Sei sulla pagina 1di 26

Universidad Autónoma De Santo Domingo

Estudiante: Esteven Leonardo Peña De Leon

Matricula: 100263578

Tema: Proyecto Final

Materia: Acueductos y alcantarillados

Profesor: Ing. José Infante

Fecha de entrega: 14/06/2017

Semestre: 2017-10

pág. 1
Contenido
Introducción.................................................................................................................................2
Red de distribución de agua potable.............................................................................................3
Memoria descriptiva.....................................................................................................................4
¿Qué es una red de distribución de agua potable?....................................................................4
Tipos de redes..........................................................................................................................4
Datos suministrados del residencial.........................................................................................4
Memoria de calculo......................................................................................................................5
Calculo del Qdis y Qu..............................................................................................................5
Demanda por nudo...................................................................................................................7
Criterios de diseño....................................................................................................................7
Cálculos de Epanet...................................................................................................................8
Red de recolección de agua residual...........................................................................................10
Memoria descriptiva...................................................................................................................11
Definición Alcantarillado Sanitario........................................................................................11
Caudales de diseño de aguas residuales..................................................................................12
Memoria de calculo....................................................................................................................12
Calculo del Qdis y Qu............................................................................................................12
Cálculos y criterios de diseño.................................................................................................13
Planimetría y perfiles del alcantarillado Sanitario..................................................................16
Red de recolección de aguas pluviales.......................................................................................17
Memoria descriptiva...................................................................................................................18
Definición alcantarillado pluvial............................................................................................18
Memoria de cálculos..................................................................................................................20
Método racional.....................................................................................................................20
Capacidad de conducción de las cunetas por Manning...........................................................21
Introducción

2|Página
Red de distribución de agua potable

3|Página
Memoria descriptiva
¿Qué es una red de distribución de agua potable?
Una Red de Distribución de Agua Potable es el conjunto de tuberías
trabajando a presión, que se instalan en las comunidades a partir de las
cuales serán abastecidas las diferentes parcelas o edificaciones de un
desarrollo.
Tipos de redes
Redes abiertas
Este tipo de red de distribución se caracteriza por contar con una tubería
Principal de distribución (la de mayor diámetro) desde la cual parten
ramales que terminarán en puntos ciegos, es decir sin interconexiones con
otras tuberías en la misma Red de Distribución de Agua Potable.
Redes cerradas
En este tipo de red, se logra la conformación de mallas o circuitos a través
de la interconexión entre los ramales de la Red de Distribución de Agua
Potable.

Datos suministrados del residencial

4|Página
Memoria de calculo

Tomando en cuenta el esquema de la red proporcionada, podemos obtener


los siguientes datos: Longitudes, Cotas, Nudo.
Debido a que esta red es una red cerrada, no podemos utilizar el método de
la piezometrica, pero si podemos obtener la demanda por nudo mediante el
caudal unitario.

Calculo del Qdis y Qu


El calcular el caudal unitario se obtiene mediante la siguiente expresión:

Qdis
qu= ¿
∑ longitud de la¿
Esta sumatoria no incluye la Línea Matriz.

Datos Resultados
Habitantes 6493 Población
Dotación(lt/hab/día) 280 urbana

Q promedio Hab∗¿˙
¿¿ ¿
86400
Q promedio(Lt/seg) 21.04212963
Población
Q m diario(Lt/seg) =Cvd* Q promedio Cvd=1.25 urbana
Q m diario(Lt/seg) 26.30266204
Población
Q max horario(Lt/seg) =Cvh* Q promedio Chv=2.00 urbana
Q max horario(Lt/seg) 42.08425926
Q inc(Lt/seg) 10
Qdis(Lt/seg) 42.08425926
Qu 0.024459487

El caudal de diseño total de la red, (Q Dis) lo será el mayor entre:

El Q Máx. Horario
El Q Máx. Diario + el Q Inc.

