ONYXWorks® Lite
Installation and Operation Manual
Document LS10050-003NF-E
6/5/2015 Rev:
P/N LS10050-003NF-E:B
B
ECN 15-0292
Fire Alarm & Emergency Communication System Limitations
While a life safety system may lower insurance rates, it is not a substitute for life and property insurance!
An automatic fire alarm system—typically made up of smoke (caused by escaping gas, improper storage of flammable materi-
detectors, heat detectors, manual pull stations, audible warning als, etc.).
devices, and a fire alarm control panel (FACP) with remote notifi- Heat detectors do not sense particles of combustion and alarm
cation capability—can provide early warning of a developing fire. only when heat on their sensors increases at a predetermined
Such a system, however, does not assure protection against rate or reaches a predetermined level. Rate-of-rise heat detec-
property damage or loss of life resulting from a fire. tors may be subject to reduced sensitivity over time. For this rea-
An emergency communication system—typically made up of son, the rate-of-rise feature of each detector should be tested at
an automatic fire alarm system (as described above) and a life least once per year by a qualified fire protection specialist. Heat
safety communication system that may include an autonomous detectors are designed to protect property, not life.
control unit (ACU), local operating console (LOC), voice commu- IMPORTANT! Smoke detectors must be installed in the same
nication, and other various interoperable communication meth- room as the control panel and in rooms used by the system for
ods—can broadcast a mass notification message. Such a the connection of alarm transmission wiring, communications,
system, however, does not assure protection against property signaling, and/or power. If detectors are not so located, a devel-
damage or loss of life resulting from a fire or life safety event. oping fire may damage the alarm system, compromising its abil-
The Manufacturer recommends that smoke and/or heat ity to report a fire.
detectors be located throughout a protected premises following Audible warning devices such as bells, horns, strobes,
the recommendations of the National Fire Protection Association speakers and displays may not alert people if these devices
Standard 72 (NFPA 72), manufacturer's recommendations, State are located on the other side of closed or partly open doors or
and local codes, and the recommendations contained in the are located on another floor of a building. Any warning device
Guide for Proper Use of System Smoke Detectors, which is may fail to alert people with a disability or those who have
made available at no charge to all installing dealers. This recently consumed drugs, alcohol, or medication. Please note
document can be found at http://www.systemsensor.com/ that:
appguides/. A study by the Federal Emergency Management • An emergency communication system may take priority over
Agency (an agency of the United States government) indicated a fire alarm system in the event of a life safety emergency.
that smoke detectors may not go off in as many as 35% of all
fires. While fire alarm systems are designed to provide early • Voice messaging systems must be designed to meet intelligi-
warning against fire, they do not guarantee warning or protection bility requirements as defined by NFPA, local codes, and
against fire. A fire alarm system may not provide timely or Authorities Having Jurisdiction (AHJ).
adequate warning, or simply may not function, for a variety of • Language and instructional requirements must be clearly dis-
reasons: seminated on any local displays.
Smoke detectors may not sense fire where smoke cannot • Strobes can, under certain circumstances, cause seizures in
reach the detectors such as in chimneys, in or behind walls, on people with conditions such as epilepsy.
roofs, or on the other side of closed doors. Smoke detectors also • Studies have shown that certain people, even when they hear
may not sense a fire on another level or floor of a building. A sec- a fire alarm signal, do not respond to or comprehend the
ond-floor detector, for example, may not sense a first-floor or meaning of the signal. Audible devices, such as horns and
basement fire. bells, can have different tonal patterns and frequencies. It is
Particles of combustion or “smoke” from a developing fire the property owner's responsibility to conduct fire drills and
may not reach the sensing chambers of smoke detectors other training exercises to make people aware of fire alarm
because: signals and instruct them on the proper reaction to alarm sig-
• Barriers such as closed or partially closed doors, walls, chim- nals.
neys, even wet or humid areas may inhibit particle or smoke • In rare instances, the sounding of a warning device can cause
flow. temporary or permanent hearing loss.
• Smoke particles may become “cold,” stratify, and not reach A life safety system will not operate without any electrical
the ceiling or upper walls where detectors are located. power. If AC power fails, the system will operate from standby
• Smoke particles may be blown away from detectors by air batteries only for a specified time and only if the batteries have
outlets, such as air conditioning vents. been properly maintained and replaced regularly.
