40 CONTROLS
Control Systems 41
Interface 42
Central Station 43
The information contained in this catalog is for illustration purposes only and is subject to change at the sole discretion
of Johnson Controls. Statements, figures, calculations, plans, images and representations are only examples. Johnson
Controls encourages you, as the purchaser, to analyze your HVAC requirements and to work with Johnson Controls to
determine the exact VRF System to fulfill your needs.
2 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 1
Introducing YORK® VRF from Johnson Controls
YORK® VRF systems are modular and controlled Gain control flexibility
solutions that include models with capability to Users can deploy from three basic control options.
heat or cool different zones.
• Indoor fan coil units come with a selection of thermostats, from simple
The technology brings an array of advantages over conventional units with on/off, setpoint, load and speed settings, to programmable
systems. units that enable scheduling. Wireless units are available to provide
remote control of zone space conditions.
• Save on energy. Systems essentially eliminate duct losses. In addition,
variable-speed compressors in outdoor units provide extremely high • Central station controllers for larger projects provide remote control
part-load efficiency. and scheduling of the entire system from one or more control points.
• Keep people comfortable. Users can set individual temperature • Adapters (gateways) enable control of large buildings or campuses
set points for multiple zones. Variable-speed compressors with through building automation systems such as Metasys®.
wide capacity and precise modulation help maintain each zone’s
temperature within a narrow range. Indoor units also operate quietly. Choose multiple applications
• Go green. VRF technology can help users attain LEED® certification YORK® VRF systems suit a wide range of buildings in new construction
points for resource efficiency. and retrofits. Prime candidates include:
• Buildings with multiple zones that have different comfort needs –
Enjoy design freedom such as hotels, schools, medical office buildings, commercial office
A variety of standard modular components let you customize and buildings and others.
size equipment to meet specific project requirements. Because • Historical building renovations in which ducted HVAC options are
ductwork is generally needed only for ventilation, ducts can be smaller, severely limited and the basic building structure must not be disturbed.
reducing capital cost. Systems can easily be adapted as space is
• Buildings in climate zones favorable for heat pump technology.
reconfigured. Unlike conventional HVAC systems, VRF systems allow
addition of capacity to accommodate expansion simply by adding
modular units (capacities 10-39 HP). There is no need to remove and
replace the original unit or reconfigure ductwork.
2 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 3
Advanced compressor technology yields the highest efficiency How VRF works
ratings resulting in energy savings
A VRF system typically consists of one or more outdoor condensing
units from which refrigerant is piped to a series of indoor fan coil units
Rated highest for energy efficiency
serving individual zones within building spaces. The system conditions
The YORK® VRF Systems boast YORK® systems rank impressively high in the ratings that matter most the spaces by delivering to the indoor fan coil units only the volume
for VRF technology. The traditional measure of HVAC equipment, energy of refrigerant required to meet the heating or cooling needs of each
efficiencies up to:
efficiency ratio (EER), measures system efficiency at full load. While this zone (see Figure 1).
• 4.65 EER may be appropriate for equipment that operates in a traditional cycle (fully
The basic types of YORK® VRF Water Cooled systems, ranging
on or fully off), it is not appropriate for properly sized VRF systems, which
from 10-30 HP capacity:
spend the vast majority of time at part load, reaching full load only on the
hottest or coldest days. YORK® VRF systems excel against truer measures • Heat pump VRF systems are two-pipe systems
of efficiency:
The core technology of YORK® VRF systems is the exclusive Hitachi- Heat pump VRF systems are two-pipe systems that
designed high-efficiency scroll compressor. Hitachi invented the first air enable design for ductless or ducted applications. Precise
conditioning scroll compressor in 1983 and in 2008 applied a cutting- heating or cooling is delivered to multiple zones.
edge large-capacity scroll compressor to VRF technology. Its advantages
include a high compression ratio, excellent reliability and efficiency, and
lower compressor noise level.
Figure 1
4 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 5
Get expert advice at every step: select, design, specify, install Get the tools that give you an edge
Your Johnson Controls account team supports you as no one else Right-size systems with intuitive selection software
can, at every step of every project. Effective training, intuitive design YORK ® VARIABLE REFRIGERANT FLOW
The PC-based program gives you mobility and flexibility. The software
Comprehensive training programs provide knowledge and skills
helps you:
necessary to effectively and efficiently deploy YORK® VRF
technology. Our world-class VRF training center offers a multitude of • Design accurate final system drawings including piping and wiring
classes with specialized modules and topics that help: diagrams in an easy, quick, step-by-step process.
• Salespeople submit competitive bids and close deals. • Accurately select systems using a System Sizing Analysis. The process
starts with the indoor fan coil units, so that outdoor units are optimally
• Designers select and configure the right equipment easily
sized. Proprietary algorithms figure the system size using data input
and accurately.
on the indoor units, load, and measurements, so your system does
• Installers learn the proper procedures and complete jobs not include capacity that will go unutilized.
accurately, on time and on budget. • Use intuitively designed features and functionality that make the
• Service technicians maintain, troubleshoot and repair systems design process easy, fast, and accurate. You can select options and
efficiently. accessories without referring to additional information or performing
additional calculations.
