Hardware and Functionality 

Hardware and Functionality

Contents
1 Equipment Presentation 3
1.1 SRT 1F Applications 3
1.2 SRT 1F Highlights 6
1.3 SRT 1F Frequency Coverage 7
1.4 SRT 1F New K-shelf 8
1.5 SRT1F New compact layout 9
1.6 SRT 1F K-shelf Up to 7+1 AP/CC 10
1.7 Co-channel usage 11
1.8 SRT 1F K-shelf up to 2x(3+1) CC 12
1.9 SRT 1F K-shelf 2 x (3+1) E/W Single-rack Double Terminal 13
1.10 SRT 1F K-shelf 2 x (7+1) E/W Single-rack Double Terminal 14
2 Equipment Technical Description 15
2.1 System 16
2.2 SRT 1F K-shelf BRU section - Technical Details 18
2.3 SRT 1F K-shelf MSTU section - Technical Details 24
2.4 SRT 1F K-shelf Supervisory control and switching Sub-rack -Technical
Details 37
2.5 Equipment configuration 73
2.6 Radio protection system 88
2.7 GE Multi-Link Protection Switching Operation 96
2.8 Line Protection in BSW STM-1 Optical 1+1 DTI 97
2.9 Line Protection in GE ML 1+1 DTI 98
2.10 Synchronization 99
3 LED INDICATION 109
3.1 SV Unit LED 109
3.2 Other Unit LED 111
4 Unit Settings 115
4.1 MSTU setting 115
4.2 SV TL1/OSI unit 120

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
1
Hardware and Functionality

4.3 SV SNMP/IP unit 121


4.4 TCU Unit 123
4.5 BSW Electrical 124
4.6 Occ Interface Electrical unit 125
4.7 BSW Optical Unit 126
4.8 BSW Optical Unit 1+1 DTI 128
4.9 BSW GE Interface 131
4.10 GE Multi Link (L2) 133
4.11 AUX/LAN Unit 137
4.12 OWBR Unit 138
4.13 RS Enhanced sub-module 140
4.14 RUC SUB-Modules 141
5 Unit Replacement 145
5.1 MSTU and Other Units 146
5.2 SV TL1/OSI unit Replacement 147
5.3 SV SNMP Unit Replacement 148
6 Network management 155
6.1 TL1 SVProtocol Overview 155
6.2 DCN Communication Protocol with TL1 SV 158
6.3 SV SNMP Unit Protocol overview 159
6.4 DCN Communication Protocol with SNMP SV 161
7 Technical characteristics 165

FT42323EN02GLA2
2 © 2010 Nokia Siemens Networks
Hardware and Functionality 

1 Equipment Presentation

1.1 SRT 1F Applications

SRT 1F Applications
Transport Network – Fixed/Mobile Operators

STM-4 / 16 Ring

Back up to the Fiber


Ring closure

Regional
STM-16 Ring /National Radio
Backbones
3x STM-1
High Capacity
Regional Subnetworks

Fig. 1 Transport Network - Fixed Operators

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
3
Hardware and Functionality

SRT 1F Applications
Evolving towards Ethernet transport

1st Mile Aggregation Backbone

 SRT 1F Trunk Radio as alternative or


complementary to fiber in backbone
transport
 Connection to IP network devices through SRT1F

GB Ethernet interface (GE BSW)


 TDM traffic still supported through STM-1
interface (BSW)

Trunk Radio-SRT1F Multi-reach DWDM IP Core and Edge Routers, Multi-Service


Routers for RAN/Mobile Packet core

Fig. 2 Infrastructure for Mobile Network

FT42323EN02GLA2
4 © 2010 Nokia Siemens Networks
Hardware and Functionality 

SRT 1F Applications
TDM/Ethernet Backbone

MxSTM-1 TDM
+
NxSTM-1 Ethernet
BTS
E1
NB
E1
Eth
BSC
First Mile E1
First Mile
++
Aggregation
Aggregation

BTS 1xGE on BSW GE


RNC
E1 (1+1 DTI protection)
Transparent Bridge STM1
Eth
NB
E1
PWE
Eth

SRT 1F
TDM/ ATM
Ethernet

Fig. 3 Multiservice Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
5
Hardware and Functionality

1.2 SRT 1F Highlights

Fig. 4 SRT 1F Highlights

FT42323EN02GLA2
6 © 2010 Nokia Siemens Networks
Hardware and Functionality 

1.3 SRT 1F Frequency Coverage

RF Band 4 5 L6 U6 7 8 11 13
(GHz)
3.6 – 4.2 3.8 – 4.2 4.4 – 5.0 5.9 – 6.4 6.4 – 7.1 7.1 – 7.4 7.4 – 7.7 7.7 – 8.2 10.7 – 11.712.7 – 13.3

Modulation
Format 64 128 64 128 64 128 128 128 64 128
(MLCM)

AP

CC

Fig. 5 SRT 1F Frequency Coverage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
7
Hardware and Functionality

1.4 SRT 1F New K-shelf

SRT 1F New K-shelf


SRT 1F SRT 1F
Multi-shelf K-shelf

Key Technical Features


 8 TRs per compact shelf
 Reducing BR network loss
 Optical Interface card

Old Multi-Shelf New K-shelf


Mechanical dimension W:446 x D:345 x H: 1500 W:486 x D:345 x H: 1150

Fig. 6 1.4 SRT 1F New K-shelf

FT42323EN02GLA2
8 © 2010 Nokia Siemens Networks
Hardware and Functionality 

1.5 SRT1F New compact layout

New K-shelf allows 8TRs in 1155 mm rack space.


Proper Expansion shelf is conceived for up to 16 TRs

Up to :
(7+1) AP/CC
or
Up to
2x(3+1) CC
2x(7+1) CC
or
or
3+1 East +
7+1 East + 3+1 West
7+1 West

Free Space can


be used to
house an ADM

Fig. 7 SRT1F New compact layout

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
9
Hardware and Functionality

1.6 SRT 1F K-shelf Up to 7+1 AP/CC

It supports all the configurations that


require no more than one protection
channel
P W2 W4 W6

1 3 5 7
V(H)
N+1 AP 2 4 6 8
H(V)
W1 W3 W5 W7

P W1 W2 W3 W4 W5 W6 W7

V(H)
N+1 CC
single pol 1 2 3 4 5 6 7 8

P W2 W4 W6

1 2 3 4 5 6 7 8
V(H)
N+1 CC
double pol
XPIC H(V)
W1 W3 W5 W7

Fig. 8 SRT 1F K-shelf up to 7+1 AP/CC

The SRT 1F can provide frequency allocation as follows:


• Alternated operation:
An STM-1 signal is transmitted by an RF frequency using an only polarization. Even
channels and odd channels shall use opposite polarization
• Co-channel operation:
Up to two STM-1 signals can be transmitted simultaneously by an RF frequency
using dual polarization (CCDP), thus doubling the spectrum efficiency. The
transmission capacity of Way side and User channel will be doubled through CCDP
operation.

FT42323EN02GLA2
10 © 2010 Nokia Siemens Networks
Hardware and Functionality 

1.7 Co-channel usage


WARNING
Care vs N+1 with CC reuse!

• When selective fading occurs on one of the used frequencies, both channels V
and H are in outage and they cannot be saved both by the single protection P.
• Note that this impairment is a matter of propagation physics, and cannot be
solved by any type of 3rd party vendor system.
• Example: fading on ch3: W4 and W5 are in outage, but only one can be saved by
P;W4 stays in outage!

P W2 W4
The example here is tailored LOS
upon the 5+1 configuration,
1 2 3
but is applicable to any other
N+1 configuration

W1 W3 W5
LOS
saved
by P

Fig. 9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
11
Hardware and Functionality

1.8 SRT 1F K-shelf up to 2x(3+1) CC

It supports all the configurations with two


protection channels
P1 W11 W12 W13

1 2 3 4 5 6 7 8
V(H)
2x(3+1) CC
H(V)
P2 W21 W22 W23

In conjunction with Expansion K-shelf it is possible


to equip 16 TRs in one rack

P1 W11 W12 W13 W14 W15 W16 W17

1 2 3 4 5 6 7 8
V(H)
2x(7+1) CC
H(V)
P2 W21 W22 W23 W24 W25 W26 W27

Fig. 10 SRT 1F K-shelf up to 2x(3+1) CC

FT42323EN02GLA2
12 © 2010 Nokia Siemens Networks
Hardware and Functionality 

1.9 SRT 1F K-shelf 2 x (3+1) E/W Single-rack Double


Terminal

M+1 East, N+1 West


East
direction Repeater/ Back to Back
3+1
(M and N can be different)

free space available Metro


for ADM hiT 7020, Network
hiT 7025, hiT 7030,
hiT 7035, hiT 7060

STM-
STM-1 STM-
STM-1
STM-
STM-1 STM-
STM-1
N+1 M+1
Configuration Configuration

Fig. 11 K-shelf 2 x (3+1) E/W Single-rack Double Terminal

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
13
Hardware and Functionality

1.10 SRT 1F K-shelf 2 x (7+1) E/W Single-rack Double


Terminal

M+1 East, N+1 West


East
direction Repeater/ Back to Back
3+1
(M and N can be different)
expanded

to 7+1

Metro
Network

STM-
STM-1 STM-
STM-1
STM-
STM-1 STM-
STM-1
N+1 M+1
Configuration Configuration

Fig. 12 K-shelf 2 x (7+1) E/W Single-rack Double Terminal

FT42323EN02GLA2
14 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2 Equipment Technical Description

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
15
Hardware and Functionality

2.1 System
The SRT 1F radio equipment is designed to transmit STM-1 (155.520 Mb/s) signals.
The SRT is equipped with N+1 Radio Protection System (RPS).
The SRT1F radio equipment is available in 3 versions:
• SRT 1F K-shelf configuration, up to 16 transceiver units can be housed in one rack
• SRT 1F Multi-shelf configuration, up to 8 transceiver units can be housed in one
rack
• SRT 1F 1+1 N.E., compact solution for max 1+1/2+0 configuration

SRT 1F K-shelf model is composed by the following parts/shelves:


