CITYGATE ASSEMBLIES - SECTION & PLAN VIEWS

WALL ASSEMBLIES

CONCRETE/MASONRY WALLS STEEL WALLS WOOD WALLS

8" (203.2mm) 5/8" (16mm) TYPE ''X'' GYP.


WALLBOARD 2 ROWS 2X4 (38x89mm)
CONCRETE STUDS, EACH SET
MASONRY UNITS 6" (152.4mm) STEEL
STUDS @ 24" (600mm) STAGGERED 16" (400mm) ON
o.c. IN RUNNERS COMMON 2X6 (38x140mm)
PLATE
BATT. INSULATION 2 1/2" R8 GLASS FIBRE BATT.
A1 C6 C2 ACOUSTICAL INSUL. BOTH
RESILIENT METAL
SIDES
CHANNELS ON ONE
2 LAYERS 1/2" (12.7mm)
SIDE, SPACED 24"
TYPE ''X'' GYP. WALLBOARD
(600mm) o.c.
ON EACH SIDE

METAL RUNNER

2X6 (38x152mm) BASEPLATE

EXT. BRICKWORK W/ GALV. 2 ROWS 2X4 (38x89mm)


BRICK TIES BUILT INTO JOISTS STUDS, EACH SET @ 16"
AND FIXED TO STUDS AS SPEC. (400mm) o.c. ON SEPARATE
BY STRUCT. ENGNR. 2X4 (38x89mm) PLATES SET
3/4" (19mm) AIR GAP 1" (25mm) APART

6" (152.4mm) CONCRETE 1/2" (12.4mm) EXT. 89mm R12 GLASS FIBRE
MASONRY UNITS GYP. SHEATHING BATT. ACOUSTICAL INSUL.
6" (152.4mm) STEEL STUDS @ R14 GLASS FIBRE BATT. BOTH SIDES
24" (600mm) o.c. IN RUNNERS INSUL
6" (152.4mm) STEEL 5/8" (15.9mm) TYPE ''X'' GYP.
B5 R14 GLASS FIBRE BATT E4 STUDS, SPACING SPEC.
D2 WALLBOARD BOTH SIDES
INSULATION BY STRUC. ENGNR
1/2" (12.7mm) GYP. WALLBOARD VAPOUR BARRIER
1/2" (12.7mm) GYP.
WALLBOARD 2X4 (38x89mm) BASE
METAL RUNNERS
PLATES
METAL RUNNER

BRICKWORK W/ GALV. STEEL


FLOOR ASSEMBLIES ROOF ASSEMBLIES BRICK TIES BUILT INTO JOINTS
AND FIXED TO STUDS
AIR BARRIER
3/4" (19.05mm) AIRSPACE
OAK FINISH FLOORING 1 1/2" LAYER OF PEA GRAVEL
3/8" (9.5mm) PLYWOOD
2" (50.8mm) CONCRETE SHEATHING
TOPPING ROOF MEMBRANE E2
S1 R3 2x4 (38x89mm) STUDS @
4" (101.6mm) E.P.S. (TYPE 4) 7" E.P.S. (TYPE 2) RIGID INSUL. BOARD 16" (400mm) o.c.
RIGID INSULATION BOARD 5/8" (15.9mm) TYPE ''X'' GYP.
VAPOUR BARRIER WALLBOARD
6" (152.4mm) CONCRETE SLAB
6" (152.4mm) REIN. CONC. SLAB

SPRAY-ON CEILING FINISH

#: DATE: REVISION
REVISIONS
CLIENT:

BCIT CAMPUS

PROJECT:

FRR & STC RATINGS


OAK FINISH FLOORING
ROOF MEMBRANE 3700 WILLINGDON AVENUE
1 1/2" (38mm) LIGHTWEIGHT CONC.
5/8" (15.5mm) PLYWOOD DECKING
BURNABY, BC
TOPPING
2X2 (38x38mm) CROSS PURLINS ON DRAWING NAME:
U1 5/8" (15.5mm) PLYWOOD SUBFLOOR R4 2X4 (38x89mm) HORIZONTAL CROSS
2X10 (28x235mm) JOISTS @ 16"
PURLIN
2X10 (38x235mm) JOISTS @ 16"
WALL, FLOOR, AND
(400mm) o.c.
3 1/2" (89mm) R12 GLASS FIBRE BATT.
ACOUSTICAL INSUL.
(400mm) o.c.
8" (200mm) R28 GLASS FIBRE BATT.
ROOF ASSEMBLIES
RESILIENT CHANNELS @ 8" (200mm) o.c. INSUL. DATE: 28 APR 2020
2 LAYERS 5/8" (15.9mm) TYPE ''X'' GYP.
VAPOUR BARRIER SCALE: As indicated
RESILIENT CHANNELS @ 8"
WALLBOARD
(200mm) o.c.
DRAWN: Author
CHECKED: Checker
2 LAYERS 5/8" (15.9mm) TYPE ''X''
GYP. WALLBOARD E2 3D WALL ASSEMBLY RENDERING - E2 WALL ASSEMBLY DRAWING NO.:
1 2
12" = 1'-0"

A6.7.0
CITYGATE ASSEMBLIES
1/2" = 1'-0"
LOGO:

CITYGATE ASSEMBLIES - FRR CALCULATIONS


BCBC REFERENCES
• FOR PART 3: SECTION D-2 FIRE RESISTANCE
RATINGS:
- TABLES FOUND IN D-2.3.4 (METHOD OF
CALCULATION). THE COMPONENT ADDITIVE
METHOD IS USED. BURNING IN THIS
• FOR PART 9: TABLE A-9.10.31 DIRECTION
• ULC REFERENCES ARE CERTIFIED FOR CANADA
AND ARE THE CLOSEST POSSIBLE MATCH, OR AN
ALTERNATIVE IS PROVIDED.

ALL RATINGS ARE ASSUMING FIRE IS BURNING


FROM ONE SIDE.

STEEL WALLS WOOD WALLS


WALL ASSEMBLIES

CONCRETE/MASONRY WALLS C6 C2 E2
PART 9 RATING PART 3 RATING PART 9 RATING PART 3 RATING PART 9 RATING PART 3 RATING

A1 • WALLTYPE S11a: NON-LOADBEARING WALLS WALLTYPE W9b: • WOOD STUDS SPACED 16" WALLTYPE EW2b*: • WOOD STUDS SPACED 16"
- STEEL STUDS SPACED 24" - TWO ROWS 2X4 (38x89mm) (400mm) o.c.: 20 MIN. - 2x4 (38x89mm) STUDS (400mm) o.c.: 20 MIN.
PART 9 RATING PART 3 RATING (600 mm) o.c. • 5/8" (15.9mm) TYPE ''X'' GYP. STUDS SPACED 16" (400mm) • GLASS FIBRE BATT. INSUL: SPACED 16" (400mm) o.c. • GLASS FIBRE BATT. INSUL:
WALLBOARD: 40 MIN. ON COMMON 2X6 (38x140mm) 5 MIN. C2
- ABSORPTIVE MATERIAL
• STEEL STUDS: N/A
C6 PLATE • DOUBLE LAYER 1/2"
- 1/2" (12.7mm) TYPE ''X'' GYP. 5 MIN.
• WALLTYPE B1b: • TYPE S CONCRETE: WITH A1 - RESILIENT METAL WALLBOARD • 3/8" (9mm) PLYWOOD
- 190mm BARE CONCRETE AT LEAST 4.5in. (113mm), • BATT. INSUL: N/A - ABSORPTIVE MATERIAL ON (12.7mm) TYPE ''X'' GYP.
CHANNELS ON ONE SIDE
• RESILIENT METAL EACH SIDE WALLBOARD: 80 MIN.
- EXTERIOR SHEATHING SHEATHING: N/A E2
BLOCK MINIMUM 2H - 5/8" (15.9mm) TYPE ''X'' GYP. - MASONRY VENEER • 5/8" (15.9mm) TYPE ''X'' GYP.
WALLBOARD BOTH SIDES CHANNELS: N/A - 2 LAYERS 1/2" (12.7mm) TYPE CLADDING WALLBOARD: 40 MIN.
FRR: 1.5H FRR: MIN. 2H ''X'' GYP. WALLBOARD ON FRR: 105MIN. (1H 45MIN.) • VAPOUR BARRIER: N/A
FRR: N/A FRR: 40 MIN. BOTH SIDES * THIS WAS THE CLOSEST • AIR BARRIER: N/A
WALLTYPE TO E2 IN THE • BRICKWORK: N/A
ULC REFERENCES: BXUV.U935, BXUV.U937 ULC REFERENCES: BXUV.U451 FRR: 1.5H BCBC PART 9 TABLES. THE
ULC REFERENCES: BXUV.U385 GYP. WALLBOARD IS FRR: 65MIN. (1H 05MIN.)
SLIGHTLY THICKER IN E2.