• Smoke particles may be drawn into air returns before reach- Equipment used in the system may not be technically compat-
ing the detector. ible with the control panel. It is essential to use only equipment
listed for service with your control panel.
The amount of “smoke” present may be insufficient to alarm
smoke detectors. Smoke detectors are designed to alarm at var- Telephone lines needed to transmit alarm signals from a prem-
ious levels of smoke density. If such density levels are not cre- ises to a central monitoring station may be out of service or tem-
ated by a developing fire at the location of detectors, the porarily disabled. For added protection against telephone line
detectors will not go into alarm. failure, backup radio transmission systems are recommended.
Smoke detectors, even when working properly, have sensing The most common cause of life safety system malfunction is
limitations. Detectors that have photoelectronic sensing cham- inadequate maintenance. To keep the entire life safety system in
bers tend to detect smoldering fires better than flaming fires, excellent working order, ongoing maintenance is required per the
which have little visible smoke. Detectors that have ionizing-type manufacturer's recommendations, and UL and NFPA standards.
sensing chambers tend to detect fast-flaming fires better than At a minimum, the requirements of NFPA 72 shall be followed.
smoldering fires. Because fires develop in different ways and are Environments with large amounts of dust, dirt, or high air velocity
often unpredictable in their growth, neither type of detector is require more frequent maintenance. A maintenance agreement
necessarily best and a given type of detector may not provide should be arranged through the local manufacturer's representa-
adequate warning of a fire. tive. Maintenance should be scheduled monthly or as required
by National and/or local fire codes and should be performed by
Smoke detectors cannot be expected to provide adequate warn- authorized professional life safety system installers only. Ade-
ing of fires caused by arson, children playing with matches quate written records of all inspections should be kept.
(especially in bedrooms), smoking in bed, and violent explosions Limit-D-1-2013
FCC Warning
WARNING: This equipment generates, uses, and can Canadian Requirements
radiate radio frequency energy and if not installed and This digital apparatus does not exceed the Class A limits
used in accordance with the instruction manual may for radiation noise emissions from digital apparatus set
cause interference to radio communications. It has been out in the Radio Interference Regulations of the Canadian
tested and found to comply with the limits for class A com- Department of Communications.
puting devices pursuant to Subpart B of Part 15 of FCC
Rules, which is designed to provide reasonable protection Le present appareil numerique n'emet pas de bruits radio-
against such interference when devices are operated in a electriques depassant les limites applicables aux appar-
commercial environment. Operation of this equipment in a eils numeriques de la classe A prescrites dans le
residential area is likely to cause interference, in which Reglement sur le brouillage radioelectrique edicte par le
case the user will be required to correct the interference at ministere des Communications du Canada.
his or her own expense.
HARSH™, NIS™, NOTI•FIRE•NET™, eVance™, and SWIFT™ are all trademarks; and Acclimate® Plus, FlashScan®, FAAST Fire Alarm Aspiration
Sensing Technology®, Intelligent FAAST®, NOTIFIER®, ONYX®, ONYXWorks®, VeriFire®, and VIEW® are all registered trademarks of Honeywell
International Inc.
Microsoft® and Windows® are registered trademarks of the Microsoft Corporation.
The Chrome™ and Google™ are trademarks of Google Inc.
© 2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
Documentation Feedback
Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions
about our on-line help or manuals, please e-mail us at FireSystems.TechPubs@honeywell.com.
On-Line Help – Please include the following information:
• Product name and version number (if applicable)
• Topic title
• The content you think should be corrected/improved
• Detailed suggestions for correction/improvement
Documents – Please include the following information:
• Document part number and title
• Page number and paragraph
• The content you think should be corrected/improved
• Detailed suggestions for correction/improvement
Please Note: If you have any technical issues, please contact Technical Services.
Manual Usage
This manual is written with the understanding that the user has been trained in the proper operations and services for
this product. The information provided in this manual is intended to assist the user by describing the configurations
and how they affect operations.