• K-shelf up to 7+1: Includes RF Branching Network, MSTU section, SCS section,
User Interface Area (UIA) in a single compact shelf, 1155mm high. It can be used
in conjunction with MCF/Controller card for single RPS protection, for N+1 terminal
in one rack, N<8. Or in conjunction with MCF/Controller card for double RPS
protection, for 2x(N+1) single terminal in two racks, N<8.
• K-shelf up to 2x(3+1) ST: Includes RF Branching Network, MSTU section, SCS
section, User Interface Area (UIA) in a single compact shelf, 1155mm high. It can
be used in conjunction with MCF/Controller card for double RPS protection, for
2x(N+1) single terminal in one rack, N<4.
• Expansion K-shelf ST: Includes RF Branching Network, MSTU section, SCS
section, User Interface Area (UIA) in a single compact shelf, 930mm high. It can
be used in conjunction with K-shelf up to 2x(3+1) ST, for 2x(N+1) single terminal
in one rack, 3<N<8.
• K-shelf up to 2x(3+1) DT: Includes RF Branching Network, MSTU section, SCS
section, User Interface Area (UIA) in a single compact shelf, 1155mm high. It can
be used in conjunction with up to two MCF/Controller cards for single RPS
protection, for 2x(N+1) double terminal in one rack, N<4.
• Expansion K-shelf DT: Includes RF Branching Network, MSTU section, SCS
section, User Interface Area (UIA) in a single compact shelf, 930mm high. It can
be used in conjunction with K-shelf up to 2x(3+1) DT, for 2x(N+1) double terminal
in one rack, 3<N<8.
• BBIU (optional): Base-Band Interface Unit with Baseband Interface for STM-1
Optical. Multiplex Section Protection Switches (MSPSW) are also housed in this
unit. The BBIU is optional shelf to be equipped in case of need of Multiplex Section
Protection (MSP). It is not applicable in case of K-shelves up to 2x(3+1). SRT 1F
1+1 N.E. model is composed by the following parts:
SRT 1F 1+1 N.E. shelf: includes all the functional blocks installed in a single shelf,
503mm high (588mm including BRU C/W adapters)

FT42323EN02GLA2
16 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 13 SRT1 F Block Diagram

Fig. 14 SRT 1F Mechanics and Layout

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
17
Hardware and Functionality

2.2 SRT 1F K-shelf BRU section - Technical Details


• Filters are the same for AP and CC
• Each filter couples two channels
• The standard RF filters coupling is at 56/80 MHz channel spacing
E.g.: 1-3, 3-5, 5-7, 2-4, 4-6, 6-8
• Other coupling are NON standard, but can be developed on request
E.g.: 1-5 is not standard
• Adjacent channels coupling is NOT available and cannot be developed
E.g. : 1-2 is not possible
• Band Elimination Filter (BEF) may be required in order to guarantee necessary
TX/RX separation between innermost channels, in case they are used inside the
same antenna branching.

Fig. 15 BRU section

FT42323EN02GLA2
18 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 16 New Branching

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
19
Hardware and Functionality

2.2.1 Branching configurations

Fig. 17 Example 1

FT42323EN02GLA2
20 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 18 Example 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
21
Hardware and Functionality

Fig. 19 Example 3

FT42323EN02GLA2
22 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 20 Example 4

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
23
Hardware and Functionality

2.3 SRT 1F K-shelf MSTU section - Technical Details

Fig. 21 MSTU Section

2.3.1 Transceiver Unit description,(MSTU)


The Transceiver Unit is an all-in-one unit that receives the STM-1 base band (BB)
electrical signals and, after processing, it outputs the converted signals to the
antenna port via RF Branching section at the required Radio Frequency.
All the functions required for the signal processing are enclosed in this unit: it
implements multi-level QAM (64/128) and the corresponding demodulation; it
processes the required SOH bytes and pointers; it converts signals into 1st IF
(70MHz), then (via synthesizer) to RF through 2nd IF (844MHz).
The STM-1 electrical signals are output from the Transceiver to the outside via the
BSW unit inside SCS section for N+1 RPS switchover (bipolar switchover) in the
event of a Transceiver failure.
Moreover, to reduce random errors in transmission paths, the MLCM error correction
method is used.

FT42323EN02GLA2
24 © 2010 Nokia Siemens Networks
Hardware and Functionality 

In addition to the main signals, the Transceiver also processes the input and output
signals of the 2x2Mb/s Way Side traffic (one on SOH and one on RFCOH) and of the
user channel using the F1 byte. These signals are accessed through BSW unit in the
same way as the main signals.
The unipolar switch and Space Diversity DADEing functions are implemented in the
unipolar stage to switchover from any of working channel to protection channel
against fading.
The orderwire bytes (E1, E2), DCC, Service Channels, MCF data, and RPS
switchover data are processed in the Supervisory, Control & Switching section.

Fig. 22 MSTU Features

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
25
Hardware and Functionality

Fig. 23 MSTU Layout

FT42323EN02GLA2
26 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 24 Functions of MSTU Front Panel

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
27
Hardware and Functionality

Fig. 25 Transceiver Block Diagram

FT42323EN02GLA2
28 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 26 Transceiver Description

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
29
Hardware and Functionality

2.3.1.1 XPIC Module


XPIC module (mounted on Transceiver Unit board) consisting in an adaptive
transversal filter, provides effective countermeasure and superior cancellation
performance also in presence of non-nominal propagation conditions.
Co-channel operation with high level modulation schemes requires very high cross-
polarization discrimination (XPD).
Modern radio relay antennas meet the XPD requirements at least under ideal
propagation conditions; nevertheless cross-polarization interference (XPI) between
orthogonally arranged channels may increase under particular conditions such as
rainfall or multipath propagation. As additional means to counteract these
phenomena, a powerful cross-polarization interference canceller device has been fit
into the demodulator. Since the interference effects are time variable, the XPIC
device structure is adaptive, consisting also of a 11 tap transversal filter.
Due to the chosen XPIC concept no common use or synchronization of the L.O. of
vertical and horizontal channels is required at transmit side.
At receive side, beside the exchange of the received data signals at IF level, the only
interconnection between vertical and horizontal channel is the L.O. synchronization
of the receivers and no additional clock synchronization of the demodulators is
necessary.

Fig. 27 X-PIC Module

FT42323EN02GLA2
30 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 28 XPIC INTERCONNECTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
31
Hardware and Functionality

2.3.1.2 MSTU Digital Processing


The SRT 1F system uses three kinds of overhead bit to transfer the signals for
system supervise/control and user’s utilization.
In addition to the Multiplex Section Overhead (MSOH) and Regenerator Section
Overhead (RSOH) of STM-1 frame, the Radio Frame Complementary Overhead
(RFCOH) is provided inside the overall radio frame.
If MCF/Controller type TL1/OSI is used, only MS mode is applicable.
If MCF/Controller type SNMP/IP is used, the operational mode can be set as MS
mode or RS mode via LCT.

Fig. 29 Mstu Digital Processing

FT42323EN02GLA2
32 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.3.1.2.1 RSOH and MSOH

Fig. 30 STM1 Frame

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
33
Hardware and Functionality

Fig. 31 SOH Bytes

FT42323EN02GLA2
34 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.3.1.2.2 RFCOH
The Radio Frame Complementary Overhead (RFCOH) transfers one class of signals
for internal use to monitor/control the SRT 1F system, one class of signals for user’s
utilization (WS RFCOH and optional RUC), and a set of dummy bits.
The following table shows the composition of the RFCOH frame and the contribution
of SOH and RFCOH frames to total gross bit rate:

Fig. 32

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
35
Hardware and Functionality

FT42323EN02GLA2
36 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4 SRT 1F K-shelf Supervisory control and switching


Sub-rack -Technical Details

Fig. 33 SCS Section

The SCS section provides supervisory and control function, including alarm/event
information management and provisioning data setting. It consists of the following
units: MCF/Controller, BSW unit and Timing Source Unit (TSU).

• MCF/Controller: it implements the supervisory and control functions for


Transceiver Unit; manages and controls RPS-USW and RPS-BSW; terminates the
E1 and E2 order wire bytes (EOW); terminates the DCC line; sets security levels of
operators; manages bit error performance, analogue monitoring and event
monitoring. It can be chosen TL1/OSI or SNMP/IP. For SNMP/IP type, MST or
RST operational mode can be configured. For TL1/OSI, MST mode is possible
only.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
37
Hardware and Functionality

• BSW: it is the Base Band physical interface for STM-1 signals. It implements a
switchover in the bipolar stage for any of Transceiver failure. The required number
of BSWs is the same as the number of RF working channels. It can be Electrical or
Optical (S-1.1 or L-1.1 via SFP optical module) or GigaEthernet (1000BaseSX or
1000BaseLX or 1000BaseT via SFP module). Also DTI (Double Tributary
Interface) cards are available to provide the tributary protection: BSW Optical 1+1
DTI provides two STM-1 protected by redundancy of SFP module for each STM-1
traffic (is large twice a standard BSW, to have two STM-1 protected in a single
card), the relevant MSP logic being demanded to external ADM. BSW
GigaEthernet 1+1 DTI provides two GigaEthernet interfaces on two SFP modules
for protection of the data via STP (Spanning Tree Protocol) implemented in an L2
switch integrated inside the card.
• TSU: it supplies clock signals for system synchronization in case of MST mode.

• The SCS section can have the following optional units installed:
• up to two Embedded Channel units (ECU) to increase DCC management
capability;
• up to two housekeeping (HK) units to increase supervisory and control capability
of external communication equipment;
• one redundancy TSU;
• one Occasional Interface unit (electrical or optical or GigaEthernet) for occasional
traffic on protection channel; and one BSW INTF for 2x(N+1) single-controller
operation.
• Eow Branching Unit to Allow branching of up to 5 EOW extension
• Aux/lan converter In case of mixed networks osi and snmp

FT42323EN02GLA2
38 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.1 SV Unit
MCF/Controller unit to supervise/control the Radio Protection system. SV card is
available as TL1/OSI protocol stack type or SNMP/IP protocol stack type.
SV card can be provided as single RPS type (RPS1) or double RPS type
(RPS1/RPS2). In this second case, the RPS2 control is demanded to a dedicated
RPS2 sub-unit inside the SV card.
SV card TL1/OSI type supports MST operational mode only (RST mode is not
supported by TL1/OSI SV), so that timing control unit (TCU) shall be equipped as
mandatory item. SV card SNMP/IP type supports both RST and MST modes, so that
TCU is optional item, required only if MST mode is required.
The main function of SV unit is:
• Terminate Orderwires, User Channels and DCCs.
• Provide F-Interface for Local Craft Terminal and Q-Interface for Network
Management System.
• Retrieve/register alarm/status data for protection control and indication.
• Retrieve/register Performance Monitoring data.
• Control the RPS at bipolar and unipolar signal level.
• Control the MSP (for STM-1 MS optical interface only).
• Provide Orderwire functions.
• Register the NE setting (provisioning) data.
• Relay Housekeeping (8DI item input and 4DO item output)

Data Back-up
TL1/OSI type of MCF/Controller card is supplied with a proper EEPROM for back-up
of SV data.
In SNMP/IP type of MCF/Controller card no EEPROM back-up is provided, but full
configuration data can be stored on laptop by proper HOTTOOL software tool.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
39
Hardware and Functionality

Fig. 34 SV unit

FT42323EN02GLA2
40 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 35 SV management

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
41
Hardware and Functionality

2.4.1.1 Optional sub-module for RUC (RFCOH User Channel)


SRT1F provides as standard one user channel 64kbps G.703 (using F1 byte of SOH)
per each STM-1 working channel equipped with BSW Electrical or BSW Optical 1+0.
Additionally, up to two optional 64kbps user channels using RFCOH can be added,
by mounting the proper sub-module on the MCF/Controller card. One sub-module is
required per each RUC to be added.

