On Board, On Guard
Fireboy-Xintex
Fireboy-Xintex have been supplying the Marine Industry with Clean Agent Fire Sup-
pression systems for more than 35 years, benefitting from many world class builders
within our portfolio, this success is due an excellent design,engineering and customer
service focus.
In recent years our move into Superyacht and Commercial Marine projects and the
introduction of MED Approved Fire Suppression and Detection equipment has enabled
the provision of a variety of reliable, trouble-free fire detection, fire suppression and
gas detection systems for the marine & offshore industry.
Fireboy-Xintex systems are designed and supplied appropriate to the class of vessel/
project under the following guidelines, ISO 9094, RCD, CE, MCA and all IACS mem-
bers regulations.
Specialising in total flooding clean agent extinguishing systems utilising either 3M™
Novec™ 1230 fire protection fluid or HFC-227ea fire extinguishant, both of which are
approved by all IACS members.
From your required design concepts Fireboy-Xintex can produce all the required
documentation for Class Society Approval using the latest CAD software in both 2D
and 3D.
Fireboy-Xintex were the first company to pioneer the Marine ‘Electrical Release Panel’
for clean agent systems fully conforming to Msc.Circ. 848/1267 and has proved very
popular with Superyacht and ship builders alike. The Release panel is available for
single or multiple cylinder systems.
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
page 2
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Contents
page 3
www.fireboy-xintex.co.uk
PLEASURE C
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Coupled to ‘Orbis’ Marine Approved Detection devices from Apollo, users can be confident that this low cost
option will give many years of trouble free protection.
Measuring just 66mm x 66mm the detection panels can be mounted in the most convenient space avail-
able and with four different options available are suitable for many Pleasure Craft (ISO 9094, RCD) and
Small Commercial Vessels (MGN 280) under 24M
Specifications
Minimum (alarm current) 10mA
Operating voltage 9 - 30vdc
Maximum current per zone 320mA (including EOL)
Siren/Buzzer output 12vdc @ 800mA
Extinguisher Output Unit Supply vdc @ 500mA
Charged Input 10 to 30vdc
Supply voltage @ 12vdc Maximum sensors = 14 per zone (2K2 EOL)
Supply voltage @ 24vdc Maximum sensors = 8 per zone (5K6 EOL)
Dimensions:
Face 66mm x 66mm x 5mm
Depth Required 90mm
Hole Size 55mm
FR-1000
Single Zone
12/24V Supply
Max 14 Detection Devices 12V
Max 8 Detection Devices 24V
FR-2000
Dual Zone
Labelled ‘Engine Room’ & ‘Accom’ page 1
12/24V Supply
Max 14 Detection Devices per Zone 12V
Max 8 Detection Devices per Zone 24V EARTH
EARTH EARTH
FRA-1000
Single Zone
12/24V Supply
Devices connected as
Max 14 Detection Devices 12V above
Max 8 Detection Devices 24V
Electrical Extinguisher Activation
Electrical
Activation
Pressure monitor
FRA-2000
Dual Zone
12/24V Supply
Labelled ‘Engine Room’ & ‘Accom’
Max 14 Detection Devices 12V
Max 8 Detection Devices 24V
Press Both Buttons For 5 Seconds
Electrical Extinguisher Activation
page 4
E CRAFT &
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Conventional Detection
Systems
(for <24m vessels not requiring marine approvals)
For those applications requiring more than 2 Zones, the FR4000 and FR8000 Fire Detection unit are the
perfect choice, providing an intelligent networked solution, and utilising the same Apollo ‘ORBIS” Marine
approved detection devices. This 100mm x 100mm unit features an 8 line Blue backlit LCD display making
for easy reading in most
lighting conditions.
FR-8000
Master Control Unit
Features include:
Full indication from one central location on your boat.
Visual indication of Fire or Fault.
Audible indication of Fire or Fault.
Isolate any zone.
All zone names programmable e.g.
(Saloon) (Engine Room) (Upper Deck) (Master Cabin).
Blue Backlight
FR-100
Input module:
Zone controller which manages the sensors.
Features include:
8 separate zone inputs.
Output Relay’s x 2.
10 A resistive @ 24VDC.
Relay 1 & relay 2 close on Fire detection.
Relay 1 opens when alarm is muted.
Relay 2 opens when all zones are OK.