1.1 Operation
ONYXWorks Lite monitors building and life-safety systems and annunciates events (status change signals)
that are received from the attached network(s). It functions as a Protected Premises Control Unit. Multiple
user accounts are supported with monitoring and control permissions configured individually for each of the
user accounts.
ONYXWorks Lite supports one gateway with up to four nodes.
ONYXWorks Lite is hereinafter referred to as “the workstation”.
1.2 Functionality
1.2.1 System Functions
The workstation provides the following major functions:
• Displays events by priority. New events are displayed in the list based upon their event type priority.
• Displays acknowledged and new events in separate lists.
• Visual and audible annunciation of events.
• Maintains a history of life safety events.
• Monitors the communications path between workstation and gateway.
• Annunciates a trouble event when communications with gateway is lost.
• Displays device location information.
• Acts as a time server for gateways on the life safety network.
Devices 100,000
Macros 100
NavIcons 1000
1.5 IP Requirements
1.5.1 IP Port Settings
The following IP ports must be available to the workstation:
1.5.2 IP Restrictions
The following restrictions apply:
• Must have a static IP address. DHCP is not supported.
• Multiple IP Addresses are not supported, either due to multiple enabled network adapters or due to a
multi-homed adapter.
2.2.2 Browser
Google® Chrome™ must be installed and set as default browser.
Improper installation, maintenance, and lack of routine testing could result in system malfunction.
Testing and maintenance shall be performed in accordance with the Testing and Maintenance section of
NFPA-72.
Gateway Board
Battery
Remove
! Insulating Strip
Edge Connector
3.2 Connections
3.2.1 Connecting to the PC COMM Port
PC COMM
Port
EIA-232
Connector
To PC RS-232 Port
(See Figure 3.2)
To Network
TX A
RX A
TX B
RX B
Earth
To PC RS-232 Port
(See Figure 3.2) TX A
RX A
TX B
RX B
Normally Closed
To PC RS-232 Port
(See Figure 3.2.)
UPS SUPV 2 Connect to the Utility Failure connector on the UPS Inverter.
RS-232 2 Must use P/N 75557 cable shipped with the workstation.
Wire 2
Refer to the NOTI•FIRE•NET Manual (P/N 51584).
Fiber 2
Notes:
• Wire length resistance cannot exceed 15 ohms.
• Zero ohms to ground causes a ground fault.
SW100 TERMA
ON OFF
EF
OFF
ON
SW102 TERM B
ON OFF
SW100 TERM A
ON OFF
EF
OFF
ON
SW102 TERM B
ON OFF
SW200 A
LOW FULL
SW202
LOW FULL
SW200
LOW FULL
SW202
LOW FULL
3.5 Testing/Maintenance
Testing and maintenance should be performed according to the Testing and Maintenance section of
NFPA-72.
Navigation Tree:
Additional Properties (see 4.5)
Click to View
Node List (see 4.6)
Sub-items
Node Table Displays a window containing software version information for all monitored
nodes.
Connected Displays a window containing IP address and description information for clients
Clients connected to the PC NFN Gateway.
Tools Set Device Displays a dialog box allowing the user to change the current password.
Password
• Passwords are case sensitive.
• Alpha and numeric characters are supported.
• One character minimum and 8 characters maximum.
Auto Detect Select to have the gateway automatically detect all connected nodes.
Nodes
Web Portal Commission Web Selecting this option causes the web portal to request the point information
Portal from the FACP(s) to update the information on the eVance server. Refer to 4.7,
"Web Portal Setup".
Unregister Web Used prior to removing the PC NFN Gateway from the FACP connection.
Portal
Help Legal Displays legal information pertaining to the OW-LITE-NW and OW-LITE-NF.
Current Time/Date Displays the current date and time information after the gateway synchronizes the
clock with the SNTP server.
NFN Gateway Mode Select the mode in which the PC NFN Gateway is running.
Settings Settings (Default is Proprietary Receiving Unit)
Note: NCM Version does not appear when there is no NFN connection.
NCM Status Displays the NCM status, which can be: Piezo, UPS Failure, Network Fail Port A,
Bits Network Fail Port B, High Speed Audio, NCM Sniffer Mode Active, Local Connection
Limit Exceeded, or None.