TIP
Note that in case of BSW GigaEthernet and BSW OPT 1+1 DTI, no standard user
channels are available, so the only way to have user channels is to exploit the
optional capability of RFCOH user channels.
The ordering codes of the RFCOH user channel sub-modules are different for the
cases of TL1/OSI controller or SNMP/IP controller.
The equipping rule is:
maximum quantity is two per each MCF/Controller card. Even mixed choice among
the three types is possible (e.g. one RUC DGTL G.703 plus one RUC V.11 in the
same MCF/controller card).

. Further, it is necessary to specify, for each sub-module, if it shall be supplied as


digital (DGTL) or analog (VF). The relevant specifications are indicated in the
following tables.

FT42323EN02GLA2
42 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Digital (DGTL) Interface G703


Impedance 120 Ω
Type G.703 co-directional or contra-directional

Connector Dsub 25
Connector Location SCS backplane

Quantity of Connectors 1 connector for up to two channels,


in common with VF Interface

Voice Frequency (VF) Interface


Impedance 600 Ω
Input nominal level (Tx) -16 dBr
Input level range -16 to -0.5 dBr, 0.5 step
Output nominal level (Rx) +7 dBr

Output level range -8.5 to +7 dBr, 0.5 step


Maximum voice level 3 dBm0
Amplitude Response G.712
Signal to Distortion G.712
Connector Dsub 25

Connector Location SCS backplane

Quantity of Connectors 1 connector for up to two channels,


in common with DGTL Interface

Digital V.11 Interface


Impedance 120 Ω
Type V.11 contra-directional

Through-repeater function Not supported


Connector Dsub 25

Connector Location SCS backplane


Quantity of Connectors 1 connector for up to two channels,
in common with VF and digital G.703 Interface

If the RUC sub-module is ordered together with the MCF/Controller card, the RUC
sub-module is already mounted at factory on the MCF/Controller card, so this
paragraph can be neglected. If instead the RUC sub-module is ordered later on with
respect of the MCF/Controller, in order to increase the availability of user channels in
the SRT1F terminal, please refer to the following instructions to learn how to mount in
field the RUC sub-module.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
43
Hardware and Functionality

Please refer to the following figure.


1. the red circles in the photo show the screws positions of the two locations of the
two RUC sub-modules which can be mounted on a MCF/Controller card (SV
card).
2. the screws are already attached in the SV card.
3. so, first loosen the screws off from the SV card.
4. insert the RUC sub-module (VF or DGTL) on the SV card.
5. then, screw back the screws.

TIP
Please note that the RUC sub-module in the SV card shall be mounted in the same
location (same order) for both the near end SV card and the far end SV card. In fact,
as shown in the figure below, there are two locations for RUC sub-module in the SV
card. Each RUC sub-module can be mounted either in the left side location or in the
right side location, but same location shall be accomplished for both SV cards at both
end terminals of each hop, in order to match consistency of RUC operation. For
instance, in the above figure, two RUC sub-modules are mounted, one DGTL and
one VF. In the remote end terminal, the same equipping scheme shall be
accomplished, with one DGTL RUC and one VF RUC in the same order as the near
end station.

FT42323EN02GLA2
44 © 2010 Nokia Siemens Networks
Hardware and Functionality 

RUC sub-
modules
SV card

Fig. 36 Ruc Sub-Modules

Analogue RUC

G703 RUC

V11 RUC

Fig. 37 RUC Block Diagrams

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
45
Hardware and Functionality

2.4.1.2 DCC management (SNMP/IP SV)


In SNMP/IP type MCF/Controller, a DCCR or DCCM line (DCCM line option is
available if TCU is equipped and MST mode is selected) is available as standard,
transmitted by the Main 1 channel and Protection channel for parallel path duplication
RPS.
For double RPS version of SNMP/IP type SV, the DCCR or DCCM line of the RPS2
can be enabled by equipping the optional ECU SNMP/IP unit

DIRECT HANDLING:
• DCCR
RSOH bytes D1 ÷ D3
Capacity 192 kbit/s
Channel Main 1
Side Line / Radio
Or (SW selectable if TSU is equipped)
• DCCM
RSOH bytes D4 ÷ D12
Capacity 576 kbit/s
Channel Main 1
Side Line / Radio

HANDLING with 1 ECU SNMP/IP (optional) equipped - applicable to double RPS


SV only
• RPS2 DCCR
RSOH bytes D1 ÷ D3
Capacity 192 kbit/s
Channel Main 1
Side Line / Radio
Or (SW selectable if TSU is equipped)
• RPS2 DCCM
RSOH bytes D4 ÷ D12
Capacity 576 kbit/s
Channel Main 1
Side Line / Radio

FT42323EN02GLA2
46 © 2010 Nokia Siemens Networks
Hardware and Functionality 

DCCM unit

Fig. 38 DCC SV SNMP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
47
Hardware and Functionality

2.4.1.3 DCC management (TL1/OSI SV)


In TL1/OSI type MCF/Controller, a DCCR line is available as standard, Transmitted
by the Main 1 channel and Protection channel for parallel path duplication RPS. DCC
capabilities of TL1/OSI type SV can be improved by equipping up to two optional
ECU TL1/OSI units.

FT42323EN02GLA2
48 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 39 Dcc TL1/ osi SV

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
49
Hardware and Functionality

2.4.1.4 Orderwire Function


Two fully independent EOW channels, E1 and E2, are provided.
To use an orderwire, connect an ordinary 2-wire telephone set to E1-2W or E2-2W
modular jack. The station is selectively called through the telephone key-pad by
DTMF method.
Four calling digits are used as follows:
• Two (2) digits for group number (G1, G2)
• Two (2) digits for station number (G3, G4)
When calling, (#,G1,G2,G3,G4) is dialed by push-phone TEL.
Two types of dialing method are available.
• Selective station calling: (#,G1,G2,G3,G4)
• Omnibus broadcast calling: (#,G1,G2, * , * )
4-wire VF in/out ports are available on the SCSU backplane for the connection
to/from other equipment of E1 and E2 EOW.
In case of nodal SRT1F station with more than two SRT1F terminals, the EOW inter-
connection is generally done by acting on co-located MUX settings.
In order to ease the EOW inter-connections in SRT1F nodal stations, a new unit has
been developed and commercially available to allow branching of up to 5 EOW
extensions per terminal, per each EOW channel (E1 and E2).
The ordering code is different depending on the type of controller card equipped,
whether TL1/OSI or SNMP/IP.
One unit allows branching up to 3 EOW extensions per terminal for E1 and E2, while
two units allow branching up to 5 EOW extensions per terminal for E1 and E2
The card is equipped in one of the two slots available adjacently to the SV controller
card slot. If such slots are already used for other optional cards (ECU card, AUX/LAN
card) of course they cannot be used for OWBR. For the case of expansion to 5 EOW
extensions (two OWBR cards needed), of course both slots adjacent to SV controller
card shall be available (not used for other optional cards).

FT42323EN02GLA2
50 © 2010 Nokia Siemens Networks
Hardware and Functionality 

EOW

Eow+1 Owbr

Eow+2 Owbr

Fig. 40 EOW+OWBR

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
51
Hardware and Functionality

Fig. 41 Example of use of OWBR in three-terminals SRT1F site - logic scheme

FT42323EN02GLA2
52 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.1.5 Housekeeping
The system allows as standard up to 8 DI (Digital Inputs) for collection of external
station alarms plus 4 DO (Digital Outputs) for remote telecontrol of station devices
(housekeeping function)
The number of housekeeping DI/DO ports may be increased by equipping up to two
optional HK units. The correspondent number of DI/DO is reported in the following
figure:

Fig. 42

WARNING
House Keeping unit for TL1/OSI Controller are Different respect to those one
for SNMP/IP SV.
NOTE: When Optical /Gb ETH BSW interface units are installed, ALM/CONT informations are monitored
through HK unit, if necessary.
Allowable DI/DO items for external equipment are in the following figure:

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
53
Hardware and Functionality

Fig. 43 No. of DI/DO items in the presence of OPT BSW/GE BSW

2.4.1.5.1 HK & 120/75 Impedance Converter (HK CONV)


Optional HK CONV unit includes HK unit plus 120/75 Impedance Converter. 120/75
impedance converter is provided for Dsub 9-pin 120-ohm interface to 1.0/2.3 coaxial
type 75-ohm interface for Wayside Traffic channel when OPT BSW DTI or GE BSW
unit is installed.
This HK CONV unit can be installed to the HK unit slot.

FT42323EN02GLA2
54 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.1.6 Rack Alarm Bus (RAB)


Visible and Audible Warning, Minor, Major, Critical and General alarms are supported
by the controller and relayed to an external panel via proper RAB connector on the
backplane.
In TL1/OSI controller, all the available alarms are supported as standard on the RAB
connector.
In SNMP/IP controller, only the general alarm is provided as standard, while all the
other alarms are enabled via proper RAB sub-module to be equipped on the
controller card.

