Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Zelio Electromechanical
Relays
Interface, miniature and power
electromechanical relays
schneider-electric.com
Harmony
Discover Harmony
Advanced operator interface and industrial relays
Harmony operator interface and industrial relays enhance operational
efficiency and equipment availability across industrial and building
applications. Harmony includes intelligent connected products and edge
terminals that visualize, gather and process data, enabling informed
operator decisions
> With just 3 clicks, you can reach the Industrial Automation • Updated quarterly
and Control catalogs, in both English and French
• Embeds product selectors and configurators,
> Download Digi-Cat with this link 360° images, training centers,
• Optimized search by commercial reference
> Find the right Training for your needs on our Global website
> Locate the training center with the selector tool, using this link
General contents
10
1
1
10
1/0
Contents General presentation and
selection guide
10
1/1
General presentation Zelio Electromechanical Relays
RSL slim and RXG interface relays
7 clear cover.
10
Single-step lockable test button
Zelio Relay RXG Latest interface relay with easy testing function
1/2
General presentation Zelio Electromechanical Relays
(continued) RXG interface and RXM miniature relays
3
RXM relays for automation control
RXM relays industrial relays bring
Easy to select
features for easy and improved control of
> Wider choice of contacts (2, 3, and 4 CO)
simple and complex automation systems. > Broad range of control circuit voltages and different socket types
> Configurator available in Apple App and Android Play Store 4
5
Convenient to use
> One-step lockable test button
> Mechanical indicator for contact status
>
6
“Power On” LED for readiness
8
LED indicator for relay status
Simple to install
> Push and stay spring clamp socket wiring (no screwdriver required) provides up
to 65% time saving
> Sockets for both DIN rail and panel mounting, time-saving bus jumper
>
9
Direct mounting with DIN rail or flange adapter
Push and stay spring clamp terminal: insert without tool
Designed to perform
> Eco-design with RoHS and REACH
> Flexible add-on protection modules
> Spring clamp socket with 20 kg/44 lb wire pull-out force and reliable retention
force on cables
10
1 1
2 2
Number and type of contacts/conventional 1 CO / 6 A 1 CO / 16 A 1 CO / 10 A
thermal current (Ith on NO contact) 1 CO / 12 A 2 CO / 5 A
2 CO / 8 A
3 Pin type
c 12…60 V
Flat (PCB type, reinforced)
6…110 V
Flat (PCB type)
6…110 V
Flat (Faston type)
3
Operational voltage Up to 400 V a/300 V c Up to 400 V a/300 V c Up to 250 V a/c
Durability Electrical, resistive load 60,000 100,000 100,000
(operating cycles per hour) Mechanical, no-load 10,000,000 30,000,000 10,000,000 for AC coil
10,000,000 for DC coil
4 4
Functions LED No Yes (with protection modules) Yes (depending on version)
Mechanical indicator No No Yes (depending on version)
Lockable test button No No Yes (depending on version)
Contact type Standard and low level Standard Standard
Type references RSL1pB4pD (1) RSBppppppp (1) RXGpppp (1)
Pages 2/3 2/5 2/9
5 Type of associated sockets Sockets with LED and protection circuit Sockets without LED Sockets
5
6 6
7 7
Contact terminal arrangements Separate Separate Separate
Connection Screw connector Spring terminals Screw connector Push-in terminals Screw connector Push-in terminals
8 8
Timer module No No No No No No
Maintaining clamps No No Yes Yes (plastic, integrated) Yes (plastic, integrated) Yes (plastic, integrated)
Socket identification legend Yes Yes Yes Yes Yes Yes
Mounting adapters for DIN rail No No No No No No
Mounting adapters with fixing lugs No No No No No No
Bus jumper Yes, 20-pole Yes, 20-pole Yes Yes, 2-pole Yes Yes, 2-pole
9 9
Conventional thermal current (Ith) 6A 6A 12 A (2 terminals) × 12 A 10 A 10 A for 1 CO 5 A for 2 CO 10 A 5A
10 A (2)
Type references RSLZVpp RSLZRpp RSZE1S35M RSZE1S48M RSZE05P RSZE08P RGZE1S35M RGZE1S48M RGZE05P RGZE08P
Pages 2/3 2/5 2/10
(1) Pre-assembled interface relays RSL1PVpp and RSL1PRpp (standard type relay + socket), RSB (relay + socket + clamp + protection module + label), and (2) When using relay RSB1A160pp with socket RSZE1S48M, terminals must be linked.
RXG (relay + socket + protection module) are also available.
10 10
1/4 1/5
Selection guide (Continued) 3
Zelio Electromechanical Relays
Plug-in relays and relays with clamp fixing
Type of product Plug-in relays Plug-in relays Relays with clamp fixing
Miniature relays Power relays Universal relays Power relays
1 1
2 2
3 3
4 CO / 6 A 3 CO / 15 A
4 CO / 3 A (low level) 4 CO / 15 A
Pin type Flat (Faston type) Flat (Faston type) Cylindrical Flat (Faston type) Flat (Faston type)
4 4
Operational voltage Up to 250 V a/c Up to 250 V a/c Up to 250 V a/c Up to 250 V a/c
100,000
Durability Electrical, resistive load 100,000 100,000 (3) 100,000
(operating cycles per hour) Mechanical, no-load 10,000,000 10,000,000 5,000,000 5,000,000
Functions LED Yes (depending on version) Yes (depending on version) Yes (depending on version) –
Mechanical indicator Yes Yes Yes –
Lockable test button Yes Yes Yes
5 Type references
Contact type Low level (depending on version)
RXMpppppp (1)
Standard
RPMpppp
Low level (depending on version)
RUMppppp
Standard –
RPFpppp
5
Pages 2/13 2/23 2/19 2/27
Type of associated sockets Sockets without LED Sockets without LED Sockets without LED
6 6
7 7
Contact terminal arrangements Mixed Separate Mixed Mixed Separate –
Connection Screw connector Screw clamp Screw connector Push-in terminals Screw clamp terminals Screw connector –
terminals
Accessories Protection modules Yes Yes Yes Yes Yes –
8 Timer module
Maintaining clamps
No
Yes
No
Yes
No
Yes (plastic, integrated)
Yes (for 3- and 4-pole)
Yes (on socket RPZF1)
Yes
Yes
–
–
8
Socket identification legend Yes No Yes Yes Yes Yes –
Mounting adapters for DIN rail Yes Yes Yes Yes No –
Mounting adapters with fixing lugs Yes Yes Yes Yes No –
9 9
Bus jumper No Yes, 2-pole (Ith = 5 A) Yes, 2-pole No No Yes, 2-pole (Ith = 5 A) –
Type references RXZE2M114M RXZE2M114 RXZE2SpppM RXZE14P RPZFp RUZCpM RUZSCpM RUZSF3M –
10 10
(1) Pre-assembled miniature relays RXM (relay + socket + clamp + label) are also available. (3) 100,000 for RPM1 and RPM2; 60,000 for RPM3 and RPM4.