FRR: 45MIN.
ULC REFERENCES: BXUV.V317
B5
PART 9 RATING PART 3 RATING E4
NON-LOADBEARING WALLS
D2
WALLTYPE B7b: PART 9 RATING PART 3 RATING PART 9 RATING PART 3 RATING
- STEEL STUDS SPACED 24" • 1/2" (12.7mm) GYP.
(600mm) o.c. WALLBOARD: 25 MINS WALLTYPE S1a: NON-LOADBEARING WALLS
• STEEL STUD FRAMING: WALLTYPE W13a: • WOOD STUDS SPACED 16"
- ABSORPTIVE MATERIAL - STEEL STUDS SPACED 24" - TWO ROWS 2X4 (38x89mm) (400mm) o.c.: 20 MIN.
- CONCRETE BLOCK N/A (600mm) o.c. • 1/2" (12.7mm) GYP.
STUDS SPACED 16" (400mm) • GLASS FIBRE BATT. INSUL:
- GYP. WALLBOARD EACH • R14 GLASS FIBRE BATT. B5 - ABSORPTIVE MATERIAL SHEATHING: 25 MIN.
ON SEPARATE 2X6 5 MIN.
SIDE INSUL: N/A - GYP. WALLBOARD EACH • R14 GLASS FIBRE BATT.
• 6" (152.4mm) TYPE S SIDE INSUL: N/A (38x140mm) PLATES • 5/8" (15.9mm) TYPE ''X'' GYP. D2
CONCRETE MASONRY • STEEL STUDS: N/A
E4 - ABSORPTIVE MATERIAL ON WALLBOARD: 40 MIN.
FRR: 2.5H EACH SIDE
UNIT: MIN. 2H FRR: 45 MIN. • VAPOUR BARRIER: N/A
• 1/2" (12.7mm) GYP. - 5/8" (15.9mm) TYPE ''X'' GYP. FRR: 65MIN. (1H 05MIN.)
TOTAL FRR: 2H 25 MIN WALLBOARD: 25 MIN. WALLBOARD ON BOTH SIDES
ULC REFERENCES: BXUV.U214
ULC REFERENCES: BXUV.V432 FRR: 50 MIN. FRR: 1H
ULC REFERENCES: BXUV.U385

FLOOR ASSEMBLIES ROOF ASSEMBLIES


BURNING IN THIS
DIRECTION S1

S1
PART 9 RATING PART 3 RATING
R3
PART 9 RATING PART 3 RATING
NOT PERMITTED IN • 6" TYPE S CONCRETE PRECAST CONCRETE UNITS
ACCORDANCE WITH BCBC SLAB: MIN. 2H NOT PERMITTED IN • REIN. TYPE S CONCRETE
TABLE A-9.10.31. • INSULATION BOARD: N/A R3
ACCORDANCE WITH BCBC SLAB: MIN. 130mm (5.12")
• CONCRETE TOPPING: N/A TABLE A-9.10.31. THICKNESS FOR A 2H
BXUV. RATING
TOTAL FRR: 2H 25 MIN J501 • 1 1/2" (38.1mm) PEA
5/8" (15.9mm) GYP. WALLBOARD GRAVEL: N/A
THIS SPECIFIC FLOORTYPE CANNOT BE FOUND ON • 7" RIGID INSUL. BOARD: N/A
ULC WEBSITE, SO THE ALTERNATIVE SUGGESTED • VAPOUR BARRIER: N/A
FLOORTYPE: BXUV.J501 (FRR: 2H) • CEILING FINISH: N/A
ROOFING MEMBRANE
TOTAL FRR: 2H
6" INSULATING CONCRETE #: DATE: REVISION
BXUV. REVISIONS
W6x16 STEEL BEAM
THIS SPECIFIC ROOFTYPE CANNOT BE FOUND ON P939 CLIENT:
ULC WEBSITE, SO THE ALTERNATIVE SUGGESTED
ROOFTYPE: BXUV.P939 (FRR: 2H)
BCIT CAMPUS