5|Página
Luego con el Qu se calcula obtiene el caudal de salida
Q=qu x longitud de tramo

Caudal de
Tramos Long Cota A Cota B
salida
De A m m m LPS
14 4 210.80 58.24 52.61
4 3 109.45 52.61 51.89 2.68
3 2 84.32 51.89 52.92 2.06
2 1 105.40 52.92 52.00 2.58
1 5 92.75 52.00 51.28 2.27
5 10 122.58 51.28 50.56 3.00
4 8 92.75 52.61 51.99 2.27
8 13 122.58 51.99 51.07 3.00
13 12 109.45 51.07 50.62 2.68
12 11 84.32 50.62 50.24 2.06
11 10 105.40 50.24 50.56 2.58
7 3 92.75 52.90 51.89 2.27
7 8 109.45 52.90 51.99 2.68
7 6 84.32 52.90 52.30 2.06
2 6 92.75 52.92 52.30 2.27
6 11 122.58 52.30 50.24 3.00
6 5 105.40 52.30 51.28 2.58
10 9 84.32 50.56 50.21 2.06

Demanda por nudo


Debido a que en un nudo de una red cerrada se tendrán más de una entrada
se han de sumar las caudales que llegan a este.

Nudo Demanda

6|Página
LPS
1 2.58
2 2.06
3 2.68
5 4.85
6 4.33
7 4.95
8 2.27
9 2.06
10 5.58
11 5.06
12 2.68
13 3.00
4 0.00

Los caudales por tramo en redes cerradas se calculan con el método de


Cross, pero para mayor comodidad se utilizó el programa Epanet para este
cálculo.

Criterios de diseño
El diámetro mínimo a ser utilizado es 3”, antiguamente se admitía 2”

Los diámetros disminuyen en la dirección del flujo.

La cota de fondo del tanque de regulación será la cota y Piezométrica


inicial y corresponderá a la línea estática del sistema, representando la
energía disponible total del sistema. Por tal motivo, el tanque de regulación
estará ubicado en una cota más alta que cualquier otro punto de la red, para
garantizar que el agua puede llegar hasta a todo punto. Esa cota será
también lo suficientemente alta, como para garantizar una presión mínima
en toda la red. Si no existe un punto en toda el área, que pueda garantizar
esa presión mínima, será necesario elevar el tanque a una cota que si la
garantice.

La presión mínima en toda la red será de 10 MCA (Metros de Columna de


Agua), 1.00 kg/cm2 o 14 Lbs/ Pulgs 2 la máxima suele ser entre 50 o 70
MCA, CAASD por ejemplo la limita a 50.
La Piezometrica inicial es la cota de fondo del tanque. La Piezometrica al
final de un tramo será la Piezometrica en el punto inicial del tramo menos
las pérdidas en ese tramo. Se asumirán las pérdidas del tramo como el

7|Página
producto J x L. La presión en un punto, será la Piezometrica del punto
menos su cota.
La suma de caudales de entrada a un nudo es igual a la suma de los
caudales de salida del mismo nudo.

Cálculos de Epanet

8|Página
Red de recolección de agua residual

9|Página
Memoria descriptiva
Definición Alcantarillado Sanitario
Denominamos Alcantarillado Sanitario al sistema de estructuras y tuberías
usado para la recogida y transporte de las aguas residuales y de una
población desde el lugar en que se generan hasta el sitio en que se vierten al
medio natural pasando por algún mecanismo de depuración, para hacerla
menos agresiva al cuerpo receptor en que sean vertidas. Parte de una
Acometida o Conexión del Alcantarillado Sanitario, que es un conjunto de
tuberías y accesorios que permiten la descarga de Agua Residual desde las
instalaciones internas del usuario hacia la red de alcantarillado,
concluyendo en un colector principal, que es el encargado de llevar las
aguas al tratamiento, a partir del cual se incorporan a un medio líquido
natural denominado cuerpo receptor, que puede ser el mar, un río, un lago e
incluso las aguas subterráneas, a las que se puede incorporar el agua
residual mediante filtrantes.
En las zonas densamente pobladas es necesario recolectar y remover las
diferentes clases de agua y aguas residuales provenientes de todo lugar