(2) Except for sockets RXZE2S11pM: 10 A. (4) 30 A when mounted with 13 mm (0.51 in.) gap between two relays and 25 A when mounted side by side without a gap.
1/6 1/7
Contents Plug-in relays and relays with
clamp fixing
3 b Presentation
v Presentation of the range.......................................................................... page 2/4
v Socket description.................................................................................... page 2/4
b References.............................................................................................. page 2/5
v Pre-assembled interface relays................................................................ page 2/5
9
v Pre-assembled interface relays.............................................................. page 2/13
v Miniature relays for customer assembly.................................................. page 2/14
v Sockets................................................................................................... page 2/15
v Protection modules................................................................................. page 2/15
v Timing relays.......................................................................................... page 2/15
2/0
Contents (continued) Plug-in relays and relays with
clamp fixing
Technical presentation
b Relays.................................................................................................... page 2/28
b Protection modules.............................................................................. page 2/29
7
10
2/1
Presentation Zelio Electromechanical Relays
Plug-in relays
RSL slim interface relays
1 Relay description
4
RSL slim interface relays, pre-assembled
2
4
1 6 A standard relay with 1 CO contact
2 Lever for retaining or easy withdrawal of the relay from its socket
3 3 Sockets: wire connection by screw connectors or spring terminals
4 Built-in protection circuit and LED indicator on all sockets
1 Socket description
Sockets for RSL slim interface relays
8 4 2
1 5 female contacts for the relay pins
2 Retaining lever with marker label
3 3 Wire connection by screw connectors or spring terminals
4 Built-in protection circuit and LED indicator
5 Locating slot for mounting on DIN rail
10
5
2/2
References Zelio Electromechanical Relays
Plug-in relays
RSL slim interface relays
PF120938
Standard relays mounted on socket equipped with LED and protection circuit
1 CO contact - Thermal current (Ith) 6A 1
Operating voltage Control circuit Socket type
V voltage Screw connector Spring terminal
V
Unit reference Weight Unit reference Weight
kg/lb kg/lb
c/a 12 c 12 RSL1PVJU 0.031/0.068 RSL1PRJU 0.029/0.064
(RSL1AB4JD + RSLZVA1) (RSL1AB4JD + RSLZRA1)
2
c/a 24 c 24 RSL1PVBU 0.031/0.068 RSL1PRBU 0.029/0.064
(RSL1AB4BD + RSLZVA1) (RSL1AB4BD + RSLZRA1)
5
c 12 RSL1AB4JD 0.006/0.013 RSL1GB4JD 0.006/0.013
7
kg/lb kg/lb
c/a 12 and c/a 24 RSL1pB4JD RSLZVA1 0.025/0.055 RSLZRA1 0.023/0.051
RSL1pB4BD
Socket accessories
Description For use with Reference Weight
PF121806
kg/lb
RSLZ2
Clip-in legends
(2 sheets of 64
All sockets RSLZ5 0.001/0.002
9
legends)
PF121804
RSLZ3
2/3
Presentation Zelio Electromechanical Relays
Plug-in relays
RSB interface relays
1
2 1 12 A relays with 1 CO contact , 16 A relays with 1 CO contact, and 8 A relays with 2
CO contacts
2 Sockets with separate contact terminals
3 Protection modules (diode, diode + LED, RC circuit, or varistor + LED) common to
all sockets
4 A plastic maintaining clamp for all sockets
4 5 Clip-in legend for all sockets
2 These relays are available in both pre-assembled (single reference) and customer
assembled offers.
1
3 3
4 1a
Inputs
Socket description
Sockets with separate contact terminals (1)
1 a Connection by connector
b Connection by push-in terminal
2 5 or 8 female contacts for the relay pins
Outputs 3 Hole for panel mounting
4 Location for protection modules
5
2 5 a Locking components for plastic maintaining clamp
5a b Built-in plastic maintaining clamp for locking components
3 6 Locating slot for mounting on DIN rail
7 Test point
4 8 Push button to release wire
9 Location for bus jumpers
6 6 Relay supply
Inputs
1b
7 Outputs
8 5b
4
7
8
(1) The inputs and outputs are separate from the relay supply.
Relay supply
9 6 9
10
2/4
References Zelio Electromechanical Relays
Plug-in relays
RSB interface relays
Relays mounted on sockets with protection module (LED version) and integrated clamp
(sold in lots of 30) 1
Control Number and types of contact - Thermal current (Ith)
circuit
1 CO - 12 A 1 CO - 16 A 2 CO- 8 A
voltage
V Unit Reference Weight Unit Reference Weight Unit Reference Weight
kg/lb kg/lb kg/lb
4
RSZE1S35M + RSZE1S48M +
RSZR215 + RSZR215 +
RZM021RB + RZM021RB +
RSZL300) RSZL300)
10
2/5
References (continued) Zelio Electromechanical Relays
Plug-in relays
RSB interface relays
PF153636A
3
+ RSZE1S35M c 110 RSB1A120FD RSB1A160FD RSB2A080FD 0.014/0.031
6 Sockets with separate contact terminal arrangement, push in terminals, and built-in
clamp
XBK_CP19314D
7
10 A RSB2Appppp 10 RSZE08P 0.042/0.093
Protection modules
Description For Voltage Sold in Unit Weight
use with V lots of reference kg/lb
9
c 110…230 10 RZM031FPD 0.004/0.009
10
(1) RSZE1S48M is a two terminal socket each carrying 10 A.
