Sei sulla pagina 1di 2

1) HYDRAULIC PARTICULARS OF RAYEES MAIN CANAL

S. NO Description Particulars
1 MFL DISCHARGE IN CUMCES 148.270 Cumecs
2 BED WIDTH IN MTS 45.300 m
3 BED LEVEL 11.880 m
4 BED FALL 1 in 7388
5 SURFACE FALL 1 in 7388
6 O.F.L 3.162 m
7 Max. Flood Level (M.F.L) 15.190 m
8 Tof of Bank Level (T.B.L) 16.100 m
9 VELOCITY 0.948 m/s
10 SIDE SLOPES 1.5 :1
11 FREE BOARD 0.910 m
12 N VALUE 0.025
13 Proposed Road Level 19.265 m
14 Existing Road Level 18.650 m
2) AFFLUX CALCULATION

Data
Discharge, Q = 148.270 cumec
MFL = 15.190 m
Bed Level = 11.880 m
Side Slopes = 1.5 :1
Increased Bed Width at
= 61.00 m
bed level
No of piers = 8
Size of pier = 1.00 m dia.

Afflux Calculation
Average Depth, d = 3.310 m
Bed Width at MFL = 70.930 m
Average Width, b = 65.965 m
Area before constriction
An1 = 218.344 sqm
Average velocity prior to constriction
Vn1 = Q/An1
= 0.68 m/s

Area after construction


An2 = An1 - no's of piers * average width of piers * average depth (d)
= 191.864 sq m
Average Velocity after construction
Vn2 = Q/An2
= 0.773 m/s
Afflux due to constriction (By Molesworth Formula)
h = [(Vn1^2)/17.88+0.015] [ (An1/An2)^2-1]
= 0.012 m < 0.05 m (5 cm)