The FR-8000 has been developed to allow monitoring of up to 8 zones. Each zone can have up to 18 sensors
attached. It is a network system consisting of the FR-8000 Master Display Unit and one FR-100 Eight Zone
Inputs.
All devices are interconnected by a 2 wire network cable. The Master Display Unit (MDU) controls communica-
tion with all attached Input and Output units. The network cable can be up to 1000 meters in length.
The General Alarm Tone, or to give it’s correct title, SOLAS Tone 1a consists of 7 short blasts followed by one
long blast, indicating when sounded that ALL personnel should proceed to their muster points.
Product Code
94213
page 5
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com PLEASURE CRAFT & Modular Marine 12 Zone
+44 (0)845 389 9462
SMALL COMMERCIAL Cont.... Conventional Detection
System
(for <24m vessels not requiring marine approvals)
This stylish fire detection system will not look out of place on any of todays modern pleasure vessels, designed to give ultimate
protection at an affordable cost, but with the styling that merits inclusion on todays modern helm, and the satisfaction of knowing
the boat and it’s occupants are protected.
The detection module will accomodate any conventional type detectors but has been tested throughout using Apollo Marine
Approved Orbis devices. The detection module is also designed to be supplied separately for inclusion within a boats Alarm and
monitoring system, with either RS485, RS232 or Modbus protocol versions being available
WHEELHOUSE
GALLEY
SALOON
FWD DOUBLE CABIN
GUEST CORRIDOR
PORT TWIN CABIN
STBD DOUBLE CABIN
MASTER STATE ROOM
CREW CABIN
ENGINE ROOM
CARBON MONOXIDE
NOT USED
Features Technical
Up to 12 Zones reporting OK, Fault & Fire Construction - ABS
Fault & Fire output relays IP Rating Finish - IP65
Detection module available separately Colour - lid & box - Black
RS232, RS485 & Modbus protocols available.
Detection Module IP66
Colour - controls plate & labels - Black - fine texture
Display IP66 Front IP67 Back Power supply DC rating - 9-32Vdc 1.5A Amps
5 Tactile Buttons Fault contact rating - 30V DC 1 Amp
Internal Buzzer Alarm contact rating - 30V DC 1 Amp
Software Updates via email Detection zone EOL resistor - 4K7
High brightness QVGA (320 x 240 pixels) colour display.
Fully sunlight viewable and the unit is totally sealed.
Display Dimensions - 116mm x 166mm x 50mm
Operating Temperature - -40 to +70 Degrees Celcius
Storage Temperature - -40 to +80 Degrees Celcius
WHEELHOUSE
GALLEY
SALOON
FWD DOUBLE CABIN
GUEST CORRIDOR
PORT TWIN CABIN
STBD DOUBLE CABIN
MASTER STATE ROOM
CREW CABIN
ENGINE ROOM
CARBON MONOXIDE
NOT USED
page 6
GAS DETECTION
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Remote I/O
Available in screen sizes 4”, 7”, 10”, 12” & 15” FnIO - S
MOD
0 1 0 1
RxD
In gas detection, ‘Flammable gases or vapours’ is usually shortened to LEL which TxD
2 3 2 3
stands for ‘Lower Explosive Limit’ – the lowest concentration of a gas which can I/O
Analog GND 4 5
When the LEL is 0%, the atmosphere is free of combustible gas and when it is 100%
the gas is at it’s flammable limit. These percentages will differ from gas to gas,
For example, Gasoline has an LEL of 1.4%. Therefore, 100% of LEL is 14,000 ppm of
gasoline, 10% of LEL is 1,400 ppm of gasoline and 1% of LEL is 140 ppm of gasoline.
140 ppm of gasoline is the lowest amount of vapor that the LEL monitor can “see.”.
FnIO - S
MOD
0 1 0 1
RxD
2 3 2 3
TxD
Analog GND 4 5
I/O
Shield 6 7
RS485 DATA -
P Series
Reliable detection of flammable-explosive and toxic gases. Pellistor and Infrared sensors
employed for the flammable gas detection show excellent output linearity up to 100% LEL.
Electromechanical and Infrared sensors, employed for toxic gas and Oxygen detection show
excellent ppm and vol ranges.
PE Series
Reliable detection of flammable-explosive gases and offers cost effective solutions for many
applications in classified areas. Catalytic sensors employed for the flammable Gas detection
in PE series show excellent output linearity up to 100% LEL.