The training center includes a dedicated VRF laboratory to provide
• Gain an edge by confidently designing VRF systems that are right-
hands-on experience with the various systems, components and
sized, and include the right equipment for each project.
controls. YORK® VRF training programs help deliver peace of mind that
your staff is prepared to support your business with the knowledge to
compete in a growing industry.
6 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 7
Get winning advice to make the best decisions
Consistent delivery: YORK® VRF systems bring exciting new possibilities in building space
Get the right equipment to the jobsite on time conditioning, enabling you to satisfy customers, win more business,
and enhance your reputation. When you work with Johnson Controls
Ample inventory and advanced order management and logistics
as your partner, our experts can guide you through a thorough analysis
systems can help you complete installations in a timely manner.
to select the system that best delivers exceptional energy efficiency,
Consistent service and predictable deliveries help you prevent delays
increased occupant comfort, and a lower life-cycle cost. You can choose
waiting for essential components and enable you to set a project timeline
from a wide portfolio of HVAC solutions including:
and schedule labor efficiently. Fast and accurate parts delivery from our
• YORK® VRF systems
main distribution center.
• YORK® chillers
• YORK® rooftop units YORK® VRF systems
Let’s go to work – together • YORK® custom built-up air handlers
• Metasys® building automation systems
YORK® VRF systems can be configured to meet your project
requirements and deliver exceptional performance. Select heat Our analysis will provide data that helps you appropriately compare all
pump or cooling only outdoor units with DC inverter-driven compressors options, so you can make the best-informed decision on every project.
offering energy savings and the ability to scale to size. Multiple
ventilation options help make sure your systems introduce the right
volume of outside air. A host of options and accessories help ensure a
custom fit for your project. And users benefit from our variety of control
technology options. YORK® Chillers
8 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 9
YORK® VRF Systems: Summary of Features and Benefits
System
• Provides flexibility to customize systems to each • Simplify projects
Modular System Efficiency optimized for
project’s needs • Allows easier adaptation and expansion of the installation • Lower energy consumption with partial loads • Saves energy
part-load operation
• Provides better installation flexibility • Reduces system costs
Ductless systems • Extremely quiet (sound ratings as low as 27
• Greater free area between floor and ceiling • Ideal for historic renovations
dBA for indoor units)
Noise reduction preference • Lets users choose from three settings
• Accommodates retrofits by making use of mode for a “not to exceed” sound level • Ideal where outdoor units are positioned on
existing duct infrastructure side of building or in locations where there are
Ducted systems • Reduces overall construction costs noise restrictions
• Suits unique buildings that include ducted and
ductless areas
DC inverter-driven scroll • Engineered to deliver the optimum efficiency
Compressor
Heat pump VRF systems • Precisely heats or cools multiple zones • Provides extreme system design flexibility • Among industry’s most efficient VRF systems
compressor at normal load conditions
Comprehensive training • Specific training to YORK VRF Selection System • Enables effective equipment selection and specification
• Fast, easy and intuitive selection of the • Allows equipment selection and system pipe line Compressor modulation • Smoothly delivers only the exact amount of • Allows fine control for optimum comfort
System selection software
in 1 Hz increments refrigerant needed for the load
BUILDING OWNER
equipment dimensioning. • Saves energy
• Users can select from a wide variety of power • Limits electric demand charges
Outdoor Units
Demand control settings from 100% to 60% and program “not to • Limits electric consumption
exceed” a given power level • Reduces noise
• Pipe line can be connected to the outdoor unit • Reduces installation time and cost
CONTRACTOR / INSTALLER
• Specific training to installation and operation of • Provides an installation with higher speed and quality
Comprehensive training
the York VRF System
Indoor Units
As high as .74 WG static • Offers adjustable speeds to match the static pressure • Flexibility to accommodate long or short
• Enhances installation efficiency pressure in ducted systems requirement ductwork runs
Consistent, reliable product • Ensures correct components are delivered to
delivery job sites on time • Allows efficient labor scheduling
Optional motion and • Sets back temperature when space is unoccupied, • Saves energy
• All components accessible via removal of one • Speeds up time spent on maintenance, repair, radiant sensors increasing efficiency even further • Protects occupant comfort
Easy maintenance access and troubleshooting
panel
• Controls multiple indoor and outdoor units from one • Maximizes indoor comfort
control point
H-Link II Protocol • Saves energy
• Adds versatility to connect various central control
options • Improves system management
Controls
• Auto-adjusts for daylight saving time
• Adjusts in 1 degree F increments
Temperature control • Provides options to satisfy multiple projects/
• Adjustable fan speeds
buildings
10 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 11
YORK® VRF INDOOR UNITS
Choose the style and size from the wide selection of indoor units
to meet your requirements for layout and design.
