Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

Rosemount 3051S Series Pressure Transmitter


with FOUNDATION™ Fieldbus

Rosemount 3051SF Series Flowmeter Electronics


with FOUNDATION™ Fieldbus
Start

Step 1: Mount the Transmitter


Step 2: Tagging
Step 3: Consider Housing Rotation
Step 4: Connect Wiring and Power Up
Step 5: Verify Configuration
Step 6: Trim the Transmitter
Product Certifications

End

¢00825-0100-4805-¤

www.rosemount.com
4805_RevDA.fm Page 2 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

© 2009 Rosemount Inc. All rights reserved. All marks property of owner.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.

Rosemount Inc. Emerson Process Management GmbH & Co. OHG


8200 Market Boulevard Argelsrieder Feld 3
Chanhassen, MN USA 55317 82234 Wessling
T (US) (800) 999-9307 Germany
T (Intnl) (952) 906-8888 T 49 (8153) 9390
F (952) 949-7001 F49 (8153) 939172
Emerson Process Management Beijing Rosemount Far East
Asia Pacific Private Limited Instrument Co., Limited
1 Pandan Crescent No. 6 North Street,
Singapore 128461 Hepingli, Dong Cheng District
T (65) 6777 8211 Beijing 100013, China
F (65) 6777 0947/65 6777 0743 T (86) (10) 6428 2233
F (86) (10) 6422 8586
m

IMPORTANT NOTICE
This installation guide provides basic guidelines for Rosemount 3051S transmitters (see the 3051S
reference manual (document number 00809-0100-4801 and 00809-0200-4801). It also provides the basic
electronics guidelines for the 3095SFA (reference manual document number 00809-0100-4809) and
3095SFC (reference manual document number 00809-0100-4810). It does not provide instructions for
diagnostics, maintenance, service, or troubleshooting. This manual is also available electronically on
www.rosemount.com.

WARNING
Explosions can result in death or serious injury.
• Do not remove the transmitter covers in explosive environments when the circuit is live.
• Both transmitter covers must be fully engaged to meet
explosion-proof requirements.
• Make sure the instrument is installed in accordance with intrinsically safe or nonincendive field wiring
practices.
Process leaks may cause harm or result in death.
• To avoid process leaks, only use the o-ring designed to seal with the corresponding flange adapter.
Electrical shock can result in death or serious injury.
• Avoid contact with the leads and the terminals. High voltage that may be present on leads can cause
electrical shock.

2
4805_RevDA.fm Page 3 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

STEP 1: MOUNT THE TRANSMITTER


Liquid Flow Applications
1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Mount the transmitter so that the drain/vent
valves are oriented upward.

Gas Flow Applications


1. Place taps in the top or side of the line.
2. Mount beside or above the taps.

Steam Flow Applications


1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Fill impulse lines with water.

3
4805_RevDA.fm Page 4 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

STEP 1 CONTINUED...
Panel Mount Pipe Mount
Coplanar™ Flange

Traditional Flange

In-line

4
4805_RevDA.fm Page 5 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

STEP 1 CONTINUED...
Bolting Considerations
If the transmitter installation requires assembly of the process flanges, manifolds, or flange
adapters, follow these assembly guidelines to ensure a tight seal for optimal performance
characteristics of the transmitters. Use only bolts supplied with the transmitter or sold by
Emerson as spare parts. Figure 1 illustrates common transmitter assemblies with the bolt length
required for proper transmitter assembly.

Figure 1. Common Transmitter Assemblies

A. Transmitter with C. Transmitter with Traditional D. Transmitter with


Coplanar Flange Flange and Optional Flange Coplanar Flange and
Adapters Optional Manifold and
Flange Adapters

4 x 2.25-in. (57 mm)

4 x 1.75-in. (44 mm)

B. Transmitter with Coplanar


Flange and Optional
Flange Adapters

4 x 1.75-in. (44 mm)


4 x 1.50-in. (38 mm)

4 x 1.75-in. (44 mm)


4 x 2.88-in. (73 mm)

Bolts are typically carbon steel or stainless steel. Confirm the material by viewing the markings
on the head of the bolt and referencing Figure 2. If bolt material is not shown in Figure 2, contact
the local Emerson Process Management representative for more information.
Use the following bolt installation procedure:
1. Carbon steel bolts do not require lubrication and the stainless steel bolts are coated with a
lubricant to ease installation. However, no additional lubricant should be applied when
installing either type of bolt.
2. Finger-tighten the bolts.
3. Torque the bolts to the initial torque value using a crossing pattern. See Figure 2 for initial
torque value.
4. Torque the bolts to the final torque value using the same crossing pattern. See Figure 2 for
final torque value.
5. Verify that the flange bolts are protruding through the isolator plate before applying pressure.

