CONTACTORS

Series 3100 3100 3100 3100 3100 3100 3100 3186 3100

Number
of 1&2 1&2 3 3 4 4 3 3 3
Poles

FLA 20-35 40 20 -30 40 25-30 40 50 & 60 75 & 90 120


Rating

Arc Optional Standard Optional Standard Optional Standard Standard Standard Standard
Cover
Product Selection Guide

1/4” QC, 1/4” QC, 1/4” QC, 1/4” QC, 1/4” QC, 1/4” QC, 1/4” QC, 1/4” QC, 1/4” QC,
#10-32 #10-32 #10-32 #10-32 #10-32 #10-32 #1/4-20 #1/4-20 #1/4-20
Termination Screw or Screw or Screw or Screw or Screw or Screw or Screw or Screw or Screw or
Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug Box Lug

Agency
Approvals

Page
6 6 8 8 10 10 12 14 16
Number

TRANSFORMERS

Series 4000 4000 4000 4000 4000 4000 4000 4700 4700

VA
5,10, 40 & 50 60 & 75 10, 20, 30 40 & 50 60 & 75 20 & 40 60, 100, 60, 100,
20, 30 150 150
Rating

Wire Wire Wire Quick Quick Quick Wire Wire Quick


Termination Lead Lead Lead Connect Connect Connect Lead Lead Connect

Foot or Foot or Foot or Foot or Foot or Foot


Mounting Panel Panel Panel Panel Panel with Integral Plate Foot Foot
Circuit Breaker

Agency
Approvals
Page
Number 22 24 26 28 30 32 34 34 34

2
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
RELAYS

Series 9400 9100 38 57

Number
of 1 1 or 2 1 1 or 2
Poles

Contact SPNO, SPNC, SPNO, SPNC SPNO, SPNC,


Configuration SPDT, SPDT, NC SPDT,

Product Selection Guide


Termination 1 NO / 1 NC DPST, DPDT 1 NO / 1 NC

Agency
Approvals Quick Connects Quick Connects Quick Connects #6-32 Screw

Page
Number
38 40 42 37

Products Unlimited “999” Standard Program


Throughout the catalog there are references to the Products Unlimited "999" STANDARD PROGRAM. The last two or three
digits of a Products Unlimited part number are the customer identification number and indicate to the factory what modifica-
tions are required by the customer to that particular product. This modification can include a special lead length on a trans-
former, special terminations on a contactor, or any number of other modifications. We have found that most customers do
not require special modifications and would prefer to get a model that is readily available and made on a continuous basis.
The "999" items are identified at the top of each page making them easily accessible.

FEATURES OF STANDARD CONTACTORS FEATURES OF STANDARD TRANSFORMERS


Covers are provided on 30 FLA 3 pole contactors. Resettable Circuit Breakers are standard on all 75 VA versions.
On 40 FLA thru 120 FLA contactors, arc covers are standard. Wire lead models feature 18 AWG 12” leads with 1/2” strip.
Coils are taped and enclosed in the contactor housing on Quick Connect models feature .250 QC terminals.
model 98 units.
Coils are furnished with dual quick connects (no screws)
on model 98 contactors.
Pole markings of L1, L2, L3 and T1, T2, T3 are standard
on 30 FLA thru 120 FLA 3 pole units.

MINIMUM ORDER QUANTITIES


PRODUCT MODEL STANDARD “999” ITEMS CUSTOM ITEMS
Relays All 50 Pieces 200 Pieces
Contactors 1 & 2 Pole 50 Pieces 200 Pieces
3 Pole, 30 & 40 FLA 25 Pieces 200 Pieces
3 Pole, 50 & 60 FLA 10 Pieces 100 Pieces
3 Pole, 75 & 90 FLA 5 Pieces 50 Pieces
3 Pole, 120FLA 1 Piece 10 Pieces
Transformers All 50 Pieces 300 Pieces
*Minimum billing $300.00
3
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
The Model 98 Definite Purpose Contactor
At the heart of the contactor line is the
Industry Standard 3100 Series Model 98. This high
Mounting Plate performance contactor offers flexibility,
Easily accessible reliability and is designed to match
mounting holes.
numerous applications such as:
Motors
Coil Terminals Power Supplies
#6-32 screw and (1) .250 Food Service Equipment
Quick Connect or Dual .250 Compressors
quick connects(Will accept two
insulated quick connect terminals). Business Machines
Resistive Heating
Air Conditioning
Refrigeration Equipment
Welding
Coil
Double E Magnet Class B (1300C) Insulation
Assembly System.
Provides optimal Tape wound or molded construction,
performance with with wide range of voltages and
reduced power 50/60 Hz ratings.
consumption.
Movable Contacts
Heavy duty Silver Cadmium Oxide composition
Return Spring for long life.
Provides positive force to
open contacts when magnet Coil Dust Cover
is de-energized. Keeps dust and dirt away
from magnet and coil area.
Actuator
Molded from high arc resistant
polyester. Holds upper magnet, Stationary Terminal
movable contacts and contact One piece terminal design
springs in position. with integral dual .250 quick
connects. Meets NEMA
standard for spacing without
Snap-IIn Auxiliary insulated terminals.
Switch (optional)
1 SPDT or 2 SPDT
(shown) available. Also,
1NO & 1NC with 600 Base Assembly Exclusive Terminal Screw
VAC rating. High arc resistant Features: Hex, slotted,
polyester holds stationary phillips #10-32 screw or
terminals, positions actuator optional Sems screw with
and magnet / coil assembly. pressure plate.