Indoor Units
YORK® VRF indoor units operate quietly 4-Way Cassette
and are easy to install, service and 2-Way Cassette High Static and Medium Ducted Ducted Low Static Ducted Slim
Wall Mounted JTDM022H0NB0AQ JTDH084H0NB0AQ JTDL022H0NB0AQ JTDL071H0NB0AQ JTDN022H0PB0AQ JTDN063H0PB0AQ
maintain. A wide variety of ductless and JTDM028H0NB0AQ JTDH090H0NB0AQ JTDL028H0NB0AQ JTDL084H0NB0AQ JTDN028H0PB0AQ JTDN071H0PB0AQ
Floor Concealed JTDM036H0NB0AQ JTDH112H0NB0AQ JTDL036H0NB0AQ JTDL090H0NB0AQ JTDN036H0PB0AQ JTDS022H0PB0AQ
ducted units are available in styles and JTDM043H0NB0AQ JTDH142H0NB0AQ JTDL043H0NB0AQ JTDL112H0NB0AQ JTDN043H0PB0AQ JTDS028H0PB0AQ
Floor Exposed
JTDM050H0NB0AQ JTDH160H0NB0AQ JTDL050H0NB0AQ JTDL142H0NB0AQ JTDN050H0PB0AQ JTDS036H0PB0AQ
capacities to fit multiple applications. Units High Static and Medium Ducted JTDM056H0NB0AQ JTDH224H0NF0AQ JTDL056H0NB0AQ JTDL160H0NB0AQ JTDN056H0PB0AQ JTDS043H0PB0AQ
JTDM063H0NB0AQ JTDH280H0NF0AQ JTDL063H0NB0AQ
operate quietly with sound ratings as low as Ducted Low Static JTDM071H0NB0AQ
JTDM224H0NF0AQ
27 dBA. Ducted Slim JTDM280H0NF0AQ
12 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 13
YORK® VRF INDOOR UNITS
4-Way
Cassette
2-Way
Cassette
Wall
Mount
Ducted
High and
Medium Static
Ducted
Low
Static
Ducted
Slim
4-Way Cassette Indoor Unit
Floor Ceiling mounted 4-way cassettes measuring 33 x 33 inch (84 x
Concealed 84 cm) are offered with standard decorative panels. Compact,
thin and lightweight, they are easy to install even in tight spaces.
Floor
Exposed Key Features
• Optional motion and radiant heat sensors for shutoff and activation in
response to room occupancy. Capacities: 2.8 to 16kW
14 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 15
YORK® VRF INDOOR UNITS
Model JTKF028H0PS0AQ JTKF036H0PS0AQ JTKF043H0PS0AQ JTKF050H0PS0AQ Model JTKF056H0PS0AQ JTKF063H0PS0AQ JTKF071H0PS0AQ JTKF080H0PS0AQ
Indoor Unit Power Supply AC 1Φ,220-240V/50Hz AC 1Φ,220V/60Hz Indoor Unit Power Supply AC 1Φ,220-240V/50Hz AC 1Φ,220V/60Hz
23 23 23 24 24 24 24 26
Net Weight kg (Ibs.) Net Weight kg (Ibs.)
(51) (51) (51) (53) (53) (53) (53) (57)
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance) Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan m3/min. Indoor Fan m3/min. 16/14/12 19/17/14 20/17/15 26/23/20
13/12/11 15/13.5/12 15/13.5/12 16/14/12
Air Flow Rate (Hi/Me/Lo) Air Flow Rate (Hi/Me/Lo) (cfm) (565/494/424) (671/600/494) (706/600/530) (918/812/706)
(cfm) (459/424/388) (530/477/424) (530/477/424) (565/494/424)
Motor W 56 56 56 56 Motor W 56 56 56 56
Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Connections mm
mm Refrigerant Piping
Refrigerant Piping Φ6.35 Φ9.53 Φ9.53 Φ9.53
Φ6.35 Φ6.35 Φ6.35 Φ6.35 (in.)
(in.) Liquid Line
Liquid Line (1/4) (3/8) (3/8) (3/8)
(1/4) (1/4) (1/4) (1/4)
mm Φ15.88 Φ15.88 Φ15.88 Φ15.88
mm Φ12.7 Φ12.7 Φ12.7 Φ15.88 Gas Line
Gas Line (in.) (5/8) (5/8) (5/8) (5/8)
(in.) (1/2) (1/2) (1/2) (5/8)
Condensate Drain VP25 VP25 VP25 VP25
Condensate Drain VP25 VP25 VP25 VP25
Approximate Packing Measurement m 3
0.22 0.22 0.22 0.26
Approximate Packing Measurement m3 0.22 0.22 0.22 0.22
Adaptable Panel Model JP-N23NAQ JP-N23NAQ JP-N23NAQ JP-N23NAQ
Adaptable Panel Model JP-N23NAQ JP-N23NAQ JP-N23NAQ JP-N23NAQ
Color Neutral White
Color Neutral White
37 37 37 37
37 37 37 37 Height mm (in.)
Height mm (in.) (1-7/16) (1-7/16) (1-7/16) (1-7/16)
(1-7/16) (1-7/16) (1-7/16) (1-7/16)
950 950 950 950
950 950 950 950 Outer Dimensions Width mm (in.)
