charts are plotted at 0.062 lb/ft3, according to the Standard
m2 = 3.75 lb/min
a single barometric pressure which is Atmosphere Table. For the purpose of
noted in the heading of the chart. A selecting a blower from this catalog,
correction is needed to adjust density what operating point should be used? Mass flow rate is directly proportional to
values to the actual barometric pres- Answer: Refer to Table 2. Since vol- a change in speed (Table 1), so to
sure. ume flow rate does not change with maintain 3.1 lb/ft , the speed must be
3

density, the flow rate remains at 50 cfm. reduced by:


Example 2: A laboratory makes the The pressure does change in proportion
following measurements of the ambient to density:
air conditions: 3.10 lb/min = 3.75 lb/min ( NN )
2

1
Barometric pressure = 28.60 in Hg
( .062 lb/ft )
.075 lb/ft3
Dry bulb temperature = 72 oF
Wet bulb temperature = 65 oF
P2 = 30 inch H2O
3 ( N ) = .827 = 17.3% reduction
N2
1

What is the ambient density? P2 = 36.3 inch H2O


B) Since volume flow rate is indepen-
Answer: Using a psychrometric chart So, the operating point normalized to dent of density, the volume flow rate will
plotted at 29.921 in Hg, the intersec- standard density is 50 cfm, 36.3 inch not change between the two locations if
tions of the curves corresponding to the H2O. the speed remains constant. This illus-
dry bulb and wet bulb values above trates the difference between the quan-
yields a specific volume of 13.64 ft3/lbdry Example 3 continued: A blower is se- tities of volume flow and mass flow - a
air and a humidity ratio of .0116 lbwater- lected from the catalog that can deliver factor that must be kept in mind when
vapor per lbair. Correct the specific vol- the above performance with a power evaluating an application’s air perfor-
ume per lb air-water vapor mixture: demand of 600 W at standard density, mance needs.
as shown on the published performance
mwv curves. What will be the power demand C) Tables 1 and 2 show that the power
mair = .0116 at the intended location at 7000 ft alti- demand is directly proportional to both
tude? density and speed, although a speed
mmixture = mwv + mair change has a much larger influence.
Answer: Refer to Table 2 for correcting Combining both relationships yields:
= .0116mair+ mair
= 1.0116mair
power demand for a change in density.
3
mair
mmix
= .989 2 = 1 ( )( NN )
2 2

.075 lb/ft )
( .062 lb/ft3 1 1
2 = 600 W 3
.989(13.64 ft3/lbair) = 13.49 ft3/lbmix 3

2 = 496 W 2 = 1 (.062
.075 lb/ft
lb/ft
) (.827)
3

Finally, correcting this value for the ac- Example 3 continued - Redefining the
tual barometric pressure yields: 2 = .684 1 = 31.6% reduction
problem in terms of mass flow rate: The
application requires a mass flow rate of
13.49 ft3/lbmix (
29.921 in Hg
28.60 in Hg ) 3.1 lb/min of air regardless of altitude.
A) How much must the speed be re- Incompressible Flow: Although the
density of the working fluid is a variable
duced if the application is moved from a
= 14.12 ft3/lbmix location at 7000 ft (.062 lb/ft3) to sea that must be accounted for, in a given
level (.075 lb/ft3)? application the density is assumed to be
= .0708 lbmix/ft3 B) If the speed is not adjusted to com- constant for applications involving the
pensate for the change is density, what blowers herein. In other words, for a
will be the change in volume flow rate given blower in operation the fluid enter-
The density of air varies substan- between the two locations? ing the blower has the same density as
tially with weather and altitude. The C) How much will the power demand the fluid leaving the blower. Another
Standard Atmosphere Table (not in- change? term for this is “incompressible flow.”
cluded herein, but widely available in Density variations are less than one