Box Lug
4-14 Aluminum AWG box lug
standard on 40 FLA models.

Manual Test Button


Directly closes movable contacts
without energizing the coil.

4
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
Contactor Nomenclature
Part Numbering System:

3100 - 30 Q 10 999 CG

SERIES OPTION CODE


3100= 1, 2, 3 Pole - This letter code (A - ZZ) identifies
20-60 FLA & 120 FLA specific features per customer
3186 = 3 Pole - 75 & 90 FLA specifications. Consult factory
3300 = GFCI Rated Contactors for your specific needs.

Contactor Nomenclature
(2 & 3 pole up to 40 FLA)
CUSTOMER ID SUFFIX
Y = Individual Pack Assigned by the factory. (000-999)
- = Bulk Pack
A - ZZZ = Customer Identification
(Assigned by the factory) CONTACT RATINGS (INDUCTIVE)
1 Pole 2 Pole 3 Pole 4 Pole
POLE CONFIGURATION
3 = 20 FLA 7 = 20 FLA 8 = 25 FLA
10 = 1PNO
1 = 25 FLA 8 = 25 FLA 9 = 30 FLA
15 = 1PNO w/Shunt
2 = 30 FLA 5 = 25 FLA 9 = 30 FLA 10 = 40 FLA
20 = 2PNO
30 = 3PNO 14 = 35 FLA 6 = 30 FLA 10 = 40 FLA
40 = 4PNO 19 = 40 FLA 18 = 40 FLA 16 = 50 FLA
17 = 60 FLA
COIL VOLTAGE 50/60 Hz 75 = 75 FLA
Q = 24 VAC 90 = 90 FLA
T = 120 VAC 120 = 120 FLA
U = 208/240 VAC
EXAMPLE
V = 277 VAC
H = 480 VAC 3100-30Q10999CG:
L = 575 VAC The above example is a 3 pole 40
I = 24 VAC Molded
FLA with a 24 VAC coil, line & load
J = 120 VAC Molded
pole markings, dual quick connects
K = 208/240 VAC Molded
M = 277 VAC Molded
on the coil terminals, with a cover
N = 240 VAC 50Hz Molded over the contacts, dual quick con-
W = 480 VAC Molded nects on the
X = 575 VAC Molded power terminals with box lugs.
P = 100 VAC Bulk packed.
S = 200 VAC
* Molded coil is not available on 1 & 2 pole contactors

Terminations:

Std. on Optional on
20, 25, 30, 20, 25,
35 FLA 30, 35, .253
40 FLA .326
.406
.563

#10-32 Combination #10-32 Sems Screw 40 FLA Lug 50 & 60 FLA Lug 75 & 90 FLA Lug 120 FLA Lug
Phillips, Slotted & with pressure plate 14-4 Cu/Al 14-2Cu/Al 14-1/0 Cu/Al 2-4/0 Cu/Al
5/16 Hex Head AWG AWG AWG AWG
#12 washer
5
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
20 - 40 FLA 1 & 2 Pole Definite Purpose Contactors
3100 Series - Model 96
20 - 40 FLA 1 & 2 Pole

STANDARD “999” MODELS AVAILABLE


FLA RATING
1 Pole - 30 FLA 2 Pole - 30 FLA 2 Pole - 40 FLA
VOLTAGE

24VAC 3100-15Q2999 3100-20Q6999 3100-20Q18999CL


COIL

110/120 VAC 3100-15T2999 3100-20T6999 3100-20T18999CL


208/240 VAC 3100-15U2999 3100-20U6999 3100-20U18999CL
See page 3 for more details on standard models.
PARTIAL LISTING OF CUSTOM 1 POLE MODELS
FLA RATING
25 FLA 30 FLA 40 FLA
24VAC 3100-15Q1* 3100-15Q2* 3100-15Q19*
VOLTAGE
COIL

110/120 VAC 3100-15T1* 3100-15T2* 3100-15T19*


208/240 VAC 3100-15U1* 3100-15U2* 3100-15U19*
277 VAC 3100-15V1* 3100-15V2* 3100-15V19*
*A three digit customer ID suffix will be assigned by the factory.
To specify 1 pole without shunt, change “15” in part number to “10”.