5
4805_RevDA.fm Page 6 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

STEP 1 CONTINUED...
Figure 2. Torque values for the flange and flange adapter bolts
Bolt Material Head Markings Initial Torque Final Torque

Carbon Steel (CS) 300 in.-lbs. 650 in.-lbs.


B7M

Stainless Steel (SST) 150 in.-lbs. 300 in.-lbs.


316 B8M
316

316 STM SW
R 316 316

O-rings with Flange Adapters

WARNING
Failure to install proper flange adapter O-rings may cause process leaks, which can result in death or
serious injury. The two flange adapters are distinguished by unique O-ring grooves. Only use the O-ring
that is designed for its specific flange adapter, as shown below.

Rosemount 3051S / 3051 / 2051 / 3001 / 3095 / 2024


Flange Adapter

O-ring

PTFE Based
Elastomer
Rosemount 1151

Flange Adapter
O-ring

PTFE
Elastomer

Whenever the flanges or adapters are removed, visually inspect the o-rings. Replace them if
there are any signs of damage, such as nicks or cuts. If you replace the o-rings, re-torque the
flange bolts and alignment screws after installation to compensate for seating of the PTFE
o-ring.

6
4805_RevDA.fm Page 7 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

STEP 2: TAGGING
Commissioning (Paper) Tag
To identify which device is at a particular location
use the removable tag provided with the COMMISSIONING TAG
transmitter. Ensure that the physical device tag Device ID:
0011513051010001440-121698091725
(PD Tag field) is properly entered in both places
on the commissioning tag. Tear off the bottom PD Tag:
PT- 101
portion of the tag and write “physical tag” on this
Revision: 23
portion. This can now be given to the person who Support files available at
can associate the device ID to the desired tag. www.rosemount.com
Tear Here
NOTE Revision: 23
The device description loaded in the host system Support files available at
www.rosemount.com
must be at the same revision as this device. The
device description can be downloaded from Device Serial Number:
XXXXXXXXXX
www.rosemount.com or www.fieldbus.org.
Device ID:
0011513051010001440-121698091725
PD Tag:
PT- 101

STEP 3: CONSIDER HOUSING ROTATION


To improve field access to wiring or to better PlantWeb Junction Box
view the optional LCD display:
1. Loosen the housing rotation set screw.
2. First, rotate the housing clockwise to the
desired location. If the desired location
cannot be achieved due to thread limit,
rotate the housing counter clockwise to the
desired location (up to 360° from thread
limit). Housing Rotation Set
Screw (3/32-inch)
3. Retighten the housing rotation set screw.
NOTE
Rotating the housing more than 360° may damage the transmitter.

7
4805_RevDA.fm Page 8 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

STEP 4: CONNECT WIRING AND POWER UP


Cable Connection
The segment cable can enter the transmitter through either conduit connection on the housing.
Cable entering the housing vertically should be avoided. Drip loops are recommended for
installations where moisture can accumulate and enter the Terminal Compartment.
Power Supply
The transmitter requires between 9 and 32 Vdc (9 and 15 Vdc for FISCO) at the terminals to
operate and provide complete functionality.
Power Conditioner
A fieldbus segment requires a power conditioner to isolate the power supply filter and decouple
the segment from other segments attached to the same power supply.
Signal Termination
Every fieldbus segment requires terminators at each end of the segment. Failure to properly
terminate segments may cause communication errors with devices on the segment.
Transient Protection
Transient protection devices require the transmitter be grounded for proper operation. Refer to
“Grounding” for further information.
Grounding
Grounding terminations are provided on the sensor module and inside the Terminal
Compartment. These grounds are used when transient protect terminal blocks are installed or to
fulfill local regulations. See Note 2 on page 8 for more information on how the cable shield
should be grounded.
1. Remove the FIELD TERMINALS housing cover.
2. Connect the wiring pair and ground as indicated in Figure 3.
a. The terminals are not polarity sensitive.
b. The cable shield should:
• Be trimmed close and insulated from touching the transmitter housing.
• Continuously connect to the termination point.
• Be connected to a good earth ground at the power supply end.