(2) If RSZE1S48M /RSZE08P socket terminals are linked, relay RSB1A160pp can be used up to 16 A. See “Wiring diagrams” on
www.schneider-electric.com.
Note: Starting from 2020, Zelio Relays range name will change to Harmony Relays. As the timeline for each range is different,
there will be both Zelio and Harmony range during the transition period.
2/6
References (continued) Zelio Electromechanical Relays
Plug-in relays
RSB interface relays
Accessories
Description For Sold in Unit Weight
use with lots of reference kg/lb
1
XBK_CP19466
RSZR215
3
RS_532_CPSCT17003-68-Q
4
XBK_CP19318
5
RSZS02
10
2/7
Presentation Zelio Electromechanical Relays
Plug-in relays
RXG interface relays
2
Presentation of the range
4
RXG relays are interface plug-in relays with Faston pins for better reliability and
1 robust installation. They are used in PLC applications.
2 1
all RXG sockets
4 Clip-in legends for all RXG sockets
These relays are available in both pre-assembled (single reference) and customer
assembled offers.
3
3 6 Relay description
1 Spring-return pushbutton for testing the contacts (green: c, red: a)
5
2 Mechanical “relay status” indicator
3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes
5
7 3 2 4 8
1a Socket description
Inputs Sockets with separate contact terminals (1)
6 1 a Connection by connector
b Connection by push-in terminal
Outputs 2 5 or 8 female contacts for the relay pins
2 3 Hole for panel mounting
4 Location for protection modules
3
4 5 Built-in plastic maintaining clamp for locking components
7 5 6 Locating slot for mounting on DIN rail
7 Test point
8 Push button to release wire
6 9 Location for bus jumpers
Relay supply
8 Inputs
1b
7
Outputs
9 2
5
8
10 6
(1) The inputs and outputs are separate from the relay supply.
Relay supply
9
2/8
References Zelio Electromechanical Relays
Plug-in relays
RXG interface relays
Relays with lockable test button and LED, mounted on sockets with protection module and integrated clamp
Control
circuit
Sold in
lots of
Number and type of contacts - Thermal current (Ith)
1 CO - 10 A 2 CO - 5 A
1
voltage
V Unit reference Weight Unit reference Weight
kg/lb kg/lb
24 c 30 RXG12BDPV 0.059/0.130 RXG22BDPV 0.066/0.145
(RXG12BD + RGZE1S35M (RXG22BD + RGZE1S48M
+ RZM031RB) + RZM031RB)
24 a 30 RXG12B7PV
(RXG12B7 + RGZE1S35M
0.059/0.130 RXG22B7PV
(RXG22B7 + RGZE1S48M
0.067/0.148 2
+ RZM021RB) + RZM021RB)
230 a 30 RXG12P7PV 0.059/0.130 RXG22P7PV 0.067/0.148
(RXG12P7 + RGZE1S35M (RXG22P7 + RGZE1S48M
RXG22BDPV + RZM021FP) + RZM021FP)
Relays with LED, mounted on sockets with protection module, and integrated clamp and LED
24 c 30 RXG13BDPV 0.058/0.129 RXG23BDPV 0.066/0.145 3
(RXG13BD + RGZE1S35M (RXG23BD + RGZE1S48M
+ RZM031RB) + RZM031RB)
230 a 30 RXG13P7PV 0.059/0.130 RXG23P7PV 0.067/0.148
(RXG13P7 + RGZE1S35M (RXG23P7 + RGZE1S48M
+ RZM021FP) + RZM021FP)
Relays with lockable test button and without LED, mounted on sockets with protection module,
and integrated clamp and LED
4
24 c 30 RXG21BDPV 0.067/0.148
(RXG21BD + RGZE1S48M
+ RZM031RB)
24 a 30 RXG21B7PV 0.067/0.148
(RXG21B7 + RGZE1S48M
230 a 30
+ RZM021RB)
RXG21P7PV 0.067/0.148
5
(RXG21P7 + RGZE1S48M
+ RZM021FP)
PF132501
RXG11RD
60 c 10 RXG11ND RXG21ND 0.020/0.044
7
110 c 10 RXG11FD RXG21FD 0.020/0.044
10
2/9
References (continued) Zelio Electromechanical Relays
Plug-in relays
RXG interface relays
V 1 CO - 10 A 2 CO - 5 A
Unit reference Unit reference Weight
kg/lb
PF132510
2
12 c 10 RXG12JD RXG22JD 0.020/0.044
3 RXG22B7
24 a
48 a
10
10
RXG12B7
RXG12E7
RXG22B7
RXG22E7
0.020/0.044
0.020/0.044
7 12 c
24 c
10
10
RXG15JD
RXG15BD
RXG25JD
RXG25BD
0.019/0.042
0.019/0.042
8 RXG15RD
24 a 10 RXG15B7 RXG25B7 0.018/0.040
10
2/10
References (continued) Zelio Electromechanical Relays
Plug-in relays
RXG interface relays
Sockets with separate contact terminal arrangement, push-in terminals, and built-in
clamp
2
Description Thermal Relay type Sold in Unit Weight
current (Ith) lots of reference kg/lb
RGZE1S48M 1 CO socket with 1 pole 10 A RXG1ppp 10 RGZE05P 0.039/0.086
XBK_CP19316B
RXG2ppp RGZE08P
3
2 CO socket with 2 poles 5A 10 0.042/0.093
Protection modules
Description For Voltage Sold in Unit Weight
use with V lots of reference kg/lb
4
RC circuit All sockets a 24…60 10 RZM041BN7 0.010/0.022
RGZE05P
a 110…240 10 RZM041FU7 0.010/0.022
5
PF132522
6
PF132519
7
RS_532_CPSCT17003
Accessories
8
PF132518
RSZS02
Bus jumper
(10 x 2-pole jumper)
For input (A2) of RGZE 10
push-in sockets
RSZS02 0.002/0.004
10
(RGZE05P, RGZE08P)
Note: Starting from 2020, Zelio Relays range name will change to Harmony Relays. As the timeline for each range is different,
there will be both Zelio and Harmony range during the transition period.
