Sei sulla pagina 1di 1

9705-C

HYDRIL SuPreme™ LX HANDLING PLUGS


Jan-06

Hydril SuPreme LX handling plugs are designed to protect threads, shoulders, and the seal of the connection
during running with slip type elevators. These handling plugs are a new design and can now also be used
with collar type elevators. The OD lifting shoulder of the SLX handling plug is approximately equal to the OD
of the API casing coupling for the applicable casing size, permitting it to be run through spiders and
elevators. The SLX handling plugs are rated consistent with API hoisting requirements and are drifted large
enough to provide protection to the box while running ID tools. These handling plugs also act as an
emergency catch when hanging in the slips.

Plug Flange Plug Part


OD Weight Range Flange OD Plug ID Weight Thickness Rating Number
in. lb/ft in. in. lbs. in. 1000 lbs
4.500 12.60 to 13.50 5.500 3.880 8 2 46 2005425
4.500 15.10 5.500 3.746 9 2 64 2005426
4.500 17.00 to 18.80 5.500 3.674 10 2 96 2005427
4.500 21.60 5.500 3.420 12 2 132 2005428
5.000 15.00 to 18.00 6.000 4.328 10 2 61 2005429
5.000 20.30 to 21.40 6.000 4.104 12 2 110 2005430
5.000 23.20 to 24.10 6.000 3.964 13 2 140 2005431
5.500 17.00 to 20.00 6.500 4.812 11 2 75 2005432
5.500 23.00 6.500 4.590 13 2 129 2005433
5.500 26.00 to 26.80 6.500 4.534 14 2 143 2005434
6.625 22.60 to 24.60 7.630 5.888 13 2 96 2005435
6.625 28.00 to 32.00 7.630 5.711 16 2 165 2005436
6.625 33.00 to 34.50 7.630 5.545 19 2 204 2005437
7.000 23.00 to 26.00 8.000 6.286 14 2 102 2005438
7.000 29.00 to 32.00 8.000 6.160 16 2 157 2005439
7.000 35.00 to 38.00 8.000 5.924 20 2 212 2005440
7.000 41.00 to 42.70 8.000 5.740 23 2 202 2005441
7.625 26.40 to 29.70 8.630 6.889 17 2¼ 118 2005442
7.625 33.70 to 39.00 8.630 6.685 21 2¼ 198 2005443
7.625 42.80 to 45.30 8.630 6.421 26 2¼ 232 2005444
7.625 47.10 8.630 6.295 29 2¼ 230 2005445
7.750 46.10 to 54.20 8.750 6.535 27 2¼ 206 2005446
8.625 36.00 to 40.00 9.660 7.745 23 2¼ 211 2005447
8.625 44.00 to 49.00 9.660 7.545 28 2¼ 273 2005448
8.625 52.00 to 54.00 9.660 7.355 32 2¼ 268 2005449
9.625 43.50 to 47.00 10.660 8.675 28 2¼ 274 2005450
9.625 53.50 to 58.40 10.660 8.520 31 2¼ 286 2005451
9.750-9.875 59.20 to 62.80 10.920 8.535 37 2¼ 305 2005452
10.000 66.95 to 68.42 11.000 8.539 39 2¼ 305 2005453
10.750 51.00 to 55.50 11.880 9.770 33 2¼ 336 2005454
10.750 60.70 to 65.70 11.880 9.580 38 2¼ 369 2005455
11.750 60.00 to 71.00 12.880 10.692 38 2¼ 397 2005456
11.875 71.80 13.000 10.670 43 2¼ 419 2005457
12.000-12.063 74.80 to 78.10 13.130 10.668 45 2¼ 380 2005458
13.375 68.00 to 77.00 14.500 12.305 45 2¼ 452 2005459
13.375 80.70 to 86.00 14.500 12.136 51 2¼ 442 2005460
13.500 81.40 14.750 12.291 49 2¼ 525 2005461
13.625 88.20 14.750 12.290 56 2¼ 448 2005462

To be able to pass over the box, collar-type elevators should have an ID bore approximately 0.5% larger
than the connection OD.