Outer Dimensions Width mm (in.) (37-3/8) (37-3/8) (37-3/8) (37-3/8)
(37-3/8) (37-3/8) (37-3/8) (37-3/8)
950 950 950 950
950 950 950 950 Depth mm (in.)
Depth mm (in.) (37-3/8) (37-3/8) (37-3/8) (37-3/8)
(37-3/8) (37-3/8) (37-3/8) (37-3/8)
6 6 6 6
6 6 6 6 Net Weight kg (lbs.)
Net Weight kg (lbs.) (13) (13) (13) (13)
(13) (13) (13) (13)
Approximate Packing Measurement m3 0.08 0.08 0.08 0.08
Approximate Packing Measurement m3 0.08 0.08 0.08 0.08
NOTES:
NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS standard B8616.
1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB)
Indoor Air Inlet Temperature: 27°C DB (80°F DB)
*1) 19.5°C WB (67°F WB)
*1) 19.5°C WB (67°F WB)
*2) 19.0°C WB (66.2°F WB)
*2) 19.0°C WB (66.2°F WB)
Outdoor Air Inlet Temperature: 35°C DB (95°F DB)
Outdoor Air Inlet Temperature: 35°C DB (95°F DB)
Heating Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Outdoor Air Inlet Temperature: 7°C DB (45°F DB)
Outdoor Air Inlet Temperature: 7°C DB (45°F DB)
6°C WB (43°F WB)
6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
2. The sound pressure level is based on following conditions.
1.5 Meter Beneath the Unit.
1.5 Meter Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
16 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 17
YORK® VRF INDOOR UNITS
18 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 19
YORK® VRF INDOOR UNITS
Capacities: 2.2 to 16 kW
20 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 21
YORK® VRF INDOOR UNITS
Features
• High-efficiency DC fan motor
• Multiple fan speed settings
Capacities: 2.2 to 6.3 kW • Up to 30 pa static pressure
• Bottom access for easy service and troubleshooting
Wall Indoor Unit (continued) • Built-in condensate pump
Capacities: 2.2 to 28 kW
22 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 23
YORK® VRF INDOOR UNITS
Ducted Low Static Indoor Unit (continued) Ducted Low Static Indoor Unit (continued)
Indoor Unit Type In-the-Ceiling Type (Low Static Pressure) Indoor Unit Type In-the-Ceiling Type (Low Static Pressure)
Model JTDL056H0NB0AQ JTDL063H0NB0AQ JTDL071H0NB0AQ JTDL084H0NB0AQ JTDL090H0NB0AQ Model JTDL112H0NB0AQ JTDL142H0NB0AQ JTDL160H0NB0AQ JTDL224H0NF0AQ JTDL280H0NF0AQ
Indoor Unit Power Supply AC 1Φ,220V/60Hz Indoor Unit Power Supply AC 1Φ,220V/60Hz AC 1Φ,220V/60Hz AC 3Φ,380-415V/60Hz
kW 5.8 6.5 7.3 8.7 9.3 kW 11.6 14.5 16.5 23.2 28.6
Nominal Cooling Capacity*1) kcal/h 5,000 5,600 6,100 7,500 8,000 Nominal Cooling Capacity*1) kcal/h 10,000 12,500 14,200 20,000 24,600
Btu/h 19,800 22,200 25,000 29,700 31,700 Btu/h 39,700 49,500 56,300 79,200 97,600
kW 5.6 6.3 7.1 8.4 9.0 kW 12.6 14.2 16.0 22.4 28.0
Nominal Cooling Capacity*2) kcal/h 4,800 5,400 6,100 7,200 7,700 Nominal Cooling Capacity*2) kcal/h 9,600 12,200 13,800 19,300 24,100
Btu/h 19,800 21,500 24,200 28,700 30,700 Btu/h 38,000 48,400 54,600 76,500 95,600
kW 6.5 7.5 8.5 9.6 10.0 kW 13.0 16.3 18.0 25.0 31.5
Nominal Heating Nominal Heating
kcal/h 5,600 6,500 7,300 8,300 8,600 kcal/h 11,200 14,000 15,500 21,500 27,100
Capacity Capacity
Btu/h 22,200 25,600 29,000 32,800 34,100 Btu/h 44,400 55,500 61,400 85,300 107,500
mm 270 270 270 350 350 mm 350 350 350 470 470
Height Height
(in.) (10-5/8) (10-5/8) (10-5/8) (13-3/4) (13-3/4) (in.) (13-3/4) (13-3/4) (13-3/4) (18-1/2) (18-1/2)
mm 900+75 900+75 900+75 900+75 900+75 mm 900+75 1,300+75 1,300+75 1,060 1,250
Outer Dimensions Width
Outer Dimensions Width (in.) (35-7/16+2-15/16) (51-3/16+2-15/16) (51-3/16+2-15/16) (41-3/4) (49-1/4)
(in.) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16) (35-7/16+2-15/16)
mm 800 800 800 1,120 1,120
mm 720 720 720 800 800 Depth
Depth (in.) (31-1/2) (31-1/2) (31-1/2) (44-1/12) (44-1/12)