PARTIAL LISTING OF CUSTOM 2 POLE MODELS


FLA RATING
20 FLA 25 FLA 30 FLA 40 FLA
24VAC 3100-20Q3* 3100-20Q5* 3100-20Q6* 3100-20Q18*
VOLTAGE
COIL

110/120 VAC 3100-20T3* 3100-20T5* 3100-20T6* 3100-20T18*


208/240 VAC 3100-20U3* 3100-20U5* 3100-20U6* 3100-20U18*
277 VAC 3100-20V3* 3100-20V5* 3100-20V6* 3100-20V18*
*A three digit customer ID suffix will be assigned by the factory.

SPECIFICATIONS
LINE AND LOAD TERMINALS ARC COVER
#10-32 screw or Box Lug Optional on 20 - 30 FLA, standard on 40 FLA
WIRE SIZE AWG MIN-M MAX INSULATION SYSTEM
#10-32 screw 16-8 (stranding must be split for #8 wire) 130°C Class B
Box lug 14-4 Cu/Al TEMPERATURE RANGE
RECOMMENDED TIGHTENING TORQUE -40°C to + 65°C
#10-32 screw 25 in. lbs -40°F to 150°F
Box Lug 40 in. lbs WEIGHT
QUICK CONNECTS 1 Pole .5 lb
Coil Terminals Dual .250 QC (2) 2 Pole .6 lb
Power Terminals 1 Pole: Quad .250 QC BOX QUANTITY
2 Pole: Dual or Quad .250 QC 50

AGENCY APPROVALS
UL Recognized - U.L. 508 Guide No.NLDX2
File No. E75492
CSA Approved - C22.2 NO.14, Class: 321104
File No. LR49598
CE / Semko Certified - EN60947-4-1:1991
IEC - 947-4-1
6
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
ELECTRICAL RATINGS

Full Number Line Locked Resistive Maximum Horsepower


Load of Voltage Rotor Amps Voltage Single
Amps Poles Amps Rating Phase
240/277 120 30 120 2
20 2 480 100 30 240 3
600 80 30
240/277 150 30 120 1

20 - 40 FLA 1 & 2 Pole Def ontactors


25 1 480 50 30 240 2
600 40 30
240/277 150 35 120 2
25 2 480 125 35 240 3
600 100 35
240/277 150 40 120 1
30 1 480 75 40 240 2
600 50 40
240/277 150 40 120 2
30 2 480 125 40 240 3
600 100 40
240/277 240 50 120 2
40 1 480 200 50 240 3
600 160 50
240/277 240 50 120 2
40 2 480 200 50 240 3
600 160 50

COIL TECHNICAL DATA


1 POLE CONTACTORS 2 POLE CONTACTORS
Nominal Coil Voltage 24 120 208/240 277 24 120 208/240 277
Maximum Pickup Volts 18 88 177 221 18 88 177 221
Drop-Out Volts Range 6 - 15 20 - 70 40 - 140 50 - 165 6 - 15 20 - 70 40 - 140 50 - 165
Nominal Inrush VA @ 50 Hz 22.5 22.5 22.5 22.5 37 37 37 37
Nominal Inrush VA @ 60 Hz 20 20 20 20 35 35 35 35
Nominal Sealed VA @ 50 Hz 7 7 7 7 8 8 8 8
Nominal Sealed VA @ 60 Hz 5.25 5.25 5.25 5.25 7 7 7 7
Nominal DC Resistance - Ohms 16.5 420 1850 2650 11 250 1000 1600

DIMENSIONS
2.10
Max.

neil
1 Pole 2.313 1.625
LABEL

3.30

.215
1.625 Typ.4
2.445 2.00
2.541
2.10
Max.

1.625
LABEL

2.313
2 Pole 3.30 .875

.215
1.625 Typ.4
2.445 2.00
2.610
SHOWN IN INCHES
7
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
3100 Series - Model 98
20 - 40 FLA 3 Pole Definite Purpose Contactors
20 - 40 FLA 3 Pole

STANDARD “999” MODELS AVAILABLE


FLA RATING
30 FLA 40 FLA
VOLTAGE

24VAC 3100-30Q9999CY 3100-30Q10999CG


COIL

110/120 VAC 3100-30T9999CY 3100-30T10999CG


208/240 VAC 3100-30U9999CY 3100-30U10999CG
See page 3 for more details on standard models.

