Sei sulla pagina 1di 28

CALCULOS DE UN INTERCAMBIADOR DE CALOR

Fluido frio Agua


Datos del Intercambiador Fluido Caliente Ciclohexanol
UD 500
Do (") 0.75 Ciclohexanol
Do (Ft) 0.0625 W (Kg/h) 40000
Di (") 0.48 W (lb/h) 88184
Di (Ft) 0.04 Cp 0.5851
Ds (inch) 23.25 T1 (°F) 266
Ds (ft) 1.9375 T2 (°F) 176
Arreglo Δ μ 23.476
Pitch (inch) 1 Cp 0.5851
Pitch (ft) 0.083333333 k 0.06991506
Nt 352 f 5.04
Pasos de tubo 4 ρ 60.06
Pasos de coraza 2
Le (ft) 15
Baffles Espaciado (") 6
Baffles Corte (%) 25
g (ft/seg^2) 32.2

Q Q = W*Cp*ΔT
4.6437.E+06

w w = Q*Cp / ΔT
171988.19

MLDT
118.73

R
3.33

S
0.15
FT

0.96
𝐴=𝑁𝑡 ∗"π"∗𝐿𝐷𝑜

𝑈_𝐷=𝑄/(𝐴∗∆T 1036.73
〖∗ F 〗 _T )
UD

51.84
C'=𝑃 - 𝐷𝑜
C'

0.02083
𝑃_𝑇=𝐶^′+𝐷_𝑖

PT

0.06083

aS (ft^2)

0.332
𝐺_𝑠=𝑚 ̇∕𝑎_𝑠
Gs

265803.64

𝐷_𝑒=(4[(0,5𝑃_𝑇 )(0,86𝑃_𝑇−0,5𝜋𝑑_0^2/4)])/
(𝜋𝑑_0^2/2)
De

1.00694874474

n 't n't = Nt / Numero de pasos

88
𝑎_𝑡 = n't⋅
at (ft^2) (𝜋𝐷_𝑖^2)/4
0.1106
Gt
𝐺_𝑡=𝑚 ̇_𝑡∕𝑎_𝑡
1555271.10
𝑉_𝑡=𝐺_𝑡/( 𝜌)

vt 25044.6231652
(Nc+1)
(Nc+1)=12𝐿/
( 𝐵)
30
Agua ORTEGA OCHOA WILFREDO
w (lb/h) 171988.19 SALCEDO PALACIOS LEANDR
Cp 0.5851 CASTILLA ANAYA EDWIN
t1 (°F) 86
t2 (°F) 113
μ 1.936
Cp 1
k 0.36521891
f 0.0432
ρ 62.1

Para los tubos

Pr =(𝐶_𝑝
Pr "* μ" )/"k" 5.300930338

〖 𝑅𝑒〗 _𝑡
Ret =(𝐷𝐺_𝑡)/𝜇
32133.70

jH
100
ℎ_0=(𝑗_𝐻∗𝑘)/𝐷_𝑒
((𝑐𝑝∗µ)/𝑘)^(1/3)∗ø_𝑠
ho
ℎ_𝑖=(𝑗_𝐻 𝑘)/𝐷 63.2406886
((𝐶𝑝·𝜇)/𝑘)^(1/3)
ℎ_𝑖=(𝑗_𝐻 𝑘)/𝐷
((𝐶𝑝·𝜇)/𝑘)^(1/3)

hi
1592.0033
ℎ_𝑖𝑜=ℎ_𝑖 𝐷_𝑖⁄𝐷_𝑜
hio
1018.882112
𝑈𝑐=(ℎ_𝑖𝑜∗ℎ_0)/
(ℎ_𝑖𝑜+ℎ_0 )
Uc

59.54481906
𝑅_𝑑=(𝑈_𝐶−
𝑈_𝐷)/(𝑈_𝐶·𝑈_𝐷 )
Rd

0.002495169
〖 Δ𝑃 〗 _𝑇=(𝑓𝐺_𝑡^2 𝐿𝑛)/
(5.22×10^10 𝐷_𝑖 𝑠𝜙_𝑡 )
ΔPT
20018.2195

〖 Δ𝑃 〗 _𝑠=(4𝑛𝑣^2
ΔPr 𝑠)/2𝑔 (62.5/144)

10145463.73

ΔPTt 〖 Δ𝑃 〗 _𝑇𝑡=
〖 Δ𝑃 〗 _𝑠 + 10165481.95
〖 Δ𝑃 〗 _𝑇
ORTEGA OCHOA WILFREDO
SALCEDO PALACIOS LEANDRO
CASTILLA ANAYA EDWIN

Para la coraza

Pr =(𝐶_𝑝
Pr "* μ" )/"k"
196.464218152713
𝑅𝑒=(𝐷_𝑒
𝐺_𝑠)/𝜇
Re
11401.03

jH
70
ℎ_0=(𝑗_𝐻∗𝑘)/𝐷_𝑒
((𝑐𝑝∗µ)/𝑘)^(1/3)∗ø_𝑠
ho
ℎ_𝑖=(𝑗_𝐻 𝑘)/𝐷 28.25460441758
((𝐶𝑝·𝜇)/𝑘)^(1/3)
ℎ_𝑖=(𝑗_𝐻 𝑘)/𝐷
((𝐶𝑝·𝜇)/𝑘)^(1/3)

hi
14.6843553297226
ℎ_𝑖𝑜=ℎ_𝑖 𝐷_𝑖⁄𝐷_𝑜
hio
14.6843553297226
𝑈𝑐=(ℎ_𝑖𝑜∗ℎ_0)/
(ℎ_𝑖𝑜+ℎ_0 )
Uc

9.66256875830714
𝑅_𝑑=(𝑈_𝐶−
𝑈_𝐷)/(𝑈_𝐶·𝑈_𝐷 )
Rd

-0.0842

〖 Δ𝑃 〗 _𝑆=(𝑓𝐺_𝑠^2
ΔPs 𝐷_𝑆
(𝑁_𝐶+1))/(5.22×10^10
𝐷_𝑒 𝑠𝜙_𝑡 ) 2625.102
DATOS DE DISEÑO
DATOS DE LA UNIDAD LADO DE LA CORAZA LADO DE LOS TUBOS
Fluido CICLOHEXANO AGUA
Flujo másico (lb/h) 88184 171988.19
Temperatura de entrada (°F) 266 86
Temperatura de salida (°F) 176 113
Densidad (lb/ft^3) 60.06 62.1
Capacidad calorífica (Btu/lb °F) 0.5851 1
Viscosidad (LB/ Ft h) 23.476 1.936

No. De pasos 2 4
caída de presión (psi) 20018.2195035738 2625.10232192289
Fouling factor 5.04 0.0432
Calor transferido(Btu/h) 4643681.256

Ud (Btu/h ft^2 °F) 51.84


Uc(Btu/h ft^2 °F) 59.5448190628674
LMDT (°F) 118.73
CONSTRUCCIÓN
CONFIGURACIÓN DE LA UNIDAD arreglo triangular "Fixed tubos"
PITCH (") 1 N't
OD 6 n't
DIAMETRO DE LA CORAZA (") 23.25 BWG
% DE OBSTRUCCIÓN DE LOS BAFFLES 25 LONGITUD (Ft)
Area transverdad (Ft^2) 1036.73
LADO DE LOS TUBOS
AGUA
171988.19
86
113
62.1
1
1.936

4
2625.10232192289
0.0432
1.256

4
0628674
73

"Fixed tubos"
352
88
16
15

Potrebbero piacerti anche