10 | P á g i n a
habitado, Además de cumplir con una necesidad sanitaria e higiénica, este
proceso contribuye a mantener una calidad de vida adecuada.
Un aspecto importante es que el agua recolectada no sólo debe ser
descargada hacia cualquier lugar, sino que además ha de ser purificada.
La recolección, disposición y tratamiento de las aguas residuales
representan un factor de costo que no responde a beneficios a corto
plazo. Es comprensible que, en los países en desarrollo, el drenaje y
tratamiento de las aguas residuales resulten poco económicos y sólo
puedan realizarse a un costo razonablemente bajo. Sin embargo, la
disposición de aguas residuales es una condición previa para
satisfacer las necesidades más elementales de una población y dar
paso a la industrialización.
Tanto las aguas residuales como las aguas pluvia les deben ser evacuadas
de las áreas pavimentadas.

Caudales de diseño de aguas residuales


Los Caudales de diseño tienen por origen
Residual doméstico: Originado por las descargas de las viviendas,
industrias y diversos usos del agua servida como potable. Se estima como
un porcentaje del caudal servido.
Infiltración Pluvial: Originado por la influencia de la lluvia sobre el
alcantarillado.

Se estima como un porcentaje del caudal servido como agua potable. El


caudal de diseño se basa en el caudal medio diario servido afectado por un
factor menor a la unidad (0.80 valor típico). Se diseña para la población al
final del período de diseño. El caudal máximo horario o caudal pico, será el
resultante anterior por un coeficiente, que depende de los usuarios del
servicio.
El porcentaje depende de diversos factores: Desperdicios en la red externa
e interna del servicio de abastecimiento de agua potable. Uso del agua para
11 | P á g i n a
riego de jardines o de cultivos. Evaporación, Uso de agua para piscinas.
Uso y disposición inadecuada del agua. Zona en la que se ubique la
edificación (Urbana, Semiurbana o Rural).

Memoria de calculo
Calculo del Qdis y Qu
Se procede a determinar el caudal de diseño para aguas residuales.
Qmedio de diseño = QR = (Pob * Dot* CR)/ 86400

Donde CR= Coeficiente de Retorno


CR = 0.5 Rurales
0.8 Promedio
0.9 a 0.95 Zonas urbanas densamente pobladas

Qmax horario = CH * QR, donde CH= coeficiente de Hartmon

CH = 1+ 14/(4+ √P) P es la población expresada en miles.

El Q de diseño de la red, será el Qmax horario de diseño determinado


como:

Q Dis. = Qinfiltración + Qmax horario

Tasas usuales de Infiltración:


10,000-----80,000Lts/Dia/Km
500---------1,000Lts/Dia/Registro
Q infiltración= (Long red (en KM) * Tasa + No. Reg*Tasa )/86400

Datos Resultados
Habitantes 6493
Dotación(lt/hab/día) 280 Población urbana
Coeficiente de retorno(Cr) 0.8
Qmed(Lt/Seg) DotxHabxCr/86400
Qmed(Lt/Seg) 16.8337037
Coeficiente de 1+14/(4+P^1/2)

12 | P á g i n a
Hartmon(CH)
Coeficiente de
Hartmon(CH) 3.138012829
Qdom(Lt/Seg) 52.82437818
LrxTasared +
Q Infiltración(Lt/Seg) No.RegxTasareg/86400
Long. Red(m) 1931.3701 Longitud de Red Completa
Long. Red(km) 1.9313701
Tasa Long.(Lt/Día/Km) 30000
No. De Registros 25
Tasa Reg.(Lt/Dia/Reg) 1000
Q Infiltración(Lt/Seg) 0.95996647
Qdis(Lt/Seg) 53.78434465
qu Qdis/Σlongred Long interna
Σlongred(m) 1720.57
qu 0.031259609

Cálculos y criterios de diseño


Se aplicará la teoría del caudal unitario (Qtramo=qu *L), se enumeran los
registros y se diseña por tramos. Los alcantarillados sanitarios se diseñan
por gravedad en la medida de lo posible, y se seleccionará un punto bajo de
bombeo donde no sea posible.