Figure 3. Wiring
Minimize Distance Ground for
Trim shield Transient
and insulate Protection

DP

Insulate Shield
Minimize Distance
FIELDBUS WIRING

Connect Shield Back to the


Power Supply Ground

8
4805_RevDA.fm Page 9 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series
3. Replace the housing cover. It is recommended that the cover be tightened until there is no
gap between the cover and the housing.
4. Plug and seal unused conduit connections.

IMPORTANT NOTICE
The enclosed pipe plug must be installed in unused conduit opening with a minimum of five thread
engagement to comply with explosion-proof requirements. Refer to the 3051S FOUNDATION fieldbus reference
manual (document number 00809-0200-4801) for more information. This manual is also available
electronically on www.emersonprocess.com/rosemount.

STEP 5: VERIFY CONFIGURATION


Use the following block examples to do basic configuration to the transmitter. For more
advanced configurations see the 3051S Series FOUNDATION Fieldbus Manual
(00809-0200-4801).
NOTE
DeltaV users should use DeltaV Explorer for the Resource and Transducer blocks and Control
Studio for the Function Blocks.
To configure the AI Block
AI Block configuration parameters
Use the Pressure, DP Flow, and DP Level examples for guides.
Parameters Enter Data
Channel 1 = Pressure or 2 = Sensor Temp or 3 = Mass Flow
L_Type Direct, Indirect, or Square Root
XD_Scale Scale and Engineering Units
Note: Only select the units that are supported by the device.
Pa bar inH20 @ 68°F psi inHg @ 0°C
kPa mbar mmH20 @ 68°F g/cm2 mmHg @ 0°C
mPa atm ftH20 @ 68°F kg/cm2 mmH20 @ 4°C
torr inH20 @ 4°C
Out_Scale Scale and Engineering Units

Pressure example
Parameters Enter Data
Channel 1
L_Type Direct
XD_Scale See list of supported engineering units.
Note: Only select the units that are supported by the device.
Out_Scale Set values outside operating range.

DP Flow example
Parameters Enter Data
Channel 1
L_Type Square Root
XD_Scale 0 - 100 inH20 @ 68°F
Note: Only select the units that are supported by the device.
Out_Scale 0 - 20 GPM

9
4805_RevDA.fm Page 10 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

DP Level example
Parameters Enter Data
Channel 1
L_Type Indirect
XD_Scale 0 - 300 inH20 @ 68°F
Note: Only select the units that are supported by the device.
Out_Scale 0-25 ft.

To display pressure on the LCD meter:


Parameter Enter Data
Display Parameter 1
Block Type #1 Sensor Transducer Block
Block Tag TRANSDUCER
Param Index Primary Variable
Units Type Auto

NOTE
To display level or flow, use AI block Out.

STEP 6: TRIM THE TRANSMITTER


NOTE
Transmitters are shipped fully calibrated per request or by the factory default of full scale (span
= upper range limit).
Zero Trim
A zero trim is a single-point adjustment used for compensating mounting position and line
pressure effects. When performing a zero trim, ensure that the equalizing valve is open and all
wet legs are filled to the correct level.
The transmitter will only allow 3-5% URL Zero error to be trimmed. For greater zero errors,
compensate for the offset by using the XD_Scaling, Out_Scaling and Indirect L_Type which are
part of the AI Block.
Using the host system
Perform a Zero Trim method if the host system supports methods associated with the
TRANSDUCER 1400 block. Otherwise, if the host system does not support methods see 3051S
FOUNDATION Fieldbus Manual 00809-0200-4801.