2/11
Presentation Zelio Electromechanical Relays
Plug-in relays
RXM miniature relays
8
1
4 2
3
7 6 5
5
9 Relay description
1 Spring-return pushbutton for testing the contacts (green: c, red: a)
2 Mechanical “relay status” indicator
3 Removable lock-down door enabling forced maintaining of the contacts for test
6 sequences or maintenance purposes
4 LED (depending on version) indicating the relay status
5 Removable legend for relay identification
6 4 notches for rail mounting adapter or panel mounting adapter with mounting lugs
9 7 8, 11, or 14 Faston type pins
8 Area by which the product can be easily gripped
9 Mounting adapter enabling direct mounting of the relay on a panel
7 10 Mounting adapter enabling direct mounting of the relay on a DIN rail
10
10
2/12
Presentation (continued) Zelio Electromechanical Relays
Plug-in relays
RXM miniature relays
6
Socket description
Sockets with mixed contact terminals (1)
1 1 Connection by screw clamp terminals or screw connector
2 14 female contacts for the relay pins
1
3 Location for protection modules
Outputs 4 Locking components for plastic and metal maintaining clamps
5 Locating slot for mounting on DIN rail with compression spring or mounting clip
2 6 2 or 4 holes for panel mounting
4 2
3
Inputs
3
5 Relay supply
Sockets with mixed contact terminals
Sockets with separate contact terminals (2)
1 a Connection by connector
5
b Connection by push in terminal
1a 2 8, 11, or 14 female contacts for the relay pins
Inputs 3 a Locking components for plastic and metal maintaining clamps
b Built-in plastic maintaining clamp for locking components
4 Location for protection modules 4
5 Locating slot for mounting on DIN rail with compression spring or mounting clip
Outputs 6 2 holes for panel mounting
2 7 Test point
8 Push button to release wire
3a 9 Location for bus jumpers
4
5
6 9 Relay supply
Sockets with separate contact terminals
5 6
1b
Inputs
Outputs
2
7
3b
4
7
8 8
9 Relay supply
Sockets with separate contact terminals
(1) The inputs are mixed with the relay supply, with the outputs being located on the opposite
side of the socket.
(2) The inputs and outputs are separate from the relay supply.
10
2/13
References Zelio Electromechanical Relays
Plug-in relays
RXM miniature relays
Relays without LED, mounted on sockets with clamp and socket legend (sold in lots of 30)
1 Control Type of
circuit socket
Number and type of contacts - Thermal current (Ith)
2 CO - 12 A 4 CO - 6 A
voltage
V Unit reference Weight Unit reference Weight
kg/lb kg/lb
2 socket RXZE2M114M +
RXZR335 + RXZL520)
24 a – – RXM4AB1B7PVM 0.099/
(RXM4AB1B7 + 0.218
RXZE2M114M +
RXM4AB1BDPVS RXZR335 + RXZL520)
RXZR335 + RXZL520)
4 24 a – – RXM4AB1B7PVS
(RXM4AB1B7 +
0.113/
0.249
RXZE2S114M +
RXZR335 + RXZL520)
Relays with LED, mounted on sockets with clamp and socket legend (sold in lots of 30)
24 c Mixed RXM2AB2BDPVM 0.099/ RXM4AB2BDPVM 0.099/
terminal (RXM2AB2BD + 0.218 (RXM4AB2BD + 0.218
socket RXZE2M114M + RXZE2M114M +
RXZR335 + RXZL520) RXZR335 + RXZL520)
6 24 a RXM2AB2B7PVM
(RXM2AB2B7 +
RXZE2M114M +
0.099/ RXM4AB2B7PVM
0.218 (RXM4AB2B7 +
RXZE2M114M +
0.099/
0.218
8
RXZE2S108M + RXZE2S114M +
RXZR335 + RXZL520) RXZR335 + RXZL520)
10
2/14
References (continued) Zelio Electromechanical Relays
Plug-in relays
RXM miniature relays
2
PF106011
3
a 120 RXM2AB1F7 0.037/0 .082 RXM3AB1F7 0.037/0.082 RXM4AB1F7 0.037/0.082
RXM2AB1F7
a 230 RXM2AB1P7 0.037/0 .082 RXM3AB1P7 0.037/0.082 RXM4AB1P7 0.037/0.082
PF153504
4
c 24 RXM2AB2BD 0.037/0 .082 RXM3AB2BD 0.037/0.082 RXM4AB2BD 0.037/0.082
c 48 RXM2AB2ED 0.037/0 .082 RXM3AB2ED 0.037/0.082 RXM4AB2ED 0.037/0.082
RXM2AB2ED c 110 RXM2AB2FD 0.037/0 .082 RXM3AB2FD 0.037/0.082 RXM4AB2FD 0.037/0.082
c 125 – – – – RXM4AB2GD 0.037/0.082
PF153506
V
6
4 CO - 3 A
Unit Weight
reference kg/lb
c 12 RXM4GB1JD 0.037/0.082
c 24 RXM4GB1BD 0.037/0.082
c 48 RXM4GB1ED 0.037/0.082
RXM4GB1BD
c 110 RXM4GB1FD 0.037/0.082
7
PF153500A
a 24 RXM4GB1B7 0.037/0.082
a 48 RXM4GB1E7 0.037/0.082
a 120 RXM4GB1F7 0.037/0.082
a 230 RXM4GB1P7 0.037/0.082
RXM4GB1P7
RXM miniature relays with low level contacts, with LED (sold in lots of 10)
c 12 RXM4GB2JD 0.037/0.082
8
c 24 RXM4GB2BD 0.037/0.082
PF153504A
c 48 RXM4GB2ED 0.037/0.082
c 60 RXM4GB2ND 0.037/0.082
9
c 110 RXM4GB2FD 0.037/0.082
c 125 RXM4GB2GD 0.037/0.082
c 220 RXM4GB2MD 0.037/0.082
RXM4GB2BD
a 24 RXM4GB2B7 0.037/0.082