PC3 Series
Reliable detection of flammable-explosive and toxic gases. Optional P-3R relay card provides
three-level selectable alarm relay (Alarm 1 and Alarm 2) and FAULT outputs. Alarm levels can
be set to predefined values to connect detector to conventional fire control panels or individu-
ally manged to sirens or solenoid valves.
Sensor head and cable gland in PC3 Seies are ATEX certified. PC3 series can be used as CAT3
device and in Zone 2 applications with specially designed Cast alluminium Junction Box.
page 7
MARINE A
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Product Overview
The Marine & Offshore Fireboy Syncro ASM is a versatile range
Marine & Offshore of open protocol fire alarm control panels compatible with
existing Syncro fire alarm panel technology.
Two Loop Analogue
Addressable Control Hosting up to 126 Apollo fire detection devices and modules
per loop, The Fireboy Syncro ASM uses leading edge micropro-
Panel cessor based electronics to provide a flexible control system
with high reliability and integrity.
2 programmable sounder circuits With its large graphical display and ergonomic button and
indicator layout, the Fireboy Syncro ASM control panel is
5 programmable inputs simple and straightforward to understand for installers, com-
missioning engineers and end users alike.
3 programmable relays
3A power supply
Large graphic display Fireboy Syncro ASM Panels
Real time clock
Protocol Zones Loops Printer Size (mm)
Powerful, network wide cause and
effects
Apollo 16 2 No 385 x 310 x 90
Sensitivity adjustment and drift
compensation
Config. Features
Product Code
Comprehensive day/night mode facility
90900-B
Programmable one touch test mode Other languages
can be programmed upon completion of a simple
Powerful and versatile cause & effect
programming conversion form.
available option:
Cause & effect wizard including: Flush Mount Bezel Kit available product code: 90948
ï ï ï K
= Ñá
ê ÉÄçó J ñå áí ÉKÅ
ñç ã = =êÑá
ÉÄçóÉ ì ] Ñá
ê ÉÄçó J ñå áí ÉKÅ
ñç ã =q=Éä =MUQR=
W P UV= VQS O
page 8
APPROVED
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Technical
Construction - 1.2mm sheet steel
System Integration
Enclosure finish - BS 00 A 05 light grey textured
Mains voltage supply - 230V AC 50 or 60 Hz.(110V special request) The system has two serial ports on the front panel
Display - 8 lines of 40 characters graphic LCD
Mains supply fuse - 1.6A 250V board which are used for communication with exter-
Power supply DC rating - 24V 3 amps nal devices, such as a PC printer,modem or connec-
Aux 24V supply Fused at 500 milliamps
Battery (24 hour standby) - 7Ah 12V (2 per panel) (non-networked)
tion to an Alarm and Monitoring system.
Fault contact rating - 30V DC 1 amp
Fire contact rating - 30V DC 1 amp
Alarm contact rating - 30V DC 1 amp
Sounder output rating - Fused at 1 amp each
Detection loop - 400 milliamp output
Detector protocol - Apollo Discovery
Printer port - Serial RS232
Serial expansion port - Serial RS485
(Compatible with all Syncro I/O modules)
PC port - Serial RS232
Network connection - RS485 - Up to 64 panels via
fully fault tolerant optional network card
Remote Silence input (SIL) - Switched -ve
Remote fault input (FLT) - Switched -ve
Remote reset input (RES) - Switched -ve
Remote alert input (INT) - Switched -ve
Remote evacuate input (CNT) - Switched -ve
Download lead - Product Code: 95016
Configuration - Via Loop Explorer PC utility
MODBUS Interface
ASM Repeater Panels 94xxxx Vizulinx
Vizulinx supports Modbus®
over IP, with 1000 registers as
default. Additional 1000 point
Product Code registers are available by
licence upgrades, up to a
90931 Flush Mount maximum of 10000 points.
Size (mm)
310 x 240 x 40
VF0860-4M-FB - Elite RS
page 9
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com ‘Pacific’ panels are fully approved to European standards EN54-2 & 4,
Fire Detection and Alarm Systems– Control & Indicating Equipment & the
+44 (0)845 389 9462
Marine Equipment Directive.