Note: NCM Status Bits does not appear if when there is no NFN connection.
Fire Network Displays one of the following depending on the type of time synchronization used:
Time Policy
• Send time: The PC NFN Gateway sets the time on the NFN network.
• Unsynced: The PC NFN Gateway and NFN network are not synchronized with
each other.
Node Node Assign the NFN node number of the OW-LITE-NW and OW-LITE-NF.
Settings (Default is 240)
Send Time to Check the box to make the PC NFN Gateway send messages to each panel on the
Panels NFN network to synchronize the panel time to that of the PC NFN Gateway.
Style 7 • Select the checkbox for a Style 7 SLC (Signaling Line Circuit) configured NFN
network.
• Uncheck the checkbox for Style 4 SLC configured NFN network.
Web Portal Configures the Web Portal feature for use with eVance. Requires the eVance user ID, password, unique web portal
Setup name, and web portal description. Utilizes predefined customers and buildings from eVance. Refer to 4.7, "Web
Portal Setup".
Network Configuration Allows an Administrator to add or delete monitored networks to the system configuration.
Screen Objects Allows an Administrator to create and place informational objects on a graphics screen.
User Editor Allows an Administrator to set workstation user passwords and privileges.
Launch Database Editor Allows an Administrator to edit the workstation database in a spreadsheet format.
Allows a user to log in to the NFN system. The user can also log out of the system and
Login
log in as another user.
This section of the configuration tool allows a user to configure custom colors and sounds
Colors and Sounds for each event type. Refer to 5.3.5, "Color and Sound Configuration" for additional
information.
Allows an Administrator to select options as to how the workstation interface will operate.
System Options
Refer to 5.3.7, "System Options" for additional information.
Icon Set Select the desired icon set After selecting an icon set, the selection will not be displayed in the
for the workstation to use Icon Set drop-down list when the System Options dialog box is
for screen objects. reopened.
Time Server Settings IP Address If the IP address for the time server is the same IP address as this
PC, then the time server will run, else this PC will connect to the time
server to synchronize the clock on this PC.
• Add Node - Adds a node to the network. Select the node type from a list of choices and type in the IP address
of that node.
• Import Panel Database - Imports a Verifire Tools database. Any nodes and points that are in the database
will be autocreated on the network.
• Rename - Allows the user to rename the network. This is the equivalent of replacing the network alias in the
Properties window.
• Delete - Allows the user to delete the network. A confirmation prompt displays.
• Properties - Allows the user to change the network alias name and IP address of a gateway.
NOTE: The navigation tree may be a maximum of six levels deep including the Home screen.
The auto-creation process takes place each time a new point on the gateway reports an off-normal event to the
workstation. Point information is placed on a “holding screen” with a generic name (i.e., Screen 1) from which an
Administrator can relocate the point to its proper screen location using the Screen Objects window in the
configuration tool. Refer to the ONYXWorks Lite Configuration Tool Installation & Operation Manual (P/N 53508)
for additional information.
The auto-creation process creates a parent screen for the gateway reporting the event, a child screen for the node, and
a child screen under that for the points for that node (see Figure 5.2). Up to 64 point icons may be auto-created on a
workstation screen before another screen is created.
An asterisk (*) next to an entry indicates the entry and its name were auto-created and its position in the tree must be
redefined by an Administrator.
Event Code
Indicator Bars Network Gateway (Parent)
Node (Child)
The Administrator organizes the navigation tree in such a manner that it will aid the user with locating a specific
event in a campus (site) or building. The navigation tree can be arranged in a parent-child hierarchical relationship so
a user can, in a logical progression, “drill-down” from a site view to the floor plan of a building on that site. The tree
also shows at what level of the hierarchy an event is occurring. When events occur, boxes appear at the left side of the
tree in the color corresponding to the highest priority event (see Figure 5.2).
Reorder Screens Left-click on the screen label in the navigation tree and drag and drop it to the desired
hierarchical level. Dropping between screen levels places the screen between those
levels. After screens are moved, navicons maintain their link to the screen.
Cut and Paste Points Right-click the point and select Cut. Navigate to the desired screen location, right-click,
and select Paste.