PF153506A
a 48 RXM4GB2E7 0.037/0.082
a 120 RXM4GB2F7 0.037/0.082
a 230 RXM4GB2P7 0.037/0.082 10
a 240 RXM4GB2U7 0.037/0.082
RXM4GB2F7
2/15
References (continued) Zelio Electromechanical Relays
Plug-in relays
RXM miniature relays
Sockets
Contact terminal Connection Relay type Sold in Unit Weight
1 arrangement lots of reference kg/lb
PF153537A
3 RXZE2S108M
+
Screw connector RXM2ppppp 10 RXZE2S108M (2) 0.058/0.128
Relay RXM4AB1F7
RXM3ppppp 10 RXZE2S111M (1) 0.066/0.146
4
RXM4ppppp 10 RXZE2S114M (1) 0.070/0.154
5 Protection modules
Description Voltage For Sold in Unit Weight
V use with lots of reference kg/lb
Diode c 6...250 All sockets 10 RXM040W 0.003/0.007
6
PF106018
RXM041pp7
a 110...240 All sockets 10 RXM041FU7 0.010/0.022
Timing relays
Description For Unit Weight
use with reference kg/lb
9 2 or 4 timed CO contacts (function A) RXZEpppppp sockets REXL2pp (4) –
REXL4pp (4) –
2/16
References (continued) Zelio Electromechanical Relays
Plug-in relays
RXM miniature relays
Accessories
RE_529_CPFJR18001B
REXL4pp Plastic maintaining clamp All sockets except push-in 10 RXZR335 0.005/0.011
socket RXZE14P
XBK_CP193219A
RXZR315
2-pole bus jumper (Ith: 5 A) All screw sockets with 10 RXZS2 0.005/0.011
separate contacts
(RXZE2Spppp)
PF153530A
RSZS02
Mounting adapter with panel mounting lugs All relays 10 RXZE2FA 0.002/0.004
PF153531
RXZE2DA
RXZL520
2/17
Presentation Zelio Electromechanical Relays
Plug-in relays
RUM universal relays
5 3
3 6 Relay description
1 1 Spring-return pushbutton for testing the contacts (green: c, red: a)
2 2 Mechanical “relay status” indicator
3 Removable lock-down door enabling forced maintaining of the contacts for test
3
sequences or maintenance purposes (1)
4
4 4 LED (depending on version) indicating the relay status
5 Removable legend for relay identification
5 6 Area by which the product can be easily gripped
7 8 or 11 cylindrical pins
8 8 or 11 flat (Faston type) pins
5
7 8
6 1
Inputs
Socket description
Sockets with separate contact terminals (3)
1 Connection by screw connector
2 a 8 or 11 female contacts for the relay cylindrical pins
Outputs b 11 female contacts for the relay flat pins
3 Location for protection modules or the timer module
4 4 Locking component for metal maintaining clamp
7 2a
5 Locating slot for mounting on DIN rail with mounting clip
6 2 holes for panel mounting
3 7 Location for bus jumpers (see dimensions for mounting on sockets on
www.schneider-electric.com)
57 5 Relay supply
8
1
Inputs
Outputs
9 2b
10
(1) During operation, this lock-down door must always be in the closed position.
57 5 Relay supply (2) The inputs are mixed with the relay supply, with the outputs being located on the opposite
side of the socket.
(3) The inputs and outputs are separate from the relay supply.
2/18
References Zelio Electromechanical Relays
Plug-in relays
RUM universal relays
2
3
Relay
supply
5 Inputs
Relay suppy
Universal relays for customer assembly
Relays for standard applications, with lockable test button and without LED (sold in lots of 10)
Pins Control Number and type of contacts - Thermal current (Ith)
3
circuit voltage
PF140700C
2 CO - 10 A 3 CO - 10 A
V
Unit Weight Unit Weight
reference kg/lb reference kg/lb
c 24
c 48
RUMC21BD
RUMC21ED
0.086/0.190
0.086/0.190
RUMC31BD
RUMC31ED
0.086/0.190
0.086/0.190
4
RUMC21BD c 60 – – RUMC31ND 0.086/0.190
c 110 RUMC21FD 0.086/0.190 RUMC31FD 0.086/0.190
c 125 – – RUMC31GD 0.086/0.190
c 220 – – RUMC31MD 0.086/0.190
Relays for standard applications, with lockable test button and LED (sold in lots of 10)
Cylindrical c 12 RUMC22JD 0.086/0.190 RUMC32JD 0.086/0.190
c 24 RUMC22BD 0.086/0.190 RUMC32BD 0.086/0.190
c 48 RUMC22ED 0.086/0.190 RUMC32ED 0.086/0.190
RUMC32BD c 60
c 110
–
RUMC22FD 0.086/0.190
– RUMC32ND
RUMC32FD
0.086/0.190
0.086/0.190
8
c 125 – – RUMC32GD 0.086/0.190
a 120
a 230
RUMC22F7
RUMC22P7
0.086/0.190
0.086/0.190
RUMC32F7
RUMC32P7
0.086/0.190
0.086/0.190
9
Flat (Faston type) c 12 RUMF22JD 0.086/0.190 RUMF32JD 0.086/0.190
c 24 RUMF22BD 0.086/0.190 RUMF32BD 0.086/0.190
c 48 RUMF22ED 0.086/0.190 RUMF32ED 0.086/0.190
c 110 RUMF22FD 0.086/0.190 RUMF32FD 0.086/0.190
10
RUMF32F7
2/19
References (continued) Zelio Electromechanical Relays
Plug-in relays
RUM universal relays
Sockets
PF140733B
2 RUMF2ppp
RUMF3ppp
10 RUZSF3M 0.095/0.209
Protection modules
RUZSC3M + Description For Voltage Sold in Unit Weight
