Sei sulla pagina 1di 8

Related Product Versions and Deployment Guidelines

Related Product Versions

during the network design for the solution.


Select the product to deploy by referring to Table 1 

Table 1 Related product versions

Network Products Delivered or Component Remarks


Type

PS  Service assurance platform at the The SEQ Analyst analyzes data collected


(including central site: SEQ by probes, provides functions such as
LTE) Analyst V200R002C02 NPM, SQM, and CEM, and monitors the
 Probes at remote network status in real time.
sites: NetProbe3010 V200R001C02

CS  Service assurance platform at the  The SEQ Analyst-SPM is a


central site: SEQ component of the SEQ Analyst. It
Analyst V200R002C02 collects data from the signaling
 Probes at remote sites: SEQ plane.
Analyst-SPM V200R002C02;UPS V  The UPS is a subsystem of
200R002C02 the SEQ Analyst. It collects data
from the user plane.
 The UPS is deployed only when
user-plane data needs to be collected.
 When the UPS is deployed,
the SEQ Analyst-SPM must be
deployed.

Radio  Service assurance platform at the This product documentation does not
access central site: SEQ cover third-party probes.
network Analyst V200R002C02
(RAN)  Probes at remote sites: third-party
probes (ZT)

NGN  Service assurance platform at the Empirix XMS is a third-party product. It


central site: SEQ is not covered in this product
Analyst V200R002C02 documentation.
 Probes at remote sites: Empirix
XMS V100R400C01

Deployment Locations
Table 2 lists the recommended deployment locations for the relevant products or components of the solution. The descriptions of system installation and
deployment are all based on these recommended deployment locations. The actual deployment locations may vary.
Table 2 Deployment location of each product

Product or Recommended Deployment Location


Component

SEQ Analyst Carrier's central site

NetProbe3010 Carrier's remote site


NOTE:
 It is recommended to deploy the NetProbe3010 and the NEs from
which it collects data in the same equipment room.
 If the NEs from which a NetProbe3010 probe server collects data is
located at the central site, it is recommended to deploy
the NetProbe3010 web server and this probe server at the central site,
facilitating device maintenance and management.

SEQ Analyst- Carrier's remote site


SPM NOTE:
The O&M server, that is, the web server, is deployed at the central site.

UPS Carrier's remote site


NOTE:
The O&M server, that is, the web server, is deployed at the central site.

Configuring Data for Interworking Between Central and Remote Sites

describes how to configure data for interworking


The SEQ Analyst solution consists of central and remote sites. Table 3 

between the central and remote sites.

Table 3 Data for interworking between central and remote sites

Probe Type Interworking Description

PS + LTE  Service communication channels must be established between


the SEQ Analyst and the NetProbe3010 probe servers.
 If multiple NetProbe3010 systems are deployed at different remote
sites, O&M communication channels must be established between the
web server and the probe servers in each NetProbe3010 system.

CS  O&M communication channels must be established between the SEQ


Analyst-SPM web server and the SEQ Analyst-SPM probe servers.
 O&M communication channels must be established between the SEQ
Analyst web server and the UPS probe servers.
 Service communication channels must be established between
the SEQ Analyst and the UPS probe servers.

ZT RAN probes Service communication channels must be established between the SEQ


Table 3 Data for interworking between central and remote sites

Probe Type Interworking Description

Analyst and ZT RAN probes.

NGN probes Service communication channels must be established between the SEQ


Analyst and NGN probes.
Parent topic: Introduction to the Solution

we need to answer on the following questions:

Thank you to confirm the version of NetProbe3010, what is the number of this version V200R001C02
or V200R001C01?.

knowing that for V200R001C01, the data collection interfaces are Gn, Iu-PS, Gi, Gb, S1-U, and S11
and for monitoring other interface as S8/S1–MME/S6a interface traffic (Gbps) it is necessary the
added to the License Items for SEQ Analyst solution V200R001C02, and for the Capacity and
Performance for Number of CS subscribers the V200R001C01 is ≤ 20 million and the V200R001C02
is ≤ 50 million.

And thank you to confirm that this version can monitor other interface as UI CS interface, GI, Gr ... like
finding on this image below:

is that there is the possibility of monitoring the CS part (signaling plane and user plane)?

and what are the products delivered or component for this possibility?

thank you for giving us all the KPIs for the SMART PCC solution.