Diseñar un tramo de una red de alcantarillado sanitario es determinar una


pendiente (m) que para el diámetro seleccionado conduzca una caudal (Q)
mayor al de diseño del tramo. Es favorable que la pendiente de la tubería
tenga el mismo signo que la de la superficie sobre ella (calle, suelo entre
otras): s= (Cotaf - Cotai)/L

Se escogerá una pendiente que provoque velocidades que estén dentro de


los siguientes intervalos:

Hormigón

0.6 ≤ vel≤ 3.0 mts/seg

Q = A(R2/3)(S1/2)/n , de donde n = 0.013 para el hormigón y 0.0095 para


el PVC.

En todo registro puede haber varias entradas, pero solo una salida. A los
registros iníciales se les llama registro en cabeza o cabezal y se demarcan
con una tilde.

13 | P á g i n a
Cota A Cota B Diferencia de Cota A2 Cota B3 Pendiente Max Q Velocidad a
sante(mts)Rasante(mts) Rasante Tuberia(mts) Tuberia(mts) Tuberia(m/m) Conducido(L/S) Tubo lleno(m/seg)
52.9 51.89 1.01 51.5 50.49 0.010889488 35.70591271 1.101039375
52.61 52.25 0.36 51.21 50.85 0.006578346 27.75203128 0.855770847
52.25 51.89 0.36 50.83 50.49 0.006212883 26.97012657 0.831659774

14 | P á g i n a
51.89 52.92 -1.03 50.47 50.141152 0.0039 21.36823812 0.658918083
52.92 52.46 0.46 50.121152 49.915622 0.0039 21.36823812 0.658918083
52.46 52 0.46 49.895622 49.690092 0.0039 21.36823812 0.658918083
52 51.28 0.72 49.670092 49.308367 0.0039 21.36823812 0.658918083
52.9 52.3 0.6 51.5 50.9 0.00711575 28.86335011 0.890039844 mínimo 8“ o 0.20 Mt.
52.92 52.3 0.62 51.52 50.9 0.006684636 27.97533506 0.862656717
52.3 51.79 0.51 50.88 50.39 0.009297913 32.99355735 1.017400285
51.79 51.28 0.51 50.37 49.88 0.009297913 32.99355735 1.017400285
51.28 50.92 0.36 49.208367 49.049013 0.0026 51.43985976 0.70498515
50.92 50.56 0.36 49.029013 48.869659 0.0026 51.43985976 0.70498515

varias entradas, pero una sola salida.


52.3 51.27 1.03 50.9 49.87 0.016805352 44.35680053 1.367801023
51.27 50.24 1.03 49.85 48.84 0.016479034 43.92404091 1.354456304
52.61 51.99 0.62 51.21 50.59 0.006684636 27.97533506 0.862656717
52.9 52.445 0.455 51.5 51.045 0.008314299 31.19961424 0.96208166
52.445 51.99 0.455 51.025 50.59 0.007948835 30.5062029 0.940699398
51.99 51.53 0.46 50.57 50.13 0.007178985 28.9913166 0.893985861
51.53 51.07 0.46 50.11 49.67 0.007178985 28.9913166 0.893985861
51.07 50.845 0.225 49.65 49.4365725 0.0039 21.36823812 0.658918083
50.845 50.62 0.225 49.4165725 49.203145 0.0039 21.36823812 0.658918083
50.62 50.24 0.38 49.183145 48.84 0.004069556 21.82779919 0.67308926
50.24 50.4 -0.16 48.74 48.60298 0.0026 51.43985976 0.70498515
50.4 50.56 -0.16 48.58298 48.44596 0.0026 51.43985976 0.70498515
limpiar la tubería. El registro se coloca al inicio de un tramo en cada
La red se divide en intersecciones de las vías, cambios de dirección o

flujo del agua en la tubería y también es utilizado para inspeccionar y

50.56 50.21 0.35 48.34596 48.17732 0.002 97.16236204 0.749032711


La profundidad mínima a la cual se colocará la tubería es 1.20mts + el
diámetro interior o de diseño de la tubería, la profundidad de la zanja o

de la red es de 8”. Antiguamente era de 6”. Por esto la primera cota del
excavación será de por lo menos 1.50mts que incluyen 0.10 mts de una