RAB sub-module

Fig. 44 RAB Module

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
55
Hardware and Functionality

2.4.2 AUX/LAN card


This unit can be plugged in each one of the ECU slot of the SCS section of the
SRT1F (K-shelf or Multi-shelf), in conjunction with MCF/controller SV card TL1/OSI
type (it cannot be plugged in conjunction with MCF/Controller SV card SNMP/IP
type). It provides the conversion of an IP DCN LAN to 1x64kbps or to 1x2Mbps
channel for forwarding via standard user channel (standard F1 SOH byte or optional
RFCOH RUC) or wayside channel (standard SOH WS or standard RFCOH WS) of
SRT1F radio. Even embedded Drop/Insert (D/I) capability is available as 2x64kbps
add/drop and 2x2Mbps add/drop, in order to allow IP DCN LAN drop/insertion in a
user channel or wayside channel in nodal stations where IP DCN LAN drop/insert is
required.

The native application of this unit is to support IP DCN of the new MCF/controller SV
card SNMP/IP in existing SRT1F networks where the MCF/controller SV card is
TL1/OSI type (OSI DCN), as a valuable alternative to IP over OSI tunnelling via Dual
Q-Adapter (which would overload the existing OSI DCN). The choice of the AUX
capacity (64kbps or 2Mbps) depends on the estimated required capacity for the
SRT1F SNMP/IP sub-network DCN to be AUX-converted. At this purpose,
considering that average capacity required by each SRT1F Network Element (NE =
Network Element = MCF/controller) is 4 kbps, it can be assumed that 64kbps AUX
channel is enough for up to 16 NE’s, whilst 2Mbps AUX channel can support even a
full DCCR (192kbps) or DCCM (576kbps) capacity, or even more DCCR’s and/or
DCCM’s (up to maximum limit of 2Mbps), thanks to the drop/insert capability, which
substantially allows to cluster in a single AUX channel all the IP DCN’s relevant to
separate SNMP/IP sub-networks across the TL1/OSI original network
The following figure shows the schematic application.

FT42323EN02GLA2
56 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 45 Schematic application of AUX/LAN converter

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
57
Hardware and Functionality

2.4.3 BSW INTERFACES

2.4.3.1 BSW Electrical Unit


• STM-1 tributary interface
• Bipolar Switch for N+1 protection
• 2 wayside channels 2Mbps
• Very High MTBF 4000 hours
• Passive-only components in BSW serial part

Fig. 46 BSW Electrical

FT42323EN02GLA2
58 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.3.2 BSW Optical Unit


• Installed in same slots of electrical BSW (in alternative)
• Electrical and Optical BSW can coexist in the same rack
• SFP (Small Form Factor Pluggable) module can be changed in case of failure (no
need to change the complete unit)
• No MSP protection

Fig. 47 BSW Optical Interface

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
59
Hardware and Functionality

2.4.3.3 BSW Optical 1+1 DTI


• HW protection of Optical STM-1 to support MSP
• STM-1 SFP module S-1.1 or L-1.1 or others
• Switch Initiators: LOS, LOF, MS-AIS, B2ERR
• SOH Wayside channel available as 120Ω only
• RFCOH Wayside channel available as 120Ω only
• F1 User channel not available
• Up to 2x64k aux channel available via optional
RUC submodule on SV card

Fig. 48 BSW Optical Interface 1+1DTI

FT42323EN02GLA2
60 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.3.4 BSW GE Interface on 1 STM1, (L1)


• GE interface via SFP module on BSW GE
• Up to 8 GE interfaces in one k-shelf
• 1+1 DTI protection
• SOH/RFCOH Wayside channels available as 120Ω only
• F1 User channel not available
• Up to 2x64k aux channel available via optional RUC sub-module on SV card

GE Features
• Transparent bridge function only
• L2 Switching capabilities, priority schemes, QoS, shall be demanded to external
router
• Fully transparent to any type of Ethernet frame
• Jumbo frame supported
• Efficient SDH mapping of GE traffic
The card acts as a Layer-1 media converter device. GigaEthernet data are mapped
into SDH frame by means of proprietary mapping with typical throughput 125Mbps

GbE

GbE

Switching capabilities, priority schemes, QoS,


shall be demanded to external router

Fig. 49 GE interface x1 STM1

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
61
Hardware and Functionality

FT42323EN02GLA2
62 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.3.5 GigaEthernet Interface L2, (ML)


In addition to the GigaEthernet interface L1 (briefly called BSW GE) already available
in SRT1F portfolio, the GigaEthernet interface L2 (Layer-2 = Ethernet switch) is now
added to complete the GE portfolio. The main feature of this new interface is the
presence of dual port GE (for 2+0 or 1+1 DTI configuration) and the ML (Multi-Link)
mapping function on NxSTM-1 capacity, with 1<N<9 (minimum N=2), thus this
interface is briefly called GE ML, to differentiate it from the already available BSW
GE.

The basic functions of the new GE ML are distributed between two main units:

• NXSTM-1 GE ML INTERFACE 2+0/1+1 DTI L2 - MASTER


• NXSTM-1 GE ML INTERFACE 2+0/1+1 DTI L2 - SLAVE

The master unit basically provides the two GE user ports. The slave unit instead
provides the L2-switch function, including the load balancing among the NxVC-4
available capacity.
The minimal set for the GE ML is composed by one master unit and one slave unit
only: with this minimal set of units, the GE interface is mapped on 2xSTM-1 capacity.
For mapping over more than 2xSTM-1, let’s say NxSTM-1 with N>2, it is necessary to
add N-2 dedicated GE ML adapter cards, which can be chosen between following
two codes:
• STM-1 ADAPTER CARD FOR NXSTM-1 GE ML 2+0/1+1 DTI
• STM-1 OCCASIONAL ADAPTER CARD FOR NXSTM-1 GE ML 2+0/1+1 DTI
Between these two units of GE ML adapter cards, the second one (Occasional) is
used to include, among the mapped STM-1’s of the GigaEthernet, the protection
channel of the TDM section of the SRT1F terminal. In particular, in case of a hybrid
terminal with NxSTM-1 TDM protected in N+1 configuration and a GE ML unit to be
mapped over MxSTM-1 independent from the N+1 TDM section, the protection
channel of the N+1 TDM section can be accessed by means of the Occasional
Adapter GE ML, in such a way that the GE ML is actually mapped over M+1 streams
STM-1 in normal conditions (i.e. when protection channel is not needed by TDM
section). Similarly, in case of a hybrid terminal with NxSTM-1 TDM protected in N+2
configuration and a GE ML unit to be mapped over MxSTM-1 independent from the
N+2 TDM section, the two protection channels of the N+2 TDM section can be
accessed by means of qty2 of the Occasional Adapter GE ML, in such a way that the
GE ML is actually mapped over M+2 streams STM-1 in normal conditions (i.e. when
protection channels are not needed by TDM section). In other terms, the protection
channel is shared between the TDM section (for which it is used as Freq Div reserve
channel in case of fading or failure) and the GigaEthernet section (for which it is used
to increase the GE capacity during normal propagation conditions), thus optimizing
the spectral efficiency of the system.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
63
Hardware and Functionality

The following cable is mandatory (qty1 per each GE ML set) to interconnect the
MASTER and SLAVE cards:
• GE ML MASTER-SLAVE CABLING KIT
The following cable is mandatory (qty 1 per each GE ML adapter card) to
interconnect the SLAVE card with each ADAPTER card:
• GE ML CABLE FOR ADAPTER CARD

master slave adapter … adapter

GbE

GbE


Load-balancing cabling

Fig. 50GE ML Equipping rule in SRT1F K-shelf

2.4.3.5.1 STM-1 transportability of the GE at repeater sites.


The GE ML shall be equipped only in the two end terminals of a GE chain (i.e. only
where actually GE is needed to interface the Ethernet device located at the end
terminal), whilst in the pure E/W repeater sites, the SRT1F can be equipped with
standard STM-1 BSW and OCC card Electrical (or Optical, if preferred). This
simplifies remarkably the network design and performances, taking the maximum
vantage from the EoS (Ethernet over SDH) mapping, because it makes maximum
use of high reliability and cost-effectiveness of STM-1 Electrical interface, and
minimizes the end-to-end latency in a GE route.

FT42323EN02GLA2
64 © 2010 Nokia Siemens Networks
Hardware and Functionality 

STM-1
STM-1
N+0 scheme : prot
repeater
repeater via adaptive load
GE balancing GE
Load balancing

#1
C-
#1
C-

VC-4

V
V

4
4

#2 Load balancing
C-
#2
C-

VC-4

V
V

4
4

#3
#3

C-
C-

VC-4

V
V

4
4

#4
VC-4

C-
#4
C-

V
V

4
4

Fig. 51 Mapping of 1 GE via 1x GE ML L2 in a 3-hops SRT1F chain in 4+0 radio configuration

The GigaEthernet L2 unit implements a L2-switch between two GE LAN ports (line
side) and one LAG (Link Aggregation) WAN port (radio side), performing
promiscuous listening on all its ports with store and forward mechanism from port to
port over one 128K packet buffer and CRC parity check to filter (discard) eventual
invalid Ethernet packets.

Fig. 52

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
65
Hardware and Functionality

The GE ML unit implements as default FIFO priority rule, and its design prevents any
type of Head of Line Blocking (HoLB) problem. Self-learning function with MAC
address table with capacity of 4K entries is also available as default feature (the
default MAC address table administration rule is: oldest MAC records are rewritten
when full). CSMA/CD Backpressure (jam sequence-driven backoff) is implemented
for Half Duplex operation (applicable for 1000BaseT), whilst IEEE 802.3x pause
frames Flow Control is implemented for Full Duplex operation as default feature.
Further, the following Ethernet features can be added by means of SW upgrade via
the dedicated RS232c management port:

• Static MAC address table administration (manual insertion/deletion of static MAC


addresses)
• Intelligent MAC address table administration rule (less used MAC records are
rewritten when full)
• Multicast traffic with IGMP (Internet Group Management Protocol) snooping
• Broadcast and Multicast Storm Protection
Bandwidth profile / rate limiting 64kbps, 128kbps, …, 1Mbps, 2Mbps, … 100Mbps,
per each port and per each packet type (unicast, multicast, broadcast)
• IEEE 802.1p/ ToS/ Port/ MACSA/ MACDA/ ACL/ CoS/ QoS with Strict Priority +
WFQ scheduling
• IEEE 802.1Q VLAN support (VLAN tag, VLAN access links, VLAN trunks, port-
based and MAC-based, up to 4096 VLAN ID)
• IEEE 802.1QinQ handling
• Performance monitoring as per RMON/ GroupMIB (RFC1757, 2819, 2021, 1213,
1573, see Appendix G)
• Port Mirroring
• IEEE 802.1AX (IEEE 802.3ad) Link Aggregation LACP (Trunking, Bonding, NIC
Teaming) at line side
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol

Note that Rapid Spanning Tree Protocol (RSTP) is generally requested in star/spurs
network topology. SRT1F is conceived for chain topology, where RSTP is not
recommended and STP is the best solution to implement protection (see Appendix F
for more details about STP implementation in SRT1F GE ML). Notwithstanding,
RSTP upgradeability is considered also among future candidates according to market
demand (refer to roadmap for commercial availability plan of any Eth features).