PROJECT:

U1 FRR & STC RATINGS


PART 9 RATING PART 3 RATING R4
PART 9 RATING PART 3 RATING
FLOOR TYPE F17c: • CONCRETE TOPPING: N/A R4 3700 WILLINGDON AVENUE
- 1 1/2" (38mm) CONCRETE • PLYWOOD SUBFLOOR: U1 BURNABY, BC
TOPPING N/A NOT PERMITTED IN • 2 LAYERS 5/8" (15.9mm)
- 5/8" (15.9mm) PLYWOOD • WOOD JOISTS: 10 MIN. ACCORDANCE WITH BCBC TYPE ''X'' GYP. DRAWING NAME:
SUBFLOOR • DOUBLE LAYER 5/8" TABLE A-9.10.31. WALLBOARD: 80 MIN.
- WOOD JOISTS SPACED @
16" (600mm) o.c.
(15.9mm) TYPE ''X'' GYP.
WALLBOARD: 60 MIN. ULC REFERENCES: BXUV.P531
• RESILIENT METAL
CHANNELS: N/A FIRE RESISTANCE
• WOOD JOISTS: 10 MIN.
- ABSORPTIVE MATERIAL
- 2 LAYERS 5/8" (15.9mm) TYPE
''X'' GYP. WALLBOARD
TOTAL FRR: 70 MIN. (1H
10MIN.)
• BATT INSUL: 5 MIN. RATINGS
TOTAL FRR: 95 MIN. (1H 35 DATE: 28 APR 2020
FRR: 45 MIN. MIN.)
SCALE: As indicated
ULC REFERENCES: BXUV.L569
DRAWN: JESSIE SHEN
CITYGATE ASSEMBLIES - FRR CHECKED: T.B.
1/2" = 1'-0" DRAWING NO.:

A6.7.1
LOGO:

CITYGATE ASSEMBLIES - STC CALCULATIONS

BCBC REFERENCES MANUFACTURER'S INFORMATION


• FOR CALCULATING PART 9 STC: TABLE A-9.10.31 • FOR PART 3:
- PART 9 STC REQUIREMENTS: FOR DWELLING UNITS, THE - PART 3 STC REQUIREMENTS: FOR DWELLING UNITS, THE MANUFACTURER USED: GEORGIA-PACIFIC
STC MUST BE AT LEAST 50, AND ADJOINING STC MUST BE AT LEAST 50, AND ADJOINING ASSEMBLIES CAN BE FOUND AT buildgp.com/assemblies
CONSTRUCTIONS MUST HAVE AN STC OF AT LEAST 47. FOR CONSTRUCTIONS MUST HAVE AN STC OF AT LEAST 47.
HOUSES WITH SECONDARY SUITES, THE STC MUST BE AT ASSEMBLIES SEPARATING DWELLING UNITS FROM
LEAST 43. ELEVATOR SHAFTS MUST HAVE AN STC OF AT LEAST 55.
- ASSEMBLIES SEPARATING DWELLING UNITS FROM • PART 3 USES THE SAME METHOD OF CALCULATION AS
ELEVATOR SHAFTS MUST HAVE AN STC OF AT LEAST 55. PART 9 DOES.