Dom., esa distancia es usualmente 100 mts). A todo registro inicial se le

49.72 49.72 0 48.15732 48.0167866 0.002 97.16236204 0.749032711


cambio de dirección, y cuando la longitud supera un cierto valor (en Rep.
Los registros según la altura de las tuberías que a él llegan condicionan el
Esto es restamos la profundidad mínima de colocación 1.20 + el diámetro

llama registro en cabeza. Por norma de diseño, en un registro puede haber


registros, a los que se llama nudos. Cada tramo es limitado por dos nudos.

49.72 49.22 0.5 47.9967866 47.8562532 0.002 97.16236204 0.749032711


primer registro, siempre en cabeza será la cota del terreno menos 1.40 Mts.
capa de arena en la cual se recostará el tubo. El diámetro mínimo de diseño

49.22 48.73 0.49 47.8362532 47.6957198 0.002 97.16236204 0.749032711


Tramo De Red Longitud D Pendiente Minima Caudal acumu
De A (mts) (Pulg) (m/m) (L/S)
7 3 92.75 8 0.0039 2.89932869
4 16 54.725 8 0.0039 1.71068207
16 3 54.725 8 0.0039 3.42136415

15 | P á g i n a
3 2 84.32 8 0.0039 8.95650303
2 15 52.7 8 0.0039 10.6038844
15 1 52.7 8 0.0039 12.2512657
1 5 92.75 8 0.0039 15.1505944
7 6 84.32 8 0.0039 2.63581019
2 6 92.75 8 0.0039 2.89932869
6 17 52.7 8 0.0039 7.18252025
17 5 52.7 8 0.0039 8.82990162
5 19 61.29 12 0.0026 25.8963974
19 10 61.29 12 0.0026 27.812298
6 20 61.29 8 0.0039 1.91590140
20 11 61.29 8 0.0039 3.83180281
4 8 92.75 8 0.0039 2.89932869
7 18 54.725 8 0.0039 1.71068207
18 8 54.725 8 0.0039 3.42136415
8 21 61.29 8 0.0039 8.23659425
21 13 61.29 8 0.0039 10.1524956
13 25 54.725 8 0.0039 11.8631777
25 12 54.725 8 0.0039 13.5738598
12 11 84.32 8 0.0039 16.2096
11 24 52.7 12 0.0026 21.6888541
24 10 52.7 12 0.0026 23.3362355
10 9 84.32 16 0.002 53.7843446
9 23 70.2667 16 0.002 53.7843446
23 22 70.2667 16 0.002 53.7843446
22 PTAR 70.2667 16 0.002 53.7843446
Planimetría y perfiles
del alcantarillado
Sanitario

16 | P á g i n a
Red de recolección de aguas pluviales

17 | P á g i n a
Memoria descriptiva

Definición alcantarillado pluvial


Denominamos Alcantarillado Pluvial al sistema de estructuras y tuberías
usado para la recogida y transporte de las aguas pluviales de una población
desde el lugar en que se generan hasta el sitio en que se vierten al medio
natural.
Objetivos del Drenaje Pluvial:
Disminuir al máximo los daños que las aguas de lluvia pueden ocasionar a
la ciudadanía y las edificaciones en el entorno urbano.

Garantizar el normal desenvolvimiento de la vida diaria en las ciudades,


permitiendo así un apropiado tráfico de personas y vehículos durante la
ocurrencia de las lluvias.

La información necesaria para los estudios preliminares depende de la


complejidad y extensión de los mismos, es por ello que sólo pueden darse
algunas pautas relativas a los niveles de información más relevantes, las
cuales en la mayoría de los casos son también requeridas generalmente por
otras disciplinas que intervienen en los estudios como son:

• Topografía.

• Hidrología.