PARTIAL LISTING OF CUSTOM MODELS


FLA RATING
20 FLA 25 FLA 30 FLA 40 FLA
24VAC 3100-30Q7* 3100-30Q8* 3100-30Q9* 3100-30Q10*
VOLTAGE
COIL

110/120 VAC 3100-30T7* 3100-30T8* 3100-30T9* 3100-30T10*


208/240 VAC 3100-30U7* 3100-30U8* 3100-30U9* 3100-30U10*
277 VAC 3100-30V7* 3100-30V8* 3100-30V9* 3100-30V10*
*A three digit customer ID suffix will be assigned by the factory.

SPECIFICATIONS
LINE AND LOAD TERMINALS ARC COVER
#10-32 screw or Box Lug Optional on 20 -30 FLA, standard on 40 FLA

WIRE SIZE AWG MIN-M


MAX INSULATION SYSTEM
#10-32 screw 16-8 (stranding must be split for #8 wire) 130°C Class B
Box Lug 14-4 Cu/Al
TEMPERATURE RANGE
RECOMMENDED TIGHTENING TORQUE -40°C to + 65°C
#10-32 screw 25 in. lbs -40°F to 150°F
Box Lug 40 in. lbs
WEIGHT
QUICK CONNECTS 1 lb
Power Terminals Dual .250 QC
Coil Terminals Dual .250 QC (2) BOX QUANTITY
(1)#6-32 screw & (1) .250 QCare optional 25

AUXILIARY SWITCHES AGENCY APPROVALS


The following is a partial listing of available auxiliary switches UL Recognized - U.L. 508 Guide No.NLDX2
for the contactors listed on this page. See page 19 for File No. E75492
additional parts and details. CSA Approved - C22.2 NO.14, Class: 321104
File No. LR49598
Part Number Description
CE / Semko Certified - EN60947-4-1:1991
98220-332 1 NO / 1 NC w/QCs
IEC - 947-4-1
98220-337 SPDT w/QCs
98220-344 1 NO / 1 NC w/screw terminals & saddle clamps

8
CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
ELECTRICAL RATINGS

20 - 40 FLA 3 Pole Definite Purpose Contactors


Full Number Line Locked Resistive Maximum Horsepower
Load of Voltage Rotor Amps Voltage Single Three
Amps Poles Amps Rating Phase Phase
240/277 120 30 110/120 1.5 -
20 3 480 100 30 200/240 3 7.5
600 80 30 480/600 - 7.5
110/120 2 -
240/277 150 35 200/208 - 7.5
25 3 480 125 35 240/277 5 10
600 100 35 480 - 15
600 - 20
110/120 2 -
240/277 180 40 200/208 - 10
30 3 480 150 40 240/277 5 10
600 120 40 480 - 15
600 - 20
110/120 3 -
240/277 240 50 200/208 - 10
40 3 480 200 50 240/277 7.5 10
600 160 50 480 - 20
600 - 25

COIL TECHNICAL DATA

Nominal Coil Voltage 24 120 208/240 277 480


Maximum Pickup Volts 18 88 177 220 384
Drop-Out Volts Range 6 -15 20 - 70 40 - 140 65 - 185 150 - 270
Nominal Inrush VA @ 50 Hz 60 60 60 60 65
Nominal Inrush VA @ 60 Hz 53 53 53 53 53
Nominal Sealed VA @ 50 Hz 6.0 6.0 6.0 6.0 6.0
Nominal Sealed VA @ 60 Hz 5 5 5 5 5
Nominal DC Resistance - Ohms 7 180 720 950 3100

DIMENSIONS

SHOWN IN INCHES

CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
9
3100 Series - Model 93
25-40 FLA 4 Pole Definite Purpose Contactors
25 - 40 FLA 4 Pole

PARTIAL LISTING OF CUSTOM MODELS


FLA RATING
25 FLA 30 FLA 40 FLA
24VAC 3100-40Q8* 3100-40Q9* 3100-40Q10*
VOLTAGE
COIL

110/120 VAC 3100-40T8* 3100-40T9* 3100-40T10*


208/240 VAC 3100-40U8* 3100-40U9* 3100-40U10*
277 VAC 3100-40V8* 3100-40V9* 3100-40V10*
*A three digit customer ID suffix will be assigned by the factory.