(in.) (28-3/8) (28-3/8) (28-3/8) (31-1/2) (31-1/2)
kg 46 58 58 96 106
kg 35 35 35 46 46 Net Weight
Net Weight (Ibs.) (101) (128) (128) (207) (234)
(Ibs.) (77) (77) (77) (101) (101)
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Indoor Fan
Indoor Fan m3/min. 27/23/19 37/31/25 38/35/29 58 72
m3/min. 15/13/11 16/14/12 16/14/12 25/21/17 7225/21/17 Air Flow Rate
Air Flow Rate (cfm) (954/812/671) (1,306/1,095/883) (1,341/1,236/1,024) (2048) (2542)
(cfm) (530/459/388) (565/494/424) (565/494/424) (883/741/600) (883/741/600) (Hi/Me/Lo)
(Hi/Me/Lo)
External Pressure *3) pa 60 60 60 100 100
External Pressure *3) pa 30 30 30 60 60
24 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 25
YORK® VRF INDOOR UNITS
Ducted High and Medium Static Indoor Unit Ducted High and Medium Static Indoor Unit (continued)
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
Liquid Line
(in.) (1/4) (1/4) (1/4) (1/4) (1/4)
mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Gas Line
(in.) (1/2) (1/2) (1/2) (1/2) (5/8)
Approximate
m3 0.21 0.21 0.21 0.21 0.27
Packing Measurement
26 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 27
YORK® VRF INDOOR UNITS
Ducted High and Midium Static Indoor Unit (continued) Ducted Slim Narrow Indoor Unit
Indoor Unit Type In-the-Ceiling Type (High Static Pressure)
Features
Model JTDH112H0NB0AQ JTDH142H0NB0AQ JTDH160H0NB0AQ JTDH224H0NF0AQ JTDH280H0NF0AQ
• High-efficiency DC fan motor
Indoor Unit Power Supply AC 1Φ,220V/60Hz AC 1Φ,220V/60Hz AC 3Φ,380-415V/60Hz • Multiple fan speed settings
Nominal Cooling
kW 11.6 14.5 16.5 23.2 28.6 • Up to 30 pa static pressure
Capacity*1)
kcal/h 10,000 12,500 14,200 20,000 24,600 Capacities: 2.2 to 4.5 kW
Btu/h 39,700 49,500 56,300 79,800 97,600 • Bottom access for easy service and troubleshooting
kW 11.2 14.2 16.0 22.4 28.0
Nominal Cooling • Built-in condensate pump
kcal/h 9,600 12,200 13,800 19,300 24,100
Capacity*2)
Btu/h 38,000 48,400 54,600 76,500 95,600
kW 13.0 16.3 18.0 25.0 31.5
Nominal Heating
kcal/h 11,200 14,000 15,500 21,500 27,000
Capacity Indoor Unit Slim In-the Ceiling Type
Btu/h 44,400 55,500 61,400 85,300 107,000
Model JTDS022H0PB0AQ JTDS028H0PB0AQ JTDS036H0PB0AQ JTDS043H0PB0AQ
Sound Pressure Level
dB (A) 43-40-36 44-41-37 45-41-37 50 52 Power Supply AC 1Φ,220V/60Hz
(High/Medium/Low)
mm 350 350 350 470 470 KW 2.3 2.9 3.8 4.4
Height
(in.) (13-3/4) (13-3/4) (13-3/4) (18-1/2) (18-1/2) Nominal Cooling Capacity *1 kcal/h 2,000 2,500 3,300 3,800
Outer mm 900+75 1,300+75 1,300+75 1,060 1,250 Btu/h 7,800 9,900 13,000 15,000
Width
Dimensions (in.) (35-7/16+2-15/16) (51-3/16+2-15/16) (51-3/16+2-15/16) (41-3/4) (49-1/4)
kW 2.2 2.8 3.6 4.3
mm 800 800 800 1,120 1,120
Depth Nominal Cooling Capacity *2 kcal/h 1,900 2,400 3,100 3,700
(in.) (31-1/2) (31-1/2) (31-1/2) (44-1/2) (44-1/12)
Btu/h 7,500 9,500 12,300 14,700
kg 46 58 58 96 108
Net Weight kW 2.8 3.3 4.2 4.9
(Ibs.) (101) (128) (128) (211) (238)
Nominal Heating Capacity kcal/h 2,400 2,800 3,600 4,200
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Btu/h 9,600 11,100 14,300 16,700
Indoor Fan Sound Pressure Level
m3/min. 27/23/19 37/31/25 38/35/29 58 72 dB(A) 28-25-22 28-25-22 32-30-28 32-30-28
Air Flow Rate (High/Medium/Low)
(cfm) (954/812/671) (1,306/1,095/883) (1,341/1,236/1,024) (2048) (2542)
(Hi/Me/Lo) H mm 192 192 192 192
External Pressure (Option) Outer Dimensions W mm 700 700 700 700
pa 120(90) 120(90) 120(90) 180 180
*3)
D mm 902 602 602 602
Motor W 120 200 280 650 900 kg 21 21 21 21
Net Weight
(lbs) 46 46 48 48
Connections
Flare-Nut Connection (with Flare Nuts) Refrigerant R410A (Nitrogen-charged for Corrosion-resistance)
Refrigerant Piping
mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Indoor Fan Air Flow Rate
Liquid Line m /min
3
8/7/6 8/7/6 10/8/7 10/8/7
(High /Medium /Low)
(in.) (3/8) (3/8) (3/8) (3/8) (3/8)
Motor Power w 50 50 60 60
mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
Gas Line Connections Refrigerant Piping Flare-nut Connection (with Flare Nuts)
(in.) (5/8) (5/8) (5/8) (3/4) (7/8)
mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
Condensate Drain VP25 VP25 VP25 VP25 VP25 Liquid Line
(in.) (1/4) (1/4) (1/4) (1/4)
Approximate mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
m 3
0.38 0.52 0.52 0.9 1.06
Packing Measurement Gas Line
(in.) (1/2) (1/2) (1/2) (1/2)
NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS standard B8616. Condensate Drain VP25
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB)
External Static Pressure Pa 10(30) 10(30) 10(30) 10(30)
*1) 19.5°C WB (67°F WB) Approximate Packing
*2) 19.0°C WB (66.2°F WB) m3 0.15 0.15 0.15 0.15
Outdoor Air Inlet Temperature: 35°C DB (95°F DB)
Measurement
Heating Operation Conditions
Indoor Air Inlet Temperature: 20°C DB (68°F DB) NOTES: 2. The sound pressure level is based on following conditions.
Outdoor Air Inlet Temperature: 7°C DB (45°F DB) 1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS 1.5 Meter Beneath the Unit.
6°C WB (43°F WB) standard B8616. With Discharge Duct (2.0m) and Return Duct (1.0m).
Piping Length: 7.5 Meters Piping Lift: 0 Meter Cooling Operation Conditions Voltage of the power source for the indoor fan motor is 220V.
2. The sound pressure level is based on following conditions. Indoor Air Inlet Temperature: 27°C DB (80°F DB) In case of the power source of 240V, the sound pressure level increases by about 1 dB.
1.5 Meter Beneath the Unit. *1) 19.5°C WB (67°F WB) The above data was measured in an anechoic chamber so that reflected should be taken
With Discharge Duct (2.0m) and Return Duct (1.0m). *2) 19.0°C WB (66.2°F WB) into consideration in the field.
Voltage of the power source for the indoor fan motor is 220V. Outdoor Air Inlet Temperature: 35°C DB (95°F DB) 3. The data for external pressure *3) indicates” Standard Pressure Setting values when a
In case of the power source of 240V, the sound pressure level increases by about 1 dB. Heating Operation Conditions filter is not used.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field. Indoor Air Inlet Temperature: 20°C DB (68°F DB)
3. The data for external pressure *3) indicates” Standard Pressure Setting values when a filter is not used. Outdoor Air Inlet Temperature: 7°C DB (45°F DB)
6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
28 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 29
YORK® VRF INDOOR UNITS
Indoor Fan Air Flow Rate m3/min. Approximate Packing Measurement m3 0.18 0.18 0.18 0.18
8/7/6 8/7/6 10/8/7 10/8/7
(Hi/Me/Lo) (cfm) (283/247/212) (283/247/212) (353/283/247) (353/283/247)
NOTES:
External Pressure (Option) *3) pa 10(30) 10(30) 10(30) 10(30) 1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Motor W 16 16 25 25 Indoor Air Inlet Temperature: 27°C DB (80°F DB)
*1) 19.5°C WB (67°F WB)
Connections *2) 19.0°C WB (66.2°F WB)
Flare-Nut Connection (with Flare Nuts) Outdoor Air Inlet Temperature: 35°C DB (95°F DB)
Refrigerant Piping
Heating Operation Conditions
mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Liquid Line Outdoor Air Inlet Temperature: 7°C DB (45°F DB)
(in.) (1/4) (1/4) (1/4) (1/4) 6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 2. The sound pressure level is based on following conditions.
Ges Line
(in.) (1/2) (1/2) (1/2) (1/2) 1.5 Meter Beneath the Unit.
With Discharge Duct (2.0m) and Return Duct (1.0m).