Relay RUMC3ppp use with V lots of reference kg/lb
Timer module
4 Description For
use with
Voltage
V
Reference Weight
kg/lb
Timing relays
5
Description For Reference Weight
RUW101MW use with kg/lb
10
2/20
References (continued) Zelio Electromechanical Relays
Plug-in relays
RUM universal relays
Accessories
Description For Sold in Unit Weight
2-pole bus jumper (Ith: 5 A) All RUM sockets with separate contacts 10 RUZS2 0.005/0.011
RUZC200
2
Clip-in legends All relays 10 RXZL520 0.086/0.190
(sheet of 108 legends)
3
DF535203
RUZS2
10
2/21
Presentation Zelio Electromechanical Relays
Plug-in relays
RPM power relays
2
3
3
1 8
Relay description
1 Spring-return pushbutton for testing the contacts (green: c, red: a)
2 Mechanical “relay status” indicator
4
2
3 3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes
4 4 LED (depending on version) indicating the relay status
5 Removable legend for relay identification
6 4 notches for rail mounting adapter or panel mounting adapter with mounting lugs
7 6 5 7 5, 8, 11, or 14 Faston type pins
8 Area by which the product can be easily gripped
5 9 Mounting adapter enabling direct mounting of the relay on a panel
10 Mounting adapter enabling direct mounting of the relay on a 5 rail
9 9
6
7
10
5 Socket description
7 1
Sockets with mixed contact terminals (1)
1 Connection by screw clamp terminals
Outputs
2 5, 8, 11, or 14 female contacts for the relay pins
3 Location for protection modules or the timer module
4 Locating slot for mounting on rail with mounting clip
5 2 or 4 holes for panel mounting
2
8 (1) The inputs are mixed with the relay supply, with the outputs being located on the opposite
side of the socket.
9 Relay supply
4 Inputs
10
2/22
References Zelio Electromechanical Relays
Plug-in relays
RPM power relays
3
PF142818B
5
c 24 RPM12BD 0.026/0 .057 RPM22BD 0.036/0 .079 RPM32BD 0.054/0 .119 RPM42BD 0.071/0.157
c 48 RPM12ED 0.026/0 .057 RPM22ED 0.036/0 .079 RPM32ED 0.054/0 .119 RPM42ED 0.071/0.157
RPM42BD
c 110 RPM12FD 0.026/0 .057 RPM22FD 0.036/0 .079 RPM32FD 0.054/0.119 RPM42FD 0.071/0.157
7
RPM42P7
a 230 RPM12P7 0.026/0.057 RPM22P7 0.036/0.079 RPM32P7 0.054/0.119 RPM42P7 0.071/0.157
10
2/23
References (continued) Zelio Electromechanical Relays
Plug-in relays
RPM power relays
Sockets
PF142831B
3 RPZF2
PF106044
5 a/c 24 RPZF3
RPZF4
10 RUW242B7 0.004/0.009
(1) See timer module description (selection of functions and time delays) on www.schneider-electric.com.
10
2/24
References (continued) Zelio Electromechanical Relays
Plug-in relays
RPM power relays
Accessories
Description For Sold in Unit Weight
use with lots of reference kg/lb
1
PF106045
3
PF106046
5
Clip-in legends All relays 10 RXZL520 0.080/0.176
(sheet of 108 legends)
10
2/25
Presentation Zelio Electromechanical Relays
Relays with clamp mounting
RPF power relays
1
4 RPF power relays with 2 CO or 2 NO contacts comprise:
2
3
3
10
2/26
References Zelio Electromechanical Relays
Relays with clamp mounting
RPF power relays
Power relays
Control Sold in lots Number and type of contacts - Thermal current (Ith)
PF120361C
circuit
voltage
2 NO - 30 A (1)
Unit
2 CO - 30 A (1)
Unit Weight
1
V
reference reference kg/lb
10
2/27
Technical presentation Zelio Electromechanical Relays
Plug-in relays
Relays
Contact types
1 Symbol Configuration
Make contact
EU
NO
USA
SPST-NO
(Normally Open) DPST-NO
nPST-NO (1)
2 nPST-NC (1)
3 Utilization categories
Category Type of current Applications
AC-1 a 1-phase Resistive or slightly inductive loads
a 3-phase
6
electromagnets
Protection categories
Category Explanation Condition
RT 0 Unenclosed relay Relay not provided with a protective case
7 RT I Dust protected
relay
Relay provided with a case that helps to protect its
mechanism from dust
10
2/28
Technical presentation Zelio Electromechanical Relays
(continued) Plug-in relays
Protection modules
Whenever an inductive load is de-energized (coil of a relay or of a contactor), an
overvoltage appears at its terminals. This voltage peak can reach several thousand
volts and a frequency of several MHz.
1
It is likely to disturb the operation of automation systems that contain electronic
devices.
Protection modules are used to reduce the voltage peak on de-energization and
therefore limit the energy of interference signals to a level that will not disturb
surrounding coils and electronic devices.