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS F4


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Blower Application Basics

percent for flow speeds less than Mach vapor is not a problem as long as it does THE FAILURE TO OBSERVE THE
= 0.2, which is greater than typical ap- not condense into liquid water inside the FOLLOWING SAFETY PRECAU-
plications for these blowers. blower. TIONS COULD RESULT IN SERIOUS
BODILY INJURY, INCLUDING DEATH
Blower Life: Brushless DC blowers Mechanical Shock: Mechanical IN EXTREME CASES. We recommend
have the advantage of long life com- shock can cause denting of the that adequate instructions and warnings
pared to blowers driven by brush mo- bearing’s rolling elements. This results by the original equipment manufactur-
tors. Since the motor is electronically in unwanted noise and can lead to flak- ers (OEM) include labels setting forth
commutated there are no brushes to ing and pitting inside the bearing. Appli- the precautions listed below to the end
wear out, so the end of life scenario for cations that subject the blower to user.
brushless blowers is normally bearing mechanical shock should be thoroughly The motors and/or blowers must be
failure. tested to ensure adequate life. connected to a proper and effective
Since long life is one of the main ground or mounted in a manner that will
attributes of brushless technology, the Operating point: The amount of back- guarantee electrical isolation and insu-
question “How long will it last?” is com- pressure a blower works against is an- late the user and others from electric
mon. Unfortunately, there is no simple other influencing factor in some blower shock. End product design should not
answer to this question. There are a models. The backpressure results in a rely solely on the primary insulation of
number of factors that influence life, and pressurized blower housing, putting a the motor.
we currently have no way to account for pressure gradient across the adjacent Standard blowers and/or motors
every possible application. The primary bearing. The pressure gradient tends to are not designed to handle volatile or
factors that influence life are: push the grease out and contamination flammable materials through the fan
in. Ametek has implemented design system unless specifically designed.
• temperature features to minimize this effect, and the Passing combustible gases or other
• bearing contamination customer should not be hesitant to op- flammable materials through the fan
• mechanical shock erate at high pressure if the application system could result in leakage which
• operating point calls for it. could cause a fire or explosion.
These products must not be used in
Temperature: The deterioration of Again, blower life is highly applica- an area contaminated by volatile or
bearing grease is directly proportional tion dependent. Customer requests for flammable materials since sparking is
to its temperature. So, the higher the MTTF (Mean Time To Failure) informa- predictable in the normal operation of
temperature, the shorter the bearing tion are difficult to answer. Moreover, the motor and may ignite the volatile
life. There is no hard limit on bearing what constitutes a failure is often open causing a dangerous explosion.
temperature, but just a general rule that to interpretation. For example, there The Technical and Industrial Prod-
cooler is better. There is a point of can be situations where a blower is ucts Division of Ametek, Inc. can supply
diminishing returns that is application delivering air performance as required, specifically designed motors and blow-
dependent - reducing temperature is but it has deteriorated bearings that ers for use in handling combustible
unnecessary if the blower life is ade- produce unacceptable noise for sound- gases or for use in hazardous duty
quate for the application. A rule of critical applications. locations. These specially designed
thumb for Ametek blowers is 45 oC Ametek does conduct an ongoing units should only be used in conjunction
maximum ambient temperature, but this life test program to gather life informa- with combustible gases, which they
can be exceeded under certain circum- tion and to improve the durability of our were specifically designed to handle.
stances. Please consult Ametek engi- blowers. Tests are conducted on blow- The type of gases must be so noted on
neering for applications a high ers that represent all model families. the product label and in the instructions.
temperatures. Ultimately, it is up to the History has shown that Ametek blowers The rotation of the motor shaft, or
customer to determine whether or not a survive beyond 10,000 hours of contin- anything mounted on the shaft, is a
blower can provide adequate life. Thor- uous running in typical applications. It potential source of injury and must be
ough testing is recommended. Also is common for blowers to endure more taken into account in the design of your
keep in mind that extreme temperature than 20,000 hours, and some blowers end product. You must provide the
can cause premature failure of electron- have accumulated 30,000+ hours. But necessary guarding or housing as re-
ics or the motor winding. again, it must be stressed that blower quired by the finished product and you
life is application dependent, and the must indicate to the user the direction of
Bearing Contamination: The introduc- customer is encouraged to conduct a rotation. Do not remove guard as se-
tion of particulate matter increases the life test in-situ under the application’s vere bodily injury may occur to fingers
rolling friction of the bearing, which in- most rigorous conditions. The life val- or appendages.
creases temperature. Particulates also ues mentioned above are not to be Products incorporating vacuum
scar the surface of the bearing race- used as a basis for warranty claims. motors/blowers must be designed so as
ways and balls, which increases pitting to prevent the vacuum or air pressure
and flaking, further exacerbating the Safety Bulletin: In the applica- from being concentrated in a manner
condition. Corrosive gases can react tion of Ametek, Inc. motors and/or blow- that can expose the user to injury by
negatively with grease or cause corro- ers as a component in your product, you coming into contact with any body area,
sion of the steel in the bearings. Liquids must exercise the following minimum such as eyes, ears, mouth, etc.
of any kind should be avoided. Water precautions:

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS F5


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com
Blower Application Basics

Unit Conversions
Density: 1 lbm/ft3 = 16.03 kg/m3
Length: 1 ft = 12 inch = .01602 g/cm3
= .3048 m
= 30.48 cm Energy: 1 ft•lbf = 1.356 J
= .0001894 mile = 1.356 N•m
= .001285 Btu
Volume: 1 ft3 = .02832 m3
= 28.32 L Power: 1 W = .00134 hp
= 7.481 gal = 3.413 Btu/hr
= 550 (ft-lbf)/s
Mass: 1 lbm = .4536 kg
Temperature: T (oR) = T(oF) + 459.7
Force: 1 lbf = 32.174 lbm•ft/s2 = 1.8[T(oC + 273.15]
= 4.448 N = 1.8T(K)

Volume Flow Rate: 1 cfm (ft3/min) = 28.32 L/min Universal Gas Constant, Ru: = 10.73 psia•ft3/(lbmol•oR)
= 1.699 m3/hr = 1545 ft•lbf/(lbmol•oR)
= 8.314 kJ/(kgmol•K)
Pressure: 1 inch H2O = .249 kPa = 8.314 kPa•m3/(kgmol•K)
= 2.49 mbar
= .0361 psi ( l b f /in 2 )
= .0735 inch Hg

The motors and/or blowers must be disconnected before examination


not be exposed to moisture or liquid or and/or removal from the system.
used outdoors, except in equipment Contact Ametek, Inc. to discuss any
which is specifically designed for out- questionable application before select-
door use and meets the appropriate ing a standard motor or blower.
regulatory agency requirements for out- In setting forth the above listed
door use. Moisture or liquid can dam- recommendations with regards to pre-
age the motor/blower and defeat the cautionary steps that must be consid-
electrical insulation resulting in a severe ered, we in no way intend to imply that
electrical shock to the user. if these steps are taken a product will
Ametek motors/blowers must not meet the applicable safety standards.
be operated above the design voltage. We, at Ametek, are not sufficiently con-
Over voltage conditions can cause ex- versant with the specific safety hazards
cessive speed of the motor and can which may be associated with particular
result in severe electrical shock and/or products. We can only advise precau-
other traumatic injury to the operator. tions to be employed generally for the
Precautions must be exercised to safe use of Ametek products as compo-
ensure motor leads are properly routed nents. For testing specifically related to
and connected in your equipment. the safety of the product, we recom-
Lead wires must be routed and retained mend that you contact the appropriate
to ensure that they do not become regulatory agency as indicated by the
pinched or come in contact with rotating type of product being manufactured.
parts during assembly or subsequent
operations. Connections must be de-
signed so that proper electrical contact
is established and the connections must
be properly insulated.
Disassembly or repairs of Ametek
products should not be attempted. If
accomplished incorrectly, repairs can
create an electrical shock and/or opera-
tional hazard. It is recommended that
repairs be made only by Ametek and
not by others.
In the event that the motor or
blower ceases to operate, power must

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Dynamic Fluid Solutions Sales
department.

AMETEK DYNAMIC FLUID SOLUTIONS F6


100 E. Erie Street, Kent OH 44240
USA: +1 215-256-6601 - Europe: +49 7703 930 909 - Asia: +86 21 5763 1258 ____ PRECISION MOTION CONTROL
www.ametektip.com