SPECIFICATIONS
LINE AND LOAD TERMINALS ARC COVER
#10-32 screw or Box Lug Optional on 20 -30 FLA, standard on 40 FLA

WIRE SIZE AWG MIN-M


MAX INSULATION SYSTEM
#10-32 screw 16-8 (stranding must be split for #8 wire) 130°C Class B
Box Lug 14-4 Cu/Al
TEMPERATURE RANGE
RECOMMENDED TIGHTENING TORQUE -40°C to + 65°C
#10-32 screw 25 in. lbs -40°F to 150°F
Box Lug 40 in. lbs
WEIGHT
QUICK CONNECTS 1.5 lbs
Power Terminals Dual .250 QC
Coil Terminals Dual .250 QC (2) BOX QUANTITY
(1)#6-32 screw & (1) .250 QCare optional 20

AUXILIARY SWITCHES AGENCY APPROVALS


The following is a partial listing of available auxiliary switches UL Recognized - U.L. 508 Guide No.NLDX2
for the contactors listed on this page. See page 18 for File No. E75492
additional parts and details. CSA Approved - C22.2 NO.14, Class: 321104
File No. LR49598
Part Number Description
CE / Semko Certified - EN60947-4-1:1991
34220-332N 1 NO / 1 NC w/QCs
IEC - 947-4-1
34220-337N SPDT w/QCs
34220-344N 1 NO / 1 NC w/screw terminals & saddle clamps

10 CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
ELECTRICAL RATINGS

25 - 40 FLA 4 Pole Definite Purpose Contactors


Full Number Line Locked Resistive Maximum Horsepower
Load of Voltage Rotor Amps Voltage Single Three
Amps Poles Amps Rating Phase Phase
240/277 150 35 110/120 2 -
25 4 480 125 35 200/208 - 7.5
600 100 35 240/277 5 10
480 - 15
240/277 180 40 110/120 2 -
30 4 480 150 40 200/208 - 10
600 120 40 240/277 5 10
480 - 15
240 240 50 110/120 3 -
40 4 480 200 50 200/208 - 10
600 160 50 240/277 7.5 10
480 - 20

COIL TECHNICAL DATA

Nominal Coil Voltage 24 120 208/240 277 480


Maximum Pickup Volts 19.2 93 177 220 384
Drop-Out Volts Range 6 -15 20 - 70 40 - 140 50 - 185 150 - 270
Nominal Inrush VA @ 50 Hz 68 68 68 58 48
Nominal Inrush VA @ 60 Hz 60 60 60 52 52
Nominal Sealed VA @ 50 Hz 14 14 14 11 11
Nominal Sealed VA @ 60 Hz 9 9 9.5 9.5 9
Nominal DC Resistance - Ohms 5 148 520 750 2700

DIMENSIONS
2.00
3.055 .250 .250
.203
NO
NC

3.25
3.75 3.125

2.493

2.633 .203 .203

SHOWN IN INCHES

CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
11
3100 Series - Model 93
50 & 60 FLA 3 Pole Definite Purpose Contactors
50 & 60 FLA 3 Pole

STANDARD “999” MODELS AVAILABLE


FLA RATING
50 FLA 60 FLA
VOLTAGE

24VAC 3100-30I16999CJ 3100-30I17999CJ


COIL

110/120 VAC 3100-30J16999CJ 3100-30J17999CJ


208/240 VAC 3100-30K16999CJ 3100-30K17999CJ
See page 3 for more details on standard models.

PARTIAL LISTING OF CUSTOM MODELS


FLA RATING
50 FLA 60 FLA
VOLTAGE

24VAC 3100-30Q16* 3100-30Q17*


COIL

110/120 VAC 3100-30T16* 3100-30T17*


208/240 VAC 3100-30U16* 3100-30U17*
277 VAC 3100-30V16* 3100-30V17*
*A three digit customer ID suffix will be assigned by the factory.

SPECIFICATIONS
LINE AND LOAD TERMINALS ARC COVER
1/4-20 screw or Box Lug Standard

WIRE SIZE AWG MIN-M


MAX INSULATION SYSTEM
14-2 Cu/Al 130°C Class B

RECOMMENDED TIGHTENING TORQUE TEMPERATURE RANGE


50 in. lbs -40°C to + 65°C
-40°F to 150°F
QUICK CONNECTS
Power Terminals Dual .250 QC WEIGHT
Coil Terminals #6-32 screw & .250 QC (2) 2 lbs
Dual .250 QC(2) are optional
BOX QUANTITY
10

