Title: Single line flow diagram of Fly ash pressure conveying system
NTPC doc no: 9661-162-PVM-L-003 (Sheet No. 1 of 2 & 2 of 2)
SL NO NTPC comments on R0 MBE response Resolution/ NTPC MBE response Resolution
comments on R1
1. Fly ash discharge line valve Sheet 1 of 2 detail This is nothing but
incorporated Z-This arrangement the arrangement of
Legend please is not acceptable distribution of air
in the ash
transporter vessel.
Also in our NTPC
Mouda project we
did the same.
2. Instrument air line The same has already been provided in Sheet 1 of 2 This two are the
1 No. PT & 1No. PG to be the same instrument air line at ESP Legend-is there any same valve one is
provided area (Refer approved NTPC DWG. difference between showing open
No.9661-162-PVM-L-002 R 01). Hence two. Pls clarify condition and the
the same is not required here. Black mark is
showing normally
closed condition.
3. Ash Transporter feeder Sheet 1 of 2-Detail Confirmed.
incorporated Y- This
Feeder nomenclature arrangement is not
acceptable. Both
valve to be open
from separate
solenoid
4. Fly ash discharge line Sheet 1 of 2-Notes- Single coil solenoid
Incorporated. as commented valve.
Discharge line nomenclature earlier solenoid
type/rating to be
indicated
5. From TAC to Ash discharge Sheet 1 of 2 TAC-as Incorporated.
pipe line Incorporated. commented earlier
legend to be
Valve Legend please provided
Title: Single line flow diagram of Fly ash pressure conveying system
NTPC doc no: 9661-162-PVM-L-003 (Sheet No. 1 of 2 & 2 of 2)
6. TAC Discharge pipe line Sheet 1 of 2 TAC- Incorporated.
Incorporated. legend
Kindly provide all three lines
are interconnected with
cylinder operated BF
7. TAC Discharge pipe line Isolation valve has been provided on Sheet 1 of 2 TAC- In the discharge
all compressors outlet, air receiver Isolation valve line of air receiver
Isolation valve outlet & interconnection line with we have already
standby compressor. Hence no provided an
additional isolation valve is required. isolation valve. One
more isolation
valve in the same
line is not
recommended. In
tender drawing
also have shown
one no. isolation
valve at the
discharge of Air
receiver. Hence the
same is not
required.
8. TAC Discharge pipe line Sheet 2 of 2 FA silo Incorporated.
Incorporated. blower-as per
As per tender drg. PG to be tender drg PT to be
provided (TYP) provided before
connection of
common standby
blower to record
correct value of
individual blowers
9. Cooling water supply /return
hdr. Incorporated.
Title: Single line flow diagram of Fly ash pressure conveying system
NTPC doc no: 9661-162-PVM-L-003 (Sheet No. 1 of 2 & 2 of 2)

As per tech spec PT to be


provided (typ)
10. TAC of Unit #2
Incorporated.
TAC Nomenclature
11. IA Supply to the Ash intake
valve: Incorporated.

Legend to be provided

12. IA Supply to the Ash intake The valve will be operated through
valve: single coil solenoid valve

Please clarify whether it is


double coil solenoid v/v, as -
this is not matching with l-
PVM-L-001
13. IA Supply to the fluidizing
pad of ash transmitter
feeder:
Incorporated.
This v/v to be operated with
the help of separate
solenoid. Please provide
separate solenoid for this
purpose.
14. TAC Supply to the Ash
discharge valve:
Incorporated.
This v/v shall be pneumatic
for remote operation.
Title: Single line flow diagram of Fly ash pressure conveying system
NTPC doc no: 9661-162-PVM-L-003 (Sheet No. 1 of 2 & 2 of 2)
15. Detail-C2:
Legend to be included
Incorporated.

SL NO NTPC comments on R0 MBE response Resolution


1 IA line
PT & PG to be provided in the Incorporated.
line
2 Ultrasonic type LT required as It is already accepted by NTPC vide
per tender drg. (TYP) drg. No. 9661-162-PVM-L-005 REV.1
that the LT above Silo is of Radder
type. As Radder type LT is more
effective here.
3 Fly ash discharge line
Incorporated.
Discharge line nomenclature
4 Kindly provide Target Box
Incorporated.
5 Kindly provide Cyl operated BF
Incorporated.
6 This is not acceptable. Kindly
provide Rotary feeder with Incorporated.
VFD (Typ)
7 Rotary feeder with VFD
Incorporated.
8 All equipment data and pipe Noted & confirmed
size in this drawing will be as
per approved sizing
calculation./
9 Main silo area drain sump
pump Incorporated.
Title: Single line flow diagram of Fly ash pressure conveying system
NTPC doc no: 9661-162-PVM-L-003 (Sheet No. 1 of 2 & 2 of 2)
Local level gauge to be
provided as per tender drg.
10 Open L.S to be provided as per
tender drg. (TYP) Incorporated.
11 As per tender drg. PT to be
provided before connection of Incorporated.
common standby pump to
differentiate the blowers.
12 All the TE to be provided with
TT Incorporated.
13 PT to be provided as per
tender drg. Incorporated.