FT42323EN02GLA2
66 © 2010 Nokia Siemens Networks
Hardware and Functionality 

The unit uses proprietary EoS (Ethernet over SDH) mapping protocol to convert one
or two GigaEthernet data interfaces into one TDM stream NxSTM-1 to be forwarded
on air (1<N<9). On the line side the two available ports can be configured as
separate 2xGE ports (2+0 line side) or as 1+1 DTI line protected by means of line
LAG (Link Aggregation) and STP (Spanning Tree Protocol) functions. On the radio
side the traditional N+1 or N+2 configurations available with SRT1F system are not
applicable, because more conveniently the radio protection scheme is implemented
by making internal protection via adaptive load balancing among the NxVC-4
available.

Basically, the SRT1F equipped with GE ML handles dedicated health check packets,
which provide the information about the faulty status of a VC-4 stream. When a
failure is detected, that VC-4 is not used and the Ethernet traffic is distributed among
the (N-1) available VC-4 streams, until the faulty VC-4 is restored. This concept
strongly improves the spectral efficiency of the system, because instead of having a
standby channel used only in case of failure (which is approximately 1-to-10% of
time), the entire reserved spectrum is used fully in the normal propagation conditions
(which is approximately 90-to-99% of time), and reduced only during the abnormal
condition (failure or fading). This concept is valid not only in case the failure or fading
occurs in the GE ML end terminal, but also in the STM-1 repeaters of a GigaEthernet
chain, as depicted in following picture.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
67
Hardware and Functionality

FT42323EN02GLA2
68 © 2010 Nokia Siemens Networks
Hardware and Functionality 

STM-1 STM-1
repeater repeater

GE GE
Load balancing

VC VC VC VC
VC VC VC VC

#4 #3 #2 #1
#4 #3 #2 #1 VC-4

-4 -4 -4 -4
-4 -4 -4 -4

Load balancing
VC-4
VC-4 Health check Health check

VC-4

Failure detected in a STM-1 repeater site: health check packet signalling

STM-1 STM-1
repeater repeater

GE GE
Load balancing

VC VC VC VC
VC VC VC VC

#4 #3 #2 #1
#4 #3 #2 #1

VC-4

-4 -4 -4 -4
-4 -4 -4 -4

Load balancing
VC-4
not used during failure – automatic recovery at failure restore
VC-4

After health check packet signalling, the faulty VC-4 is inhibited from mapping

Fig. 53

The design of the EoS mapping protocol for SRT1F has been intentionally chosen
proprietary, in order to optimize the data mapping efficiency and adapt it for the
specific air radio frame designed in SRT1F system, optimizing as consequence
throughput and latency. Proprietary SRT1F EoS mapping efficiency results higher vs
standard GFP, providing faster Link Loss Forwarding (LLF), thus faster switching
time, and high throughput up to 150Mbps/STM-1 and minimum latency of just
23.5microsec/link end-to-end.
Furthermore, the proprietary EoS mapping protocol used in SRT1F implements also
a pseudo-synchronous Ethernet proprietary method to handle the transportation of
synchronization signaling.

Notwithstanding, it shall be noted that the SRT1F GigaEthernet interface is of course


compatible with any Ethernet frame generated by GFP protocol applied by an
external Mux or MW radio device using GFP.

More in general, the SRT1F GigaEthernet interface is transparent to any type of


Ethernet frame, included but not limited to VLAN, MacinMac, QinQ, any type of
MPLS frame and jumbo frames up to 9 Kbytes.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
69
Hardware and Functionality

The proprietary EoS mapping protocol maps the Ethernet traffic coming from the GE
port of each GE ML into NxVC-4, making optimal use of the capacity available for
throughput maximization. Parallel operation of separate and independent Ethernet
flows is thus possible, just considering separate BSW GE (L1) and/or GE ML (L2)
units, each one working upon a separate group of VC-4 containers, similar to VCAT-
like concept used in GFP method. This type of operation also allows easy bandwidth
profile handling (shaping) on NxVC-4 basis, at both line side and radio side, since
each GE unit has got intrinsically rate limiting to Nx150Mbps at both line and radio
side.

Although LCAS concept is not applicable for the GE ML of SRT1F, traffic protection is
anyhow implemented, as described above, at both line side (by means of port
duplication in conjunction with line LAG and STP) and at radio side (by means of
radio LAG with adaptive load balancing driven by health check packets).
Furthermore, the card is of course compatible with any Ethernet frame coming from
an external source implementing LCAS protocol (full interoperability with any
GFP+VCAT+LCAS system is guaranteed).

FT42323EN02GLA2
70 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.4.3.6 Optical, GE BSW Management


Controls and alarms for both BSW Optical and BSW GE are managed via connection
to SRT1F housekeeping facility.
4 DI plus 2 DO of housekeeping facility are needed per each BSW Optical card.
In case no more than two BSW cards per terminal are equipped, the standard SRT1F
housekeeping facility (providing 8 DI plus 4 DO) is enough to manage BSW.
In case more than two BSW per terminal are equipped, optional HK card (up to two)
can be equipped to increase housekeeping functionalities. In this case, the
connection to HK ports is made via backplane.

2.4.3.7 OCC Interface


• OCC card for occasional traffic on the protection path is available
• Electrical, Optical and GE versions are available
• No wayside channels 2Mbps are available for occasional traffic

STM-1(156M) CMI IN
OCC INTF
BSW(M1)
BSW(M2)
BSW(M3)
BSW(M4)
BSW(M5)
BSW(M6)
BSW(M7)
TCU
TCU

HK1
HK2

STM-1(156M) CMI OUT

SV

ECU 1

ECU 2 NFB

Connectors TERM

Fig. 54 STM1 OCC STM1 Interface

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
71
Hardware and Functionality

2.4.4 TCU unit


Incoming STM-1 Signal (LINE) to TCU, maximum 3 inputs
• From STM-1 tributary input (Tributary side)
• From MSTU receiver output (Radio side)
External Clock Input (EXT) to TCU, maximum 2 inputs
• 2.048 MHz or
• 2.048 Mb/s
It is not possible to set the STM-1 signal coming from protection MSTU receiver
output (Radio side) as synchronization timing clock source. It is not possible to set
STM-1 signal coming from occasional traffic card line input (Tributary side) as
synchronization timing clock source.
Input connectors for external clock are located in the connection area of the SCSU.
In case of signal source input loss the TCU generates the clock signal internally:
• Holdover mode, the system maintains clock accuracy of +/- 0.37 ppm for 24 hours.
After 24 hours, the clock accuracy is +/- 4.6 ppm.
• Internal free-running mode, +/- 4.6 ppm G.813.

Fig. 55 TCU Unit

WARNING
TCU unit (Must be installed in case of MS mode configurations!)

FT42323EN02GLA2
72 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.5 Equipment configuration


2.5.1 Ordering Guide
Assembling an SRT 1F terminal means to select the proper equipment from the
ordering guide. Please contact Nokia Siemens Networks’ Sales and Marketing dept.
for the current ordering guide.
The available configurations can be grouped into 6 classes. The following diagram
shows such classification. The drawings in next pages show ordering guide for each
class.
All the configurations are available at all bands, with or without Space Diversity, with
HP (High Power) or NP (Normal Power) transceivers (where applicable).
The configurations N+0 and 2x(N+0) can be considered as particular cases of the
N+1 and 2x(N+1) reported below.

Fig. 56 Available configurations with k-shelf

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
73
Hardware and Functionality

All K-shelf configurations with space diversity are available with just RX space
diversity, or with TX+RX space diversity. In case of RX SD, the SD circulator is a
simple RF adaptor (ADPT). In case of TX+RX SD, the SD circulator is a 3-poles RF
low-loss duplexer (DUP), same as TX/RX circulator. The following table clarifies the
use of ADPT and DUP depending on branching configurations:

FT42323EN02GLA2
74 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 57

WARNING
Note that for each direction of the Double Terminal on one rack, Space
Diversity configuration is not applicable if dual polarization is requested, due
to limitations on maximum number of waveguides run applicable per each
rack, which is limited to four (4).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
75
Hardware and Functionality

2.5.2 SRT 1F N+1 AP/CC (N < 8) Terminal Radio Equipment

Fig. 58

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
76 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 59 Layout of K-shelf up to 7+1 AP/CC

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
77
Hardware and Functionality

2.5.3 SRT 1F 2x(N+1) CC single-rack (N < 4) Terminal Radio


Equipment

Fig. 60

FT42323EN02GLA2
78 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 61 Layout of K-shelf up to 2x(3+1) CC

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
79
Hardware and Functionality

2.5.4 SRT 1F 2x(N+1) CC single-rack (3 < N < 8) Terminal Radio


Equipment

Fig. 62

FT42323EN02GLA2
80 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 63 SRT 1F 2x(N+1) Single Terminal (3 < N < 8) on one rack Radio Equipment

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
81
Hardware and Functionality

2.5.5 SRT 1F 2x(N+1) Single Terminal (N < 8) on two racks


Radio Equipment

Fig. 64

FT42323EN02GLA2
82 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 65 Typical Rack Configuration for 2x(N+1) CC double-rack

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
83
Hardware and Functionality

2.5.6 SRT 1F 2x(N+1) Double Terminal (N < 4) on one rack

Fig. 66

FT42323EN02GLA2
84 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 67

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
85
Hardware and Functionality

2.5.7 SRT 1F 2x(N+1) Double Terminal (3 < N < 8) on one rack


Radio Equipment with K-shelf version

Fig. 68 SRT 1F 2x(N+1) Double Terminal (3 < N < 8) on one rack Radio Equipment with K-shelf version

FT42323EN02GLA2
86 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 69

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
87
Hardware and Functionality

2.6 Radio protection system


The SRT 1F is equipped with the Radio Protection Switch system (RPS) to improve
signal transmission reliability. Automatic protection switch acts in case of equipment
failure and degradation of the propagation conditions. Manual switching is
implemented for testing and maintenance operation purposes.
One protection channel is provided for each switching group.
• N+1 operation: One switching group (RPS1 = Group 1) having 1:7 protection.
• 2x(N+1) operation: Two independent switching groups (RPS1 = Group 1 and
RPS2 = Group 2) having 1:7 protection each.
Maximum number of main channels is limited by the frequency band being utilized
(maximum 7 main channels per group).
Switching Stages
The Radio Protection System has two switching stages, bipolar switch (BSW) stage
and unipolar switch (USW) stage (.See Fig. 64).