WALL ASSEMBLIES
STEEL WALLS WOOD WALLS

C6 C2 E4
PART 3 & 9 RATING GEORGIA-PACIFIC PART 3 & 9 RATING GEORGIA-PACIFIC
PART 3 & 9 RATING GEORGIA-PACIFIC
MANUFACTURER'S INFORMATION MANUFACTURER'S INFORMATION
WALLTYPE W9b: MANUFACTURER'S INFORMATION
• WALLTYPE S11a:
• STEEL-FRAMED WALL: - TWO ROWS 2X4 (38x89mm) WOOD-FRAMED WALL: WALLTYPE S1a:
- STEEL STUDS SPACED 24" EXTERIOR STEEL-FRAMED
- 1/2" GYP. BOARD APPLIED STUDS SPACED 16" (400mm) - DOUBLE 5/8" GYP. - STEEL STUDS SPACED 24"
(600 mm) o.c. C2 WALL:
ON COMMON 2X6 (38x140mm) (600mm) o.c.
- ABSORPTIVE MATERIAL BOTH SIDES C6 PLATE
WALLBOARD EACH SIDE
- ABSORPTIVE MATERIAL - 5/8" GYP. WALLBOARD
- RESILIENT METAL - STEEL STUDS 24" (600mm) - 2X4 (38x89mm) STUDS
- ABSORPTIVE MATERIAL ON - GYP. WALLBOARD EACH - 5/8" SHEATHING
CHANNELS ON ONE SIDE o.c. STAGGERED 8" (200mm) o.c.
EACH SIDE SIDE - STEEL STUDS @ 16" (400mm) E4
- 5/8" (15.9mm) TYPE ''X'' GYP. - ABSORPTIVE MATERIAL ON 2X6 (38x140mm) PLATE
- 2 LAYERS 1/2" (12.7mm) TYPE o.c.
WALLBOARD BOTH SIDES - EXTERIOR BRICKWORK
STC: 40-44 ''X'' GYP. WALLBOARD ON STC: 45-49 STC: 43
STC: 50 BOTH SIDES * THIS WALL DOES NOT
STC: NOT RATED
INCLUDE INSULATION, BUT
STC: 55 WAS THE CLOSEST POSSIBLE
MATCH TO THIS WALLTYPE.

FLOOR ASSEMBLIES
GEORGIA-PACIFIC
D2 MANUFACTURER'S INFORMATION
PART 3 & 9 RATING
WOOD-FRAMED WALL:
WALLTYPE W13a: - 5/8" GYP. WALLBOARD EACH
- TWO ROWS 2X4 (38x89mm) SIDE S1 U1 GEORGIA-PACIFIC
STUDS SPACED 16" (400mm) - 2X4 (38x89mm) STUDS @ 16" MANUFACTURER'S INFORMATION
PART 3 & 9 RATING GEORGIA-PACIFIC PART 3 & 9 RATING
ON SEPARATE 2X6 (400mm) o.c. ON SEPARATE
2X4 (38x89mm) PLATES MANUFACTURER'S INFORMATION FLOOR/CEILING WOOD-FRAMED:
(38x140mm) PLATES D2 NOT PERMITTED IN - DOUBLE 5/8" GYP. WALLBOARD
- ABSORPTIVE MATERIAL ON NOT PERMITTED IN
EACH SIDE STC: 50-54 ACCORDANCE WITH BCBC THIS FLOOR TYPE CANNOT BE ACCORDANCE WITH BCBC - 5/8" SHEATHING U1
* THIS WALL DOES NOT TABLE A-9.10.31. FOUND ON MANUFACTURER'S TABLE A-9.10.31. - WOOD JOISTS @ 16" (400mm)
- 5/8" (15.9mm) TYPE ''X'' GYP. SITE.
WALLBOARD ON BOTH SIDES INCLUDE INSULATION, BUT o.c.
WAS THE CLOSEST POSSIBLE - BATT. INSUL
STC: 57 MATCH TO THIS WALLTYPE. STC: NOT RATED S1 - RESILIENT METAL CHANNELS @
8" (200mm) o.c.

STC: NOT RATED

ROOF ASSEMBLIES

R3 GEORGIA-PACIFIC
MANUFACTURER'S INFORMATION
PART 3 & 9 RATING
THIS FLOOR TYPE CANNOT BE
NOT PERMITTED IN FOUND ON MANUFACTURER'S R3
ACCORDANCE WITH BCBC SITE.
TABLE A-9.10.31.
STC: NOT RATED

#: DATE: REVISION
REVISIONS
CITYGATE ASSEMBLIES - STC CLIENT:
1/2" = 1'-0" BCIT CAMPUS

PROJECT:

FRR & STC RATINGS


3700 WILLINGDON AVENUE
BURNABY, BC
DRAWING NAME:

STC RATINGS

DATE: 28 APR 2020


SCALE: 1/2" = 1'-0"
DRAWN: J.S.
CHECKED: T.B.
DRAWING NO.:

A6.7.2