Sei sulla pagina 1di 8

Servicios Generales

SEGINCA
SEGINCA de Inspecciones, C.A.

ULTRASONIC UNIT CERTIFICATION (Decibel dB Accuracy Procedure)


ULTRASONIC UNIT: Model:USN -50L Serial No.:00CVJ6 Fabricant.:KRAUTKRAMER

SEARCH UNIT: Size: 19 x19 mm Type: GAMMA Frequency: 2,25 Mhz

CALIBRATION Date: 20/10/2005 Interval: 2 Meses Method: AWS D1.5 Par. 6.22.2

TABULATION CHART
a b c d e
No dB Reading % Scale Corrected dB Error Collective
Reading dB Error
1 6 72 7.3 -1.3 -1,7
2 12 84 12.0 0.0 -0,4
3 18 82 18.2 -0.2 -0,4
4 24 82 24.2 -0.2 -0,2
5 30 84 30.0 0.0 0,0
6 36 84 36.0 0.0 0,0
7 42 84 42.0 0.0 0,0
8 48 84 48.0 0.0 0,0
9 54 82 54.2 -0.2 -0,2
10 60 86 59.8 0.2 0,0
11 66 85 65.9 0.1 +0,1

Accuracy requiered ninimun allowable range is : 60 dB %. % (Average) 84 %

Equiment is: Acceptble X No Acceptable Recalibration Due Date

Total qualified range 6 dB to 66 dB = 60 dB Total error 1.8 dB

Calibrated by Efraín Ortíz Barreto Level: II Location: Puerto Ordaz


82
84
84
84
84

418.0
418,0/5:83,6
Servicios Generales
SEGINCA
SEGINCA de Inspecciones, C.A.

ULTRASONIC UNIT CERTIFICATION (Decibel dB Accuracy Procedure)


ULTRASONIC UNIT: Model:USN -50L Serial No.:00CVJ6 Fabricant.:KRAUTKRAMER

SEARCH UNIT: Size: 19 x19 mm Type: GAMMA Frequency: 2,25 Mhz

CALIBRATION Date: 20/10/2005 Interval: 2 Meses Method: AWS D1.5 Par. 6.22.2

TABULATION CHART
a b c d e
No dB Reading % Scale Corrected dB Error Collective
Reading dB Error
1 6 69 7.0 -1.0 -0.6
2 12 75 12.2 -0.2 -0.5
3 18 75 18.2 -0.2 -0.3
4 24 75 24.2 -0.2 -0,1
5 30 77 30.0 0.0 +0.1
6 36 77 36.0 0.0 +0.1
7 42 77 42.0 0.0 +0.1
8 48 78 47.9 0.1 +0.1
9 54 77 54.0 0.0 0.0
10 60 78 59.9 0.1 +0.1
11 66 79 65.8 0.2 +0.3
12 72 80 71.7 0.3 +0.6

Accuracy requiered ninimun allowable range is : 60 dB %. % (Average) 77 %

Equiment is: Acceptble X No Acceptable Recalibration Due Date

Total qualified range 6 dB to 72 dB = 66 dB Total error 1.2 dB

Calibrated by Efraín Ortíz Barreto Level: II Location: Puerto Ordaz


75
77
77
77
78
77
461.0
461,0/6:76,83
Servicios Generales
SEGINCA
SEGINCA de Inspecciones, C.A.

ULTRASONIC UNIT CERTIFICATION (Decibel dB Accuracy Procedure)


ULTRASONIC UNIT: Model:USN -50L Serial No.:00CVJ6 Fabricant.:KRAUTKRAMER

SEARCH UNIT: Size: 19 x19 mm Type: GAMMA Frequency: 2,25 Mhz

CALIBRATION Date: 20/10/2005 Interval: 2 Meses Method: AWS D1.5 Par. 6.22.2

TABULATION CHART
a b c d e
No dB Reading % Scale Corrected dB Error Collective
Reading dB Error
1 6 78 6.2 -0.2 -0.6
2 12 80 12.0 0.0 -0.4
3 18 80 18.0 0.0 -0.4
4 24 78 24.2 -0.2 -0.4
5 30 79 30.1 -0.1 -0.2
6 36 79 36.1 -0.1 -0.1
7 42 80 42.0 0.0 0.0
8 48 81 47.9 0.1 +0.1
9 54 82 53.8 0.2 +0.3
10 60 82 59.8 0.2 +0.5
11 66 80 66.0 0.0 +0.5
12 72 84 71.6 0.4 +0.9

Accuracy requiered ninimun allowable range is : 60 dB %. % (Average) 80 %

Equiment is: Acceptble X No Acceptable Recalibration Due Date

Total qualified range 6 dB to 72 dB = 66 dB Total error 1.5 dB

Calibrated by Efraín Ortíz Barreto Level: II Location: Puerto Ordaz


78.0
79.0
79.0
80.0
81.0
82.0
479.0
479,0/6:79,83
Servicios Generales
SEGINCA
SEGINCA de Inspecciones, C.A.

ULTRASONIC UNIT CERTIFICATION (Decibel dB Accuracy Procedure)


ULTRASONIC UNIT: Model:USN -50L Serial No.:00CVJ6 Fabricant.:KRAUTKRAMER

SEARCH UNIT: Size: 19 x19 mm Type: GAMMA Frequency: 2,25 Mhz

CALIBRATION Date: 20/10/2005 Interval: 2 Meses Method: AWS D1.5 Par. 6.22.2

TABULATION CHART
a b c d e
No dB Reading % Scale Corrected dB Error Collective
Reading dB Error
1 6 80 6.0 0.0 -0.4
2 12 77 12.3 -0.3 -0.4
3 18 80 18.0 0.0 -0.1
4 24 79 24.1 -0.1 -0.1
5 30 80 30.0 0.0 0.0
6 36 80 36.0 0.0 0.0
7 42 77 42.3 -0.3 -0.3
8 48 82 47.8 0.2 -0.1
9 54 82 53.8 0.2 +0.1
10 60 82 59.8 0.2 +0.3
11 66 81 65.9 0.1 +0.4
12 72 80 72.0 0.0 +0.4

Accuracy requiered ninimun allowable range is : 60 dB %. % (Average) 80 %

Equiment is: Acceptble X No Acceptable Recalibration Due Date

Total qualified range 6 dB to 72 dB = 66 dB Total error 0.8 dB

Calibrated by Efraín Ortíz Barreto Level: II Location: Puerto Ordaz