FT42323EN02GLA2
88 © 2010 Nokia Siemens Networks
Hardware and Functionality 

TDP : Transmission Data Processing


RDP : Received Data Processing

Fig. 70 SRT1 F Block diagram

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
89
Hardware and Functionality

2.6.1 USW
The USW is part of the digital transmit/receive processor (TDP/ RDP) of MSTU. This
switch is supported by manual/automatic DADEing (Differential Automatic time Delay
Equalization) function between protection and any of main channels and performs
the hitless (errorless) switching against propagation fading.
Detailed USW information is as follows:
• Signal level: 8 streams of 19.44 Mbps rate, unipolar stage
• Direction: Uni-directional, Auto revertive
• Initiator: Loss of frame alignment (F LOSS), Signal degrade (BER ALM)

2.6.2 BSW
One BSW unit per main channel is mounted in the SCSU (Supervisory Control &
Switching Unit) section. This switch is not hitless and is dedicated to protect the
system against equipment failure. Manual protection switching is also not hitless but
can safely isolate a specific main channel from traffic transmission, for testing and
troubleshooting purposes.
Detailed BSW information is as follows:
• Signal level: STM-1 CMI, bipolar stage
• Direction: Bi-directional, Auto revertive
• Initiator: MSTU equipment alarm, MSTU power supply failure.

FT42323EN02GLA2
90 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 71 USW Example

Fig. 72 BSW Example

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
91
Hardware and Functionality

2.6.3 Switching priority and automatic switching model

Fig. 73

FT42323EN02GLA2
92 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.6.4 BER ALM Initiation Setting and Time to Initiate/Restore

Fig. 74

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
93
Hardware and Functionality

2.6.5 RPS characteristic


Automatic protection of RPS is initiated by;-
• Signal Failure : Frame alignment loss (F LOSS) of the Radio Frame
• Signal Degrade: Bit Error Ratio Alarm (BER ALM) of radio parity before forward
error correction.
Signal Failure (F LOSS alarm)
F LOSS alarm is initiated within 3 msec after frame synchronization loss and
recovered within 3 msec after establishing synchronization.
Signal Degrade
The threshold level of BER ALM can be set through the LCT. Fig. 74 shows the
setting position and time to initiate/recover of BER ALM.
Default setting is “2“.
USW Switching Time
The switching time is the switching total time.
Switching time = t1 + t2 + t3 +t4 (refer to Fig. 75):
• t1 = BER ALM detection time
• t2 = TX parallel transmission request time (propagation time) + TX USW switch
activation time (t2') + TX USW total answer back time (propagation time)
• t3 = Receive USW activation time
• t4 = RX USW total answer back time.
Manual switching time (t3+t4):
• without OCC: less than 5 ms;
• with OCC: less than 9.5 ms. In the manual switching time t1 and (t2-t2') are not
included.
DADE (Differential Absolute Delay Equalizer)
Automatic DADE (± 3 bits) functions to automatically synchronize two baseband
signals transmitted by a Main CH and Prot CH when carrying out protection
switching.
Manual DADE (± 16 bits): compensates the baseband signal path difference
between each Main CH and Prot CH.
Wait to Restore (WTR, option setting)

FT42323EN02GLA2
94 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Delay time from the detection of BER ALM restoration up to releasing protection
switching is available to eliminate unnecessary RPS operation when the propagation
condition is unstable.
If other channels fail during the WTR period, the WTR will be cancelled immediately
and Prot CH is taken over by the newly failed channel.

Fig. 75 Switching time

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
95
Hardware and Functionality

2.6.6 Occasional Traffic (option)


The lowest priority traffic can be transmitted by Prot CH when all channels are
normal. If a channel fails, the occasional traffic will be immediately disconnected to
remove traffic from the main failed channel.
Optional OCC card for electrical or optical interface shall be equipped in the first
available BSW slot on the right side.
If all the BSW slots are equipped (7+1) the dedicated OCC card slot shall be used.

2.7 GE Multi-Link Protection Switching Operation


For Gigabit Ethernet (GE) multi-link operation, GE multi-link unit has the unique
function of multiple STM-1 operation to give high throughput and to maintain high
signal transmission quality. Protection switching function is activated for severe
propagation path condition (occurrence of multipath fading) and equipment failure.
Two cases are possible:
• Pure Ethernet link: M+0 GE Multi-Link operation in the absence of any TDM N+1
RPS operation. In this case, M = max 8.
• Hybrid TDM+Ethernet link: M+0 GE Multi-Link operation in the presence of TDM
N+1 RPS operation. In this case, M+N = max 8 and RF channel allocation shall be
done in such a way that N+1 TDM system is allocated among MSTU slots from 1
to N, whilst GE Multi- Link system is allocated from MSTU slot N+1 onwards.
In the provisional setting of “Edit RPS of RUC&RSC&RPS” on WebLT, Max Ch
should be set to N. That means that the N+1 TDM system is protected by standard
RPS (BSW+USW), whilst the GigaEthernet M+0 system is not protected by standard
BSW+USW RPS (OOS condition), but via adaptive load balancing making use of
USW switching criteria only and health check packets.
In case of N+1 RPS without OCC, it is possible to use GE ML ADPT OCC unit in the
OCC slot in order to add occasionally the protection channel of the TDM section as
av occasional VC-4 container for the GigaEthernet section, thus optimizing the
spectral efficiency by synergy between TDM and Ethernet sections transmitted. For
instance, take the hybrid operation of 3+1 SDH without OCC and 5+0 GE Multi-Link
operation implemented with 1xGE MLM, 1xGE MLS, 2xGE ML ADPT and 1xGE ML
ADPT OCC: all this configuration can be achieved by using just 8 MSTU’s in the
same rack; when the protection channel is occupied by other STM-1 channel on fade,
total GE Multi-Link capacity will drop down from 5xSTM-1 to 4xSTM-1 automatically
as per OCC functionality.
• In the M+0 GE Multi-Link operation, GE MLS unit has a switching control function
of switch-off and switch-back from M working channels independently N+1 RPS.
When any of working channel quality degrades below the threshold level, GE MLS
unit switch off the degraded working channel and after switch back again when the
quality becomes normal

FT42323EN02GLA2
96 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.8 Line Protection in BSW STM-1 Optical 1+1 DTI


Overview of 1+1 SFP Module Switching
Schematic block diagram of 1+1 SFP module switching is as follows;

Fig. 76

2.8.1 1+1 SFP Module Switching Criteria


Switching criteria of 1+1 SFP module switching is as follows;
• LOS (Loss of Signal)
• LOF (Loss of Frame)
• MS-AIS (Multiplex Section is being AIS)
• B2 ERR (B2 signal is being errors)

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
97
Hardware and Functionality

2.8.2 1+1 SFP Module Switching Mode


Switching mode is as follows;
• Manual Switching
• Automatic Switching
2.8.3 1+1 SFP Module Switching Time
Less than 50 ms with hit switch.

2.9 Line Protection in GE ML 1+1 DTI


1+1 SFP line protection in GE ML 1+1 DTI card set is managed by the L2-switch
embedded in the GE MLS card by means of STP protocol and eventually also Link
Aggregation enabled on the line side.
The GE ML card set can act as 1+1 DTI line protected or as 2xLAN GE via proper
SW setting. Also HW setting available to enable 1xLAN GE operation, 2xGE LAN
operation, 1+1 LAN GE line protected operation

FT42323EN02GLA2
98 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.10 Synchronization
2.10.1 MST Mode

Fig. 77 MST Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
99
Hardware and Functionality

2.10.1.1 Synchronization mode


SRT1F TCU has got two synchronization modes. In the following description,
Synchronous Source Unit (SSU) is defined as high quality reference clock source
equipment to generate and regenerate the primary/secondary clock signal of the
network in accordance with ITU-T Rec. G.813.
In the MODE 1, the system receives the reference clock source from other equipment
through the STM-1 signal input (LINE) or EXT CLK input connectors (EXT), and there
is not any reference signal output to SSU.
In the MODE 2, the clock selection is made in two separate steps, and involves
regeneration of the synchronization signal through the SSU (T4).

Fig. 78

FT42323EN02GLA2
100 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.10.1.2 Clock mode


TCU mode
On the down stream (from the primary station to the end station), the equipment
clock synchronizes to the signal incoming from the primary station. On the up stream
(from the end station to the primary station), the clock synchronizes to the signal
incoming from the primary station on the down stream.
THROUGH mode
On the down stream, the equipment clock synchronizes to the signal incoming from
primary station. On the up stream, the clock synchronizes to the signal incoming from
the end station.

Fig. 79

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
101
Hardware and Functionality

2.10.1.3 Quality Level (S1 byte)

2.10.2 RST Mode, (ONLY WITH SNMP/IP SV Unit)

Fig. 80 RST Mode

FT42323EN02GLA2
102 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.10.3 RS sub-module for enhanced RST mode


Since SW release 4.2.3, an enhanced type of RST mode is available for improved
performances also in critical synchronization environment,(Fig. 81) where the
synchronization network is not protected against synchronization failures. This new
type of RST mode (RST type 2) is configured by equipping the following optional sub-
module on the MCF/Controller card SNMP/IP:
SUB-MODULE FOR SV SNMP/IP IN RST MODE

SRT1 F-RS SRT1 F-RS

SRT1 F-RS SRT1 F-RS

SRT1 F-RS SRT1 F-RS

MUX: Digital multiplexer with/without SEC (equipment clock)


SRT1 F-RS: RS mode type2 setting on SRT1F WebLT without TCU
Clock signal between CLK1 and CLK2 is plesiochronous or
SRT1 F-RS SRT1 F-RS
asynchronous without external reference clock

SRT1 F-RS SRT1 F-RS

SRT1 F-RS SRT1 F-RS

Fig. 81 Example of critical synchronization environment

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
103
Hardware and Functionality

FT42323EN02GLA2
104 © 2010 Nokia Siemens Networks
Hardware and Functionality 

2.10.3.1 SUB-MODULE FOR SV SNMP/IP IN RST MODE Card Layout


The following picture shows the card layout of RS sub-module mounted on the MCF
Controller card (SV SNMP/IP). The controller card SNMP/IP can be single RPS or
double RPS.