• Geología.

Se requiere estudiar, además:

• Drenajes existentes.

• Zonas posibles inundaciones

18 | P á g i n a
Una vez escogida la solución óptima del drenaje urbano, se procede a
plantear varios trazados tentativos con el objetivo de definir una de las
variantes a nivel del anteproyecto.

Las aguas pluviales provenientes de los techos de las viviendas,


edificaciones y las áreas verdes que componen la urbanización serán
recogidas por las cunetas (contenes) y luego pasaran a los imbornales,
para ser colectadas por la red principal, la cual las conducirá hasta la
cañada ubicada en la parte sur de la urbanización.

Las cunetas son el primer receptor de diseño de un Alcantarillado Pluvial.


El caudal que recibe cada cuneta será el de su área adyacente, más la que
puedan aportarle otras cunetas, de la misma manzana o bien de otra a través
de un Badén.
El caudal que es capaz de conducir una cuneta se determina por la
expresión de Manning. Las intersecciones de las vías se convierten en los
nudos de diseño y se denominan por números. Un tramo está limitado por
dos nudos. La pendiente de un tramo de una vía, la rugosidad que le
asignemos y su sección hidráulica, nos permitirán determinar el caudal que
es capaz de conducir.

El sistema de drenaje pluvial se compone de las siguientes unidades:


 Cuneta: Unidad receptora y colector abierto inicial.

 Baden: Traspaso del agua a la siguiente área (Cuadra o


manzana).

 Imbornal: Unidad receptora. En nuestro proyecto los imbornales


tendrán cámaras derivadoras hacia el colector pluvial.

 Registros: Los registros son puntos donde se inspecciona el flujo


del agua en la tubería y también es utilizado para limpiar la
tubería. Los registros se colocan en las intersecciones o cambios
de dirección, así cada tramo es limitado por dos registros.

 Conductos abiertos o cerrados: Colectores.

19 | P á g i n a
 Cabezal de descarga: Obra de arte ubicada al final de la tubería
colectora, usualmente de hormigón.

Memoria de cálculos
El diseño de un Drenaje Pluvial, se hace basado en la fórmula racional,
para los caudales de escorrentía y de la de Manning, para la capacidad de
conducción de los conductos utilizados.
Método racional

Fórmula Racional, el caudal debido a la lluvia en un punto de una cuenca


será:

• Q = C.I.A

• C = Coeficiente de Escorrentía.

• I = Intensidad de Lluvia.

• A = Área drenada.

Para los diseños de sistemas de Drenaje Pluvial, el valor mínimo del tiempo
de duración de la lluvia es de 5 minutos y su valor máximo es de 120
minutos. Para azoteas y columnas de drenaje pluvial se recomienda un
valor de 5 minutos. - El área drenada se obtiene de los planos topográficos
y se refiere a la superficie del área o cuenca tributaria. Para el cálculo de
las áreas de aportes nos auxiliaremos de las figuras geométricas
(Triángulos y Trapecios).

20 | P á g i n a
Un buen valor de I que puede ser usada en casi todo el país es 100
mms./Hora.
Un coeficiente de escorrentía típico en ciudades puede ser 0.80.
De donde se desprende que: Q = A * 100 * 0.80 /3600 = 0.022Q
Donde A en Mts.2 Cuadrados, el resultado en Lts./Seg.

Capacidad de conducción de las cunetas por Manning

Para nuestro proyecto se utilizará la siguiente sección típica de cuneta

0.16

Fig.1

Q= (A/N) RH⅔ S½
A=(3*0.16)/2=0.24 m2
Hip=3.00426 m
P=hip+0.16=3.16 m
2
R h 3 =(A/P)^2/3=0.179342

N=0.013
Q= 3310√ S
Criterios de diseño para alcantarillado pluvial

21 | P á g i n a
Definir o limitar el tramo. Indicamos las cotas del tramo, anterior y
posterior.

La diferencia de altura entre dos rasantes de una calle inicial y final entre la
longitud del tramo determina la pendiente. Para una cuneta con su sección
y pendiente puede determinarse su capacidad de conducción que siempre
debe ser igual o mayor al caudal aportado por la lluvia.