6
peaks
Energy
released
S2 (with RC)
U2
S1
9
Coil voltage with RC circuit protection module (a only)
S1 = S2 = Energy released
10
2/29
1
10
3/0
Contents Index
Index
b Product reference index......................................................................... page 3/2
1
10
3/1
Index Zelio Electromechanical Relays
Product reference Index
1 RGZE1S48M
RGZE05P
2/11
2/11
RPM32JD
RPM32P7
2/23
2/23
RSB2A080E7
RSB2A080ED
2/6
2/6
RUMC22E7
RUMC22ED
2/19
2/19
RUW241P7 2/20
2/24
RUW242B7 2/20
RGZE08P 2/11 RPM41B7 2/23 RSB2A080F7 2/6 RUMC22F7 2/19 2/24
RGZL520 2/11 RPM41BD 2/23 RSB2A080F7PV 2/5 RUMC22FD 2/19 RUW242P7 2/20
2/25 RPM41E7 2/23 RSB2A080FD 2/6 RUMC22JD 2/19 2/24
RGZR215 2/11 RPM41ED 2/23 RSB2A080JD 2/6 RUMC22P7 2/19 RUZC2M 2/20
2
RGZS08 2/7 RPM41F7 2/23 RSB2A080JDPV 2/5 RUMC31B7 2/19 RUZC3M 2/20
2/11
RPM41FD 2/23 RSB2A080M7 2/6 RUMC31BD 2/19 RUZC200 2/21
RPF2AB7 2/27
RPM41JD 2/23 RSB2A080M7PV 2/5 RUMC31E7 2/19 RUZL420 2/21
RPF2ABD 2/27
RPM41P7 2/23 RSB2A080ND 2/6 RUMC31ED 2/19 RUZS2 2/21
RPF2AF7 2/27
RPM42B7 2/23 RSB2A080P7 2/6 RUMC31F7 2/19 RUZSC2M 2/20
RPF2AJD 2/27
RPM42BD 2/23 RSB2A080P7PV 2/5 RUMC31FD 2/19 RUZSC3M 2/20
RPF2AP7 2/27
3
RPM42E7 2/23 RSB2A080RD 2/6 RUMC31GD 2/19 RUZSF3M 2/20
RPF2BB7 2/27
RPM42ED 2/23 RSB2A080U7 2/6 RUMC31JD 2/19 RXG11B7 2/9
RPF2BBD 2/27
RPM42F7 2/23 RSL1AB4BD 2/3 RUMC31MD 2/19 RXG11BD 2/9
RPF2BF7 2/27
RPM42FD 2/23 RSL1AB4ED 2/3 RUMC31ND 2/19 RXG11E7 2/9
RPF2BJD 2/27
RPM42JD 2/23 RSL1AB4JD 2/3 RUMC31P7 2/19 RXG11ED 2/9
RPF2BP7 2/27
RPM42P7 2/23 RSL1AB4ND 2/3 RUMC32B7 2/19 RXG11F7 2/9
RPM11B7 2/23
RPZ1DA 2/25 RSL1GB4BD 2/3 RUMC32BD 2/19 RXG11FD 2/9
4 RPM11BD
RPM11E7
2/23
2/23
RPZ1FA
RPZ3DA
2/25
2/25
RSL1GB4ED
RSL1GB4JD
2/3
2/3
RUMC32E7
RUMC32ED
2/19
2/19
RXG11JD
RXG11M7
2/9
2/9
RPM11ED 2/23
RPZ3FA 2/25 RSL1GB4ND 2/3 RUMC32F7 2/19 RXG11ND 2/9
RPM11F7 2/23
RPZ4DA 2/25 RSL1PRBU 2/3 RUMC32FD 2/19 RXG11P7 2/9
RPM11FD 2/23
RPZ4FA 2/25 RSLZRA1 2/3 RUMC32GD 2/19 RXG11RD 2/9
RPM11JD 2/23
RPZF1 2/24 RSL1PREU 2/3 RUMC32JD 2/19 RXG12B7 2/10
5
RPM11P7 2/23 RPZF2 2/24 RSLZRA2 2/3 RUMC32ND 2/19 RXG12B7PV 2/9
RPM12B7 2/23 RPZF3 2/24 RSL1PRFU 2/3 RUMC32P7 2/19 RXG12BD 2/10
RPM12BD 2/23 RPZF4 2/24 RSLZRA3 2/3 RUMF21B7 2/19 RXG12E7 2/10
RPM12E7 2/23 RPZR235 2/25 RSL1PRJU 2/3 RUMF21BD 2/19 RXG12ED 2/10
RPM12ED 2/23 RSB1A120B7 2/6 RSL1PRPU 2/3 RUMF21E7 2/19 RXG12F7 2/10
RPM12F7 2/23 RSB1A120B7PV 2/5 RSLZRA4 2/3 RUMF21ED 2/19 RXG12FD 2/10
RPM12FD 2/23
6
RSB1A120BD 2/6 RSL1PVBU 2/3 RUMF21F7 2/19 RXG12JD 2/10
RPM12JD 2/23 RSB1A120BDPV 2/5 RSLZVA1 2/3 RUMF21FD 2/19 RXG12M7 2/10
RPM12P7 2/23 RSB1A120E7 2/6 RSL1PVEU 2/3 RUMF21JD 2/19 RXG12ND 2/10
RPM21B7 2/23 RSB1A120ED 2/6 RSLZVA2 2/3 RUMF21P7 2/19 RXG12P7 2/10
RPM21BD 2/23 RSB1A120F7 2/6 RSL1PVFU 2/3 RUMF22B7 2/19 RXG12P7PV 2/9
RPM21E7 2/23 RSB1A120F7PV 2/5 RSLZVA3 2/3 RUMF22BD 2/19 RXG12RD 2/10
RPM21ED 2/23 RSB1A120FD 2/6 RSL1PVJU 2/3 RUMF22E7 2/19 RXG13B7 2/10
7 RPM21F7
RPM21FD
2/23
2/23
RSB1A120JD
RSB1A120JDPV
2/6
2/5
RSL1PVPU
RSLZVA4
2/3
2/3
RUMF22ED
RUMF22F7
2/19
2/19
RXG13BD
RXG13BDPV
2/10
2/9
RPM21JD 2/23 RSB1A120M7 2/6 RSLZ2 2/3 RUMF22FD 2/19 RXG13E7 2/10