Copy and Paste Points Right-click the point and select Copy. Navigate to the desired screen location, right-click,
and select Paste.
Delete Points Right-click the point and select Delete. Click Yes to the confirmation prompt.
Windows Update Check for updates but let me choose whether to download and
install them
Apply Saves the settings, but keeps the Options window open.
Event Label:
The event label is displayed in the event list when the point is in an off normal condition. The event label consists of a
combination of network, node, and point labels as described below.
Network Label Network Alias Display the user-defined description of the network.
Node Label Node Alias Display the user-defined description of the node.
Point Label Point Alias Display the user-defined description of the point.
Icon Label:
The icon label is displayed below the icon on the graphics screen. Icon label options are described below.
History Backup:
The external backup file is named with the date: YYYMMDD.HIS. History backup options are described below.
Check Boxes:
Options selectable via check boxes are described below.
Show only off normal True Display only icons of points that are off normal. If there are
devices no current events on the system, there will be no points
visible in the graphics display.
Auto-activate next True Once the first event in the New Events box is
event after acknowledged, the next event automatically activates. The
acknowledge workstation plays any media files linked to the event.
Automatically Navigate True Once an event reaches the top of the New Events box, the Recommended
On Event workstation navigates to the screen containing the device setting.
icon associated with the event.
Extract Descriptions True Use point descriptions as received from the FACP.
from Panel
False Use point descriptions as defined by the configuration tool
and discard point descriptions received from the FACP.
Shut Down PC on True Automatically shut down the computer hosting the
Workstation Shutdown workstation when the application is closed normally
(through File > Exit).
Suppress Automatic True Use this selection to hide automatically-created device When this setting is
Device Icon Creation icons from all navigation window displays. This selection enabled, the
also prevents the workstation from automatically navigating workstation will
to display off-normal events on devices with automatically continue to
created icons. autocreate icons
and screens, but
they will be hidden
in the workstation
graphics display as
well as the
navigation tree.
Show Navigation Icon True Display the user-defined text below the navigation icons.
Labels
False Hide the user-defined text located below the navigation
icons.
Omit Control Point On, True Control Point Activations, Point Activations, and Zone
Point Active, and Zone Activations will not be written to history.
on From History
False Store these events in history.
Security:
Inactivity Timeout 1-20 Length in minutes of no activity after which a user will be
(0-20) minutes automatically logged out.
User Responses: 8 user-defined Enter text that will be stored in history as responses to
responses. events. These are displayed when a user right-clicks on an
icon in the graphics screen.
Event Printer:
The event printer settings are available only if a Windows printer is connected to the workstation. Click the
fields below the headings to display the options.
User-defined Output Select an output format from the drop-down list. Refer to
Format 6.2.5, "Output Tab".
Sample Output:
Displays a sample of the output that will be printed using the settings selected above.
Buttons:
Add Format Click to display an output format name dialog box. Enter a
unique output format name and click Yes. The name is
displayed in the Output Formats field.
Delete Format Click to delete the output format name displayed in the Output
Formats list. Click Yes in response to the output format delete
confirmation prompt.
• If the output format is NOT used in a printer setup, the
selected output format is deleted.
• If the output format IS used in a printer setup, a message
displays indicating that the output format cannot be deleted.
In order to delete the format, the setups using the format
must be configured to use another output format or be
deleted.
Output Formats:
Output Formats Field Listed Outputs Click the down-arrow to display the available output formats
(added formats display automatically). The selected output is
configured/modified using the Available Fields/Format Fields
lists.
Available Fields • Action Lists the types of information that can be included in the
• Actual Time selected output. Add fields using any of the following methods:
• Card Facility Code
• Select one at a time - Double click on the entry or click on
• Card Number
an entry and then click on the right arrow button.
• Card Time
• Select several - Press and hold the Ctrl key while selecting
• Description
all desired fields. Then click the right arrow button.
• Network Alias
• Node Alias • Select all - Click the double right-arrow button.
• Point Alias Selecting “User Defined” activates the User Defined Messages
• Point Type field (see below).
• Status
• User Defined
Format Fields Selected Fields Displays the format fields configured for the output format
displayed in the Output Formats field. To remove fields from the
output, select the field name(s) from the list (see above) and use
the left arrows to remove from the output.
