Field Replaceable Units

Hard Drive Replacement


Procedure
X2510/X4510/X6510/X8510/X10K and M160
Appliances
June 2017

DC000062 rev A01


Copyright Notice

© 2002 - 2017 Imperva, Inc. All Rights Reserved.


Follow this link to see the SecureSphere copyright notices and
certain open source license terms:
https://www.imperva.com/sign_in.asp?retURL=/articles/Reference/
SecureSphere-License-and-Copyright-Information
This document is for informational purposes only. Imperva, Inc.
makes no warranties, expressed or implied.
No part of this document may be used, disclosed, reproduced,
transmitted, transcribed, stored in a retrieval system, or translated
into any language in any form or by any means without the written
permission of Imperva, Inc. To obtain this permission, write to the
attention of Legal Department at the address below.
Information in this document is subject to change without notice
and does not represent a commitment on the part of Imperva, Inc.
The software described in this document is furnished under a
license agreement. The software may be used only in accordance
with the terms of this agreement.
This document contains proprietary and confidential information of
Imperva, Inc. This document is solely for the use of authorized
Imperva customers. The information furnished in this document is
believed to be accurate and reliable. However, no responsibility is
assumed by Imperva, Inc. for the use of this material.
TRADEMARK ATTRIBUTIONS
Imperva and SecureSphere are trademarks of Imperva, Inc.
All other brand and product names are trademarks or registered
trademarks of their respective owners.

SecureSphere Field Replaceable Units Hard Drive Replacement Procedure 2


Copyright Notice

PATENT INFORMATION
The software described in this document is covered by one or more
of the following patents: US Patent Nos. 7,640,235, 7,743,420,
7,752,662, 8,024,804, 8,051,484, 8,056,141, 8,135,948, 8,181,246,
8,392,963, 8,448,233, 8,453,255, 8,713,682, 8,752,208, 8,869,279
and 8,904,558, 8,973,142, 8,984,630, 8,997,232, 9,009,832,
9,027,136, 9,027,137, 9,128,941, 9,148,440, 9,148,446 and
9,401,927
Imperva Inc. General Information:
3400 Bridge Parkway, Suite 200 info@imperva.com
Redwood Shores, CA 94065 USA Websie:
http://www.imperva.com
Tel: +1 (650) 345-9000
DC000062 rev A01
Imperva-SecureSphere-FRU-Hard Drive Replacement Procedure -v1

SecureSphere Field Replaceable Units Hard Drive Replacement Procedure 3


Before You Begin

Before You Begin

Pay Attention: If you receive for a replacement


more than one HDD, you must replace all drives and
not just the faulty one.

Determine which of the disk drives has failed as follows:


1. Run the command
impctl platform storage raid adaptec arcconf
getconfig 1
2. Under the Logical device information section, review the
Logical device segment information section to determine the
faulty HDD.
For example:
-------------------------------------------
Logical device segment information
-------------------------------------------
Segment 0 :
Present (Controller:1,Connector:0,Device:0)
WD-WMC6N0E9DT2X
Segment 1 :
Failed/Missing
(Controller:1,Connector:0,Device:1)
WD-WMC6N0E46YU2
Segment 2 :
Present (Controller:1,Connector:0,Device:2)
WD-WMC6N0E1H94U

4 SecureSphere Field Replaceable Units Hard Drive Replacement Procedure


Replacement Disk Drive

For an appliance with two HDDs, Connector 0 and Device 0


means the upper HDD and Connector 0 and Device 1 means the
lower HDD.
For an appliance with three HDDs, Connector 0 and Device 0
means the upper left HDD, Connector 0 and Device 1 means the
lower left HDD and Connector 0 and Device 2 means the upper
right HDD.

Replacement Disk Drive

If one of the disk drive fails, you can replace it while the appliance is
running.

Obtaining a Replacement Disk Drive


To obtain a replacement disk drive, contact Imperva support.

Preparing the Appliance


The disk drives are hot-swappable. There is no need to power down
the appliance before replacing one of the disk drives.

SecureSphere Field Replaceable Units Hard Drive Replacement Procedure 5


Replacement Disk Drive

Removing a Disk Drive


Before removing a disk drive, determine which unit is not
functioning properly. Be sure you are removing the correct unit.
To remove a disk drive:
1. Push the drive tray’s latch to the left.
2. Swing the door open.

3. Pull the drive tray out.

6 SecureSphere Field Replaceable Units Hard Drive Replacement Procedure


Replacement Disk Drive

4. Remove the four screws on the bottom of the drive tray.

SecureSphere Field Replaceable Units Hard Drive Replacement Procedure 7


Replacement Disk Drive

5. Lift the the hard disk out of the tray.


6. Insert the replacement hard disk into the tray.
7. Secure the hard disk in the tray with the four screws that you
removed in step 4.

Installing a Disk Drive


To install a disk drive:
1. Slide the disk drive tray into the slot until you hear it click into
place.
2. Make sure the tray’s latch is fully closed.
3. The RAID re-build process begins after approximately one
minute, in the course of which, the contents of the two disks
are synchronized. This process may take several hours.
4. During the process, you can run the command
impctl platform storage raid adaptec arcconf
getconfig 1
to see the State of the disk, which should be Rebuilding (see
example below).
-------------------------------------------
Physical Device information
-------------------------------------------
Device #0
Device is a Hard drive
State
: Rebuilding
Supported
: Yes
Transfer Speed
: SATA 6.0 Gb/s
Reported Channel,Device(T:L)
: 0,0(0:0)

8 SecureSphere Field Replaceable Units Hard Drive Replacement Procedure


Replacement Disk Drive

Reported Location
: Connector 0, Device 0
Vendor
: WDC
Model
: WD2005FBYZ-01YCB
Firmware
: RR07
Serial number
: WD-WMC6N0E9DT2X
Size
: 1907729 MB
Write Cache
: Enabled (write-back)
FRU
: None
S.M.A.R.T.
: No
S.M.A.R.T. warnings
: 0
Power State
: Full rpm
Supported Power States
: Full rpm,Powered off,Reduced rpm
NCQ status
: Enabled

SecureSphere Field Replaceable Units Hard Drive Replacement Procedure 9


Replacement Disk Drive

5. Run the command


impctl platform storage raid adaptec arcconf
getstatus 1
to see the Status of the rebuild process (see example below).
Controllers found: 1
Logical device Task:
Logical device : 0
Task ID : 102
Current operation : Rebuild
Status : In
Progress
Priority : High
Percentage complete : 91

10 SecureSphere Field Replaceable Units Hard Drive Replacement Procedure


Replacement Disk Drive

6. When the rebuild process finishes run the command


impctl platform storage raid adaptec arcconf
getconfig 1
to see the Status of logical device of the disk, which should be
Optimal (see example below).
-------------------------------------------
Logical device information
-------------------------------------------
Logical device number 0
Logical device name
: raid 5 rr07
RAID level
: 5
Status of logical device
: Optimal
Size
: 3809270 MB
Stripe-unit size
: 256 KB
Read-cache mode
: Enabled
Write-cache mode
: Enabled (write-back)
Write-cache setting
: Enabled (write-back)
Partitioned
: Yes
Protected by Hot-Spare
: No
Bootable
: Yes

SecureSphere Field Replaceable Units Hard Drive Replacement Procedure 11


Replacement Disk Drive

Failed stripes
: No
Power settings
: Disabled

-------------------------------------------

12 SecureSphere Field Replaceable Units Hard Drive Replacement Procedure

Potrebbero piacerti anche