Fig. 82 Enhanced RST Module

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
105
Hardware and Functionality

Summarizing, the synchronization mode for SRT1F with SNMP/IP controller can be:
Operation Mode for SRT1F Need of TSU Need of RS sub-
SNMP/IP module
MST YES NO
RST type 1 (typical) NO NO
RST type 2 (enhanced) NO YES

WARNING
To avoid misunderstanding, the following table is valid instead for SRT1F with
TL1/OSI controller:
Need of TSU Need of RS sub-
module

MST YES NOT APPLICABLE

2.10.3.2 Applicability
The applicability of RS sub-module has got some limitations:
• Applicable to controller cards SNMP/IP having dedicated card rev number only.
• Applicable to minimal configuration 2+1 or 2+0 with W1 and W2 slots equipped.
• Not applicable to TL1/OSI controller cards.
• Not applicable to 1+1, 1+0, nor 2+0 equipped as 1+1 with OCC card and disabled
RSC.

2.10.3.3 Functional Description of RST mode type 2


When RS sub-module is equipped and RS mode type 2 is selected via Web LT, basic
transmission functional signals such as DCCR, RSC, E1 are duplicated onto the
RFCOH 2Mbps Wayside channel, instead of usual STM-1 frame, and protected by
1:1 redundancy (RFCOH WS of W1 and W2 are used), thus providing better
robustness against synchronization impairments, than the standard RST mode type
1.
As a consequence:
• 2Mbps Wayside channels on the RFCOH are not available for user. Instead,
2Mbps Wayside channels over SOH are still available for customer use.
• Both RSC-X and RSC-Y (Radio Service Channel, main and protection) cannot be
selected via Web LT which STM-1 to use among P-W7, since its belonging STM-1
frame depends on the selected RFCOH wayside channel.

FT42323EN02GLA2
106 © 2010 Nokia Siemens Networks
Hardware and Functionality 

• E1 radio side cannot be selected via Web LT which STM-1 to use among P-W7,
since its belonging STM-1 frame depends on the selected RFCOH wayside
channel.
• E1 connection among co-located SRT1F terminals line side shall be done via
dedicated 4-wire connections using subD connectors available on backplane, and
cannot be done via tributary connection.
• DCCR connection among co-located SRT1F terminals line side shall be done via
dedicated connections using LAN connectors (Q-interface) available on
MCF/Controller unit, and cannot be done via tributary connection.

The following table summarizes the above mentioned limitations:

Operation Mode MST RST type 1 RST type 2


for SRT1F
SNMP/IP
Wayside SOH 1 per STM-1 1 per STM-1 1 per STM-1
Wayside RFCOH 1 per STM-1 1 per STM-1 NOT AVAILABLE
RSC-X Selectable P-W7 Selectable P-W7 Same as selected WS
RFCOH
RSC-Y Selectable P-W7 Selectable P-W7 Same as selected WS
RFCOH
E1 radio side Selectable P-W7 Selectable P-W7 Same as selected WS
RFCOH
E1 line side E1 or 4-wire E1 or 4-wire 4-wire
DCCR line side DCCR or LAN DCCR or LAN LAN cable
cable cable

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
107
Hardware and Functionality

FT42323EN02GLA2
108 © 2010 Nokia Siemens Networks
Hardware and Functionality 

3 LED INDICATION
3.1 SV Unit LED

Fig. 83 SV Units

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
109
Hardware and Functionality

Fig. 84 LED Indication of SV unit

FT42323EN02GLA2
110 © 2010 Nokia Siemens Networks
Hardware and Functionality 

3.2 Other Unit LED

Fig. 85

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
111
Hardware and Functionality

3.2.1 Optical Interface 1+1 DTI additional LED


The card is provided with SMT LED showing LOS, LOF, MS AIS and SEL (i.e. in
operation or not) indications for OPT-X and for OPT-Y signals:

Fig. 86 SMT LED

FT42323EN02GLA2
112 © 2010 Nokia Siemens Networks
Hardware and Functionality 

3.2.2 Aux/Lan converter LED


The card provides standard in-house ACT/MON RJ-45 LED’s for the LAN interface.
Further, it provides user LED for unit/line operational check from user:

Fig. 87

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
113
Hardware and Functionality

FT42323EN02GLA2
114 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4 Unit Settings
4.1 MSTU setting

Fig. 88

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
115
Hardware and Functionality

Fig. 89 Rotary switch details

FT42323EN02GLA2
116 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 90 Functions for MSTU Front Panel Controls

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
117
Hardware and Functionality

Fig. 91 Functions for Rotary Switch

FT42323EN02GLA2
118 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 92 Dade adjustment for space diversity equalization

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
119
Hardware and Functionality

4.2 SV TL1/OSI unit

Fig. 93

Fig. 94 SW41 on SV TL1/OSI unit front panel

FT42323EN02GLA2
120 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.3 SV SNMP/IP unit

Fig. 95

Fig. 96 BZ EN switch on SV SNMP/IP unit front panel

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
121
Hardware and Functionality

Fig. 97 HW switches on SV SNMP/IP unit side

FT42323EN02GLA2
122 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.4 TCU Unit

Fig. 98

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
123
Hardware and Functionality

4.5 BSW Electrical

Fig. 99

FT42323EN02GLA2
124 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.6 Occ Interface Electrical unit

Fig. 100

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
125
Hardware and Functionality

4.7 BSW Optical Unit

Fig. 101

Alarm Switches SW24, SW25, SW33 Setting

BSW Optical Control Function

Control Switch SW23 Setting


ALS Mode Switch SW22 Setting

Fig. 102 Default alarm output and tele-control configuration for optical BSW

FT42323EN02GLA2
126 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.7.1 Example of connection between optical interface and HK


management with external cable
Suppose to have a K-SHELF Single Terminal UP to 7+1 equipped with BSW w1
optical interface, in case we don't use the HK unit that directly transfer the Alarm and
cont to the backplane as house keeping alarm is necessary to realize the following
cable:

HK1 connector

PIN CN 19 PIN CN HK1


1 2
2 20
3 3
4 21
5 10 or 28
6 11
7 12
8 29 and 30

Fig. 103

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
127
Hardware and Functionality

4.8 BSW Optical Unit 1+1 DTI

Fig. 104 Switches setting

ALM1 (SW25), ALM2 (SW24) and ALM3 (SW13)


ALS (Automatic Laser Shutdown) mode (SW12)

Mask fake alarm for use of SFP without diagnostic monitoring (SW22-bit1)

CONT1 and CONT2 (SW23)

Type of Operation 1+0 or 1+1 DTI (SW22-bit2)

Fig. 105 Alarms and Controls configuration

FT42323EN02GLA2
128 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Definition for controls

Fig. 106

Note that the DTI SW item, is composed by two control bits, XY SEL and
MAINT/CONT, as indicated in the following table:

Fig. 107 DTI Control Bits

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
129
Hardware and Functionality

Definition for alarms/status

Fig. 108

Note that the XY SEL indication follows the following rule:

Fig. 109

FT42323EN02GLA2
130 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.9 BSW GE Interface

Fig. 110 Switches Setting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
131
Hardware and Functionality

Fig. 111 Alarms and Control Configuration

FT42323EN02GLA2
132 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.10 GE Multi Link (L2)

Fig. 112 Master Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
133
Hardware and Functionality

Fig. 113 Card Layout of GE ML Slave (L2-switch)

FT42323EN02GLA2
134 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 114 Card Layout of GE ML Adapter

For each GE ML unit, 8 alarms (ALM1, ALM2, ALM3, ALM4, ALM5, ALM6, ALM7 and
ALM8) and 4 controls (CONT1, CONT2, CONT3 and CONT4) are gathered via
backplane thanks to HK functionality. The function of some of these ALM and CONT
are fixed, whilst some of them can be configured by the HW switches present in the
GE ML Slave card. See also Appendix C and D and E for more details.

The following table shows the alarms available for GE MLM (Master) and GE MLS
(Slave).

The following table shows the remote controls available for GE MLM (Master) and
GE MLS (Slave).

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
135
Hardware and Functionality

The following HW setting table shows the full set of functionalities which can be set
via SMT DIP switches on the card and the relevant factory default value:

The following HW setting table shows the full set of functionalities which can be set
via rotary switches on the card and the relevant factory default value:

FT42323EN02GLA2
136 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.11 AUX/LAN Unit

Fig. 115 Unit Layout

The following four (4) operational modes are possible, settable via proper HW switch
SWA1 on the card:
• SWA1-bit1=ON: LAN 10/100BaseT to/from 64kbps user channel (standard F1
SOH byte or optional RFCOH RUC).
• SWA1-bit2=ON: LAN 10/100BaseT to/from 2x64kbps user channel (standard F1
SOH byte or optional RFCOH RUC) East/West Drop/Insert.
• SWA1-bit4=ON: LAN 10/100BaseT to/from 2Mbps wayside channel 120 Ohm
(standard SOH WS or standard RFCOH WS).
• SWA1-bit5=ON: LAN 10/100BaseT to/from 2x64kbps wayside channel 120 Ohm
(standard SOH WS or standard RFCOH WS) East/West Drop/Insert.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
137
Hardware and Functionality

4.12 OWBR Unit

Fig. 116 Unit Layout

FT42323EN02GLA2
138 © 2010 Nokia Siemens Networks
Hardware and Functionality 

The ATT switches on the card are used to modify the voltage attenuation for each
available input and output of E1 and E2 channels independently. The following table
shows the relation between the ATT switches name/position and the E1/E2
inputs/outputs.
For each ATT switch, the voltage attenuation can be chosen independently by acting
on the switch position of the 5 digit (1,2,4,8,16) block of ATT switch. The factory
default position of these digits is indicated on the card layout picture shown above,
which corresponds to 12 dB attenuation for each Input and 11 dB attenuation for
each Output (in/out resulting level: -4dBm).

Fig. 117 Switches Setting

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
139
Hardware and Functionality

4.13 RS Enhanced sub-module


The RS sub-module is equipped with HW switches, already set at 120 Ohm position
at factory (75 Ohm position is not available). The D-sub 25-pin connector allows the
interfacing towards the 120Ohm interface of the RFCOH
Wayside channels available on the backplane (see SRT1F manual UMN).