AUXILIARY SWITCHES AGENCY APPROVALS


The following is a partial listing of available auxiliary switches UL Recognized - U.L. 508 Guide No.NLDX2
for the contactors listed on this page. See page 18 for File No. E75492
additional parts and details. CSA Approved - C22.2 NO.14, Class: 321104
File No. LR49598
Part Number Description CE / Semko Certified - EN60947-4-1:1991
34300-332 1 NO / 1 NC w/QCs IEC - 947-4-1
34300-337 SPDT w/QCs
34300-344 1 NO / 1 NC w/screw terminals & saddle clamps

12 CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
ELECTRICAL RATINGS

50 & 60 FLA 3 Pole Definite Purpose Contactors


Full Number Line Locked Resistive Maximum Horsepower
Load of Voltage Rotor Amps Voltage Single Three
Amps Poles Amps Rating Phase Phase
110/120 3 -
240 300 65 200/208 7.5 15
50 3 480 250 65 220-240 10 15
600 200 65 480 - 25
600 - 25
110/120 5 -
240 360 75 200/208 7.5 25
60 3 480 300 75 220-240 10 25
600 240 75 480 - 30
600 - 30

COIL TECHNICAL DATA

Nominal Coil Voltage 24 120 208/240 277 480


Maximum Pickup Volts 18 93 177 235 374
Drop-Out Volts Range 6 -15 20 - 70 40 - 135 50 - 180 120 - 286
Nominal Inrush VA @ 50 Hz 140 140 140 140 140
Nominal Inrush VA @ 60 Hz 132 132 132 132 132
Nominal Sealed VA @ 50 Hz 20 20 20 20 20
Nominal Sealed VA @ 60 Hz 14 14 14 14 14
Nominal DC Resistance - Ohms 2.4 45 180 280 852

DIMENSIONS
.218
3.563 3.10 Typ.6
2.032 .438
.25
2.75

3.25

3.75 3.19
NO
NC

1.468 .25
2.242
2.650
SHOWN IN INCHES

CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
13
3186 Series - Model 96
75 & 90 FLA 3 Pole Definite Purpose Contactors
75 & 90 FLA 3 Pole

STANDARD “999” MODELS AVAILABLE


FLA RATING
75 FLA 90 FLA
VOLTAGE

24VAC 3186Y30I75999CJ 3186Y30I90999CJ


COIL

110/120 VAC 3186Y30J75999CJ 3186Y30J90999CJ


208/240 VAC 3186Y30K75999CJ 3186Y30K90999CJ
See page 3 for more details on standard models.

PARTIAL LISTING OF CUSTOM MODELS


FLA RATING
75 FLA 90 FLA
24VAC 3186-30I75* 3186-30I90*
VOLTAGE
COIL

110/120 VAC 3186-30J75* 3186-30J90*


208/240 VAC 3186-30K75* 3186-30K90*
277 VAC 3186-30M75* 3186-30M90*
*A three digit customer ID suffix will be assigned by the factory.

SPECIFICATIONS
LINE AND LOAD TERMINALS ARC COVER
Box Lug Standard

WIRE SIZE AWG MIN-M


MAX INSULATION SYSTEM
14 - 1/0 Cu/Al 130°C Class B

RECOMMENDED TIGHTENING TORQUE TEMPERATURE RANGE


50 in. lbs -40°C to + 65°C
-40°F to 150°F
QUICK CONNECTS
Power Terminals Dual .250 QC WEIGHT
Coil Terminals #6-32 screw & .250 QC (2) 4 lbs

BOX QUANTITY
1
AUXILIARY SWITCHES AGENCY APPROVALS
The following is a partial listing of available auxiliary switches UL Recognized - U.L. 508 Guide No.NLDX2
for the contactors listed on this page. See page 18 for File No. E75492
additional parts and details. CSA Approved - C22.2 NO.14, Class: 122201
File No. LR47771
Part Number Description
34300-332 1 NO / 1 NC w/QCs
34300-337 SPDT w/QCs
34300-344 1 NO / 1 NC w/screw terminals & saddle clamps
14 CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
ELECTRICAL RATINGS

75 & 90 FLA 3 Pole Definite Purpose Contactors


Full Number Line Locked Resistive Maximum Horsepower
Load of Voltage Rotor Amps Voltage Single Three
Amps Poles Amps Rating Phase Phase
110/120 5 -
240 450 93 200/208 10 20
75 3 480 375 93 240 15 25
600 300 93 480 - 40
600 - 40
110/120 7.5 -
240 540 120 200/208 15 25
90 3 480 450 120 240 20 30
600 360 120 480 - 50
600 - 50