RPM21P7 2/23 RSB1A120ND 2/6 RSLZ3 2/3 RUMF22JD 2/19 RXG13ED 2/10
RPM22B7 2/23 RSB1A120P7 2/6 RSLZ5 2/3 RUMF22P7 2/19 RXG13F7 2/10
RPM22BD 2/23 RSB1A120P7PV 2/5 RSZE1S35M 2/6 RUMF31B7 2/19 RXG13FD 2/10
8 RPM22E7
RPM22ED
2/23
2/23
RSB1A120RD
RSB1A120U7
2/6
2/6
RSZE1S48M
RSZE05P
2/6
2/6
RUMF31BD
RUMF31E7
2/19
2/19
RXG13JD
RXG13M7
2/10
2/10
RPM22F7 2/23 RSB1A160B7 2/6 RSZE08P 2/6 RUMF31ED 2/19 RXG13ND 2/10
RPM22FD 2/23 RSB1A160BD 2/6 RSZL300 2/7 RUMF31F7 2/19 RXG13P7 2/10
RPM22JD 2/23 RSB1A160BDPV 2/5 2/11 RUMF31FD 2/19 RXG13P7PV 2/9
RPM22P7 2/23 2/17
RSB1A160E7 2/6 RUMF31JD 2/19 RXG13RD 2/10
RSZR215 2/7
9
RPM31B7 2/23 RSB1A160ED 2/6 RUMF31P7 2/19 RXG15B7 2/10
RPM31BD 2/23 RSZS02 2/7
RSB1A160F7 2/6 RUMF32B7 2/19 RXG15BD 2/10
2/11
RPM31E7 2/23 RSB1A160FD 2/6 RUMF32BD 2/19 RXG15E7 2/10
2/17
RPM31ED 2/23 RSB1A160JD 2/6 RUMF32E7 2/19 RXG15ED 2/10
RUMC21B7 2/19
RPM31F7 2/23 RSB1A160M7 2/6 RUMF32ED 2/19 RXG15F7 2/10
RUMC21BD 2/19
RPM31FD 2/23 RSB1A160ND 2/6 RUMF32F7 2/19 RXG15FD 2/10
RUMC21E7 2/19
RPM31JD 2/23 RSB1A160P7 2/6 RUMF32FD 2/19 RXG15JD 2/10
10
RUMC21ED 2/19
RPM31P7 2/23 RSB1A160P7PV 2/5 RUMF32JD 2/19 RXG15M7 2/10
RUMC21F7 2/19
RPM32B7 2/23 RSB1A160RD 2/6 RUMF32P7 2/19 RXG15ND 2/10
RUMC21FD 2/19
RPM32BD 2/23 RSB1A160U7 2/6 RUW101MW 2/20 RXG15P7 2/10
RUMC21JD 2/19
RPM32E7 2/23 RSB2A080B7 2/6 2/24 RXG15RD 2/10
RUMC21P7 2/19
RPM32ED 2/23 RSB2A080B7PV 2/5
3/2
Index (continued) Zelio Electromechanical Relays
Product reference Index
6
RXG23F7 2/10 RXM4AB1ED 2/15 RXZE2S114S 2/16
RXG23FD 2/10 RXM4AB1F7 2/15 RXZE14P 2/16
RXG23JD 2/10 RXM4AB1FD 2/15 RXZL300 2/17
RXG23M7 2/10 RXM4AB1JD 2/15 RXZL420 2/17
RXG23ND 2/10 RXM4AB1MD 2/15 RXZL520 2/17
RXG23P7 2/10 RXM4AB1P7 2/15 2/21
RXG23P7PV 2/9 RXM4AB1P7PVM 2/14 2/25
RXG23RD
RXG25B7
2/10
2/10
RXM4AB1P7PVS
RXM4AB1U7
2/14
2/15
RXZR315
RXZR335
2/17
2/17
7
RXG25BD 2/10 RXM4AB2B7 2/15 RXZS2 2/17
RXG25E7 2/10 RXM4AB2B7PVM 2/14 RZM021BN 2/6
2/11
RXG25ED 2/10 RXM4AB2B7PVS 2/14
RZM021FP 2/6
RXG25F7 2/10 RXM4AB2BD 2/15
2/11
RXG25FD
RXG25JD
2/10
2/10
RXM4AB2BDPVM
RXM4AB2BDPVS
2/14
2/14
RZM021RB 2/6
2/11
8
RXG25M7 2/10 RXM4AB2E7 2/15 RZM031BN 2/6
RXG25ND 2/10 RXM4AB2ED 2/15 2/11
RXG25P7 2/10 RXM4AB2F7 2/15 RZM031FPD 2/6
RXG25RD 2/10 RXM4AB2FD 2/15 2/11
RZM031RB 2/6
9
RXM2AB1B7 2/15 RXM4AB2GD 2/15
2/11
RXM2AB1BD 2/15 RXM4AB2JD 2/15
RZM040W 2/6
RXM2AB1E7 2/15 RXM4AB2P7 2/15 2/11
RXM2AB1ED 2/15 RXM4AB2P7PVM 2/14 RZM041BN7 2/6
RXM2AB1F7 2/15 RXM4AB2P7PVS 2/14 2/11
RXM2AB1FD 2/15 RXM4GB1B7 2/15 RZM041FU7 2/6
RXM2AB1JD 2/15 RXM4GB1BD 2/15 2/11
RXM2AB1P7
RXM2AB2B7
2/15
2/15
RXM4GB1E7
RXM4GB1ED
2/15
2/15
10
RXM2AB2B7PVM 2/14 RXM4GB1F7 2/15
RXM2AB2B7PVS 2/14 RXM4GB1FD 2/15
RXM2AB2BD 2/15 RXM4GB1JD 2/15
3/3
Learn more about our products at
www.schneider-electric.com/relays
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the
products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability
of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk
analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric
nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
DIA5ED2130303EN
March 2020 - V4.0