User Defined Messages: Active only when the “User Defined” output format is selected in the Format Fields list.
Click the field to the right of the event types to enter/modify the message associated with each type of event.The
“Other” message is used for other event types not included in the list.
1 2 3
4
5
6
10
11
12
1 Floor Plan Window The floor plan window usually displays a building floor plan as background and serves as
the primary source for visual feedback.The floor plan window’s title identifies which area of
an system that is currently being displayed. The location of an off-normal event in an system
which corresponds to the point’s (device) location in a building.
2 Graphic Elements Includes point icons (shown), navicons, and information labels that provide the user with
important system information. Refer to 7.4, "Auto-creation of Screens, Nodes, and Points"
for details.
3 Current User Displays the name of the current user. Left-click the label to change users.
View:
• Text Mode/Graphics Mode - If not grayed-out, click to toggle between text and graphic
display modes. Refer to 7.3.1, "Graphic Elements" for details.
• History - Opens the History Manager window.
• System - Opens the System Explorer window displaying a Windows-type navigation
tree showing local system layout.
• Search for Device -Opens the System Explorer window where the user can search for
a particular device on the system. Click on the device label displays detailed information
about the device.
• Armed/Disarmed Points - Displays a list of all points with their control profile, status,
and description.
• Background Activations - Displays a list of non-event point activations occurring in
the background. Used for informational/diagnostic purposes.
• Walk Test Points - Displays a list of points currently being tested in walk test mode
showing time/date, node label, type, network, status, and description.
Configure:
• Launch Configuration Tool - Opens the workstation configuration tool.
• Control Profiles - Opens the Control Profile Configuration Window.
• Monitoring Profiles - Opens the Monitoring Profile Configuration Window.
• Options - Opens a window that allows the user to configure local workstation settings.
• Backup and Clear History Database - Backs up and clears system history per the
history settings made on the General Tab.
Help:
• About - Click to display system software application information.
5 Tool Bar Previous Screen – Displays the floor plan that was viewed before the currently
displayed floor plan.
Next Screen – Displays the next floor plan below the current floor plan in the navigation
tree hierarchy.
Up One Level – Displays the next floor plan above the current floor plan in the
navigation tree hierarchy.
Print Current Screen – Prints the floor plan display to the currently selected printer.
Zoom In One Level – Increases the zoom of the floor plan display by 50% (ranges from
100% to 3700%).
Zoom Out One Level – Decreases the zoom of the floor plan display by 50% (ranges
from 100% to 3700%).
Show Floor Plan – Brings the floor plan display to the foreground, replacing any other
open dialogs.
7 Overview Window Displays the user’s location on the currently displayed workstation floor plan. A red
rectangle indicates the area currently being viewed. The red rectangle can be clicked and
dragged for repositioning the viewing area. This window is helpful when a zoom-in scale is
selected for the workstation floor plan. The overview window does not display the graphic
elements within it.
8 Navigation Tree Displays the NFN system in a structured hierarchy form similar to Microsoft’s Windows
Explorer. Refer to.7.3.2, "Navigation Tree".
9 New Events Pane Displays list of newly reported events on the network. Events remain on the list until they
have been acknowledged at the workstation. Events acknowledged at the fire panel remain
on this list followed by an “Acked” notation until acknowledged at the workstation. Refer to
7.3.3, "New Events Pane".
10 Acknowledged Events Displays a list of events acknowledged by the current user. Events remain on this list until
Pane the event is cleared.
11 Alarm Summary Pane Displays a running total of new and acknowledged events by type and order of priority. This
pane (hidden by default) is revealed by clicking on the up-arrow () adjacent to the Alarm
Summary title.
12 Event Summary Icons Click an icon to display a list of all the points currently in that state. Hover over the icon to
displays its label. Click the Print button ( ) to print alarm summaries. Refer to 7.3.4,
"Event Summary Icons".
7.3.1.2 Navicons
Navicons represent a method to navigate between workstation floor plan areas to find points or an event. Each
workstation floor plan area (parent) has one navicon that hyperlinks to each of its respective subordinate (child
screen) workstation floor plan areas (refer to the Navigation Tree hierarchy). Navicons change color to match the
off-normal event that is reported to the workstation. They are used to locate an event on parent or child screen; follow
the same colored navicon to find an event.