10
4805_RevDA.fm Page 11 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

PRODUCT CERTIFICATIONS
Approved Manufacturing Locations
Rosemount Inc. — Chanhassen, Minnesota USA
Emerson Process Management GmbH & Co. — Wessling, Germany
Emerson Process Management Asia Pacific
Private Limited — Singapore
Beijing Rosemount Far East Instrument Co., Limited – Beijing, China
Emerson Process Management LTDA — Sorocaba, Brazil
Emerson Process Management (India) Pvt. Ltd. — Daman, India
European Directive Information
The EC declaration of conformity for all applicable European directives for this product can be
found at www.rosemount.com. A hard copy may be obtained by contacting our local sales office.
ATEX Directive (94/9/EC)
Emerson Process Management complies with the ATEX Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option) Pressure Transmitters — QS
Certificate of Assessment -
EC No. PED-H-20, Module H Conformity Assessment
All other Model 3051S Pressure Transmitters
— Sound Engineering Practice
Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold — Sound Engineering
Practice
Primary Elements, Flowmeter
— See appropriate Primary Element QIG
Electro Magnetic Compatibility (EMC) (2004/108/EC)
EN 61326-1:1997 + A1, A2, and A3 - Industrial
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested to determine that the design meets
basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized
testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health
Administration (OSHA).
Hazardous Locations Certifications
North American Certifications
FM Approvals
E5 Explosion-proof for Class I, Division 1, Groups B, C, and D; dust-ignition proof for Class II
and Class III, Division 1, Groups E, F, and G; hazardous locations;
enclosure Type 4X, conduit seal not required when installed according to Rosemount
drawing 03151-1003.
I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1,
Groups E, F, and G; Class III, Division 1 when connected in accordance with Rosemount
drawing 03151-1006; Non-incendive for Class I, Division 2, Groups A, B, C, and D,
Enclosure Type 4X; For entity parameters see control drawing 03151-1006.

11
4805_RevDA.fm Page 12 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

Canadian Standards Association (CSA)


All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003.
E6 Explosion-proof for Class I, Division 1, Groups B, C, and D;
Dust Ignition-proof for Class II and Class III, Division 1,
Groups E, F, and G; suitable for Class I, Division 2,
Groups A, B, C, and D, when installed per Rosemount drawing 03151-1013, CSA
Enclosure Type 4X; conduit seal not required.
I6/IF Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in
accordance with Rosemount drawings 03151-1016; For entity parameters see control
drawing 03151-1016.
European Certifications
I1 ATEX Intrinsic Safety
Certificate No.: BAS01ATEX1303X II 1G
Ex ia IIC T4 (-60°C ≤ Ta ≤ 70°C)
1180
Table 1. Input Parameters
Loop / Power
Ui = 30V
Ii = 300 mA
Pi = 1.3W
Ci = 0 nF
Li = 0 μH

Special Conditions for Safe Use (X):


The apparatus, excluding the Types 3051 S-T and 3051 S-C (In-line and Coplanar
SuperModules respectively), is not capable of withstanding the 500V test as defined in
Clause 6.3.12 of EN 60079-11. This must be considered during installation.
The terminal pins of the Types 3051 S-T and 3051 S-C must be protected to IP20
minimum.
IA ATEX FISCO Intrinsic Safety
Certificate No.: BAS01ATEX1303 II 1 G
Ex ia IIC T4 (-60°C ≤ Ta ≤ 40°C)
1180
Table 2. Input Parameters
Loop / Power
Ui = 17.5 V
Ii = 380 mA
Pi = 5.32 W
Ci = 0 nF
Li = 0 μH

Special Conditions for Safe Use (X):


The apparatus, excluding the Types 3051 S-T and 3051 S-C (In-line and Coplanar
SuperModules respectively), is not capable of withstanding the 500V test as defined in
Clause 6.3.12 of EN 60079-11. This must be considered during installation.
The terminal pins of the Types 3051 S-T and 3051 S-C must be protected to IP20
minimum.