Para un colector la dirección del flujo; puede ser a favor o en contra de la


pendiente de un tramo de calle. Es recomendable que la pendiente de la
tubería sea del mismo signo de la pendiente de la calle, sin embargo, habrá
casos excepcionales, en los que el agua deberá dirigirse en
“contrapendiente”, para poder sacar el agua en puntos bajos entre puntos
altos, que en las ciudades se denominan “puntos muertos”.

El caudal aportado se determinará por el área de aporte, que se asocia a


figuras geométricas triangulares, trapezoidales o romboideas y será
determinado por la fórmula racional.

Se procede a seleccionar un diámetro apropiado; el primero será al menos


de 15 ” por norma.

Diseñar un tramo es determinar una pendiente que nos proporcione a tubo


lleno una velocidad mayor que la mínima, y menor que la máxima, que
para el diámetro seleccionado conduzca un caudal mayor al caudal
aportado por la lluvia. Ese caudal puede ser del área subyacente. Si recibe
aportes desde otras áreas, calles o badenes se le sumará al subyacente.

Datos Físicos:
La menor diferencia de entrada
La menor diferencia de entrada y salida de un registro es de 2cm
(diferencia mínima).
La mayor diferencia de entrada y salida de un registro es de 1 Mt.
(diferencia máxima para evitar erosión del fondo).