Condensate Drain VP25 VP25 VP25 VP25 Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
Approximate Packing Measurement m 3
0.15 0.15 0.15 0.15
3. The data for external pressure *3) indicates” Standard Pressure Setting values when a filter is not used.
30 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 31
YORK® VRF INDOOR UNITS
Nominal Cooling Capacity*2) kcal/h 2,400 3,700 4,800 6,100 btu/h 9,900 14,100
Btu/h 9,500 14,700 19,100 24,200
kW 2.8 4.0
kW 3.3 4.9 6.5 8.5
Nominal Heating Capacity kcal/h 2,800 4,200 5,600 7,300 Nominal Cooling Capacity*2 kcal/h 2,400 3,400
Refrigerant R410A/R407C/R22 (Nitrogen-Charged for Corrosion-Resistance) Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
NOTES: NOTES:
1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS standard B8616. 1. The nominal cooling capacity is the combined capacity of Johnson Controls’ standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions Cooling Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB) Indoor Air Inlet Temperature: 27°C DB (80°F DB)
*1) 19.5°C WB (67°F WB) *1) 19.5°C WB (67°F WB)
*2) 19.0°C WB (66.2°F WB) *2) 19.0°C WB (66.2°F WB)
Outdoor Air Inlet Temperature: 35°C DB (95°F DB) Outdoor Air Inlet Temperature: 35°C DB (95°F DB)
Heating Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 20°C DB (68°F DB) Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Outdoor Air Inlet Temperature: 7°C DB (45°F DB) Outdoor Air Inlet Temperature: 7°C DB (45°F DB)
6°C WB (43°F WB) 6°C WB (43°F WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 2. The sound pressure level is based on following conditions.
1 meter beneath the Unit 1 meter beneath the Unit
1 meter from inlet grille. 1 meter from inlet grille.
The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field. The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the field.
32 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 33
Summary Table of Outdoor Units
Heat Pump
VRF
Capacity 10, 20, 30 HP
Maximum connectable indoor unit quantity 32
Maximum height difference between OD and ID (when OD is higher than ID) ft (m) 164 (50)
Maximum height difference between OD and ID (when ID is higher than OD) ft (m) 131 (40)
Maximum height difference between ID and ID ft (m) 49 (15)
Conditions of operation
Cooling Operation
Heating Operation
113 (45)
113 (45)
Outdoor Units
of the Indoor unit (DBT °F (°C)
(DBT/WBT °F (°C)
34 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 35
YORK® VRF OUTDOOR UNITS
YORK® VRF outdoor units provide maximum flexibility for modular design.
Type Single Unit Systems
10-30HP Systems
Tonnage 10HP 20HP 30HP
JTWH100NPER0AB 2x JTWH100NPER0AB 3x JTWH100NPER0AB
Model JTWH100NPEF0AB 2x JTWH100NPEF0AB 3x JTWH100NPEF0AB
ER-3ø220V / EF-3ø380V
Power Supply 220Vca / 60 Hz and 380Vca / 60 Hz
kW 28 56 84
Nominal Cooling Capacity kcal/h 24.074 48.149 72.223
BTU/h 95.563 191.126 286.689
kW 31,5 63,0 94,5
Nominal Heating Capacity kcal/h 27.084 54.167 81.251
BTU/h 107.509 215.017 322.526
Sound Pressure Level dBA 52 54 56
Chamber Color - Beige
JTWH100NPER0AB 2x JTWH100NPER0AB 3x JTWH100NPER0AB Heigh mm 1.200
External Dimensions Width mm 780 1.710 2.640
JTWH100NPEF0AB 2x JTWH100NPEF0AB 3x JTWH100NPEF0AB Depth mm 555
10HP 20HP 30HP Net Weight kg 155 310 465
Weight when in Operation kg 157 314 471
ER - 3ø220V Refrigerant - R-410A
Refrigerant
Flow Control - Expansion Valve Controlled by a Microcomputer
EF - 3ø380V Scroll Inverter Compressor Quantity - 1 2 3
Heat Exchanger Type - PHE - Brazed Plate Exchanger
Maximum Pressure of Water in the Brazed Plate Exchanger MPa 1,96
Inlet -
1” 1/4 ISO 228/1 - G (OUTER NUT)
Benefits: Water Connections Outlet -
Drain Outlet - 1/2” BSPT (INTERNAL SCREW) - Only Frontal
Refrigerant Piping of up to Liquid Line (mm) ø 9,53 - Short-Nut Connection
· Smaller amount of copper tube 120m Gas Line (mm) ø 22,22 - Flange (Supplied by the Manufacturer)
Water Flow m³ / h 5,76 5,76 x 2 5,76 x 3
· Smaller amount of refrigerant charge Refrigerant Load (INCLUDED) kg 3,2 3,2 + 3,2 3,2 + 3,2 + 3,2
Closed Bores for Electrical Electrical Network mm ø 42
cooling · Smaller loss of the effective capacity Interconnection Control Circuits mm ø 42
tower Combination of Capacities (HP)
Min 50% of Nominal Capacity
· Installation at coastal area Combination of Condenser and
Max 130% of Nominal Capacity
Minimum Capacity for Individual Operation (HP) Min 0,8
Indoor Units
· High building project Combination for Indoor Units
Min 2
2 Max 16 20 32
Remarks:
1. The cooling and heating capacities described above are the combined capacities of the Standard Split System by YORK and are based on standard JIS B8616.