COIL TECHNICAL DATA

Nominal Coil Voltage 24 120 208/240 277 480


Maximum Pickup Volts 18 88 177 220 384
Drop-Out Volts Range 6 -15 20 - 70 40 - 110 65 - 185 150 - 270
Nominal Inrush VA @ 50 Hz 285 285 285 285 285
Nominal Inrush VA @ 60 Hz 240 240 240 240 240
Nominal Sealed VA @ 50 Hz 42 42 42 42 42
Nominal Sealed VA @ 60 Hz 27 27 27 27 27
Nominal DC Resistance - Ohms .63 15.6 63.5 84 255

DIMENSIONS
2.875
4.062 4.187
2.50
3.75

3.75
5.00
NO
NC

4.625

.203
.188 2.250
2.50
2.875
SHOWN IN INCHES

CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
15
3100 Series - Model A
120 FLA 3 Pole
120 FLA 3 Pole Definite Purpose Contactors

STANDARD “999” MODELS AVAILABLE


FLA RATING
120 FLA
VOLTAGE

24VAC 3100Y30Q12999CJ
COIL

110/120 VAC 3100Y30T12999CJ


208/240 VAC 3100Y30U12999CJ
See page 3 for more details on standard models.

PARTIAL LISTING OF CUSTOM MODELS


FLA RATING
120 FLA
24VAC 3100Y30Q12*
VOLTAGE

110/120 VAC 3100Y30T12*


COIL

208/240 VAC 3100Y30U12*


277 VAC 3100Y30V12*
*A three digit customer ID suffix will be assigned by the factory.

SPECIFICATIONS
LINE AND LOAD TERMINALS ARC COVER
Box Lug Standard

WIRE SIZE AWG MIN-M


MAX INSULATION SYSTEM
2 - 4/0 Cu/Al 130°C Class B

RECOMMENDED TIGHTENING TORQUE TEMPERATURE RANGE


100 in. lbs -40°C to + 65°C
-40°F to 150°F
QUICK CONNECTS
Coil Terminals #6-32 screw & .250 QC WEIGHT
8 lbs

BOX QUANTITY
1

AUXILIARY SWITCHES AGENCY APPROVALS


The following is a partial listing of available auxiliary switches UL Recognized - U.L. 508 Guide No.NLDX2
for the contactors listed on this page. See page 18 for File No. E75492
additional parts and details. CSA Approved - C22.2 NO.14, Class 122201
File No. LR47771
Part Number Description
34300-332 1 NO / 1 NC w/QCs
34300-337 SPDT w/QCs
34300-344 1 NO / 1 NC w/screw terminals & saddle clamps

16 CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
ELECTRICAL RATINGS

Full Number Line Locked Resistive Maximum Horsepower

120 FLA 3 Pole Definite Purpose Contactors


Load of Voltage Rotor Amps Voltage Single Three
Amps Poles Amps Rating Phase Phase
110/120 10 -
240 720 150 200/208 20 30
120 3 480 600 150 240 25 40
600 480 150 480 - 75
600 - 75

COIL TECHNICAL DATA

Nominal Coil Voltage 24 120 208/240 277 480


Maximum Pickup Volts 20.4 93 176 235 374
Drop-Out Volts Range 6 - 15.6 20 - 70 40 - 135 65 - 180 150 - 270
Nominal Inrush VA @ 50 Hz 470 600 600 600 -
Nominal Inrush VA @ 60 Hz 400 510 510 510 510
Nominal Sealed VA @ 50 Hz 43 50 50 50 -
Nominal Sealed VA @ 60 Hz 40 48 48 40 48
Nominal DC Resistance - Ohms .264 4.73 18.6 30.25 78

DIMENSIONS
4.625 2.50
5.00
Clearance
for #10
screw

6.375
4.437 6.00
NO
NC

4.625

.265
5.10 2.50 .187
2.875 .203
3.25 Dia.

SHOWN IN INCHES

CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
17
Auxiliary Switches
Models 93, 96 & A
The listings below show all of the various interlock / auxiliary switches available for the different
series of contactors. When selecting a switch, be sure it is intended for the contactor being used.