NetProbe3010
. describes the changes in the performance of NetProbe3010 V200R001C02 as compared
with NetProbe3010 V200R001C01
Table 1 Changes in performance

Indicator V200R001C01 V200R001C02

Data processing capability (Gbps) 10 12.5 (Gn interface only, average


packet length 620 bytes)

Signaling-plane raw data retention ≤7 ≤7


duration (days)
NOTE:
If subscriber number encryption is
enabled, the system does not store
signaling-plane raw data.

Data collection interfaces Gn, Iu-PS, Gi, Gb, Gn, Iu-PS, Gi, SGi, Gb, S1-U,
S1-U, and S11 S11, S6a, S5/S8, SGi, and S1-
MME

License Changes
New License

The control items S5/S8/S1–MME/S6a interface traffic (Gbps) are added to the License Items for SEQ Analyst
solution V200R001C02.

SEQ Analyst :

Capacity and Performance


Overview

As carriers' data communication networks expand rapidly, the Gn-interface traffic on these networks
has been increasing from 10 Gbit/s to 100 Gbit/s or even higher in recent years. To accommodate
such rapid growth, all subsystems of SEQ Analyst V200R002C02 must provide enhanced data
analysis and processing capabilities.

Key Measurement Entities

Table 1 lists the changes in key measurement entities in V200R002C02 compared with
V200R002C01.

Category Subcategory V200R002C02 V200R002C01

Maximum Number of CS subscribers ≤ 50 million ≤ 20 million


configuration NOTE:
The subscribers refer to the
voice subscribers and SMS
subscribers.

CS input traffic ≤ 2 Gbit/s ≤ 2 Gbit/s


Category Subcategory V200R002C02 V200R002C01

NOTE:
The traffic refers to the total
traffic of raw A, Iu, BICC,
MAP, and CAP signaling.

PS input traffic ≤ 100 Gbit/s ≤ 100 Gbit/s


NOTE:
The traffic includes 50%
3G traffic and 50% 2G
traffic.

Minimum Number of CS subscribers ≤ 2.3 million ≤ 2.3 million


configuration NOTE:
The subscribers refer to the
voice subscribers and SMS
subscribers.

CS input traffic ≤ 60 Mbit/s ≤ 60 Mbit/s

Number of PS subscribers ≤ 3 million ≤ 3 million

PS input traffic ≤ 11 Gbit/s ≤ 11 Gbit/s

System Maximum allowed number ≤ 100 ≤ 100


performance of concurrent operating
users/terminals

QoS monitoring refresh 5 minutes 5 minutes


interval

Number of user groups 2000 2000

Number of VVIPs 1000 100

VVIP counter refresh 1 minute 1 minute


interval

Maximum number of VAPs 300 300

Maximum number of VACs 100 50


(Poor Quality Cells)

VAP calculation period The VAP counters are The VAP counters are
calculated every day. The calculated every day. The
VAP report is generated by VAP report is generated by
week. week.

xDR available time 5 minutes 5 minutes


NOTE:
The time specifies the
duration after which xDRs
can be queried.

xDR query response delay ≤ 15s ≤ 15s


Category Subcategory V200R002C02 V200R002C01

KQI/KPI analysis period 15 minutes, 1hour, 1day 15 minutes, 1hour, 1day

Equipment alarm report ≤ 1s ≤ 1s


delay

Service alarm report delay ≤ 10s ≤ 10s

Storage Original signaling 7 days 7 days

PS xDRs 60 days 60 days

CS xDRs 30 days 30 days

Peak hours each day 10 hours 10 hours

Alarm data 365 days 365 days

15-minute data tables 7 days 7 days

1-hour data tables 60 days 60 days

Daily data tables 365 days 365 days


UMTS: Universal Mobile Telecommunications System HSPA: High Speed Packet Access

PCU: Packet Control Unit EPC: Evolved Packet Core

SEQ Analyst: "service, experience, and quality" analysis platform SPM: CS signaling-plane module

Brief description of some elements in Figure 1:

  indicates an interface between NEs, which is also the position where a probe is deployed.

  indicates a virtual probe platform at a remote site.

 Yellow icons, such as  , indicate service servers used in the SEQ Analyst solution. They perform functions such as signaling
data convergence, signaling decoding, and service data presenting.

Potrebbero piacerti anche