Piping Length: 7.5 m and piping drop: 0 m
1 Maximum Gap
1 External Unit above Internal: 50m Cools Heats
Incoming Water Temperature 30° C 20° C
External Unit below Internal: 40m BS 27° C 20° C
5 Incoming Indoor Air Temperature
BU 19° C -
Piping maximum length from the first multi-kit until BS: Dry Bulb / BU: Wet Bulb
Water 2
piping the farther evaporator: 40m 2. The sound pressure level is based on the following conditions:
At 1 m from the surface of the servicce seal of the unit and at 1.5 m from ground level.
The information above was measured inside a wind chamber, and, on-site, the sound reflected must be taken into consideration.
Piping maximum length from multi-kit to each
3 3 In the event of nighttime operations, the noise level decreases 2 dBA.
evaporator: 30m 3. This equipment must be installed in a machine room or indoor environments protected against rains and other bad weather, with an environment temperature of 10° C to 40° C, and ventilated for the elimination of the
4 heat dissipated by the equipment.
It may not be installed in outdoor environments.
Piping maximum length from condenser until the
4 4. The condensation tower system must be selected as per the recommendations described in the User Manual.
farther evaporator:
5. The equipment is supplied with filter “Y” MESH 40 and with a flange for the gas line.
36 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 37
YORK® VRF OPTIONAL PARTS & ACCESSORIES
First Multi-kit
Outdoor Unit HP 10HP 20HP 30HP
< 80m JE-102SN JE-242SN JE-302SN
Liquid (Ømm) Ø9.53 Ø9.53 Ø9.53 Ø12.7 Ø12.7 Ø15.88 Ø19.05 Ø19.05
38 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 39
Control Systems
• The new large LCD display
permits users to see the operating
conditions and settings.
JCWB10NEWS
• The timer can be set at half-hour
JCRA10NEWQ
intervals up to 72 hours.
• All the functions can be selected by
remote control switches.
Remote Control Switch
Compatible with the H-LINKⅡ • The JCWA10NEWQ monitors the Wireless
operating conditions in the system Remote Control Switch
• The newly-adopted LED-backlit LCD and an alarm is issued if a problem Compatible with the H-LINKⅡ
provides enhanced legibility. Large,
occurs.
clear character display is realized by • One-touch handy operation, no wiring
Full Dot Matrix LCD. • A “self-diagnosis function” work required.
checks for problems on printed
• The newly-adopted directional key boards in indoor and outdoor • Two or more units can be operated
provides optimized operation. The simultaneously by remote control.
units.
manual operation is facilitated by
• Equipped with energy-saving * Receiver kit is required.
reducing number of switch buttons
from 13 to 9. functions such as a preset
temperature range limiting
• “Schedule Timer” provides the function for preventing excessive
timer operations for “Run/Stop” and
cooling/heating and a preset
“Temperature Setting”. The weekly
temperature automatic reset
management is available by using this JCOA111EWS
function, as well as an operation
function. In addition “Holiday Setting”
locking mechanism and the
and “Schedule ON/OFF”setting are
capability to prevent users from
available.
forgetting to turn off the system.
• 4 type of menus are offered for flexible (Function selection setting is Centralized
use as follows:
required) ON/OFF Controller
Menu: Contains “Schedule”, “Elevating Compatible with the H-LINKⅡ
Grill”, etc. for users. Up to 160 indoor units
Help Menu: Contains information Up to 16 remote control groups
provided by this remote control switch
for users such as “About Indication”, • Only performs operation/stop
“Contact Information”, etc. JCSA10NEWS control per remote control group.
Test Run Menu: This menu • By connecting to the H-LINK, up to
Controls
provides the functions 16 remote control groups and 160
installation of this remote control
Half-size indoor units can be controlled. Up
switch.
Remote Control Switch to 8 units can be connected to the
Check Menu: This menu provides the Compatible with the H-LINKⅡ H-LINK
functions for service and maintain
• The main function of this easy- • An external input terminal is
YORK® VRF systems offer a wide range Wired Controller to-use remote control system is
temperature setting. provided as standard. External
of control systems to suit multiple applications. Wireless Controller signals enable the following
• Operation modes can be switched
Systems include wired and wireless controls, central station over(when function selection setting functions: central operation/stop,
Central Station is made). emergency stop, central operation
and computerized control options, and BACnet Adapter for Computerized Controller JCWA10NEWQ • Suitable for facilities used by various output, central alarm output
people, such as hotels.
control by way of building management systems. • Can be used in combination with
BACnet Adapter • “2 remote control” or “group the Central Station.
control” (up to 16 max.) can be
Remote Control Switch
used. * Make sure to use it with a remote control switch.
Compatible with the H-LINKⅡ Indoor units cannot be used without a remote
• If a problem occurs, an alarm code control switch.
• The JCWA10NEWQ has a design that immediately shows the details of * There are restrictions on remote group registration.
matches the interior. the problem. Please contact our sales staff for more information.
40 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 41
YORK® VRF CONTROLLERS
42 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 43
Notes
44 JOHNSON CONTROLS | YORK® VRF SYSTEMS JOHNSON CONTROLS | YORK® VRF SYSTEMS 45
Authorized Dealer