FOR MODEL 93: 20 - 40 FLA (1) (2)


Factory Modifications Field Added Kits
Description Contact Config. Kit Catalog Number of
NO NC Number Kits Required
Single unit interlock 1 0 34220-303N 1 NORMALLY OPEN
-303 STYLE
configurations listed. 0 1 34220-331N 1
Maximum of two. Must 1 1 34220-332N 1
be same polarity. 2 0 34220-303N 2
1/4” push-on terminals. 0 2 34220-331N 2
See footnote (1) for ratings. 2 2 34220-332N 2
SPDT Circuit 1 1 34220-337N 1
Auxiliary Switches

See footnote (2) for ratings. 2 2 34220-337N 2


NORMALLY CLOSED
SPDT Dry Circuit .1 amp max. 1 1 34220-341N 1 -331 STYLE
Gold Flashed Contacts 2 2 34220-341N 2
Same configurations 1 0 34220-342N 1
as above. #6-32 screw & 0 1 34220-343N 1
saddle clamp terminals. 1 1 34220-344N 1

FOR MODELS 96 & A : 30 - 120 FLA & MODEL 93: 50 & 60 FLA NORMALLY OPEN & CLOSED
Factory Modifications Field Added Kits -332 STYLE

Description Contact Config. Kit Catalog Number of


NO NC Number Kits Required
Single unit interlock 1 0 34300-303 1
configurations listed. 0 1 34300-331 1
Maximum of two. Must 1 1 34300-332 1
be same polarity. 2 0 34300-303 2
1/4” push-on terminals. 0 2 34300-331 2 SPDT
-337 & -341 STYLE
See footnote (1) for ratings. 2 2 34300-332 2
SPDT Circuit 1 1 34300-337 1
See footnote (2) for ratings. 2 2 34300-337 2
SPDT Dry Circuit .1 amp max. 1 1 34300-341 1
Gold Flashed Contacts 2 2 34300-341 2
Same configurations 1 0 34300-342 1
as above. #6-32 screw & 0 1 34300-343 1 W/ #6-32 SCREW & SADDLE CLAMP TERM.
saddle clamp terminals. 1 1 34300-344 1 -344 STYLE

FOOTNOTES: RATINGS OF AUXILIARY INTERLOCKS


(1) Contact Rating Single Circuit NO or NC and two circuit NO/NC: (2) Contact Rating SPDT (337):
Voltage Rating 10A, 1/3 HP, 125 or 250 VAC
120 240 480 600 1/2A, 125 VDC; 1/4A, 250 VDC:
Amperes - Break 3.0 1.5 0.75 0.6
4A 120 VAC on Lamp Load
Amperes - Make 30 15 7.5 6
Amperes - Continuous 10 10 10 10

18 CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com
Auxiliary Switches
Model 98
The listings below show all of the various interlock / auxiliary switches available for the Model 98
contactor. When selecting a switch, be sure it is intended for the contactor being used.
All auxiliary switches for the Model 98 are snap-oon design, no tools required.

FOR MODEL 98: 20 - 40 FLA


.250 QUICK CONNECT MODELS
Factory Modifications Field Added Kits
Description Contact Config. Kit Catalog Number of
NO NC Number Kits Required
ONE SPDT SWITCH PER SIDE Single unit interlock 1 0 98220-303 1
configurations listed. 0 1 98220-331 1
Maximum of two. 1 1 98220-332 1

Auxiliary Switches
(One on each side.) 2 0 98220-303 2
0 2 98220-331 2
See footnote (1) for ratings. 2 2 98220-332 2
SPDT Circuit 1 1 98220-337 1
(Either one or two 2 2 98220-338 1
switches per side.) 2 2 98220-337 2
See footnote (2) for ratings. 4 4 98220-338 2
SPDT Dry Circuit 1 1 98220-341 1
0.1 amp max. 2 2 98220-340 1
Gold Flashed Contacts 4 4 98220-340 2
TWO SPDT SWITCHES PER SIDE

FOR MODEL 98: 20 - 40 FLA


#6-3
32 SCREW TERMINALS & SADDLE CLAMPS
Factory Modifications Field Added Kits
Description Contact Config. Kit Catalog Number of
NO NC Number Kits Required
Single unit interlock 1 0 98220-342 1
configurations listed. 0 1 98220-343 1
Maximum of two. 1 1 98220-344 1
(One on each side.) 2 0 98220-342 2
0 2 98220-343 2
See footnote (1) for ratings. 2 2 98220-344 2
1 NO / 1 NC

FOOTNOTES: RATINGS OF AUXILIARY INTERLOCKS


(1) Contact Rating Single Circuit NO or NC and two circuit NO/NC: (2) Contact Rating SPDT (337):
Voltage Rating 10A, 1/3 HP, 125 or 250 VAC
120 240 480 600 1/2A, 125 VDC; 1/4A, 250 VDC:
Amperes - Break 3.0 1.5 0.75 0.6
4A 120 VACon Lamp Load
Amperes - Make 30 15 7.5 6
Amperes - Continuous 10 10 10 10

CII Technologies / P.O. Box 956 / Sterling, IL 61081 / ph 815.626.0300 / fax 815.626.8637 / website www.ciitech.com