12
4805_RevDA.fm Page 13 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series
N1 ATEX Type n
Certificate No.: BAS01ATEX3304X II 3 G
Ex nAnL IIC T4 (Ta = -40 °C TO 70 °C)
Ui = 45 Vdc max.
IP66
1180
Special Conditions for Safe Use (X):
The apparatus is not capable of withstanding the 500V insulation test required by Clause
6.8.1 of EN 60079-15. This must be taken into account when installing the apparatus.
ND ATEX Dust
Certificate No.: BAS01ATEX1374X II 1 D
Ex tD A20 T105°C (Tamb = -20°C to 85°C)
Vmax = 42.4 V
A = 22 mA
IP66
1180
Special Conditions for safe use (X):
1. The user must ensure that the maximum rated voltage and current (42.4 volts, 22
milliamps, DC) are not exceeded. All connections to other apparatus or associated
apparatus shall have control over this voltage and current equivalent to a category “ib”
circuit according to EN 60079-11.
2. Cable entries must be used which maintain the ingress protection of the enclosure to at
least IP66.
3. Unused cable entries must be filled with suitable blanking plugs which maintain the
ingress protection of the enclosure to at least IP66.
4. Cable entries and blanking plugs must be suitable for the ambient range of the
apparatus and capable of withstanding a 7J impact test.
5. The 3051S must be securely screwed in place to maintain the ingress protection of the
enclosure. (The 3051S SuperModule must be properly assembled to the 3051S
housing to maintain ingress protection.)

E1 ATEX Flameproof
Certificate No.: KEMA00ATEX2143X II 1/2 G
Ex d IIC T6 (Tamb = -50 °C to 65 °C)
Ex d IIC T5 (Tamb = -50 °C to 80 °C)
Vmax = 32 V
1180
Special Conditions for Safe Use (X):
1. Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a
temperature of 90 °C.
2. This device contains a thin wall diaphragm. Installation, maintenance and use shall take
into account the environmental conditions to which the diaphragm will be subjected.
The manufacturer’s instructions for maintenance shall be followed in detail to assure
safety during its expected lifetime.
3. The 3051S does not comply with the requirements of IEC 60079-1 Clause 5.2, Table 2
for all joints. Contact Emerson Process Management for information on the dimensions
of flameproof joints.

13
4805_RevDA.fm Page 14 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

Japanese Certifications
E4 TIIS Flameproof
Ex d IIC T6

Certificate Description
TC15682 Coplanar w/Junction Box Housing
TC15683 Coplanar w/PlantWeb Housing
TC15684 Coplanar w/PlantWeb Housing & LCD Display
TC15685 In-Line SST w/Junction Box Housing
TC15686 In-Line Alloy C-276 w/Junction Box Housing
TC15687 In-Line SST w/PlantWeb Housing
TC15688 In-Line Alloy C-276 w/Plantweb Housing
TC15689 In-Line SST w/Plantweb Housing and LCD Display
TC15690 In-Line Alloy C-276 w/PlantWeb Housing & LCD Display

China (NEPSI) Certifications


I3 China Intrinsic Safety
Certificate No. (manufactured in Chanhassen, MN): GYJ081078
Certificate No. (manufactured in Beijing, China): GYJ06367
Certificate No. (manufactured in Singapore): GYJ06365
Ex ia IIC T3~T4
Special conditions for safe use
1. Only the pressure transmitters, consisting of the 3051SC Series, 3051ST Series,
3051SL Series, and the 300S Series, are certified.
2. Applicable ambient temperature range: -60 °C to 70 °C.
3. For explosive gas atmospheres:

Loop / Power
Ui = 30 V
Ii = 300 mA
Pi = 1.3W
Ci = 0 nF
Li = 0 μH
4. During installation, protective measures should be taken to ensure ingress protection is
IP20 (GB4208) minimum.
5. The cable between the pressure transmitter and associated apparatus should be
2-wire, insulated, shielded cable. The cable core section area should be greater than
0.5 mm2. The cable shield must be grounded in a non-hazardous area and isolated
from the housing. The wiring should not be affected by electromagnetic disturbance.
6. The associated apparatus should be installed in a safe location. During installation,
operation, and maintenance, the requirements per the instruction manual should be
strictly observed.
7. End users are not permitted to change internal components.