1-4 Loop Analogue Addressable Fire Detection Panel
Fireboy’s latest Detection offering is specifically aimed at the Marine and Offshore environment, this
intelligent analogue addressable fire detection and alarm control panel is approved to EN 54 part 2
& 4, Lloyds Type Approval & MED compliant. Offered in two variants, the Pacific and the Pacific
Plus.
page 10
‘Ocean’ panels are fully approved to European standards EN54-2 & 4, www.fireboy-xintex.co.uk
www.fireboy-xintex.com
Fire Detection and Alarm Systems– Control & Indicating Equipment & the fireboyeu@fireboy-xintex.com
Fire & Fault VFCO relays, Fire & Fault switched negative outputs, class
change and an alert input are also included. Available in
Grey or Black
The fire zone Fire & Fault switched negative outputs, class change and
an alert input are also included.
CABINET
Technical
57mm 80mm
300mm
As standard the panels provide two monitored sounder circuits, Fire &
Fault VFCO relays, Fire &Fault switched negative outputs, class change
and an alert inputare also included.
The fire zone Fire & Fault switched negative outputs, class change and
an alert input are also included.
CABINET
60mm 85mm
Technical Available in
Grey or Black
page 12
Conventional
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Analogue
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Marine Devices
Ionisation Smoke Detector Optical Smoke Detector
The Analogue Marine Ionisation Detector uses a low The Analogue Marine Optical Smoke Detector
activity radioactive foil to detect fires by irradiating the works using the light scatter principle and is ideal
air in the smoke chamber and causing a current flow. If for applications where slow-burning or smoulder-
smoke enters the chamber, the current flow is reduced ing fires are likely.
leading to an alarm. Responds well to slow-burning, smouldering fires
Responds well to fast-burning, flaming fires Well suited for bedrooms and escape routes
Designed to operate in a variety of environments Unaffected by wind or atmospheric pressure
Remote test feature Remote test feature
Addressable models
are supplied with
Combined LED indica- E-Z fit connectors for
tor and front reset Minimal space quick and practical
mechanism required to detach installation of cables.
the front plate for
easy removal.
page 15
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
Loop Powered
Sounders & Beacons
Intelligent Open-Area Sounder Intelligent Open-Area Beacon
The Intelligent Open-Area Sounder has been designed for use in The Intelligent Open-Area Beacon has been developed for use in
open areas and can be connected to any Discovery system. situations where there is a risk that sounders will not be heard. It
is weatherproof and can be used outside.
Self-test fault monitoring
Choice of tones Self-test fault monitoring
Group addressing and synchronisation of alarm Weatherproof IP65
Weatherproof IP65 Group addressing
Comes with Isolating Base as standard Synchronisation of alarm
Loop powered Comes with Isolating Base as standard
Output is 100 dB(A) at 90º Loop powered
Ceiling Mounted
page 16
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
DIN-Rail Components
+44 (0)845 389 9462
& Accessories
DIN-rail Sounder Controller DIN-Rail Switch Monitor Plus
(8 Amperes) The Marine DIN-rail Switch Monior Plus is designed to
monitor the state of one or more single pole, volt free
The Marine DIN-rail Sounder Controller (8 Amperes) is used
contacts connected on a single pair of cables and to
to control the operation of a zone of externally powered
report the status to Apollo compatible analogue control
sounders and report their status to the control panel.
equipment.
Allows sounders to be operated continuously or be
Output for resetting a remote detector
pulsed, 1 second on, 1 second off
Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’
May be synchronised when in pulsed operation
Two visible LEDs
An opto-coupled input is provided to monitor the state of
Loop powered
the external power supply
Selectable alarm delay for monitoring flow switches
Sounders can be operated individually or in groups
90969 - Switch Monitor Plus
90968 - Sounder Controller
Galvanic Barrier
Product Code 90915
DIN-Rail Interface
Enclosures
DIN-Rail Interface Enclosures are available in two
sizes and can be used for housing Intrinsically Safe
(IS) barriers or DIN-Rail mounted Interfaces.
page 17
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
K
AN
BL
FT
LE
L
AL
N
O
TI
N
TE
IN
page 18
www.fireboy-xintex.co.uk
www.fireboy-xintex.com
fireboyeu@fireboy-xintex.com
K
AN
BL
FT
LE
L
AL
N
O
TI
N
TE
IN
page 19
Marine Fire Detection Systems
On Board, On Guard
10 Holton Road, Fire Suppression . Fire Detection . Gas Detection 0-379 Lake Michigan Drive NW
Holton Heath Trading Park, Grand Rapids
Poole, Dorset, BH16 6LT, Michigan 49534
United Kingdom. USA