Fig. 118 RS Sub-Module switches

FT42323EN02GLA2
140 © 2010 Nokia Siemens Networks
Hardware and Functionality 

4.14 RUC SUB-Modules

Card Layout of VF sub-module

Card Layout of DGTL G.703 sub-module

Card Layout of V.11 sub-module

Fig. 119

The VF sub-module is equipped with HW switches for attenuation of level of input


and output signals. Factory default setting of these HW switches is chosen in such a
way to be fit for -4dBm input level and -4dBm output level.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
141
Hardware and Functionality

Fig. 120 HW switches setting and factory default for VF Input (ATT1S) and Output (ATT2S) level

The DGTL G.703 sub-module is equipped with 1 SMD HW switch for test (connect to
ground commands for RX clock, RX Data, TX Clock, TX Data).

FT42323EN02GLA2
142 © 2010 Nokia Siemens Networks
Hardware and Functionality 

HW switch specification on DGTL G.703 sub-module

Fig. 121

The V.11 sub-module is equipped with 1 SMD HW switch for synch specifications.
The bits 1-3 of this HW switch command the choice of relation between clock and
data, as per following picture.
The bits 2-4 of the same HW switch command the eventual inversion of the phase, if
needed in accordance with external equipment specifications.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
143
Hardware and Functionality

Fig. 122

FT42323EN02GLA2
144 © 2010 Nokia Siemens Networks
Hardware and Functionality 

5 Unit Replacement
WARNING
Unit replacement operations may affect the traffic transmission service.
The maintenance staff must inform these operations to the Central
Maintenance & Operation Center (CMOC) in advance.

Fig. 123 Unit Replacement Procedure and Availability of Hot Swap

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
145
Hardware and Functionality

5.1 MSTU and Other Units


5.1.1 MSTU
To replace an MSTU, the traffic should be switched over to the protection channel by
forcing the BSW in advance, and by cutting off power to the unit. The BSW operation
momentarily interrupts traffic.

5.1.2 OPT INTF of BBIU shelf


The traffic cannot be protected during the replacement work, unless the
line (facility) is protected by MSP (for OPT INTF - X/Y only).

5.1.3 Units in SCSU


Replacement of any unit other than that listed below may seriously affect traffic:
• TCU in stand-by (in case of card protection of TCU-X/Y).
• HK unit.
NOTE: System setting data for each unit is registered in the SV unit of SCSU.
When a unit is replaced with spares, the system setting data will be
automatically transferred from the SV unit. There is no setting change after unit
replacement.

FT42323EN02GLA2
146 © 2010 Nokia Siemens Networks
Hardware and Functionality 

5.2 SV TL1/OSI unit Replacement


System setting data for each unit is registered in the SV unit of SCSU.
The data is stored in the Inner Memory on the main PCB and also in the Backup
Memory on the sub-unit.
To replace the SV unit with a spare:
• Check that the RPS is in normal condition (no protection switch operation).
Change the Service State of RPS from In Service (IS) to Out of Service (OOS).
Provisioning
➩ Service State
➩ Change RPS State
➩ Group 1 or Group 2
➩ Delete
• Log off the LCT from the NE.
• Wait until when BACK UP LED of SV unit turns off (approx. 4 minutes)
• Cut off power supply to the SCSU and remove the SV unit.
• Remove the Back-up Memory sub-unit form the SV main PCB.
• Fit the Back-up Memory sub-unit on to the spare SV.
• Mount the spare SV on to the SCSU and turn on power supply to the SCSU.
• Wait until when ACS/SWDL LED of SV unit turns off (approx. 5 minutes)
• Log on the LCT to the NE.
• Check LED indications SRT 1F equipment and Alarm/status conditions on the
LCT.
Change the Service State of RPS from Out of Service (OOS) to In Service (IS).
Provisioning
➩ Service State
➩ Change RPS State
➩ Group 1 or Group 2
➩ Enter
• Check the RPS operations. If traffic interruption is not possible, check Manual
operation of USW. If the failure of SV unit is extended to the RPS total operation,
check all related functions.

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
147
Hardware and Functionality

5.3 SV SNMP Unit Replacement


The system setting data (provisioning setting data) is stored in the inner memory on
the main PCB, therefore the data should be registered to the spare SV unit. There
are two types of data uploading; one is by using application software 'HOTTOOL3,
the other is manual installation.
For detailed HOTTOOL3 information, please contact to NSN marketing staff.
To replace the SV unit with a spare:

5.3.1 In case of HOTTOOL3 software


• System setting data is downloading from failed SV unit to SRT1F WebLT that is
already installed the application software "HOTTOOL3". For details, refer to the
instruction manual of HOTTOOL3.
• Check the RPS is in normal condition (no protection switch operation).
• Check the ASC/SWDL LED being off (no one access the NE)
• Change the Service State of RPS from IS (In-Service) to OOS (Out-of- Service).
Provisioning
➩ Service State
➩ Enter RPS
➩ Select AID
➩ State: OOS
• Turn off the circuit breaker of "SV" on SCSU block and remove the failed SV unit.
• Set switch SW5600-bit2 and SW5602-bit2 on spare SV unit to ON (default value)
• Mount the spare SV unit on the SCSU block and turn on the circuit breaker "SV"
on the SCSU block.
• Wait a minute for SV unit startup.

FT42323EN02GLA2
148 © 2010 Nokia Siemens Networks
Hardware and Functionality 

• Set IP address of WebLT to 192.168.0.xx (xx: except 10) and set IP address of
spare SV unit to 192.168.0.10.
• Using "HOTTOOL3" software, system setting data is uploaded WebLT to spare SV
unit.
• Set operation IP address to the spare SV unit.
• Turn off the circuit breaker SV on SCSU block and remove the spare SV unit.
• Set switch SW5600-bit2 and SW5602-bit2 on spare SV unit to OFF (operation
mode)
• Set IP address of WebLT to normal state.
• Change the Service State of RPS from OOS to IS.
Provisioning
➩ Service State
➩ Enter RPS
➩ Select AID
➩ State: IS
• Check the RPS operations. If the failure of SV unit extended to the RPS total
operation, you must check all functions related.

5.3.2 In case of Manual Uploading


• Check the RPS is in normal condition (no protection switch operation).
• Check the ASC/SWDL LED being off (no one access the NE)
• Change the Service State of RPS from IS (In-Service) to OOS (Out-of- Service).

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
149
Hardware and Functionality

Provisioning
➩ Service State
➩ Enter RPS
➩ Select AID
➩ State: OOS
• Turn off the circuit breaker of "SV" on SCSU block and remove the failed SV unit.
• Set switch SW5600-bit2 and SW5602-bit2 on spare SV unit to ON (default value)
• Mount the spare SV unit on the SCSU block and turn on the non-fuse breaker "SV"
on the SCSU block.
• Wait a minute for SV unit startup.
• Set IP address of WebLT to 192.168.0.xx (xx: except 10) and set IP address of
spare SV unit to 192.168.0.10.
• Set SW5602-bit2 of spare SV unit to OFF
• Using provisioning setting table provided by the Contractor, each system setting
data is set manually one by one. For provisioning setting procedure, please refer
to the instruction manual of SRT1F WebLT.
• Set operation IP address to the spare SV unit.
• Turn off the circuit breaker of SV on SCSU block and remove the spare SV unit.
• Set switch SW5600-bit2 on spare SV unit to OFF (operation mode)
• Set IP address of WebLT to normal state.
• Change the Service State of RPS from OOS to IS.
Provisioning
➩ Service State
➩ Enter RPS
➩ Select AID
➩ State: IS
• Check the RPS operations. If the failure of SV unit extended to the RPS total
operation, you must check all functions related.

FT42323EN02GLA2
150 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 124 SW 5602,5600

Fig. 125 SW 5600

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
151
Hardware and Functionality

Fig. 126 INITIALIZING IP address of SV Unit

FT42323EN02GLA2
152 © 2010 Nokia Siemens Networks
Hardware and Functionality 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
153
Hardware and Functionality

FT42323EN02GLA2
154 © 2010 Nokia Siemens Networks
Hardware and Functionality 

6 Network management
6.1 TL1 SVProtocol Overview

Fig. 127

Fig. 128

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
155
Hardware and Functionality

Fig. 129

FT42323EN02GLA2
156 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 130

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
157
Hardware and Functionality

6.2 DCN Communication Protocol with TL1 SV


One SRT 1F Network Element has to be set as Gateway; all the others SRT 1F are
communicating via OSI protocol

Fig. 131

FT42323EN02GLA2
158 © 2010 Nokia Siemens Networks
Hardware and Functionality 

6.3 SV SNMP Unit Protocol overview


SRT 1F uses two (2) type of application layer protocol. HTTP on TCP/IP is used for a
web based connection between the built in web server and a client PC. SNMP on
UDP/IP is used for connection between the embedded SNMP agent and SNMP
managers.

Fig. 132

Two (2) types of connection, HTTP on TCP/IP and SNMP on UDP/IP same as
Ethernet LAN connection are also used on DCC connection carried by STM1 SOH.

Fig. 133

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
159
Hardware and Functionality

The LAN connection port on the equipment is designed based on IEEE


Recommendations.
The LAN port supports both connection speed of 10Base-T and 100Base-TX.
Connection speed is automatically detected and negotiated with a connected
equipment. For a physical cable connection to an external LAN equipment, straight
and cross cable can be use without care. SRT 1F automatically detects the plugged
cable type.

Fig. 134

FT42323EN02GLA2
160 © 2010 Nokia Siemens Networks
Hardware and Functionality 

6.4 DCN Communication Protocol with SNMP SV


All SRT 1F are communicating via SNMP/IP protocol; no limits to the number of NE
connected in chain.

Fig. 135

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
161
Hardware and Functionality

Fig. 136 New–SNMP SV inside TL1 network by Dual-Q Adapter

Fig. 137 New–SNMP SV inside TL1 network by LAN/AUX

FT42323EN02GLA2
162 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 138 NetViewer Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
163
Hardware and Functionality

FT42323EN02GLA2
164 © 2010 Nokia Siemens Networks
Hardware and Functionality 

7 Technical characteristics

Fig. 139

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
165
Hardware and Functionality

Fig. 140

FT42323EN02GLA2
166 © 2010 Nokia Siemens Networks
Hardware and Functionality 

Fig. 141

FT42323EN02GLA2
© 2010 Nokia Siemens Networks
167
Hardware and Functionality

Fig. 142

NOTE: for further information please see UMN

FT42323EN02GLA2
168 © 2010 Nokia Siemens Networks