14
4805_RevDA.fm Page 15 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series
8. During installation, use, and maintenance of the pressure transmitter, observe the
following standards:
a. GB3836.13-1997 “Electrical apparatus for explosive gas atmospheres Part 13:
Repair and overhaul for apparatus used in explosive gas atmospheres”
b. GB3836.15-2000 “Electrical apparatus for explosive gas atmospheres Part 15:
Electrical installations in hazardous area (other than mines)”
c. GB3836.16-2006 “Electrical apparatus for explosive gas atmospheres Part 16:
Inspection and maintenance of electrical installation (other than mines)”
d. GB50257-1996 “Code for construction and acceptance of electric device for
explosion atmospheres and fire hazard electrical equipment installation
engineering”

E3 China Flameproof
Certificate No. (manufactured in Beijing, China): GYJ06366
Certificate No. (manufactured in Singapore): GYJ06364
Ex d IIB+H2 T3~T5
Special conditions for safe use
1. Only the pressure transmitters, consisting of the 3051SC Series, 3051ST Series,
3051SL Series, and the 300S Series, are certified.
2. Applicable ambient temperature range: -20 to 60 °C.
3. The temperature class depends on the temperature of process medium:
Temperature Class Temperature of Process Medium
T5 ≤ 95 °C
T4 ≤ 130 °C
T3 ≤ 190 °C

4. The earth connection in the enclosure should be connected reliably.


5. During installation, use, and maintenance of the pressure transmitter, observe the
warning, “Don’t open the cover when the circuit is alive.”
6. There should be no corrosive gases present that could damage the flameproof housing.
7. A cable entry, certified by NEPSI with type of protection Ex d IIC in accordance with
GB3836.1-2000 and GB3836.2-2000, should be used when installing in a hazardous
location. Five full threads should be engaged when the cable entry is assembled to the
pressure transmitter.
8. The diameter of the cable should meet the requirements of the cable entry instruction
manual. The compression nut should be tightened. Aged seal rings should be replaced.
9. Maintenance should not be performed if the location is hazardous.
10. End users are not permitted to change internal components.
11. During installation, use, and maintenance of the pressure transmitter, observe the
following standards:
a. GB3836.13-1997 “Electrical apparatus for explosive gas atmospheres Part 13:
Repair and overhaul for apparatus used in explosive gas atmospheres”
b. GB3836.15-2000 “Electrical apparatus for explosive gas atmospheres Part 15:
Electrical installations in hazardous area (other than mines)”
c. GB50257-1996 “Code for construction and acceptance of electric device for
explosion atmospheres and fire hazard electrical equipment installation
engineering”

15
4805_RevDA.fm Page 16 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

INMETRO Certifications
I2 INMETRO Intrinsic Safety
Certificate No. (manufactured in Chanhassen, MN): CEPEL-Ex-0722/05X
Certificate No. (manufactured in Brazil): CEPEL-Ex-1414/07X
BR-Ex ia IIC T4 IP66W
E2 INMETRO Flameproof
Certificate No. (manufactured in Chanhassen, MN): CEPEL-Ex-140/2003X
Certificate No. (manufactured in Brazil): CEPEL-Ex-1413/07X
BR-Ex d IIC T5/T6 IP66W

IECEx Certifications
E7 IECEx Flameproof
Certificate No.: IECExKEM08.0010X
Ex d IIC T6 (-50 °C ≤ Tamb ≤ 65 °C)
Ex d IIC T5 (-50 °C ≤ Tamb ≤ 80 °C)
Vmax = 42.4V
Special conditions for safe use (x)
1. Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a
temperature of 90 °C.
2. This device contains a thin wall diaphragm. Installation, maintenance and use shall
take into account the environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for maintenance shall be followed in detail
to assure safety during its expected lifetime.
3. The 3051S does not comply with the requirements of IEC 60079-1 Clause 5.2, Table 2
for all joints. Contact Emerson Process Management for information on the dimensions
of flameproof joints.
I7 IECEx Intrinsic Safety
Certificate No.: IECExBAS04.0017X
Ex ia IIC T4 (Ta = -60 °C TO 70 °C)
Loop / Power
Ui = 30 V
Ii = 300 mA
Pi = 1.3 W
Ci = 0 nF
Li = 0 μH