Command Description
Enter User Response Allows the user to select from a list of default or user-created responses. These
options provide the user the means to report various conditions and operations
related to a node/point. Default responses are as follows:
• Dispatched Personnel To Investigate
• Response Personnel on Scene
• Device Undergoing Test
• Device Testing Completed
• Contacted System Contractor
• Faulty Device
• Replaced Device
• Preventative Maintenance
History Of Device Only displays the history information in the History Manager window for the
selected node/point.
Linked Media Accesses any media that has been created and then assigned to the node/point.
Several types of media files may be linked to the node/point. One of each type can
be used.
• A text file to give specific information or instructions to the User (.TXT).
• A raster image type graphic can be linked (.BMP).
• A sound file may be linked giving audible information or instructions (.WAV).
• A video file may be linked (.AVI).
5
6
1 Window Title Describes the hierarchy levels displayed in the floor plan window.
3 Level Indicator Box Click “–” to collapse the level and its child screens.
4 Node Label Double-click to display the nodes devices location on the floor plan.
5 Level Indicator Box Click “+” to expand the level and view its child screens.
6 Pane Boundary Click, hold, and drag to change the pane size.
1 2 3
Item Description
Compact & Repair System Data This operation recovers dead space in the database, and reconstructs the index file.
CAUTION: To avoid data loss, do not perform this operation unless instructed to do so
by Technical Services.
Backup System Data Upon initiating this procedure, the user must select or create a folder (C:\Facilities
Monitoring 3.0\Backup is the default) and a “.dat” file that is used to identify the backup.
In most situations, it is most practical to back up the fire system database to the default
folder, using the same “.dat” file, after each editing session and then archive to a CD.
The workstation has a CD-RW drive.
CAUTION: If a second backup file is saved to an existing backup folder, both “.dat” files
remain, but the newer backup overwrites the data for the existing one. Do not save
backup system data to a folder which contains existing backup data that needs to be
saved.
Restore System Data This procedure is only available when all fire system applications, except PC Monitor,
are shut down.
This workstation command provides the Administrator with the option to restore a
database created with the Backup System Data command. The operation prompts the
user to select the location and folder in which the system data is to be stored.
Hide Column Temporarily hides the selected data column. The column itself is not deleted, only hidden.
Select Columns to Show Opens a dialog box that allows the user to select the columns that are displayed.
Show All Columns Removes all previously applied column data filters so that all columns display.
Resize Column Resizes the width of the selected column such that any hidden text is displayed.
Resize All Columns Resizes the width of all displayed columns such that any hidden text is displayed.
Sort Ascending/Descending Toggles between sorting the column data in ascending or descending order (numeric or
alphabetical).
Filter By Selection Allows the Administrator to display all records according to the event and column that was
right-clicked on.
Filter Excluding Selection Allows the Administrator to exclude displaying all records according to the event and the
column that was right-clicked on.
Filter For Displays a dialog box which allows the Administrator to filter for a specific word or phrase
using keywords and/or the wild card character (%).
Clear All Filters Allows the Administrator to return the History Manager window to the factory default filters.
Once this option has been chosen, all filters are lost unless they were saved using the “Save
Current Query” command.
Show If Greater Than Or Equal To Only displays when time-related data in a row is selected. Allows event filtering by the data in
the Received Time Local column. Only events occurring at the same time and after the
selected event are displayed.
Show If Less Than Or Equal To Only displays when time-related data in a row is selected. Allows event filtering by the data in
the Received Time Local column. Only events occurring at the same time and before the
selected event are displayed.
Installation Name This is typically a default site name. It is not recommended, but the name can be changed by
typing a new name into the field.
Registered This is typically a default site name. It is not recommended, but the name can be changed by
typing a new entry into the field.
Node License Shows how many node licenses are included with the current key configuration.
Serial # Displays the serial number of the USB key (different from the authorization code).
9.1 Overview
An example system architecture is described in the figure below.
ONYXWorks Lite
with PC Gateway
NFN Network
Warn-HL-08-2009.fm
www.notifier.com