22 | P á g i n a
Si hay un cambio de diámetro, la diferencia entre la entrada y la salida, es
igual a la diferencia de los diámetros.
La profundidad mínima a la que se debe colocar la tubería con respecto al
suelo es de 1.20 m sin incluir el diámetro.
Las velocidades que se toman son las siguientes:
Vmín = 0.6 mts/seg En Hormigón
Vmáx = 3.0 mts/seg En Hormigón
Capacidad
Longitud Cota A Cota B Pendiente Area Aporte Caudal Aporte
Tramo Lado conduccion
De A (Mts) (Mts) (Mts) (M/M) M^2 (L/S) Cuneta (L/S)
7 3 Este 92.75 52.9 51.89 0.0108895 1704.55 37.5001 345.40747
Estos
7 3 Oeste 92.75 52.9 51.89 0.0108895 1704.59 37.50098 345.40747 tramos
4 3 Norte 109.45 52.61 51.89 0.0065783 3883.5 85.437 268.46419 llegan a un
Tabla de capacidad de las cunetas punto
4 3 Sur 109.45 52.61 51.89 0.0065783 2388.98 52.55756 268.46419 muerto en
3, Colocar
2 3 Norte 84.32 52.92 51.89 0.0122154 2529.6 55.6512 365.83168 imbornal y
colector
2 3 Sur 84.32 52.92 51.89 0.0122154 1373.16 30.20952 365.83168
7 8 Norte 109.45 52.9 51.99 0.0083143 2388.98 52.55756 301.81499 Colocar
7 8 Sur 109.45 52.9 51.99 0.0083143 4291.54 94.41388 301.81499 imbornales
y colector
4 8 Este 92.75 52.61 51.99 0.0066846 3382.48 74.41456 270.62436
en 13 y
4 8 Oeste 92.75 52.61 51.99 0.0066846 1704.55 37.5001 270.62436 agregarse a
8 13 Este 122.58 51.99 51.07 0.0075053 3968.56 161.72288 286.75573 la tuberia
8 13 Oeste 122.58 51.99 51.07 0.0075053 3161.24 254.01882 286.75573 de 3
7 6 Norte 84.32 52.9 52.3 0.0071157 1373.16 30.20952 279.21473
7 6 Sur 84.32 52.9 52.3 0.0071157 2876.98 63.29356 279.21473
2 6 Este 92.75 52.92 52.3 0.0066846 1704.59 37.50098 270.62436 Estos
2 6 Oeste 92.75 52.92 52.3 0.0066846 1704.54 37.49988 270.62436 caudales
6 11 Este 122.58 52.3 50.24 0.0168054 3161.24 200.55134 429.09336 llegan al
6 11 Oeste 122.58 52.3 50.24 0.0168054 3087.45 105.42378 429.09336 punto 11,
13 12 Norte 109.45 51.07 50.62 0.0041115 4291.55 94.4141 212.23958 colocar
13 12 Sur 109.45 51.07 50.62 0.0041115 588.41 12.94502 212.23958 imbornal y
12 11 Norte 84.32 50.62 50.24 0.0045066 2876.98 157.70766 222.20534 colector
12 11 Sur 84.32 50.62 50.24 0.0045066 421.6 22.22022 222.20534
10 11 Norte 105.4 50.56 50.24 0.0030361 2267.97 49.89534 182.3823
10 11 Sur 105.4 50.56 50.24 0.0030361 527 11.594 182.3823
2 1 Norte 105.4 52.92 52 0.0087287 3762 82.764 309.24423
2 1 Sur 105.4 52.92 52 0.0087287 2227.96 49.01512 309.24423 Colocar
1 5 Este 92.75 52 51.28 0.0077628 1704.54 86.515 291.63341 imbonal y
1 5 Oeste 92.75 52 51.28 0.0077628 3382.48 157.17856 291.63341 colector en
5 10 Este 122.58 51.28 50.56 0.0058737 3087.45 154.4389 253.67895 el punto 5
5 10 Oeste 122.58 51.28 50.56 0.0058737 3073.74 224.80084 253.67895
Colocar
imbornal y
10 9 Norte 84.32 50.56 50.21 0.0041509 2915.31 64.13682 213.25377 colector en
el Cul de
10 9 Sur 84.32 50.56 50.21 0.0041509 661.91 14.56202 213.25377 Sac
Colocar
imbornal en
236| P á g i n5 aNorte 5 porque el
105.4 52.3 51.28 0.0096774 2227.96 49.01512 325.61753
tramo 5-10
no aguanta
este caudal
6 5 Sur 105.4 52.3 51.28 0.0096774 2267.96 49.89512 325.61753 aportado
24 | P á g i n a
las tuberias
Pendiente Pendiente
Cota A Cota B D Cota ATuberia Cota B Tuberia Pendiente Q. Max Conducido Caudal Conducido Velocidad Tubo lleno
terreno Minima
(Mts) (Mts) (M/M) (pulg) (Mts) (Mts) (M/M) (M/M) (LPS) (LPS) (M/Seg)
51.89 52.61 -0.006578 27 50.0042 49.82908 0.0012 0.0016 350.7732567 298.85636 0.949602025
52.61 51.99 0.0066846 27 49.80908 49.66068 0.0012 0.0016 350.7732567 298.85636 0.949602025
51.99 51.53 0.0075053 27 49.64068 49.542616 0.0012 0.0016 350.7732567 298.85636 0.949602025
51.53 51.07 0.0075053 27 49.522616 49.424552 0.0012 0.0016 350.7732567 298.85636 0.949602025
51.07 49 0.0414 27 49.404552 49 0.0012 0.008091 788.803189 714.59806 2.135422502
50.24 49 0.0248 33 48.34 48.26 0.001 0.0016 599.000167 547.39234 1.085529797
51.28 50.92 0.0058737 21 49.18 48.99613 0.0015 0.003 245.7396257 98.91024 1.099712821
50.92 50.56 0.0058737 21 48.97613 48.79226 0.0015 0.003 245.7396257 98.91024 1.099712821
50.56 50.21 0.0041509 33 48.49226 48.348916 0.001 0.0017 617.4352396 478.14998 1.118938503
50.21 49 0.0242 33 48.198916 48.113916 0.001 0.0017 617.4352396 556.84882 1.118938503
25 | P á g i n a
Tabla de capacid
Longit
Tramo

pluvial
De A (Mts
3 4 10
4 8 9
8 16 6
16 13 6
13 Arroyo
11 Arroyo
5 15 6
15 10 6
10 9 8
9 Arroyo

del alcantarillado