Special Conditions of Safe Use (X):


1. The Models 3051S HART 4-20mA, 3051S Fieldbus, 3051S Profibus and 3051S FISCO
are not capable of withstanding the 500V test as defined in clause 6.3.12 of IEC
60079-11. This must be taken into account during installation.
2. The terminal pins of the Types 3051S-T and 3051S-C must be protected to IP20
minimum.
N7 IECEx Type n
Certificate No.: IECExBAS04.0018X
Ex nC IIC T4 (Ta = -40 °C to 70 °C)
Ui = 45 Vdc MAX
IP66
Special Conditions for Safe Use (X):
The apparatus is not capable of withstanding the 500 V insulation test required by Clause
8 of IEC 60079-15.
16
4805_RevDA.fm Page 17 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series
IG IECEx FISCO Intrinsic Safety
Certificate No.: IECExBAS04.0017X
Ex ia IIC T4 (-60°C ≤ Ta ≤ 40°C)
Loop / Power
Ui = 17.5 V
Ii = 380 mA
Pi = 5.32 W
Ci = 0 nF
Li = 0 μH

Special Conditions of Safe Use (X):


1. The Models 3051S HART 4-20mA, 3051S Fieldbus, 3051S Profibus and 3051S FISCO
are not capable of withstanding the 500V test as defined in clause 6.3.12 of IEC
60079-11. This must be taken into account during installation.
2. The terminal pins of the Types 3051S-T and 3051S-C must be protected to IP20
minimum.

Combinations of Certifications
Stainless steel certification tag is provided when optional approval is specified. Once a device
labeled with multiple approval types is installed, it should not be reinstalled using any other
approval types. Permanently mark the approval label to distinguish it from unused approval
types.
K1 Combination of E1, I1, N1, and ND
K2 Combination of E2 and I2
K5 Combination of E5 and I5
K6 Combination of E6 and I6
K7 Combination of E7, I7, and N7
KA Combination of E1, I1, E6, and I6
KB Combination of E5, I5, I6, and E6
KC Combination of E5, E1, I5, and I1
KD Combination of E5, I5, E6, I6, E1, and I1

17
4805_RevDA.fm Page 18 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

EC Declaration of Conformity
No: RMD 1044 Rev. G

We,
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN 55317-9685
USA

declare under our sole responsibility that the product,

Model 3051S Pressure Transmitters and Model 300S Housings


manufactured by,
Rosemount Inc.
12001 Technology Drive and 8200 Market Boulevard
Eden Prairie, MN 55344-3695 Chanhassen, MN 55317-9687
USA USA

to which this declaration relates, is in conformity with the provisions of the European
Community Directives, including the latest amendments, as shown in the attached schedule.

Assumption of conformity is based on the application of the harmonized standards and, when
applicable or required, a European Community notified body certification, as shown in the
attached schedule.

January 22, 2009 Larrell De Jong


(date of issue) (name - printed)

Manager, Global Quality


(function name - printed)

DOC

18
4805_RevDA.fm Page 19 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

Schedule
EC Declaration of Conformity RMD 1044 Rev. G

EMC Directive (2004/108/EC)

All Models WITHOUT ”Operating Frequency and Protocol Code 3”


EN 61326-1:1997 with amendments A1, A2, and A3

All Models with ”Output Code X” and ”Operating Frequency and Protocol Code 3”
EN 61326-1:2006
EN 61326-2-3: 2006

R&TTE Directive (1999/5/EC)

All Models with ”Output Code X” and ”Operating Frequency and Protocol Code 1”
EN 301 489-1: V 1.2.1 2002, EN 301 489-17: V1.4.1 2002
EN 60950-1: 2001
EN 300 328 V 1.6.1 (2004-11)

Country Restriction
Bulgaria General authorization required for outdoor use and public service
France Outdoor use limited to 10mW e.i.r.p.
Italy If used outside of own primises, general authorization is required
Norway May be restricted in the geographical area within a radius of 20km from the center of Ny-Alesund
Romania Use on a secondary basis. Individual license required.

All Models with ”Output Code X” and ”Operating Frequency and Protocol Code 3”
EN 301 489-1: V 1.2.1 2002, EN 301 489-17: V1.4.1 2002
EN 61010-1: 2001 Second Edition
EN 300 328 V 1.6.1 (2004-11)

All Models with ”Output Code X” and ”Operating Frequency and Protocol Code 3”
With the Extended Range Antenna option code “WM”
Country Restriction
Bulgaria General authorization required for outdoor use and public service
France Outdoor use limited to 10mW e.i.r.p.
Italy If used ourside of own primises, general authorization is required
Norway May be restricted in the geographical area within a radius of 20km from the center of Ny-Alesund
Romainia Use on a secondary basis. Individual license required.

File ID: 3051S CE Marking Page 2 of 4 K:\CE_Declarations\3051S\3051S_RMD1044G.doc

19
4805_RevDA.fm Page 20 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

Schedule
EC Declaration of Conformity RMD 1044 Rev. G
PED Directive (97/23/EC)
Model 3051S_CA4; 3051S_CD2, 3, 4, 5 (also with P9 option) Pressure Transmitters
QS Certificate of Assessment - EC No. PED-H-100
Module H Conformity Assessment

All other model 3051S Pressure Transmitters


Sound Engineering Practice

Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold


Sound Engineering Practice

ATEX Directive (94/9/EC)


Model 3051S Pressure Transmitter

BAS01ATEX1303X – Intrinsically Safe Certificate

Model 3051S Pressure Transmitter without Output Code ’X’


Equipment Group II, Category 1 G (Ex ia IIC T4)
EN60079-0: 2006; EN60079-11: 2007

Model 3051S Pressure Transmitter with Output Code ’X’


Equipment Group II, Category 1 G (Ex ia IIC T4)
EN60079-0: 2006; EN60079-11: 2007

BAS01ATEX3304X – Type n Certificate


Equipment Group II, Category 3 G (Ex nL IIC T5)
EN60079-0: 2006; EN60079-15: 2005

BAS01ATEX1374X – Dust Certificate


Equipment Group II, Category 1 D (T105°C)
Standards used EN61241-0:2006, EN61241-1:2004 and EN50281-1-1: 1998

Baseefa04ATEX0181X – Mining Certificate


Equipment Group I, Category M 1 (Ex ia I)
EN60079-0: 2006; EN60079-11: 2007, EN50303: 2000

Baseefa05ATEX0193U – Mining Certificate: Component


Equipment Group I, Category M 1 (Ex ia I)
EN60079-0: 2006; EN60079-11: 2007, EN50303: 2000

File ID: 3051S CE Marking Page 3 of 4 K:\CE_Declarations\3051S\3051S_RMD1044G.doc

20
4805_RevDA.fm Page 21 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
March 2009 Rosemount 3051S Series

Schedule
EC Declaration of Conformity RMD 1044 Rev. G
Model 3051S Pressure Transmitters

KEMA00ATEX2143X – Flameproof Certificate


Equipment Group II, Category 1/2 G (Ex d IIC T5/T6)
EN60079-0: 2006; EN60079-1: 2007; EN60079-26:2007

PED Notified Body


Det Norske Veritas (DNV) [Notified Body Number: 0575]
Veritasveien 1, N-1322
Hovik, Norway

ATEX Notified Bodies for EC Type Examination Certificate


KEMA [Notified Body Number: 0344]
Utrechtseweg 310, 6812 AR Arnhem
P.O. Box 5185, 6802 ED Arnhem
The Netherlands
Postbank 6794687

Baseefa [Notified Body Number: 1180]


Rockhead Business Park, Staden Lane
Buxton, Derbyshire SK17 9RZ
United Kingdom

ATEX Notified Body for Quality Assurance


Baseefa [Notified Body Number: 1180]
Rockhead Business Park, Staden Lane
Buxton, Derbyshire SK17 9RZ
United Kingdom

File ID: 3051S CE Marking Page 4 of 4 K:\CE_Declarations\3051S\3051S_RMD1044G.doc

21
4805_RevDA.fm Page 22 Friday, March 20, 2009 8:34 AM

Quick Installation Guide


00825-0100-4805, Rev DA
Rosemount 3051S Series March 2009

NOTES

22